Merge branch 'develop'
This commit is contained in:
@@ -1,13 +1,18 @@
|
||||
<?xml version="1.0" encoding="utf-8" ?>
|
||||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<configuration>
|
||||
<startup>
|
||||
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.6.2" />
|
||||
</startup>
|
||||
<appSettings>
|
||||
<add key="appName" value="MHT-Proxy"/>
|
||||
<add key="verbose" value="false"/>
|
||||
<!--conf file-->
|
||||
<add key="memConfPath" value="setupData.json"/>
|
||||
<add key="sampleTimerMs" value="1000"/>
|
||||
</appSettings>
|
||||
</configuration>
|
||||
<startup>
|
||||
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.0"/>
|
||||
</startup>
|
||||
<appSettings>
|
||||
<add key="appName" value="MHT-Proxy"/>
|
||||
<add key="verbose" value="false"/>
|
||||
<!--conf file-->
|
||||
<add key="memConfPath" value="setupData.json"/>
|
||||
<add key="sampleTimerMs" value="1000"/>
|
||||
</appSettings>
|
||||
<runtime>
|
||||
<assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">
|
||||
<probing privatePath="lib;libs"/>
|
||||
</assemblyBinding>
|
||||
</runtime>
|
||||
</configuration>
|
||||
|
||||
@@ -27,7 +27,6 @@ C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bi
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Debug\S7.Net.dll
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Debug\Newtonsoft.Json.xml
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Debug\NLog.xml
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Debug\S7.Net.pdb
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Debug\MHT-Siemens.csprojAssemblyReference.cache
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Debug\MHT_Siemens.Properties.Resources.resources
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Debug\MHT_Siemens.SiemensProxy.resources
|
||||
@@ -36,3 +35,4 @@ C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\ob
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Debug\MHT-Siemens.csproj.CopyComplete
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Debug\MHT-Siemens.exe
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Debug\MHT-Siemens.pdb
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Debug\S7.Net.xml
|
||||
|
||||
@@ -9,6 +9,7 @@ C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bi
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Release\S7.Net.dll
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Release\Newtonsoft.Json.xml
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Release\NLog.xml
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Release\S7.Net.xml
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Release\MHT-Siemens.csprojAssemblyReference.cache
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Release\MHT_Siemens.Properties.Resources.resources
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Release\MHT_Siemens.SiemensProxy.resources
|
||||
@@ -17,4 +18,3 @@ C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\ob
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Release\MHT-Siemens.csproj.CopyComplete
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Release\MHT-Siemens.exe
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\obj\Release\MHT-Siemens.pdb
|
||||
C:\Users\samuele.steamw\Documents\VisualStudioProject\MHT-Siemens\MTH-Siemens\bin\Release\S7.Net.xml
|
||||
|
||||
Binary file not shown.
Binary file not shown.
Binary file not shown.
|
After Width: | Height: | Size: 1.3 MiB |
@@ -0,0 +1,2 @@
|
||||
Data e ora;Esito;Operator;*;Descrizione breve;Valore;UdM;Valore assoluto;UdM Val. Ass.;Esito;Valore nominale;Valore LTS;Valore LTI;Evento 1;Evento 2;Evento 3;Evento 4;Evento 5;Evento 6;Evento 7;Evento 8;Evento 9;Evento 10
|
||||
07/05/2020 12:14:57;G;Admin;*;1;-0,4262;mm;-0,4262;mm;G;0,0000;1,0000;-1,0000;;;;;;;;;;
|
||||
|
@@ -0,0 +1,2 @@
|
||||
Data e ora;Esito;Operator;*;Descrizione breve;Valore;UdM;Valore assoluto;UdM Val. Ass.;Esito;Valore nominale;Valore LTS;Valore LTI;Evento 1;Evento 2;Evento 3;Evento 4;Evento 5;Evento 6;Evento 7;Evento 8;Evento 9;Evento 10
|
||||
07/05/2020 12:56:24;G;Admin;*;1;0,0590;mm;0,0590;mm;G;0,0000;1,0000;-1,0000;;;;;;;;;;
|
||||
|
Binary file not shown.
Binary file not shown.
Binary file not shown.
File diff suppressed because it is too large
Load Diff
Binary file not shown.
+46
-2012
File diff suppressed because it is too large
Load Diff
Binary file not shown.
Binary file not shown.
@@ -0,0 +1,991 @@
|
||||
<?xml version="1.0"?>
|
||||
<doc>
|
||||
<assembly>
|
||||
<name>S7.Net</name>
|
||||
</assembly>
|
||||
<members>
|
||||
<member name="T:S7.Net.Conversion">
|
||||
<summary>
|
||||
Conversion methods to convert from Siemens numeric format to C# and back
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.BinStringToInt32(System.String)">
|
||||
<summary>
|
||||
Converts a binary string to Int32 value
|
||||
</summary>
|
||||
<param name="txt"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.BinStringToByte(System.String)">
|
||||
<summary>
|
||||
Converts a binary string to a byte. Can return null.
|
||||
</summary>
|
||||
<param name="txt"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ValToBinString(System.Object)">
|
||||
<summary>
|
||||
Converts the value to a binary string
|
||||
</summary>
|
||||
<param name="value"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.SelectBit(System.Byte,System.Int32)">
|
||||
<summary>
|
||||
Helper to get a bit value given a byte and the bit index.
|
||||
Example: DB1.DBX0.5 -> var bytes = ReadBytes(DB1.DBW0); bool bit = bytes[0].SelectBit(5);
|
||||
</summary>
|
||||
<param name="data"></param>
|
||||
<param name="bitPosition"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ConvertToShort(System.UInt16)">
|
||||
<summary>
|
||||
Converts from ushort value to short value; it's used to retrieve negative values from words
|
||||
</summary>
|
||||
<param name="input"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ConvertToUshort(System.Int16)">
|
||||
<summary>
|
||||
Converts from short value to ushort value; it's used to pass negative values to DWs
|
||||
</summary>
|
||||
<param name="input"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ConvertToInt(System.UInt32)">
|
||||
<summary>
|
||||
Converts from UInt32 value to Int32 value; it's used to retrieve negative values from DBDs
|
||||
</summary>
|
||||
<param name="input"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ConvertToUInt(System.Int32)">
|
||||
<summary>
|
||||
Converts from Int32 value to UInt32 value; it's used to pass negative values to DBDs
|
||||
</summary>
|
||||
<param name="input"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ConvertToUInt(System.Double)">
|
||||
<summary>
|
||||
Converts from double to DWord (DBD)
|
||||
</summary>
|
||||
<param name="input"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Conversion.ConvertToDouble(System.UInt32)">
|
||||
<summary>
|
||||
Converts from DWord (DBD) to double
|
||||
</summary>
|
||||
<param name="input"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.COTP">
|
||||
<summary>
|
||||
COTP Protocol functions and types
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.COTP.TPDU">
|
||||
<summary>
|
||||
Describes a COTP TPDU (Transport protocol data unit)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.COTP.TPDU.Read(System.Net.Sockets.Socket)">
|
||||
<summary>
|
||||
Reads COTP TPDU (Transport protocol data unit) from the network stream
|
||||
See: https://tools.ietf.org/html/rfc905
|
||||
</summary>
|
||||
<param name="socket">The socket to read from</param>
|
||||
<returns>COTP DPDU instance</returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.COTP.TSDU">
|
||||
<summary>
|
||||
Describes a COTP TSDU (Transport service data unit). One TSDU consist of 1 ore more TPDUs
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.COTP.TSDU.Read(System.Net.Sockets.Socket)">
|
||||
<summary>
|
||||
Reads the full COTP TSDU (Transport service data unit)
|
||||
See: https://tools.ietf.org/html/rfc905
|
||||
</summary>
|
||||
<returns>Data in TSDU</returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.CpuType">
|
||||
<summary>
|
||||
Types of S7 cpu supported by the library
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.CpuType.S7200">
|
||||
<summary>
|
||||
S7 200 cpu type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.CpuType.S7300">
|
||||
<summary>
|
||||
S7 300 cpu type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.CpuType.S7400">
|
||||
<summary>
|
||||
S7 400 cpu type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.CpuType.S71200">
|
||||
<summary>
|
||||
S7 1200 cpu type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.CpuType.S71500">
|
||||
<summary>
|
||||
S7 1500 cpu type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.ErrorCode">
|
||||
<summary>
|
||||
Types of error code that can be set after a function is called
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.NoError">
|
||||
<summary>
|
||||
The function has been executed correctly
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.WrongCPU_Type">
|
||||
<summary>
|
||||
Wrong type of CPU error
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.ConnectionError">
|
||||
<summary>
|
||||
Connection error
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.IPAddressNotAvailable">
|
||||
<summary>
|
||||
Ip address not available
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.WrongVarFormat">
|
||||
<summary>
|
||||
Wrong format of the variable
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.WrongNumberReceivedBytes">
|
||||
<summary>
|
||||
Wrong number of received bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.SendData">
|
||||
<summary>
|
||||
Error on send data
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.ReadData">
|
||||
<summary>
|
||||
Error on read data
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.ErrorCode.WriteData">
|
||||
<summary>
|
||||
Error on write data
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.DataType">
|
||||
<summary>
|
||||
Types of memory area that can be read
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.DataType.Input">
|
||||
<summary>
|
||||
Input area memory
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.DataType.Output">
|
||||
<summary>
|
||||
Output area memory
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.DataType.Memory">
|
||||
<summary>
|
||||
Merkers area memory (M0, M0.0, ...)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.DataType.DataBlock">
|
||||
<summary>
|
||||
DB area memory (DB1, DB2, ...)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.DataType.Timer">
|
||||
<summary>
|
||||
Timer area memory(T1, T2, ...)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.DataType.Counter">
|
||||
<summary>
|
||||
Counter area memory (C1, C2, ...)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.VarType">
|
||||
<summary>
|
||||
Types
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Bit">
|
||||
<summary>
|
||||
S7 Bit variable type (bool)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Byte">
|
||||
<summary>
|
||||
S7 Byte variable type (8 bits)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Word">
|
||||
<summary>
|
||||
S7 Word variable type (16 bits, 2 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.DWord">
|
||||
<summary>
|
||||
S7 DWord variable type (32 bits, 4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Int">
|
||||
<summary>
|
||||
S7 Int variable type (16 bits, 2 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.DInt">
|
||||
<summary>
|
||||
DInt variable type (32 bits, 4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Real">
|
||||
<summary>
|
||||
Real variable type (32 bits, 4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.String">
|
||||
<summary>
|
||||
String variable type (variable)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.StringEx">
|
||||
<summary>
|
||||
String variable type (variable)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Timer">
|
||||
<summary>
|
||||
Timer variable type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="F:S7.Net.VarType.Counter">
|
||||
<summary>
|
||||
Counter variable type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Plc">
|
||||
<summary>
|
||||
Creates an instance of S7.Net driver
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.IP">
|
||||
<summary>
|
||||
IP address of the PLC
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.CPU">
|
||||
<summary>
|
||||
CPU type of the PLC
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.Rack">
|
||||
<summary>
|
||||
Rack of the PLC
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.Slot">
|
||||
<summary>
|
||||
Slot of the CPU of the PLC
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.MaxPDUSize">
|
||||
<summary>
|
||||
Max PDU size this cpu supports
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.IsAvailable">
|
||||
<summary>
|
||||
Returns true if a connection to the PLC can be established
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.IsConnected">
|
||||
<summary>
|
||||
Checks if the socket is connected and polls the other peer (the PLC) to see if it's connected.
|
||||
This is the variable that you should continously check to see if the communication is working
|
||||
See also: http://stackoverflow.com/questions/2661764/how-to-check-if-a-socket-is-connected-disconnected-in-c
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.LastErrorString">
|
||||
<summary>
|
||||
Contains the last error registered when executing a function
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Plc.LastErrorCode">
|
||||
<summary>
|
||||
Contains the last error code registered when executing a function
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.#ctor(S7.Net.CpuType,System.String,System.Int16,System.Int16)">
|
||||
<summary>
|
||||
Creates a PLC object with all the parameters needed for connections.
|
||||
For S7-1200 and S7-1500, the default is rack = 0 and slot = 0.
|
||||
You need slot > 0 if you are connecting to external ethernet card (CP).
|
||||
For S7-300 and S7-400 the default is rack = 0 and slot = 2.
|
||||
</summary>
|
||||
<param name="cpu">CpuType of the PLC (select from the enum)</param>
|
||||
<param name="ip">Ip address of the PLC</param>
|
||||
<param name="rack">rack of the PLC, usually it's 0, but check in the hardware configuration of Step7 or TIA portal</param>
|
||||
<param name="slot">slot of the CPU of the PLC, usually it's 2 for S7300-S7400, 0 for S7-1200 and S7-1500.
|
||||
If you use an external ethernet card, this must be set accordingly.</param>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Open">
|
||||
<summary>
|
||||
Open a <see cref="T:System.Net.Sockets.Socket"/> and connects to the PLC, sending all the corrected package
|
||||
and returning if the connection was successful (<see cref="F:S7.Net.ErrorCode.NoError"/>) of it was wrong.
|
||||
</summary>
|
||||
<returns>Returns ErrorCode.NoError if the connection was successful, otherwise check the ErrorCode</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Close">
|
||||
<summary>
|
||||
Disonnects from the PLC and close the socket
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadMultipleVars(System.Collections.Generic.List{S7.Net.Types.DataItem})">
|
||||
<summary>
|
||||
Reads multiple vars in a single request.
|
||||
You have to create and pass a list of DataItems and you obtain in response the same list with the values.
|
||||
Values are stored in the property "Value" of the dataItem and are already converted.
|
||||
If you don't want the conversion, just create a dataItem of bytes.
|
||||
DataItems must not be more than 20 (protocol restriction) and bytes must not be more than 200 + 22 of header (protocol restriction).
|
||||
</summary>
|
||||
<param name="dataItems">List of dataitems that contains the list of variables that must be read. Maximum 20 dataitems are accepted.</param>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadBytes(S7.Net.DataType,System.Int32,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Reads a number of bytes from a DB starting from a specified index. This handles more than 200 bytes with multiple requests.
|
||||
If the read was not successful, check LastErrorCode or LastErrorString.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<param name="count">Byte count, if you want to read 120 bytes, set this to 120.</param>
|
||||
<returns>Returns the bytes in an array</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Read(S7.Net.DataType,System.Int32,System.Int32,S7.Net.VarType,System.Int32,System.Byte)">
|
||||
<summary>
|
||||
Read and decode a certain number of bytes of the "VarType" provided.
|
||||
This can be used to read multiple consecutive variables of the same type (Word, DWord, Int, etc).
|
||||
If the read was not successful, check LastErrorCode or LastErrorString.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<param name="varType">Type of the variable/s that you are reading</param>
|
||||
<param name="bitAdr">Address of bit. If you want to read DB1.DBX200.6, set 6 to this parameter.</param>
|
||||
<param name="varCount"></param>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Read(System.String)">
|
||||
<summary>
|
||||
Reads a single variable from the PLC, takes in input strings like "DB1.DBX0.0", "DB20.DBD200", "MB20", "T45", etc.
|
||||
If the read was not successful, check LastErrorCode or LastErrorString.
|
||||
</summary>
|
||||
<param name="variable">Input strings like "DB1.DBX0.0", "DB20.DBD200", "MB20", "T45", etc.</param>
|
||||
<returns>Returns an object that contains the value. This object must be cast accordingly.</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadStruct(System.Type,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Reads all the bytes needed to fill a struct in C#, starting from a certain address, and return an object that can be casted to the struct.
|
||||
</summary>
|
||||
<param name="structType">Type of the struct to be readed (es.: TypeOf(MyStruct)).</param>
|
||||
<param name="db">Address of the DB.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<returns>Returns a struct that must be cast.</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadStruct``1(System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Reads all the bytes needed to fill a struct in C#, starting from a certain address, and returns the struct or null if nothing was read.
|
||||
</summary>
|
||||
<typeparam name="T">The struct type</typeparam>
|
||||
<param name="db">Address of the DB.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<returns>Returns a nulable struct. If nothing was read null will be returned.</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadClass(System.Object,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Reads all the bytes needed to fill a class in C#, starting from a certain address, and set all the properties values to the value that are read from the PLC.
|
||||
This reads only properties, it doesn't read private variable or public variable without {get;set;} specified.
|
||||
</summary>
|
||||
<param name="sourceClass">Instance of the class that will store the values</param>
|
||||
<param name="db">Index of the DB; es.: 1 is for DB1</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<returns>The number of read bytes</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadClass``1(System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Reads all the bytes needed to fill a class in C#, starting from a certain address, and set all the properties values to the value that are read from the PLC.
|
||||
This reads only properties, it doesn't read private variable or public variable without {get;set;} specified. To instantiate the class defined by the generic
|
||||
type, the class needs a default constructor.
|
||||
</summary>
|
||||
<typeparam name="T">The class that will be instantiated. Requires a default constructor</typeparam>
|
||||
<param name="db">Index of the DB; es.: 1 is for DB1</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<returns>An instance of the class with the values read from the PLC. If no data has been read, null will be returned</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadClass``1(System.Func{``0},System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Reads all the bytes needed to fill a class in C#, starting from a certain address, and set all the properties values to the value that are read from the PLC.
|
||||
This reads only properties, it doesn't read private variable or public variable without {get;set;} specified.
|
||||
</summary>
|
||||
<typeparam name="T">The class that will be instantiated</typeparam>
|
||||
<param name="classFactory">Function to instantiate the class</param>
|
||||
<param name="db">Index of the DB; es.: 1 is for DB1</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<returns>An instance of the class with the values read from the PLC. If no data has been read, null will be returned</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.WriteBytes(S7.Net.DataType,System.Int32,System.Int32,System.Byte[])">
|
||||
<summary>
|
||||
Write a number of bytes from a DB starting from a specified index. This handles more than 200 bytes with multiple requests.
|
||||
If the write was not successful, check LastErrorCode or LastErrorString.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to write DB1.DBW200, this is 200.</param>
|
||||
<param name="value">Bytes to write. If more than 200, multiple requests will be made.</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.WriteBit(S7.Net.DataType,System.Int32,System.Int32,System.Int32,System.Boolean)">
|
||||
<summary>
|
||||
Write a single bit from a DB with the specified index.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to write DB1.DBW200, this is 200.</param>
|
||||
<param name="bitAdr">The address of the bit. (0-7)</param>
|
||||
<param name="value">Bytes to write. If more than 200, multiple requests will be made.</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.WriteBit(S7.Net.DataType,System.Int32,System.Int32,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Write a single bit from a DB with the specified index.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to write DB1.DBW200, this is 200.</param>
|
||||
<param name="bitAdr">The address of the bit. (0-7)</param>
|
||||
<param name="value">Bytes to write. If more than 200, multiple requests will be made.</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Write(S7.Net.DataType,System.Int32,System.Int32,System.Object,System.Int32)">
|
||||
<summary>
|
||||
Takes in input an object and tries to parse it to an array of values. This can be used to write many data, all of the same type.
|
||||
You must specify the memory area type, memory are address, byte start address and bytes count.
|
||||
If the read was not successful, check LastErrorCode or LastErrorString.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<param name="value">Bytes to write. The lenght of this parameter can't be higher than 200. If you need more, use recursion.</param>
|
||||
<param name="bitAdr">The address of the bit. (0-7)</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Write(System.String,System.Object)">
|
||||
<summary>
|
||||
Writes a single variable from the PLC, takes in input strings like "DB1.DBX0.0", "DB20.DBD200", "MB20", "T45", etc.
|
||||
If the write was not successful, check <see cref="P:S7.Net.Plc.LastErrorCode"/> or <see cref="P:S7.Net.Plc.LastErrorString"/>.
|
||||
</summary>
|
||||
<param name="variable">Input strings like "DB1.DBX0.0", "DB20.DBD200", "MB20", "T45", etc.</param>
|
||||
<param name="value">Value to be written to the PLC</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.WriteStruct(System.Object,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Writes a C# struct to a DB in the PLC
|
||||
</summary>
|
||||
<param name="structValue">The struct to be written</param>
|
||||
<param name="db">Db address</param>
|
||||
<param name="startByteAdr">Start bytes on the PLC</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.WriteClass(System.Object,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Writes a C# class to a DB in the PLC
|
||||
</summary>
|
||||
<param name="classValue">The class to be written</param>
|
||||
<param name="db">Db address</param>
|
||||
<param name="startByteAdr">Start bytes on the PLC</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ClearLastError">
|
||||
<summary>
|
||||
Sets the <see cref="P:S7.Net.Plc.LastErrorCode"/> to <see cref="F:S7.Net.ErrorCode.NoError"/> and <see cref="P:S7.Net.Plc.LastErrorString"/> to <see cref="F:System.String.Empty"/>.
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ReadHeaderPackage(System.Int32)">
|
||||
<summary>
|
||||
Creates the header to read bytes from the PLC
|
||||
</summary>
|
||||
<param name="amount"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.CreateReadDataRequestPackage(S7.Net.DataType,System.Int32,System.Int32,System.Int32)">
|
||||
<summary>
|
||||
Create the bytes-package to request data from the PLC. You have to specify the memory type (dataType),
|
||||
the address of the memory, the address of the byte and the bytes count.
|
||||
</summary>
|
||||
<param name="dataType">MemoryType (DB, Timer, Counter, etc.)</param>
|
||||
<param name="db">Address of the memory to be read</param>
|
||||
<param name="startByteAdr">Start address of the byte</param>
|
||||
<param name="count">Number of bytes to be read</param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.WriteBytesWithASingleRequest(S7.Net.DataType,System.Int32,System.Int32,System.Byte[])">
|
||||
<summary>
|
||||
Writes up to 200 bytes to the PLC and returns NoError if successful. You must specify the memory area type, memory are address, byte start address and bytes count.
|
||||
If the write was not successful, check LastErrorCode or LastErrorString.
|
||||
</summary>
|
||||
<param name="dataType">Data type of the memory area, can be DB, Timer, Counter, Merker(Memory), Input, Output.</param>
|
||||
<param name="db">Address of the memory area (if you want to read DB1, this is set to 1). This must be set also for other memory area types: counters, timers,etc.</param>
|
||||
<param name="startByteAdr">Start byte address. If you want to read DB1.DBW200, this is 200.</param>
|
||||
<param name="value">Bytes to write. The lenght of this parameter can't be higher than 200. If you need more, use recursion.</param>
|
||||
<returns>NoError if it was successful, or the error is specified</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.ParseBytes(S7.Net.VarType,System.Byte[],System.Int32,System.Byte)">
|
||||
<summary>
|
||||
Given a S7 variable type (Bool, Word, DWord, etc.), it converts the bytes in the appropriate C# format.
|
||||
</summary>
|
||||
<param name="varType"></param>
|
||||
<param name="bytes"></param>
|
||||
<param name="varCount"></param>
|
||||
<param name="bitAdr"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.VarTypeToByteLength(S7.Net.VarType,System.Int32)">
|
||||
<summary>
|
||||
Given a S7 <see cref="T:S7.Net.VarType"/> (Bool, Word, DWord, etc.), it returns how many bytes to read.
|
||||
</summary>
|
||||
<param name="varType"></param>
|
||||
<param name="varCount"></param>
|
||||
<returns>Byte lenght of variable</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Dispose(System.Boolean)">
|
||||
<summary>
|
||||
Releases all resources, disonnects from the PLC and closes the <see cref="T:System.Net.Sockets.Socket"/>
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Plc.Dispose">
|
||||
<summary>
|
||||
Releases all resources, disonnects from the PLC and closes the <see cref="T:System.Net.Sockets.Socket"/>
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.TPKT">
|
||||
<summary>
|
||||
Describes a TPKT Packet
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.TPKT.Read(System.Net.Sockets.Socket)">
|
||||
<summary>
|
||||
Reds a TPKT from the socket
|
||||
</summary>
|
||||
<param name="socket">The socket to read from</param>
|
||||
<returns>TPKT Instace</returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Bit">
|
||||
<summary>
|
||||
Contains the conversion methods to convert Bit from S7 plc to C#.
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Bit.FromByte(System.Byte,System.Byte)">
|
||||
<summary>
|
||||
Converts a Bit to bool
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Bit.ToBitArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of bytes to a BitArray
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Boolean">
|
||||
<summary>
|
||||
Contains the methods to read, set and reset bits inside bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Boolean.GetValue(System.Byte,System.Int32)">
|
||||
<summary>
|
||||
Returns the value of a bit in a bit, given the address of the bit
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Boolean.SetBit(System.Byte,System.Int32)">
|
||||
<summary>
|
||||
Sets the value of a bit to 1 (true), given the address of the bit
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Boolean.ClearBit(System.Byte,System.Int32)">
|
||||
<summary>
|
||||
Resets the value of a bit to 0 (false), given the address of the bit
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Byte">
|
||||
<summary>
|
||||
Contains the methods to convert from bytes to byte arrays
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Byte.ToByteArray(System.Byte)">
|
||||
<summary>
|
||||
Converts a byte to byte array
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Byte.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a byte array to byte
|
||||
</summary>
|
||||
<param name="bytes"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Class">
|
||||
<summary>
|
||||
Contains the methods to convert a C# class to S7 data types
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Class.GetClassSize(System.Object)">
|
||||
<summary>
|
||||
Gets the size of the class in bytes.
|
||||
</summary>
|
||||
<param name="instance">An instance of the class</param>
|
||||
<returns>the number of bytes</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Class.FromBytes(System.Object,System.Byte[])">
|
||||
<summary>
|
||||
Sets the object's values with the given array of bytes
|
||||
</summary>
|
||||
<param name="sourceClass">The object to fill in the given array of bytes</param>
|
||||
<param name="bytes">The array of bytes</param>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Class.ToBytes(System.Object)">
|
||||
<summary>
|
||||
Creates a byte array depending on the struct type.
|
||||
</summary>
|
||||
<param name="sourceClass">The struct object</param>
|
||||
<returns>A byte array or null if fails.</returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Counter">
|
||||
<summary>
|
||||
Contains the conversion methods to convert Counter from S7 plc to C# ushort (UInt16).
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Counter.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a Counter (2 bytes) to ushort (UInt16)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Counter.ToByteArray(System.UInt16)">
|
||||
<summary>
|
||||
Converts a ushort (UInt16) to word (2 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Counter.ToByteArray(System.UInt16[])">
|
||||
<summary>
|
||||
Converts an array of ushort (UInt16) to an array of bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Counter.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of bytes to an array of ushort
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.DataItem">
|
||||
<summary>
|
||||
Create an instance of a memory block that can be read by using ReadMultipleVars
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.DataType">
|
||||
<summary>
|
||||
Memory area to read
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.VarType">
|
||||
<summary>
|
||||
Type of data to be read (default is bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.DB">
|
||||
<summary>
|
||||
Address of memory area to read (example: for DB1 this value is 1, for T45 this value is 45)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.StartByteAdr">
|
||||
<summary>
|
||||
Address of the first byte to read
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.BitAdr">
|
||||
<summary>
|
||||
Addess of bit to read from StartByteAdr
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.Count">
|
||||
<summary>
|
||||
Number of variables to read
|
||||
</summary>
|
||||
</member>
|
||||
<member name="P:S7.Net.Types.DataItem.Value">
|
||||
<summary>
|
||||
Contains the value of the memory area after the read has been executed
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DataItem.#ctor">
|
||||
<summary>
|
||||
Create an instance of DataItem
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.DInt">
|
||||
<summary>
|
||||
Contains the conversion methods to convert DInt from S7 plc to C# int (Int32).
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DInt.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a S7 DInt (4 bytes) to int (Int32)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DInt.ToByteArray(System.Int32)">
|
||||
<summary>
|
||||
Converts a int (Int32) to S7 DInt (4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DInt.ToByteArray(System.Int32[])">
|
||||
<summary>
|
||||
Converts an array of int (Int32) to an array of bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DInt.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of S7 DInt to an array of int (Int32)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Double">
|
||||
<summary>
|
||||
Contains the conversion methods to convert Real from S7 plc to C# double.
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Double.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a S7 Real (4 bytes) to double
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Double.FromDWord(System.Int32)">
|
||||
<summary>
|
||||
Converts a S7 DInt to double
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Double.FromDWord(System.UInt32)">
|
||||
<summary>
|
||||
Converts a S7 DWord to double
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Double.ToByteArray(System.Double)">
|
||||
<summary>
|
||||
Converts a double to S7 Real (4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Double.ToByteArray(System.Double[])">
|
||||
<summary>
|
||||
Converts an array of double to an array of bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Double.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of S7 Real to an array of double
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.DWord">
|
||||
<summary>
|
||||
Contains the conversion methods to convert DWord from S7 plc to C#.
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DWord.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a S7 DWord (4 bytes) to uint (UInt32)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DWord.FromBytes(System.Byte,System.Byte,System.Byte,System.Byte)">
|
||||
<summary>
|
||||
Converts 4 bytes to DWord (UInt32)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DWord.ToByteArray(System.UInt32)">
|
||||
<summary>
|
||||
Converts a uint (UInt32) to S7 DWord (4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DWord.ToByteArray(System.UInt32[])">
|
||||
<summary>
|
||||
Converts an array of uint (UInt32) to an array of S7 DWord (4 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.DWord.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of S7 DWord to an array of uint (UInt32)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Int">
|
||||
<summary>
|
||||
Contains the conversion methods to convert Int from S7 plc to C#.
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Int.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a S7 Int (2 bytes) to short (Int16)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Int.ToByteArray(System.Int16)">
|
||||
<summary>
|
||||
Converts a short (Int16) to a S7 Int byte array (2 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Int.ToByteArray(System.Int16[])">
|
||||
<summary>
|
||||
Converts an array of short (Int16) to a S7 Int byte array (2 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Int.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of S7 Int to an array of short (Int16)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Int.CWord(System.Int32)">
|
||||
<summary>
|
||||
Converts a C# int value to a C# short value, to be used as word.
|
||||
</summary>
|
||||
<param name="value"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.StringEx">
|
||||
<summary>
|
||||
Contains the methods to convert from S7 strings to C# strings
|
||||
there are two kinds how strings a send. This one is with a pre of two bytes
|
||||
they contain the length of the string
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.StringEx.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts S7 bytes to a string
|
||||
</summary>
|
||||
<param name="bytes"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.String">
|
||||
<summary>
|
||||
Contains the methods to convert from S7 strings to C# strings
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.String.ToByteArray(System.String)">
|
||||
<summary>
|
||||
Converts a string to S7 bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.String.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts S7 bytes to a string
|
||||
</summary>
|
||||
<param name="bytes"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Struct">
|
||||
<summary>
|
||||
Contains the method to convert a C# struct to S7 data types
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Struct.GetStructSize(System.Type)">
|
||||
<summary>
|
||||
Gets the size of the struct in bytes.
|
||||
</summary>
|
||||
<param name="structType">the type of the struct</param>
|
||||
<returns>the number of bytes</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Struct.FromBytes(System.Type,System.Byte[])">
|
||||
<summary>
|
||||
Creates a struct of a specified type by an array of bytes.
|
||||
</summary>
|
||||
<param name="structType">The struct type</param>
|
||||
<param name="bytes">The array of bytes</param>
|
||||
<returns>The object depending on the struct type or null if fails(array-length != struct-length</returns>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Struct.ToBytes(System.Object)">
|
||||
<summary>
|
||||
Creates a byte array depending on the struct type.
|
||||
</summary>
|
||||
<param name="structValue">The struct object</param>
|
||||
<returns>A byte array or null if fails.</returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Timer">
|
||||
<summary>
|
||||
Converts the Timer data type to C# data type
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Timer.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts the timer bytes to a double
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Timer.ToByteArray(System.UInt16)">
|
||||
<summary>
|
||||
Converts a ushort (UInt16) to an array of bytes formatted as time
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Timer.ToByteArray(System.UInt16[])">
|
||||
<summary>
|
||||
Converts an array of ushorts (Uint16) to an array of bytes formatted as time
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Timer.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of bytes formatted as time to an array of doubles
|
||||
</summary>
|
||||
<param name="bytes"></param>
|
||||
<returns></returns>
|
||||
</member>
|
||||
<member name="T:S7.Net.Types.Word">
|
||||
<summary>
|
||||
Contains the conversion methods to convert Words from S7 plc to C#.
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Word.FromByteArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts a word (2 bytes) to ushort (UInt16)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Word.FromBytes(System.Byte,System.Byte)">
|
||||
<summary>
|
||||
Converts 2 bytes to ushort (UInt16)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Word.ToByteArray(System.UInt16)">
|
||||
<summary>
|
||||
Converts a ushort (UInt16) to word (2 bytes)
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Word.ToByteArray(System.UInt16[])">
|
||||
<summary>
|
||||
Converts an array of ushort (UInt16) to an array of bytes
|
||||
</summary>
|
||||
</member>
|
||||
<member name="M:S7.Net.Types.Word.ToArray(System.Byte[])">
|
||||
<summary>
|
||||
Converts an array of bytes to an array of ushort
|
||||
</summary>
|
||||
</member>
|
||||
</members>
|
||||
</doc>
|
||||
@@ -0,0 +1,76 @@
|
||||
2020-05-11 15:31:55.2752 [INFO] SiemensProxy|Starting loadMemConf
|
||||
2020-05-11 15:31:55.2992 [INFO] SiemensProxy|File found: setup.json
|
||||
2020-05-11 15:31:55.4292 [INFO] SiemensProxy|Completed data deserialization
|
||||
2020-05-11 15:31:55.4292 [INFO] SiemensProxy|Refreshing connection...
|
||||
2020-05-11 15:31:55.4373 [INFO] SiemensProxy|PLC parameters: CPU S71500 | IP: 192.168.0.102 | R/S: 0/1
|
||||
2020-05-11 15:31:55.4562 [INFO] SiemensProxy|PLC Connected!
|
||||
2020-05-11 15:31:56.4546 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:31:56.4546 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:32:07.4534 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:32:07.4534 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,0590123456
|
||||
2020-05-11 15:32:15.4538 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:32:15.4538 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:38:00.9798 [INFO] SiemensProxy|Starting loadMemConf
|
||||
2020-05-11 15:38:01.0108 [INFO] SiemensProxy|File found: setup.json
|
||||
2020-05-11 15:38:01.2019 [INFO] SiemensProxy|Completed data deserialization
|
||||
2020-05-11 15:38:01.2049 [INFO] SiemensProxy|Refreshing connection...
|
||||
2020-05-11 15:38:01.2049 [INFO] SiemensProxy|PLC parameters: CPU S71500 | IP: 192.168.0.102 | R/S: 0/1
|
||||
2020-05-11 15:38:01.2269 [INFO] SiemensProxy|PLC Connected!
|
||||
2020-05-11 15:38:02.2381 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:38:02.2511 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:43:41.9572 [INFO] SiemensProxy|Starting loadMemConf
|
||||
2020-05-11 15:43:41.9812 [INFO] SiemensProxy|File found: setup.json
|
||||
2020-05-11 15:43:42.1132 [INFO] SiemensProxy|Completed data deserialization
|
||||
2020-05-11 15:43:42.1132 [INFO] SiemensProxy|Refreshing connection...
|
||||
2020-05-11 15:43:42.1132 [INFO] SiemensProxy|PLC parameters: CPU S71500 | IP: 192.168.0.102 | R/S: 0/1
|
||||
2020-05-11 15:43:42.1342 [INFO] SiemensProxy|PLC Connected!
|
||||
2020-05-11 15:43:43.1269 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:43:43.1269 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:43:54.1265 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:43:54.1265 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059000012
|
||||
2020-05-11 15:43:59.1273 [INFO] SiemensProxy|New Value found
|
||||
2020-05-11 15:43:59.1273 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:50:57.6835 [INFO] SiemensProxy|Starting loadMemConf
|
||||
2020-05-11 15:50:57.7075 [INFO] SiemensProxy|File found: setup.json
|
||||
2020-05-11 15:50:57.8356 [INFO] SiemensProxy|Completed data deserialization
|
||||
2020-05-11 15:50:57.8356 [INFO] SiemensProxy|Refreshing connection...
|
||||
2020-05-11 15:50:57.8356 [INFO] SiemensProxy|PLC parameters: CPU S71500 | IP: 192.168.0.102 | R/S: 0/1
|
||||
2020-05-11 15:50:57.8556 [INFO] SiemensProxy|PLC Connected!
|
||||
2020-05-11 15:50:58.8460 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:50:58.8460 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:51:14.8462 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:51:14.8462 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,0590123
|
||||
2020-05-11 15:51:18.8447 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:51:18.8447 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,0590123456
|
||||
2020-05-11 15:51:22.8449 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:51:22.8449 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:52:05.8803 [INFO] SiemensProxy|Starting loadMemConf
|
||||
2020-05-11 15:52:05.9033 [INFO] SiemensProxy|File found: setup.json
|
||||
2020-05-11 15:52:06.0293 [INFO] SiemensProxy|Completed data deserialization
|
||||
2020-05-11 15:52:06.0293 [INFO] SiemensProxy|Refreshing connection...
|
||||
2020-05-11 15:52:06.0373 [INFO] SiemensProxy|PLC parameters: CPU S71500 | IP: 192.168.0.102 | R/S: 0/1
|
||||
2020-05-11 15:52:06.0513 [INFO] SiemensProxy|PLC Connected!
|
||||
2020-05-11 15:52:07.0508 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:07.0628 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:52:13.0476 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:13.0476 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,05901
|
||||
2020-05-11 15:52:14.0489 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:14.0489 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059012
|
||||
2020-05-11 15:52:17.0470 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:17.0470 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,0590123
|
||||
2020-05-11 15:52:19.0472 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:19.0472 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:52:22.0476 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:22.0476 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 15:52:26.0479 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 15:52:26.0479 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 16:32:45.3067 [INFO] SiemensProxy|Starting loadMemConf
|
||||
2020-05-11 16:32:45.3467 [INFO] SiemensProxy|File found: setup.json
|
||||
2020-05-11 16:32:45.5197 [INFO] SiemensProxy|Completed data deserialization
|
||||
2020-05-11 16:32:45.5197 [INFO] SiemensProxy|Refreshing connection...
|
||||
2020-05-11 16:32:45.5197 [INFO] SiemensProxy|PLC parameters: CPU S71500 | IP: 192.168.0.102 | R/S: 0/1
|
||||
2020-05-11 16:32:45.5477 [INFO] SiemensProxy|PLC Connected!
|
||||
2020-05-11 16:32:46.5509 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 16:32:46.5669 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059
|
||||
2020-05-11 16:33:01.5498 [INFO] SiemensProxy|Data Change on File
|
||||
2020-05-11 16:33:01.5498 [INFO] SiemensProxy|Value sent to PLC: DB999.DBD32 | 0,059011111
|
||||
@@ -0,0 +1,12 @@
|
||||
Nella cartella Steamware sono contenuti
|
||||
|
||||
- DotNet SDK 4.0 (sono riuscito ad installare solo il 4.0 compact)
|
||||
- versione applicativo per 4.0 compact
|
||||
|
||||
Va configurato l'indirizzo del PLC nel file
|
||||
|
||||
C:\SteamWare\MHT-Siemens-4\setup.json
|
||||
|
||||
In particolare va indicata area di memoria e indirizzo IP
|
||||
|
||||
ho lasciato 2 file di esempio per test in Steamware e epr PRESUNTO ip PLC in macchina (da verificare IP)
|
||||
@@ -0,0 +1,19 @@
|
||||
{
|
||||
"csvFilePath": "c:\\zz\\prova1.csv",
|
||||
"csvHasHeader": true,
|
||||
"csvSeparator": ";",
|
||||
"confPLC": {
|
||||
"ipAdrr": "192.168.100.1",
|
||||
"tipoCpu": "S71500",
|
||||
"rack": 0,
|
||||
"slot": 1
|
||||
},
|
||||
"parametersList": {
|
||||
"DB999.DBD32": {
|
||||
"Column": "Valore assoluto",
|
||||
"Index": 7,
|
||||
"MemConf": "DB701.DBD142",
|
||||
"DataType": "real"
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,19 @@
|
||||
{
|
||||
"csvFilePath": "c:\\zz\\prova1.csv",
|
||||
"csvHasHeader": true,
|
||||
"csvSeparator": ";",
|
||||
"confPLC": {
|
||||
"ipAdrr": "192.168.0.102",
|
||||
"tipoCpu": "S71500",
|
||||
"rack": 0,
|
||||
"slot": 1
|
||||
},
|
||||
"parametersList": {
|
||||
"DB999.DBD32": {
|
||||
"Column": "Valore assoluto",
|
||||
"Index": 7,
|
||||
"MemConf": "DB999.DBD32",
|
||||
"DataType": "real"
|
||||
}
|
||||
}
|
||||
}
|
||||
Binary file not shown.
Binary file not shown.
Binary file not shown.
Reference in New Issue
Block a user