@@ -25,8 +25,8 @@ CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB1000.DBB0
ADDR_WRITE=DB1001.DBB0
ADDR_READ=DB700.DBB0
ADDR_WRITE=DB01.DBB0
SIZE_READ=64
SIZE_WRITE=90
+33 -91
View File
@@ -169,68 +169,6 @@ namespace IOB_WIN
}
/// <summary>
/// Recupero dati dinamici in formato dictionary
/// </summary>
/// <returns></returns>
public override Dictionary<string, string> getDynData()
{
Dictionary<string, string> outVal = new Dictionary<string, string>();
#if false
try
{
/* ----------------------------------------------------------
* DB60.DBD6: pressione camera filtrante (salvataggio del MAX ogni minuto) | var testVal = S7.Net.Types.Double.FromByteArray(memByteRead.Skip(0).Take(4).ToArray());
* DB60.DBD10: pressione linea utenze (salvataggio del MAX ogni minuto)
* DB60.DBD14: temperatura acqua pulita (salvataggio del MAX ogni minuto)
* */
double pressCamFilt = S7.Net.Types.Double.FromByteArray(RawInput.Skip(6).Take(4).ToArray());
double pressLinUt = S7.Net.Types.Double.FromByteArray(RawInput.Skip(10).Take(4).ToArray());
double tempH2O = S7.Net.Types.Double.FromByteArray(RawInput.Skip(14).Take(4).ToArray());
if (utils.CRB("enableTSVC"))
{
// salvo in stack le VC rilevate
bool scad01 = stackVal_TSVC("pressCamFilt", pressCamFilt);
bool scad02 = stackVal_TSVC("pressLinUt", pressLinUt);
bool scad03 = stackVal_TSVC("tempH2O", tempH2O);
// verifico SE devo riportare dati VC
if (scad01 || scad02 || scad03)
{
pressCamFilt = getVal_TSVC("pressCamFilt", scad01);
pressLinUt = getVal_TSVC("pressLinUt", scad02);
tempH2O = getVal_TSVC("tempH2O", scad03);
outVal.Add("DYNDATA", $"pressCamFilt {pressCamFilt:N6} | pressLinUt {pressLinUt:N6} | tempH2O {tempH2O:N3}");
outVal.Add("pressCamFilt", $"{pressCamFilt:N6}");
outVal.Add("pressLinUt", $"{pressLinUt:N6}");
outVal.Add("tempH2O", $"{tempH2O:N3}");
// salvo!
LastTSVC["pressCamFilt"] = pressCamFilt;
LastTSVC["pressLinUt"] = pressLinUt;
LastTSVC["tempH2O"] = tempH2O;
}
else
{
outVal.Add("DYNDATA", $"pressCamFilt {LastTSVC["pressCamFilt"]:N6} | pressLinUt {LastTSVC["pressLinUt"]:N6} | tempH2O {LastTSVC["tempH2O"]:N3}");
}
}
else
{
outVal.Add("pressCamFilt", $"{pressCamFilt:N6}");
outVal.Add("pressLinUt", $"{pressLinUt:N6}");
outVal.Add("tempH2O", $"{tempH2O:N3}");
outVal.Add("DYNDATA", $"pressCamFilt {pressCamFilt:N3} | pressLinUt {pressLinUt:N3} | tempH2O {tempH2O:N3}");
}
}
catch (Exception exc)
{
lgError(exc, "Errore in getDynData x Siemens Aprochim");
}
#endif
return outVal;
}
/// <summary>
/// Effettua decodifica aree memoria alla bitmap usata x MAPO
/// </summary>
@@ -248,46 +186,50 @@ namespace IOB_WIN
* B4: manuale
* B5: emergenza
*
*
* - BIT di stato
* - DB60.DBX3.0: AUSILIARI INSERITI = NO EMERGENZA
* - DB60.DBX3.1: Filtro (macchina) in LAVORAZIONE
* - DB60.DBX3.2: Selettore in AUTOMATICO (sennò GIALLO)
* - DB60.DBX3.3: WARNING MIN LIV VASCA (arancio)
* - DB60.DBX3.4: WARNING MIN LIV CELLULOSA (blu)
* - DB60.DBX3.5: LAMPADA ROSSA (allarmi almeno 1 attivo)
*
* - BIT di stato
* - DBX0.0: Macchina in LAVORAZIONE
* - DBX0.1: Macchina in CICLO
* - DBX0.2: Macchina in MANUALE
* - DBX0.3: Macchina in ALLARME
* - DBX0.4: Macchina in EMERGENZA
----------------------------------------------------- */
/* -----------------------------------------------------
* bitmap MAPO FILTRO Aprochim
* B0: POWER_ON
* B1: RUN
* B2: AUTOMATICO
* B3: WARN_MIN_VASCA
* B4: WARN_MIN_CELL
* B5: ALARM
* B6: EMERGENZA
----------------------------------------------------- */
// bit 0 (poweron) imposto a 1 SE connected...
B_input = currPLC.IsConnected ? 1 : 0;
// recupero byte segnali...
int byteSignals = RawInput[3];
// aggiungo "in coda" primo bit emergenza...essendo un bit negato (NON emergenza) lo cambio di segno
if ((byteSignals & (1 << 0)) == 0)
{
byteSignals += (1 << 6);
}
// cancello primo bit (faccio uno shift a dx e poi a sx di 1...)
byteSignals = ((byteSignals >> 1) << 1);
// recupero byte segnali...
byte mainData = RawInput[0];
int byteSignals = 0;
// bit 0 (poweron) imposto a 1 SE connected...
if (currPLC.IsConnected)
{
byteSignals += (1 << 0);
}
// RUN se lavora ed in ciclo
if ((mainData & (1 << 0)) == 1 && (mainData & (1 << 1)) == 1)
{
byteSignals += (1 << 1);
}
// manuale
if ((mainData & (1 << 2)) == 1)
{
byteSignals += (1 << 4);
}
// allarme
if ((mainData & (1 << 3)) == 1)
{
byteSignals += (1 << 3);
}
// emergenza
if ((mainData & (1 << 4)) == 1)
{
byteSignals += (1 << 5);
}
// salvo!
B_input = byteSignals;
Vendored
+1 -1
View File
@@ -16,7 +16,7 @@ pipeline {
/* calcolo numero versione... diverso x branch MASTER/DEVELOP */
script {
withEnv(['NEXT_BUILD_NUMBER=526']) {
withEnv(['NEXT_BUILD_NUMBER=527']) {
// env.versionNumber = VersionNumber(versionNumberString : '2.4.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true)
env.versionNumber = VersionNumber(versionNumberString : '2.4.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true, overrideBuildsAllTime: '${NEXT_BUILD_NUMBER}')
env.APP_NAME = 'MAPO-IOB-WIN'