Update for ThermoCam reading

This commit is contained in:
Samuele Locatelli
2020-10-24 11:39:06 +02:00
parent cd1c87caa1
commit 8dfd2d4d23
3 changed files with 181 additions and 31 deletions
+8 -8
View File
@@ -498,17 +498,17 @@ namespace CMS_CORE_Library.Models
/// <summary>
/// Define if camera is active for channel
/// </summary>
public bool ThermocamActive { get; set; } = false;
public bool TCamActive { get; set; } = false;
/// <summary>
/// Actual value from last ThermoCam image acquisition (° Celsius)
/// Actual value from last ThermoCam image acquisition (1/10 ° Celsius)
/// </summary>
public double ThermocamActualTemp { get; set; } = 0;
public short TCamTempActual { get; set; } = 0;
/// <summary>
/// Setpoint from HMI (° Celsius)
/// Setpoint from HMI (1/10 ° Celsius)
/// </summary>
public byte ThermocamSetpoint { get; set; } = 0;
public short TCamTempSet { get; set; } = 0;
#endregion Properties
@@ -537,11 +537,11 @@ namespace CMS_CORE_Library.Models
return false;
if (SetpointPLC != item.SetpointPLC)
return false;
if (ThermocamActive != item.ThermocamActive)
if (TCamActive != item.TCamActive)
return false;
if (ThermocamActualTemp != item.ThermocamActualTemp)
if (TCamTempActual != item.TCamTempActual)
return false;
if (ThermocamSetpoint != item.ThermocamSetpoint)
if (TCamTempSet != item.TCamTempSet)
return false;
return true;
+2 -1
View File
@@ -674,9 +674,10 @@ namespace CMS_CORE_Library
/// <summary>
/// Get current Warmers Channels list
/// </summary>
/// <param name="useCache">updates only READ parameters (false = update all data)</param>
/// <param name="currWarmerChannelList"></param>
/// <returns></returns>
public abstract CmsError PLC_RWarmerChannelList(ref Dictionary<int, ThermoModels.WarmerChannel> currWarmerChannelList);
public abstract CmsError PLC_RWarmerChannelList(bool useCache, ref Dictionary<int, ThermoModels.WarmerChannel> currWarmerChannelList);
/// <summary>
/// Set current Warmers Channels setpoints
/// </summary>
+171 -22
View File
@@ -2345,26 +2345,34 @@ namespace CMS_CORE_Library.S7Net
/// <summary>
/// Get current Warmers Channels list
/// </summary>
/// <param name="useCache">updates only READ parameters (false = update all data)</param>
/// <param name="currWarmerChannelList"></param>
/// <returns></returns>
public override CmsError PLC_RWarmerChannelList(ref Dictionary<int, ThermoModels.WarmerChannel> currWarmerChannelList)
public override CmsError PLC_RWarmerChannelList(bool useCache, ref Dictionary<int, ThermoModels.WarmerChannel> currWarmerChannelList)
{
// refresh stato canale
// refresh stato canale ESP[i]
refreshRiscStatus();
// refresh % attuale
// refresh % lavoro attuale OVp[i]
refreshRiscPerc();
// refresh setpoint PLC
// refresh corrente attuale Ich[i]
refreshRiscActCurr();
// refresh setpoint HMI
refreshRiscSetpointHMI();
// refresh setpoint PLC
// refresh setpoint PLC % (era 514 --> 627)
refreshRiscSetpointPLC();
// refresh dati termocamera
refreshRiscTermoCamAbilit();
// refresh dati status/comando termocamera
refreshRiscTermoCamCommStatus();
refreshRiscTermoCamTempAct();
refreshRiscTermoCamTempSet();
if (!useCache)
{
// refresh setpoint HMI canale % | Write
refreshRiscSetpointHMI();
// refresh abilitazione canale x thermoCam | Write
refreshRiscTermoCamAbilit();
// refresh ultima temp canale letta da thermoCam | Write
refreshRiscTermoCamTempAct();
// refresh temp canale impostata x thermoCam | Write
refreshRiscTermoCamTempSet();
}
// copio lista act in output
currWarmerChannelList = ThermoWarmChannels;
@@ -2953,28 +2961,170 @@ namespace CMS_CORE_Library.S7Net
/// </summary>
private void refreshRiscTermoCamTempSet()
{
// FIXME TODO ???? da dove prendere info?
// leggo DB624 x Setpoint Temp richiesti
List<short> currMem = new List<short>();
// leggo da PLC a array di byte di appoggio...
CmsError libraryError = MEM_RWShortList(R, 0, TCAM_TEMP_REQ_DATA.MemType, TCAM_TEMP_REQ_DATA.Address, TCAM_TEMP_REQ_DATA.SubAddress, TCAM_TEMP_REQ_DATA.Size / 2, ref currMem);
// copio! controllo SE ho dati...
if (currMem.Count > 0)
{
for (int i = 0; i < TCAM_TEMP_REQ_DATA.Size / 2; i++)
{
// cerco id + 1 (su memoria è base 0)
if (ThermoWarmChannels.ContainsKey(i + 1))
{
try
{
ThermoWarmChannels[i + 1].TCamTempSet = currMem[i];
}
catch
{ }
}
else
{
ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
TCamTempSet = currMem[i]
});
}
}
}
else
{
libraryError = S7_PLC_EMPTY_READ;
}
}
/// <summary>
/// Refresh dati ThermoCamera dal PLC: ultima temp letta
/// </summary>
private void refreshRiscTermoCamTempAct()
{
// FIXME TODO ???? da dove prendere info?
// leggo DB625 x Temp attuale
List<short> currMem = new List<short>();
// leggo da PLC a array di byte di appoggio...
CmsError libraryError = MEM_RWShortList(R, 0, TCAM_TEMP_ACT_DATA.MemType, TCAM_TEMP_ACT_DATA.Address, TCAM_TEMP_ACT_DATA.SubAddress, TCAM_TEMP_ACT_DATA.Size / 2, ref currMem);
// copio! controllo SE ho dati...
if (currMem.Count > 0)
{
for (int i = 0; i < TCAM_TEMP_ACT_DATA.Size / 2; i++)
{
// cerco id + 1 (su memoria è base 0)
if (ThermoWarmChannels.ContainsKey(i + 1))
{
try
{
ThermoWarmChannels[i + 1].TCamTempActual = currMem[i];
}
catch
{ }
}
else
{
ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
TCamTempActual = currMem[i]
});
}
}
}
else
{
libraryError = S7_PLC_EMPTY_READ;
}
}
/// <summary>
/// Refresh dati ThermoCamera dal PLC x area command/status
/// </summary>
private void refreshRiscTermoCamCommStatus()
{
// FIXME TODO ???? da dove prendere info?
#if false
// leggo DB614 x area Ich
List<byte> currMem = new List<byte>();
// leggo da PLC a array di byte di appoggio...
CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
// copio! controllo SE ho dati...
if (currMem.Count > 0)
{
// converto a blocchi di 8 byte...
byte[] memArray = currMem.ToArray();
for (int i = 0; i < RISC_CHP_DATA.Size; i++)
{
// cerco id + 1 (su memoria è base 0)
if (ThermoWarmChannels.ContainsKey(i + 1))
{
try
{
ThermoWarmChannels[i + 1].SetpointHMI = memArray[i];
}
catch
{ }
}
else
{
ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
SetpointHMI = memArray[i]
});
}
}
}
else
{
libraryError = S7_PLC_EMPTY_READ;
}
#endif
}
/// <summary>
/// Refresh dati ThermoCamera dal PLC x area command/status
/// </summary>
private void refreshRiscTermoCamAbilit()
{
// FIXME TODO ???? da dove prendere info?
#if false
// leggo DB664 x abilitazione ch alla termocamera
List<byte> currMem = new List<byte>();
// leggo da PLC a array di byte di appoggio...
CmsError libraryError = MEM_RWByteList(R, 0, TCAM_CH_ENAB_DATA.MemType, TCAM_CH_ENAB_DATA.Address, TCAM_CH_ENAB_DATA.SubAddress, 0, TCAM_CH_ENAB_DATA.Size, ref currMem);
// copio! controllo SE ho dati...
if (currMem.Count > 0)
{
for (int i = 0; i < TCAM_TEMP_ACT_DATA.Size; i++)
{
// cerco id + 1 (su memoria è base 0)
if (ThermoWarmChannels.ContainsKey(i + 1))
{
try
{
ThermoWarmChannels[i + 1].TCamActive = currMem[i];
}
catch
{ }
}
else
{
ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
TCamActive = currMem[i]
});
}
}
}
else
{
libraryError = S7_PLC_EMPTY_READ;
}
#endif
}
/// <summary>
/// Refresh Canali Riscaldi: SetPoint HMI
@@ -3020,11 +3170,11 @@ namespace CMS_CORE_Library.S7Net
}
}
/// <summary>
/// Refresh Canali Riscaldi: SetPoint PLC
/// Refresh Canali Riscaldi: SetPoint PLC (% lavoro applicata ATTUALE dal PLC)
/// </summary>
private void refreshRiscSetpointPLC()
{
// leggo DB514 x area Ich
// leggo area DB627 (era DB514) x area CHp
List<byte> currMem = new List<byte>();
// leggo da PLC a array di byte di appoggio...
@@ -3095,7 +3245,7 @@ namespace CMS_CORE_Library.S7Net
}
}
/// <summary>
/// Refresh Canali Riscaldi: Percentuale Attuale
/// Refresh Canali Riscaldi: Percentuale lavoro Attuale
/// </summary>
private void refreshRiscPerc()
{
@@ -4977,7 +5127,7 @@ namespace CMS_CORE_Library.S7Net
// riscaldi
internal static MEMORY_CELL RISC_VU_MIN = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 513, 0, 2);
internal static MEMORY_CELL RISC_OCC_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 514, 64, 64);
internal static MEMORY_CELL RISC_PLC_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 514, 128, 1024);
internal static MEMORY_CELL RISC_PLC_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 627, 0, 1024); //internal static MEMORY_CELL RISC_PLC_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 514, 128, 1024); //valore PRE thermoCam
internal static MEMORY_CELL RISC_CHP_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 614, 0, 1024);
internal static MEMORY_CELL RISC_CFI_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 514, 2176, 1024);
internal static MEMORY_CELL RISC_ICH_MIN_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 514, 3200, 4096);
@@ -4987,12 +5137,11 @@ namespace CMS_CORE_Library.S7Net
internal static MEMORY_CELL RISC_ICH_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 514, 11776, 4096);
// ThermoCamera
internal static MEMORY_CELL TCAM_STAT_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 626, 0, 2);
internal static MEMORY_CELL TCAM_COMM_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 626, 2, 2);
internal static MEMORY_CELL TCAM_STATW_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 626, 0, 2);
internal static MEMORY_CELL TCAM_COMMW_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 626, 2, 2);
internal static MEMORY_CELL TCAM_CH_ENAB_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 626, 4, 128);
internal static MEMORY_CELL TCAM_TEMP_REQ_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 624, 0, 2048);
internal static MEMORY_CELL TCAM_TEMP_ACT_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 625, 0, 2048);
internal static MEMORY_CELL TCAM_CHP_DATA = new MEMORY_CELL(MEMORY_TYPE.Siemens_DB, 627, 0, 1024);
// produzione