Compare commits

...

6 Commits

Author SHA1 Message Date
andrea.villa 49316c92fc Merge branch 'develop' 2025-01-07 14:37:19 +01:00
andrea.villa a479cfac69 Commit per versione 2025-01-07 14:36:41 +01:00
andrea.villa 692601f07e Aumentati limiti massimi di pinzaggio minimo 2024-12-18 12:03:30 +01:00
andrea.villa 487bbf1ce6 Per controllo NUM si blocca generazione se lavorazione con aggregato (mai gestito) 2024-12-12 14:56:58 +01:00
andrea.villa c7ebf339ec Nuovo aggregato 90° (H7) per fresa tipo BlockHaus. 2024-12-05 16:23:42 +01:00
andrea.villa 685e63dd83 Merge remote-tracking branch 'origin/main' into develop 2024-12-02 08:25:40 +01:00
7 changed files with 57 additions and 20 deletions
+5 -2
View File
@@ -1532,7 +1532,10 @@ function MyAdjustLinearAxes()
if EMT.REFLOC then
local vtE
if EMT.HEAD ~= 'H3' then
-- su NUM aggregati non gestiti
if EMT.HEAD == 'H5' or EMT.HEAD == 'H6' or EMT.HEAD == 'H7' then
EmtSetLastError( 1211, "Aggregates not managed")
elseif EMT.HEAD ~= 'H3' then
local Len = EMT.TLEN + EgtIf( EMT.HEAD == 'H1', MillOffs, abs( SawOffs))
local LenRef = MillOffs
vtE = Vector3d( EMT.EXTR) * Len - Z_AX() * LenRef
@@ -1647,7 +1650,7 @@ end
---------------------------------------------------------------------
function GetET( sHead, sTcPos, dAxR3)
if sHead == 'H1' or sHead == 'H5' or sHead == 'H6' then
if sHead == 'H1' or sHead == 'H5' or sHead == 'H6' or sHead == 'H7' then
return ' E'..sTcPos
elseif sHead == 'H2' then
return ' ET42'
+15 -6
View File
@@ -145,7 +145,11 @@ function OnToolData()
local sPos = 'N2' .. tostring(nPos)
local sOut = 'L11=' .. EmtLenToString( EMT.SMAX, 3) .. ' L12=' .. EmtLenToString( AngTr1Offs, 1)..' G76H9998.1'..sPos..sPos
EmtOutput( sOut)
-- altro non previsto
-- emissione dati sega a catena
elseif EMT.HEAD == 'H7' then
local sOut = 'L11='..EgtNumToString( EMT.SMAX, 0)..' L12='..EmtLenToString( ( 154.5), 1)..' G76H9998.1N121N121'
EmtOutput( sOut)
-- altro non previsto
end
end
@@ -693,7 +697,7 @@ function OnRapid()
if EMT.HEAD == 'H3' then
sEL = sEL..EmtLenToString( ( EMT.TDIST or ChSawLen), 3)
-- se aggregato
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' then
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' or EMT.HEAD == 'H7' then
sEL = sEL..EmtLenToString( AngTr1Offs, 3)
-- se testa normale ( H1 or H2)
else
@@ -705,7 +709,7 @@ function OnRapid()
if EMT.HEAD == 'H3' then
sER = sER..EmtLenToString( EMT.TLEN, 3)
-- se aggregato
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' then
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' or EMT.HEAD == 'H7' then
sER = sER..EmtLenToString( EMT.TLEN + AngTr1Len, 3)
-- se testa normale ( H1 or H2)
else
@@ -1017,7 +1021,7 @@ end
---------------------------------------------------------------------
function OnArc()
-- con aggregato non si possono fare archi. Deve essere tutto spezzato
if EMT.HEAD == 'H5' or EMT.HEAD == 'H6' then
if EMT.HEAD == 'H5' or EMT.HEAD == 'H6' or EMT.HEAD == 'H7' then
EmtSetLastError( 1211, "With aggregate, the arcs must be splitted")
end
@@ -1642,11 +1646,16 @@ function MyAdjustLinearAxes()
local LenRef = MillOffs
local vtAux = EgtGetCalcAuxDirFromAngles( EMT.R1, EMT.R2, EMT.R3)
vtE = vtAux * LenAux - Z_AX() * LenRef
elseif EMT.HEAD == 'H5' then
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' then
local LenAux = AngTr1Offs + MillOffs
local LenRef = MillOffs
local vtAux = EgtGetCalcAuxDirFromAngles( EMT.R1, EMT.R2, EMT.R3)
vtE = vtAux * LenAux - Z_AX() * LenRef
elseif EMT.HEAD == 'H7' then
local LenAux = AngTrBHOffs + MillOffs
local LenRef = MillOffs
local vtAux = EgtGetCalcAuxDirFromAngles( EMT.R1, EMT.R2, EMT.R3)
vtE = vtAux * LenAux - Z_AX() * LenRef
else
EmtSetLastError( 1211, 'Head not allowed ' .. EMT.HEAD)
end
@@ -1741,7 +1750,7 @@ end
---------------------------------------------------------------------
function GetET( sHead, sTcPos, dAxR3)
if sHead == 'H1' or sHead == 'H5' or sHead == 'H6' then
if sHead == 'H1' or sHead == 'H5' or sHead == 'H6' or sHead == 'H7' then
return ' E'..sTcPos
elseif sHead == 'H2' then
return ' ET42'
+15 -2
View File
@@ -151,7 +151,12 @@ function OnToolData()
local sOut = 'M992 P1=' .. EgtNumToString( nPos, 0) .. ' P2=' .. EmtLenToString( EMT.TLEN, 3) .. ' P3=' .. EmtLenToString( EMT.TDIAM, 3) ..
' P4=' .. EmtLenToString( EMT.SMAX, 3) .. ' P5=' .. EmtLenToString( EMT.TTOTLEN, 3)
ParkLine( sOut)
-- altro non previsto
-- emissione dati sega a catena
elseif EMT.HEAD == 'H7' then
local sOut = 'M992 P1=' .. EMT.TCPOS:gsub( 'T', '') .. ' P2=' .. EmtLenToString( EMT.TLEN, 3) .. ' P3=' .. EmtLenToString( EMT.TDIAM, 3) ..
' P4=' .. EmtLenToString( EMT.SMAX, 3) .. ' P5=' .. EmtLenToString( EMT.TTOTLEN, 3)
ParkLine( sOut)
-- altro non previsto
else
EmtSetLastError( 1211, 'Head not allowed ' .. EMT.HEAD)
end
@@ -1640,12 +1645,18 @@ function MyAdjustLinearAxes()
local LenRef = MillOffs
local vtAux = EgtGetCalcAuxDirFromAngles( EMT.R1, EMT.R2, EMT.R3)
vtE = vtAux * LenAux - Z_AX() * LenRef
elseif EMT.HEAD == 'H5' then
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' then
local Len = EMT.TLEN + AngTr1Len
local LenAux = MillOffs + AngTr1Offs
local LenRef = MillOffs
local vtAux = EgtGetCalcAuxDirFromAngles( EMT.R1, EMT.R2)
vtE = Vector3d( EMT.EXTR) * Len + vtAux * LenAux - Z_AX() * LenRef
elseif EMT.HEAD == 'H7' then
local Len = EMT.TLEN + AngTrBHLen
local LenAux = MillOffs + AngTrBHOffs
local LenRef = MillOffs
local vtAux = EgtGetCalcAuxDirFromAngles( EMT.R1, EMT.R2)
vtE = Vector3d( EMT.EXTR) * Len + vtAux * LenAux - Z_AX() * LenRef
else
EmtSetLastError( 1211, 'Head not allowed ' .. EMT.HEAD)
end
@@ -1682,6 +1693,8 @@ function AdjustToolKinematic()
return EgtIf( EMT.EXIT == 1, '11', '12')
elseif EMT.HEAD == 'H6' then
return EgtIf( EMT.EXIT == 1, '21', '22')
elseif EMT.HEAD == 'H7' then
return '31'
else
EmtSetLastError( 1211, 'Head not allowed ' .. EMT.HEAD)
end
+15 -7
View File
@@ -105,6 +105,7 @@ function OnSimulStart()
AddToCollisionCheck( 'B', 'COLLISION', EMT.COLLOBJ)
AddToCollisionCheck( 'C', 'COLLISION', EMT.COLLOBJ)
AddToCollisionCheck( 'H5', 'COLLISION', EMT.COLLOBJ)
AddToCollisionCheck( 'H6', 'COLLISION', EMT.COLLOBJ)
AddToolToCollisionCheck( 'H2', 1, EMT.COLLOBJ)
AddToolHolderToCollisionCheck( 'H2', 1, EMT.COLLOBJ)
DumpCollisionCheck( EMT.COLLOBJ, 'Collision Objects :', 4)
@@ -180,7 +181,7 @@ function OnSimulDispositionStart()
if sTool and nTlen < LONG_TOOL_MINLEN then
EMT.TOOL_1 = sTool
else
EMT.TOOL_1 = GetDefaultToolName()
EMT.TOOL_1 = GetDefaultToolName()
end
EgtLoadTool( 'H1', 1, EMT.TOOL_1)
EMT.TCPOS_1 = GetToolTcPos( EMT.TOOL_1)
@@ -190,7 +191,7 @@ function OnSimulDispositionStart()
EMT.VMILL = {}
if not EMT.SIM1ST and EgtGetInfo( EgtGetCurrMachGroup(), 'Vm', 'b') then
local nLastOrd = GetPhaseOrd( EgtGetPhaseCount())
local nPartRawId = EgtGetFirstRawPart()
local nPartRawId = EgtGetFirstRawPart()
while nPartRawId do
-- se è lo scarto finale tagliato a pezzi, esco
local nRawOrd = EgtGetInfo( nPartRawId, 'ORD', 'i')
@@ -511,6 +512,9 @@ function OnSimulToolSelect( dPosA)
EgtSetAxisPos( 'C', EgtIf( BD.RIGHT_LOAD, 180, 0))
end
EgtSetAxisPos( 'B', 0)
-- se aggregato per fresa tipo blockhaus
elseif EMT.HEAD == 'H7' then
EgtSetAxisPos( 'C', EgtIf( BD.RIGHT_LOAD, 180, 0))
end
-- se punta lunga
if EMT.TOTLEN > LONG_TOOL_MINLEN then
@@ -534,9 +538,9 @@ function OnSimulToolDeselect()
-- se prossimo utensile non definito, è disposizione ed esco
if EMT.NEXTTOOL == '' then return end
-- se cambia uscita su rinvio non devo fare alcunché
if EMT.HEAD == 'H5' and EMT.NEXTHEAD == 'H5' then return end
if ( EMT.HEAD == 'H5' and EMT.NEXTHEAD == 'H5') or ( EMT.HEAD == 'H6' and EMT.NEXTHEAD == 'H6') then return end
-- se sega a catena o rinvio o punta lunga o utensile di grosso diametro, devo cambiare
if EMT.HEAD == 'H3' or EMT.HEAD == 'H5' or ( EMT.HEAD == 'H1' and ( EMT.TOTLEN > LONG_TOOL_MINLEN or EMT.TOTDIAM > BIG_TOOL_DIAM)) then
if EMT.HEAD == 'H3' or EMT.HEAD == 'H5' or EMT.HEAD == 'H6' or EMT.HEAD == 'H7' or ( EMT.HEAD == 'H1' and ( EMT.TOTLEN > LONG_TOOL_MINLEN or EMT.TOTDIAM > BIG_TOOL_DIAM)) then
EgtOutText( 'Tool change in progress...')
-- movimento scarico sega a catena
if EMT.HEAD == 'H3' then
@@ -552,9 +556,13 @@ function OnSimulToolDeselect()
end
SimulMoveAxis( 'X', 0, MCH_SIM_STEP.RAPID)
-- movimento scarico rinvio
elseif EMT.HEAD == 'H5' then
elseif EMT.HEAD == 'H5' or EMT.HEAD == 'H6' then
SimulMoveAxes( 'B', 0, MCH_SIM_STEP.COLLROT, 'C', -90, MCH_SIM_STEP.COLLROT)
SimulMoveAxis( 'X', 0, MCH_SIM_STEP.RAPID)
-- movimento scarico aggregato BlockHaus
elseif EMT.HEAD == 'H7' then
SimulMoveAxis( 'X', 0, MCH_SIM_STEP.RAPID)
SimulMoveAxes( 'B', 90, MCH_SIM_STEP.COLLROT, 'C', -90, MCH_SIM_STEP.COLLROT)
-- movimento scarico punta lunga su T111
elseif EMT.TOTLEN > LONG_TOOL_MINLEN then
-- se su cambio utensile T111
@@ -579,7 +587,7 @@ function OnSimulToolDeselect()
EgtSetMode( EgtGetHeadId( EMT.HEAD), GDB_MD.HIDDEN)
ShowToolInTcPos( EMT.TCPOS_1, true)
-- movimento per carico utensile
if EMT.NEXTHEAD ~= 'H3' and EMT.NEXTHEAD ~= 'H5' then
if EMT.NEXTHEAD ~= 'H3' and EMT.NEXTHEAD ~= 'H5' and EMT.NEXTHEAD ~= 'H6' then
SimulMoveAxes( 'B', 90, MCH_SIM_STEP.RAPROT, 'C', EgtIf( BD.RIGHT_LOAD, 90, -90), MCH_SIM_STEP.RAPROT)
else
SimulMoveAxes( 'B', 0, MCH_SIM_STEP.RAPROT, 'C', EgtIf( BD.RIGHT_LOAD, 90, -90), MCH_SIM_STEP.RAPROT)
@@ -605,7 +613,7 @@ function OnSimulToolDeselect()
EgtPause( 100)
ShowToolInTcPos( EMT.TCPOS_1, true)
-- se segue sega a catena
if EMT.NEXTHEAD == 'H3' or EMT.NEXTHEAD == 'H5' then
if EMT.NEXTHEAD == 'H3' or EMT.NEXTHEAD == 'H5' or EMT.NEXTHEAD == 'H6' then
-- se non lama, nascondo l'utensile corrente
if EMT.HEAD ~= 'H2' then
EgtSetStatus( EgtGetHeadId( EMT.HEAD), GDB_ST.OFF)
+2 -2
View File
@@ -33,9 +33,9 @@ local DeltaTol = DELTA_TOL_S
local DELTA_SIC = 1
local AGG_LOAD = 50
local MIN_JOIN_VV = EgtClamp( MinJoinVV or 75, 60, 150)
local MIN_JOIN_SS = EgtClamp( MinJoinSS or 100, 80, 200)
local MIN_JOIN_SS = EgtClamp( MinJoinSS or 100, 80, 275)
local MIN_JOIN_LS = EgtClamp( MinJoinLS or 290, 250, 400)
local MIN_JOIN_SL = EgtClamp( MinJoinSL or 100, 80, 200)
local MIN_JOIN_SL = EgtClamp( MinJoinSL or 100, 80, 400)
local MIN_JOIN_LL = EgtClamp( MinJoinLL or 400, 300, 600)
local MinJoin = MIN_JOIN_SS
local MinOther = abs( MinY) + abs( MaxV) + MinJoin
+4
View File
@@ -1,5 +1,9 @@
==== Common_FAST Update Log ====
Versione 2.7a1 (07/01/2024)
- (MLDE-SIM-GEN) Nuovo aggregato 90° (H7) per fresa tipo BlockHaus. Ticket#2142
- (SIM-GEN) Aumentati limiti massimi di pinzaggio minimo
Versione 2.6l1 (02/12/2024)
- (SIM) Corretto movimento VMILL durante scarico pezzo piccolo a caduta
- (SIM-GEN) Per decidere posizione parcheggio barra dopo separazione, si considera lunghezza coda del pezzo in lavoro per evitare collisioni. Ticket#2168
+1 -1
View File
@@ -3,7 +3,7 @@
local InfoCommon_STD_PP = {
NAME = 'Common_FAST', -- nome script PP standard
VERSION = '2.6l1', -- versione script
VERSION = '2.7a1', -- versione script
MIN_MACH_VER_PP_COMMON = '2.5k1' -- versione minima kernel
}