diff --git a/IOB-WIN/DATA/CONF/VL25.ini b/IOB-WIN/DATA/CONF/VL25.ini
index 9b5ff55c..247272f4 100644
--- a/IOB-WIN/DATA/CONF/VL25.ini
+++ b/IOB-WIN/DATA/CONF/VL25.ini
@@ -25,8 +25,8 @@ CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
-ADDR_READ=DB1000.DBB0
-ADDR_WRITE=DB1001.DBB0
+ADDR_READ=DB700.DBB0
+ADDR_WRITE=DB01.DBB0
SIZE_READ=64
SIZE_WRITE=90
diff --git a/IOB-WIN/IobSiemensIngenia.cs b/IOB-WIN/IobSiemensIngenia.cs
index 2be96bda..f01697a4 100644
--- a/IOB-WIN/IobSiemensIngenia.cs
+++ b/IOB-WIN/IobSiemensIngenia.cs
@@ -169,68 +169,6 @@ namespace IOB_WIN
}
- ///
- /// Recupero dati dinamici in formato dictionary
- ///
- ///
- public override Dictionary getDynData()
- {
- Dictionary outVal = new Dictionary();
-#if false
- try
- {
- /* ----------------------------------------------------------
- * DB60.DBD6: pressione camera filtrante (salvataggio del MAX ogni minuto) | var testVal = S7.Net.Types.Double.FromByteArray(memByteRead.Skip(0).Take(4).ToArray());
- * DB60.DBD10: pressione linea utenze (salvataggio del MAX ogni minuto)
- * DB60.DBD14: temperatura acqua pulita (salvataggio del MAX ogni minuto)
- * */
- double pressCamFilt = S7.Net.Types.Double.FromByteArray(RawInput.Skip(6).Take(4).ToArray());
- double pressLinUt = S7.Net.Types.Double.FromByteArray(RawInput.Skip(10).Take(4).ToArray());
- double tempH2O = S7.Net.Types.Double.FromByteArray(RawInput.Skip(14).Take(4).ToArray());
-
- if (utils.CRB("enableTSVC"))
- {
- // salvo in stack le VC rilevate
- bool scad01 = stackVal_TSVC("pressCamFilt", pressCamFilt);
- bool scad02 = stackVal_TSVC("pressLinUt", pressLinUt);
- bool scad03 = stackVal_TSVC("tempH2O", tempH2O);
-
- // verifico SE devo riportare dati VC
- if (scad01 || scad02 || scad03)
- {
- pressCamFilt = getVal_TSVC("pressCamFilt", scad01);
- pressLinUt = getVal_TSVC("pressLinUt", scad02);
- tempH2O = getVal_TSVC("tempH2O", scad03);
- outVal.Add("DYNDATA", $"pressCamFilt {pressCamFilt:N6} | pressLinUt {pressLinUt:N6} | tempH2O {tempH2O:N3}");
- outVal.Add("pressCamFilt", $"{pressCamFilt:N6}");
- outVal.Add("pressLinUt", $"{pressLinUt:N6}");
- outVal.Add("tempH2O", $"{tempH2O:N3}");
- // salvo!
- LastTSVC["pressCamFilt"] = pressCamFilt;
- LastTSVC["pressLinUt"] = pressLinUt;
- LastTSVC["tempH2O"] = tempH2O;
- }
- else
- {
- outVal.Add("DYNDATA", $"pressCamFilt {LastTSVC["pressCamFilt"]:N6} | pressLinUt {LastTSVC["pressLinUt"]:N6} | tempH2O {LastTSVC["tempH2O"]:N3}");
- }
- }
- else
- {
- outVal.Add("pressCamFilt", $"{pressCamFilt:N6}");
- outVal.Add("pressLinUt", $"{pressLinUt:N6}");
- outVal.Add("tempH2O", $"{tempH2O:N3}");
- outVal.Add("DYNDATA", $"pressCamFilt {pressCamFilt:N3} | pressLinUt {pressLinUt:N3} | tempH2O {tempH2O:N3}");
- }
- }
- catch (Exception exc)
- {
- lgError(exc, "Errore in getDynData x Siemens Aprochim");
- }
-#endif
- return outVal;
- }
-
///
/// Effettua decodifica aree memoria alla bitmap usata x MAPO
///
@@ -248,46 +186,50 @@ namespace IOB_WIN
* B4: manuale
* B5: emergenza
*
- *
- * - BIT di stato
- * - DB60.DBX3.0: AUSILIARI INSERITI = NO EMERGENZA
- * - DB60.DBX3.1: Filtro (macchina) in LAVORAZIONE
- * - DB60.DBX3.2: Selettore in AUTOMATICO (sennĂ² GIALLO)
- * - DB60.DBX3.3: WARNING MIN LIV VASCA (arancio)
- * - DB60.DBX3.4: WARNING MIN LIV CELLULOSA (blu)
- * - DB60.DBX3.5: LAMPADA ROSSA (allarmi almeno 1 attivo)
+ *
+ * - BIT di stato
+ * - DBX0.0: Macchina in LAVORAZIONE
+ * - DBX0.1: Macchina in CICLO
+ * - DBX0.2: Macchina in MANUALE
+ * - DBX0.3: Macchina in ALLARME
+ * - DBX0.4: Macchina in EMERGENZA
----------------------------------------------------- */
-
- /* -----------------------------------------------------
- * bitmap MAPO FILTRO Aprochim
- * B0: POWER_ON
- * B1: RUN
- * B2: AUTOMATICO
- * B3: WARN_MIN_VASCA
- * B4: WARN_MIN_CELL
- * B5: ALARM
- * B6: EMERGENZA
- ----------------------------------------------------- */
-
// bit 0 (poweron) imposto a 1 SE connected...
B_input = currPLC.IsConnected ? 1 : 0;
- // recupero byte segnali...
- int byteSignals = RawInput[3];
- // aggiungo "in coda" primo bit emergenza...essendo un bit negato (NON emergenza) lo cambio di segno
- if ((byteSignals & (1 << 0)) == 0)
- {
- byteSignals += (1 << 6);
- }
- // cancello primo bit (faccio uno shift a dx e poi a sx di 1...)
- byteSignals = ((byteSignals >> 1) << 1);
+ // recupero byte segnali...
+ byte mainData = RawInput[0];
+ int byteSignals = 0;
+
// bit 0 (poweron) imposto a 1 SE connected...
if (currPLC.IsConnected)
{
byteSignals += (1 << 0);
}
+
+ // RUN se lavora ed in ciclo
+ if ((mainData & (1 << 0)) == 1 && (mainData & (1 << 1)) == 1)
+ {
+ byteSignals += (1 << 1);
+ }
+ // manuale
+ if ((mainData & (1 << 2)) == 1)
+ {
+ byteSignals += (1 << 4);
+ }
+ // allarme
+ if ((mainData & (1 << 3)) == 1)
+ {
+ byteSignals += (1 << 3);
+ }
+ // emergenza
+ if ((mainData & (1 << 4)) == 1)
+ {
+ byteSignals += (1 << 5);
+ }
+
// salvo!
B_input = byteSignals;
diff --git a/Jenkinsfile b/Jenkinsfile
index b9e2a4d1..12fb13b2 100644
--- a/Jenkinsfile
+++ b/Jenkinsfile
@@ -16,7 +16,7 @@ pipeline {
/* calcolo numero versione... diverso x branch MASTER/DEVELOP */
script {
- withEnv(['NEXT_BUILD_NUMBER=526']) {
+ withEnv(['NEXT_BUILD_NUMBER=527']) {
// env.versionNumber = VersionNumber(versionNumberString : '2.4.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true)
env.versionNumber = VersionNumber(versionNumberString : '2.4.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true, overrideBuildsAllTime: '${NEXT_BUILD_NUMBER}')
env.APP_NAME = 'MAPO-IOB-WIN'