da8ba63c63
- modifica peso errori lettura - gestione param opzionale x calcolo baseAddr
116 lines
2.6 KiB
C#
116 lines
2.6 KiB
C#
using S7.Net;
|
|
|
|
namespace IOB_WIN_NEXT
|
|
{
|
|
/// <summary>
|
|
/// Implementazione classe connessione ModBus TCP,
|
|
/// comprensiva dei parametri delle aree di memoria
|
|
/// </summary>
|
|
public class connParamModBusTCP
|
|
{
|
|
#region Public Fields
|
|
|
|
/// <summary>
|
|
/// Indirizzo di base degli Holding Register
|
|
/// </summary>
|
|
public int holdRegBaseAddr = 40001;
|
|
|
|
/// <summary>
|
|
/// Indica se usare baseAddress calcolati o da config
|
|
/// </summary>
|
|
public bool useCalcBaseAddr = true;
|
|
|
|
/// <summary>
|
|
/// Indirizzo IP del PLC
|
|
/// </summary>
|
|
public string ipAdrr = "";
|
|
|
|
/// <summary>
|
|
/// Base area x lettura
|
|
/// </summary>
|
|
public string memAddrRead = "";
|
|
|
|
/// <summary>
|
|
/// Base area x scrittura
|
|
/// </summary>
|
|
public string memAddrWrite = "";
|
|
|
|
/// <summary>
|
|
/// Size memoria lettura
|
|
/// </summary>
|
|
public int memSizeRead = 0;
|
|
|
|
/// <summary>
|
|
/// Size memoria scrittura
|
|
/// </summary>
|
|
public int memSizeWrite = 0;
|
|
|
|
/// <summary>
|
|
/// Timeout ping
|
|
/// </summary>
|
|
public int pingMsTimeout = 250;
|
|
|
|
/// <summary>
|
|
/// Porta di comunicazione
|
|
/// </summary>
|
|
public int port;
|
|
|
|
#endregion Public Fields
|
|
}
|
|
|
|
/// <summary>
|
|
/// Implementazione classe connessione SIEMENS con S7.net, comprensiva dei parametri delle aree
|
|
/// di memoria
|
|
/// </summary>
|
|
public class connParamS7
|
|
{
|
|
#region Public Fields
|
|
|
|
/// <summary>
|
|
/// Indirizzo IP del PLC
|
|
/// </summary>
|
|
public string ipAdrr = "";
|
|
|
|
/// <summary>
|
|
/// Base area x lettura
|
|
/// </summary>
|
|
public string memAddrRead = "";
|
|
|
|
/// <summary>
|
|
/// Base area x scrittura
|
|
/// </summary>
|
|
public string memAddrWrite = "";
|
|
|
|
/// <summary>
|
|
/// Size memoria lettura
|
|
/// </summary>
|
|
public int memSizeRead = 0;
|
|
|
|
/// <summary>
|
|
/// Size memoria scrittura
|
|
/// </summary>
|
|
public int memSizeWrite = 0;
|
|
|
|
/// <summary>
|
|
/// Timeout ping
|
|
/// </summary>
|
|
public int pingMsTimeout = 250;
|
|
|
|
/// <summary>
|
|
/// Rack comunicazione
|
|
/// </summary>
|
|
public short rack = 0;
|
|
|
|
/// <summary>
|
|
/// Slot comunicazione
|
|
/// </summary>
|
|
public short slot = 0;
|
|
|
|
/// <summary>
|
|
/// Tipo CPU Siemens
|
|
/// </summary>
|
|
public CpuType tipoCpu = CpuType.S7300;
|
|
|
|
#endregion Public Fields
|
|
}
|
|
} |