Fix siemens and demo library
This commit is contained in:
@@ -286,12 +286,12 @@ namespace CMS_CORE_Library
|
||||
public class CmsError
|
||||
{
|
||||
public CMS_ERROR_CODES errorCode;
|
||||
public string message;
|
||||
public string localizationKey;
|
||||
|
||||
public CmsError(CMS_ERROR_CODES errorCode, string message)
|
||||
{
|
||||
this.errorCode = errorCode;
|
||||
this.message = message;
|
||||
this.localizationKey = message;
|
||||
}
|
||||
|
||||
public bool IsError()
|
||||
@@ -331,24 +331,26 @@ namespace CMS_CORE_Library
|
||||
MAX_EDGES_PER_TOOL_REACHED = 13,
|
||||
MAX_FAMILY_REACHED = 14,
|
||||
MAX_MULTITOOL_REACHED = 15,
|
||||
MAX_TOOLS_PER_MULTITOOL_REACHED = 16
|
||||
MAX_TOOLS_PER_MULTITOOL_REACHED = 16,
|
||||
MAG_POS_OCCUPIED = 17
|
||||
}
|
||||
|
||||
internal static CmsError NO_ERROR = new CmsError(CMS_ERROR_CODES.OK, "");
|
||||
internal static CmsError NOT_CONNECTED_ERROR = new CmsError(CMS_ERROR_CODES.NOT_CONNECTED, "CMS-Core-Error: Nc not Connected");
|
||||
internal static CmsError PROC_NOT_FOUND_ERROR = new CmsError(CMS_ERROR_CODES.FUNCTION_NOT_ALLOWED, "CMS-Core-Error: Function not allowed for this type of NC");
|
||||
internal static CmsError FUNCTION_NOT_ALLOWED_ERROR = new CmsError(CMS_ERROR_CODES.FUNCTION_NOT_ALLOWED, "CMS-Core-Error: Function not allowed for this type of NC");
|
||||
internal static CmsError BIT_NOT_IN_RANGE_ERROR = new CmsError(CMS_ERROR_CODES.BIT_NOT_IN_RANGE, "CMS-Core-Error: Bit - number must be between 0 and 7");
|
||||
internal static CmsError BYTE_NOT_IN_RANGE_ERROR = new CmsError(CMS_ERROR_CODES.BYTE_NOT_IN_RANGE, "CMS-Core-Error: Byte - number must be between 0 and 1");
|
||||
internal static CmsError INCORRECT_PARAMETERS_ERROR = new CmsError(CMS_ERROR_CODES.INCORRECT_PARAMETERS, "CMS-Core-Error: Incorrect Parameters error");
|
||||
internal static CmsError LANGUAGE_ERROR = new CmsError(CMS_ERROR_CODES.NC_LANGUAGE_ERROR, "CMS-Core-Error: Incorrect Language");
|
||||
internal static CmsError SIEMENS_ENVIRONMENT_NOT_FOUND_ERROR = new CmsError(CMS_ERROR_CODES.SIEMENS_ENVIRONMENT_NOT_FOUND, "CMS-Core-Error: Siemens Environment not found");
|
||||
internal static CmsError SIEMENS_HMI_NOT_RUNNING_ERROR = new CmsError(CMS_ERROR_CODES.SIEMENS_HMI_NOT_RUNNING, "CMS-Core-Error: Siemens HMI is not Running / Ready");
|
||||
internal static CmsError MAX_TOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_TOOL_REACHED, "Max tool number reached");
|
||||
internal static CmsError MAX_EDGES_PER_TOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_EDGES_PER_TOOL_REACHED, "Max edges per tool number reached");
|
||||
internal static CmsError MAX_FAMILY_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_FAMILY_REACHED, "Max family number reached");
|
||||
internal static CmsError MAX_MULTITOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_MULTITOOL_REACHED, "Max multitool number reached");
|
||||
internal static CmsError MAX_TOOLS_PER_MULTITOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_TOOLS_PER_MULTITOOL_REACHED, "Max tool per multitool number reached");
|
||||
internal static CmsError NOT_CONNECTED_ERROR = new CmsError(CMS_ERROR_CODES.NOT_CONNECTED, "error_not_connected");
|
||||
internal static CmsError PROC_NOT_FOUND_ERROR = new CmsError(CMS_ERROR_CODES.FUNCTION_NOT_ALLOWED, "error_process_not_found");
|
||||
internal static CmsError FUNCTION_NOT_ALLOWED_ERROR = new CmsError(CMS_ERROR_CODES.FUNCTION_NOT_ALLOWED, "error_function_not_allowed");
|
||||
internal static CmsError BIT_NOT_IN_RANGE_ERROR = new CmsError(CMS_ERROR_CODES.BIT_NOT_IN_RANGE, "error_bit_not_in_range");
|
||||
internal static CmsError BYTE_NOT_IN_RANGE_ERROR = new CmsError(CMS_ERROR_CODES.BYTE_NOT_IN_RANGE, "error_byte_not_in_range");
|
||||
internal static CmsError INCORRECT_PARAMETERS_ERROR = new CmsError(CMS_ERROR_CODES.INCORRECT_PARAMETERS, "error_incorrect_parameters");
|
||||
internal static CmsError INCORRECT_LANGUAGE_ERROR = new CmsError(CMS_ERROR_CODES.NC_LANGUAGE_ERROR, "error_invalid_language");
|
||||
internal static CmsError SIEMENS_ENVIRONMENT_NOT_FOUND_ERROR = new CmsError(CMS_ERROR_CODES.SIEMENS_ENVIRONMENT_NOT_FOUND, "error_siemens_enviroment_not_found_error");
|
||||
internal static CmsError SIEMENS_HMI_NOT_RUNNING_ERROR = new CmsError(CMS_ERROR_CODES.SIEMENS_HMI_NOT_RUNNING, "error_siemens_hmi_not_running");
|
||||
internal static CmsError MAX_TOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_TOOL_REACHED, "error_max_tool_reached");
|
||||
internal static CmsError MAX_EDGES_PER_TOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_EDGES_PER_TOOL_REACHED, "error_max_edges_per_tool_reached");
|
||||
internal static CmsError MAX_FAMILY_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_FAMILY_REACHED, "error_max_family_reached");
|
||||
internal static CmsError MAX_MULTITOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_MULTITOOL_REACHED, "error_max_multitools_reached");
|
||||
internal static CmsError MAX_TOOLS_PER_MULTITOOL_REACHED_ERROR = new CmsError(CMS_ERROR_CODES.MAX_TOOLS_PER_MULTITOOL_REACHED, "error_max_tools_per_multitool_reached");
|
||||
internal static CmsError MAG_POS_OCCUPIED_ERROR = new CmsError(CMS_ERROR_CODES.MAG_POS_OCCUPIED, "error_mag_pos_occupied");
|
||||
|
||||
#endregion Cms Errors Codes
|
||||
|
||||
|
||||
Reference in New Issue
Block a user