INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1001,'Mechanical','Whole',1020,'MaintServ','CycleProc01','Maintenance of speed reducers.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1002,'Mechanical','Whole',170,'MaintServ','CycleProc01','Maintenance shaft supports and lubrication.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1003,'Mechanical','Whole',170,'MaintServ','CycleProc01','Maintenance of the linear guides and of the ball screws.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1004,'Mechanical','Whole',1020,'MaintServ','MacPowerOn','Maintenance of transmission belts.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1005,'Mechanical','Whole',1020,'MaintServ','MacPowerOn','Maintenance flexible/rigid couplings.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1006,'Mechanical','Whole',1020,'MaintServ','MacPowerOn','Maintenance locking devices.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1007,'Mechanical','Whole',1020,'MaintServ','MacPowerOn','Maintenance keys and fasteners.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1008,'Mechanical','Whole',2040,'MaintServ','CycleProc01','Inspect and adjust machine geometry. Calibrate systems that require it.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1101,'Electro','Whole',2040,'MaintServ','CycleProc01','Maintenance on the electric motors.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1102,'Electro','Whole',1020,'MaintServ','MacPowerOn','Maintenance of the electrical system.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1103,'Electro','Cabinet',510,'MaintServ','MacPowerOn','Check programmable controller functionality (PLC).');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1104,'Electro','Cabinet',2040,'MaintServ','MacPowerOn','Periodic maintenance of the Cabinet ventilation system.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1105,'Electro','OpPanel',40,'MaintServ','MacPowerOn','Cleaning the control panel air conditioners.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1106,'Electro','Cabinet',510,'MaintServ','MacPowerOn','Checking the auxiliary batteries.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1107,'Electro','Axis',170,'MaintServ','SpindleTorque01','Maintenance of electro-spindle 1.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1108,'Electro','Axis',170,'MaintServ','SpindleTorque02','Maintenance of electro-spindle 2.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1109,'Electro','Axis',170,'MaintServ','SpindleTorque03','Maintenance of electro-spindle 3.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1110,'Electro','Axis',170,'MaintServ','SpindleTorque04','Maintenance of electro-spindle 4.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1201,'Preumo','Whole',1020,'MaintServ','MacPowerOn','Check pressure switch.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1202,'Preumo','Whole',2040,'MaintServ','MacPowerOn','Maintenance of the FR and FRL units.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1203,'Preumo','Whole',2040,'MaintServ','CycleProc01','Maintenance of the pneumatic valves and solenoid valves.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1204,'Preumo','Whole',2040,'MaintServ','CycleProc01','Maintenance of the pneumatic cylinders.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1301,'Lubro','Whole',170,'TrainOp','MacPowerOn','Manually lubricate or grease systems that require it.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1401,'Hydro','Whole',2040,'MaintServ','MacPowerOn','Maintenance of hydraulic system.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1402,'Hydro','Whole','2000','MaintServ','MacPowerOn','Replacing the oil.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1403,'Hydro','Whole',1020,'MaintServ','MacPowerOn','Check piping.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1404,'Hydro','Whole',1020,'MaintServ','MacPowerOn','External inspection of tanks and steel components.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1501,'Safety','Whole',1020,'MaintServ','MacPowerOn','Check the safety signs.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1502,'Safety','Whole',1020,'MaintServ','MacPowerOn','Check emergency buttons.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1503,'Safety','Whole',1020,'MaintServ','MacPowerOn','Check interlock switches with electromagnet and RFID technology and with guard locking.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1504,'Safety','Whole',1020,'MaintServ','MacPowerOn','Check interlock switches for hinges.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1505,'Safety','Whole',1020,'MaintServ','MacPowerOn','Check safety modules.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1506,'Safety','Whole',1020,'MaintServ','MacPowerOn','Check guards.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1507,'Safety','OpPanel',1020,'MaintServ','MacPowerOn','Check PITmode operating mode selector switch.');
INSERT INTO PrevMaintTask(MachineId,ExtIdx,PMTCode,PMMGCode,ExpiryVal,PMUTCode,CCode,JobDescription) VALUES (1,1508,'Safety','Cabinet',1020,'MaintServ','MacPowerOn','Replace the protection fuses inside Cabinet.');