Merge branch 'release/IobWinFanuc_01'

This commit is contained in:
Samuele Locatelli
2025-01-15 16:10:13 +01:00
149 changed files with 8338 additions and 13056 deletions
+58
View File
@@ -208,6 +208,19 @@ IOB-WIN:build:
script:
- '& "$env:MSBUILD_PATH" "$env:APP_NAME\$env:APP_NAME.csproj" -target:Build /p:Configuration=Release /p:Platform="x86" /p:OutputPath=bin/ /nodeReuse:false /verbosity:minimal /m'
IOB-WIN-FANUC:build:
stage: build
tags:
- win
variables:
APP_NAME: IOB-WIN-FANUC
before_script:
- *nuget-fix
- '& "$env:NUGET_PATH" restore "$env:APP_NAME.sln" -verbosity quiet'
- *version-fix
script:
- '& "$env:MSBUILD_PATH" "$env:APP_NAME\$env:APP_NAME.csproj" -target:Build /p:Configuration=Release /p:Platform="x86" /p:OutputPath=bin/ /nodeReuse:false /verbosity:minimal /m'
IOB-WIN-MBUS:build:
stage: build
tags:
@@ -327,6 +340,31 @@ IOB-WIN:release:
- *nexusUpload
- *SendToVersionsLog
IOB-WIN-FANUC:release:
stage: release
needs: ["IOB-WIN-FANUC:build"]
tags:
- win
variables:
APP_NAME: IOB-WIN-FANUC
NEXUS_PATH: MAPO/IOB-WIN-FANUC
rules:
- if: $CI_COMMIT_BRANCH == 'master'
changes:
- IOB-WIN-FANUC/*
when: always
before_script:
- *nuget-fix
- '& "$env:NUGET_PATH" restore "$env:APP_NAME.sln" -verbosity quiet'
- *version-fix
- *cleanup-zip
script:
- '& "$env:MSBUILD_PATH" "$env:APP_NAME\$env:APP_NAME.csproj" -target:Build /p:Configuration=Release /p:Platform="x86" /p:OutputPath=bin/ /nodeReuse:false /verbosity:minimal /m'
- *zipper
- *hashBuild
- *nexusUpload
- *SendToVersionsLog
IOB-WIN-MBUS:release:
stage: release
needs: ["IOB-WIN-MBUS:build"]
@@ -526,6 +564,26 @@ IOB-WIN-MBUS:docfx:
- mv $env:APP_NAME/_site "docfx"
- *DocReplica
IOB-WIN-FANUC:docfx:
stage: docfx
needs: ["IOB-WIN-FANUC:build"]
tags:
- win
variables:
APP_NAME: IOB-WIN-FANUC
rules:
- if: $CI_COMMIT_BRANCH == 'master'
changes:
- IOB-WIN-FANUC/*
when: always
before_script:
- *nuget-fix
- '& "$env:NUGET_PATH" restore "$env:APP_NAME.sln" -verbosity quiet'
script:
- docfx $env:APP_NAME/docfx.json
- mv $env:APP_NAME/_site "docfx"
- *DocReplica
IOB-WIN-MTC:docfx:
stage: docfx
needs: ["IOB-WIN-MTC:build"]
+13 -13
View File
@@ -14,7 +14,7 @@ Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "IOB-UT-NEXT", "IOB-UT-NEXT\
EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "IOB-WIN-FORM", "IOB-WIN-FORM\IOB-WIN-FORM.csproj", "{9BA331BB-9BF1-40E0-AC03-74B43D73A097}"
EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "IOB-WIN-PING", "IOB-WIN-PING\IOB-WIN-PING.csproj", "{6ADF1E82-124C-489C-99EF-A857C933D362}"
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "IOB-WIN-FANUC", "IOB-WIN-FANUC\IOB-WIN-FANUC.csproj", "{4F59C1D0-6CAE-4B30-AA21-71126472187C}"
EndProject
Global
GlobalSection(SolutionConfigurationPlatforms) = preSolution
@@ -61,18 +61,18 @@ Global
{9BA331BB-9BF1-40E0-AC03-74B43D73A097}.Remote_DEBUG|Any CPU.Build.0 = Debug|Any CPU
{9BA331BB-9BF1-40E0-AC03-74B43D73A097}.Remote_DEBUG|x86.ActiveCfg = Release|Any CPU
{9BA331BB-9BF1-40E0-AC03-74B43D73A097}.Remote_DEBUG|x86.Build.0 = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Debug|Any CPU.Build.0 = Debug|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Debug|x86.ActiveCfg = Debug|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Debug|x86.Build.0 = Debug|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Release|Any CPU.ActiveCfg = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Release|Any CPU.Build.0 = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Release|x86.ActiveCfg = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Release|x86.Build.0 = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Remote_DEBUG|Any CPU.ActiveCfg = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Remote_DEBUG|Any CPU.Build.0 = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Remote_DEBUG|x86.ActiveCfg = Release|Any CPU
{6ADF1E82-124C-489C-99EF-A857C933D362}.Remote_DEBUG|x86.Build.0 = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Debug|Any CPU.Build.0 = Debug|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Debug|x86.ActiveCfg = Debug|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Debug|x86.Build.0 = Debug|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Release|Any CPU.ActiveCfg = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Release|Any CPU.Build.0 = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Release|x86.ActiveCfg = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Release|x86.Build.0 = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Remote_DEBUG|Any CPU.ActiveCfg = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Remote_DEBUG|Any CPU.Build.0 = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Remote_DEBUG|x86.ActiveCfg = Release|Any CPU
{4F59C1D0-6CAE-4B30-AA21-71126472187C}.Remote_DEBUG|x86.Build.0 = Release|Any CPU
EndGlobalSection
GlobalSection(SolutionProperties) = preSolution
HideSolutionNode = FALSE
+56
View File
@@ -0,0 +1,56 @@
using IOB_UT_NEXT;
using IOB_WIN_FANUC.Iob;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace IOB_WIN_FANUC
{
public class AdapterFormNext: IOB_WIN_FORM.AdapterForm
{
/// <summary>
/// Avvio MainForm
/// </summary>
/// <param name="codIOB"></param>
public AdapterFormNext(string codIOB): base(codIOB)
{
}
/// <summary>
/// carica IOB richiesto
/// </summary>
protected override void loadIobType()
{
if (IOBConf != null)
{
switch (tipoScelto)
{
case tipoAdapter.FANUC:
iobObj = new Iob.Fanuc(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIMULA:
case tipoAdapter.ND:
default:
iobObj = new IOB_WIN_FORM.Iob.Simula(this, IOBConf);
btnStart.Enabled = false;
break;
}
lblCncText = $"CNC: {IOBConf.tipoIob} [{IOBConf.cncIpAddr}:{IOBConf.cncPort}]";
lblSrvUrlText = $"SRV: {IOBConf.serverData.MPIP} | URL: {IOBConf.serverData.MPURL}{IOBConf.serverData.CMDBASE}";
// aggancio evento refresh
iobObj.eh_refreshed += IobObj_eh_refreshed;
// carico i default values su interfaccia
setDefaults();
displayTaskAndLog($"Caricata conf per adapter {tipoScelto}");
}
}
}
}
+10
View File
@@ -0,0 +1,10 @@
<?xml version="1.0" encoding="utf-8" ?>
<!-- For more information on using transformations
see the web.config examples at http://go.microsoft.com/fwlink/?LinkId=214134. -->
<configuration xmlns:xdt="http://schemas.microsoft.com/XML-Document-Transform">
<appSettings>
<add key="autoLoadConf" value="true" xdt:Transform="Replace" xdt:Locator="Match(key)"/>
<!--<add key="DemoIn" value="true" xdt:Transform="Replace" xdt:Locator="Match(key)"/>-->
<!--<add key="DemoOut" value="true" xdt:Transform="Replace" xdt:Locator="Match(key)"/>-->
</appSettings>
</configuration>
+11
View File
@@ -0,0 +1,11 @@
<?xml version="1.0" encoding="utf-8" ?>
<!-- For more information on using transformations
see the web.config examples at http://go.microsoft.com/fwlink/?LinkId=214134. -->
<configuration xmlns:xdt="http://schemas.microsoft.com/XML-Document-Transform">
<appSettings>
<add key="autoLoadConf" value="true" xdt:Transform="Replace" xdt:Locator="Match(key)"/>
<add key="DemoIn" value="false" xdt:Transform="Replace" xdt:Locator="Match(key)"/>
<add key="DemoOut" value="false" xdt:Transform="Replace" xdt:Locator="Match(key)"/>
<add key="verbose" value="false" xdt:Transform="Replace" xdt:Locator="Match(key)"/>
</appSettings>
</configuration>
+182
View File
@@ -0,0 +1,182 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<configSections>
<section name="entityFramework" type="System.Data.Entity.Internal.ConfigFile.EntityFrameworkSection, EntityFramework, Version=6.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" requirePermission="false" />
</configSections>
<startup>
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.6.2" />
</startup>
<appSettings>
<add key="appName" value="IOB-WIN-FANUC" />
<add key="enableTest" value="false" />
<add key="enableContapezzi" value="true" />
<add key="enableMode" value="true" />
<add key="enableOverrides" value="false" />
<add key="enableTSVC" value="true" />
<add key="enableDynData" value="false" />
<add key="enableSysInfo" value="false" />
<add key="enableAlarms" value="true" />
<add key="doStartMemDump" value="false" />
<add key="doSampleMemory" value="false" />
<add key="basePrgMemPath" value="CNCMEMUSER" />
<add key="pingMsTimeout" value="1500" />
<add key="serverPingDisabled" value="false" />
<add key="urlCallTOut" value="9999" />
<add key="urlRandWait" value="200" />
<!-- ciclo corto x invio a server: ms -->
<add key="timerIntMs" value="10" />
<add key="fastCount" value="20" />
<add key="normCount" value="200" />
<add key="slowCount" value="500" />
<add key="verySlowCount" value="3000" />
<add key="sampleMemCount" value="6000" />
<add key="waitEndCycle" value="0" />
<add key="comCheckTOut" value="10" />
<!-- watchdog, ping, check disconnesso -->
<add key="nMaxSend" value="10" />
<add key="pingTestSec" value="5" />
<add key="watchdogMaxSec" value="90" />
<add key="disconMaxSec" value="30" />
<add key="defIOB" value="2999" />
<add key="pauseSendMSec" value="2000" />
<add key="sendStartFLog" value="false" />
<!--gestione coda-->
<add key="maxQueueFLog" value="16384" />
<add key="maxQueueRawTransf" value="1024" />
<!--gestione max num errori-->
<add key="maxAliveErrors" value="1000" />
<add key="maxErroriCheck" value="300" />
<add key="maxSendErrors" value="100" />
<add key="maxReadErrors" value="20" />
<!--parametri SIM-->
<add key="waitSimPar" value="30" />
<!--<add key="waitSimPar" value="45" />-->
<!--gestione REDIS-->
<add key="RedisConn" value="localhost,abortConnect=false,ssl=false" />
<add key="RedisConnAdmin" value="localhost,abortConnect=false,ssl=false" />
<add key="redisDb" value="10" />
<!--gestione invio dati in blocchi Json-->
<add key="minJsonData" value="2" />
<add key="maxJsonData" value="100" />
<add key="maxJsonDataEv" value="25" />
<!--gestione multithread-->
<add key="sendDataByThread" value="false" />
<!--Modalità DEMO: DemoOUT indica che NON invia davvero al server e DemoIN che simula e NON legge da PLC-->
<add key="DemoIn" value="false" />
<add key="DemoInSample" value="false" />
<add key="DemoOut" value="false" />
<!--definizione invio dati molto variabili-->
<add key="SendAxPos" value="false" />
<add key="SendFeedSpeed" value="false" />
<!--Definizione avvio Adapter-->
<add key="autoLoadConf" value="true" />
<add key="autoStartOnLoad" value="true" />
<add key="startMinimized" value="false" />
<add key="windowCanMax" value="true" />
<add key="trayClose" value="true" />
<add key="autoSaveSec" value="60" />
<add key="waitRecMSec" value="60000" />
<add key="testCharSep" value="|" />
<add key="delayShowLogMs" value="500" />
<add key="vetoSeconds" value="5" />
<!--conf file-->
<add key="dataPath" value="DATA" />
<add key="dataConfPath" value="DATA\CONF" />
<add key="dataDatPath" value="DATA\DAT" />
<add key="resxPath" value="Resources" />
<add key="mainConfFile" value="MAIN.ini" />
<add key="defaultPersLayerFile" value="PersistData.dat" />
<!--<add key="simDataFile" value="SimData.dat" />-->
<!--<add key="memDumpFile" value="MemoryDump.dat" />-->
<add key="numSim" value="1" />
<add key="AUpdAsAdm" value="true" />
<add key="ConfToCloud" value="false" />
<add key="CacheConfToCloudDuratHour" value="24" />
<!--logging-->
<add key="recTime" value="true" />
<add key="verbose" value="false" />
<add key="logEvery" value="100" />
<add key="zipLogOldDay" value="1" />
<add key="maxLogDirSize" value="300" />
<add key="maxLogDays" value="400" />
<add key="numRowConsole" value="50" />
<add key="verboseLogTOut" value="60" />
<!--conf x FANUC-->
<add key="ClientSettingsProvider.ServiceUri" value="" />
<add key="pzCountDelay" value="2000" />
</appSettings>
<runtime>
<assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">
<probing privatePath="lib;libs" xmlns="urn:schemas-microsoft-com:asm.v1" />
<dependentAssembly>
<assemblyIdentity name="System.IO.Compression" publicKeyToken="b77a5c561934e089" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.2.0.0" newVersion="4.2.0.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Threading.Tasks.Extensions" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.2.1.0" newVersion="4.2.1.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Buffers" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.0.4.0" newVersion="4.0.4.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="Microsoft.Bcl.AsyncInterfaces" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-9.0.0.0" newVersion="9.0.0.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Text.Json" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-9.0.0.0" newVersion="9.0.0.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Runtime.CompilerServices.Unsafe" publicKeyToken="b03f5f7f11d50a3a" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-6.0.1.0" newVersion="6.0.1.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Memory" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.0.2.0" newVersion="4.0.2.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.IO.Pipelines" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-9.0.0.0" newVersion="9.0.0.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="Microsoft.Web.WebView2.WinForms" publicKeyToken="2a8ab48044d2601e" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-1.0.2903.40" newVersion="1.0.2903.40" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="Microsoft.Web.WebView2.Core" publicKeyToken="2a8ab48044d2601e" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-1.0.2903.40" newVersion="1.0.2903.40" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.ValueTuple" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.0.3.0" newVersion="4.0.3.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Numerics.Vectors" publicKeyToken="b03f5f7f11d50a3a" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.1.5.0" newVersion="4.1.5.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Threading.Channels" publicKeyToken="cc7b13ffcd2ddd51" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-9.0.0.0" newVersion="9.0.0.0" />
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="Microsoft.Extensions.Logging.Abstractions" publicKeyToken="adb9793829ddae60" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-9.0.0.0" newVersion="9.0.0.0" />
</dependentAssembly>
</assemblyBinding>
</runtime>
<system.web>
<membership defaultProvider="ClientAuthenticationMembershipProvider">
<providers>
<add name="ClientAuthenticationMembershipProvider" type="System.Web.ClientServices.Providers.ClientFormsAuthenticationMembershipProvider, System.Web.Extensions, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35" serviceUri="" />
</providers>
</membership>
<roleManager defaultProvider="ClientRoleProvider" enabled="true">
<providers>
<add name="ClientRoleProvider" type="System.Web.ClientServices.Providers.ClientRoleProvider, System.Web.Extensions, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35" serviceUri="" cacheTimeout="86400" />
</providers>
</roleManager>
</system.web>
</configuration>
+74
View File
@@ -0,0 +1,74 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=TORNOS
MODEL=DT26
[CNC]
; TORNOS DT26 I
IP=192.168.1.80
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=8
AREAY_SIZE=16
; Red: Y8.4 | Yellow: Y8.5 | Green Y8.6 | All DoorsClosed: Y4.0 (X5.1) | ..........WrkZone Y8.7 | Contapezzi X7.1
;BIT0=CONN
BIT1=Y8.6
BIT2=PZCOUNT.D.6416.DW
;BIT2=X7.1
BIT3=Y8.4
BIT4=Y8.5
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
;PZCOUNT_MODE=BIT.X7.1
PZCOUNT_MODE=STD.D.6416.DW
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
+74
View File
@@ -0,0 +1,74 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=TORNOS
MODEL=DT26
[CNC]
; TORNOS DT26 II IOT ENABLED
IP=172.16.199.10
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=8
AREAY_SIZE=16
; Red: Y8.4 | Yellow: Y8.5 | Green Y8.6 | All DoorsClosed: Y4.0 (X5.1) | ..........WrkZone Y8.7 | Contapezzi X7.1
;BIT0=CONN
BIT1=Y8.6
BIT2=PZCOUNT.D.6416.DW
;BIT2=X7.1
BIT3=Y8.4
BIT4=Y8.5
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=24
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
;PZCOUNT_MODE=BIT.X7.1
PZCOUNT_MODE=STD.D.6416.DW
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
+76
View File
@@ -0,0 +1,76 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=CMZ
MODEL=TA20
[CNC]
; CMZ TA20
IP=192.168.1.57
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=0
AREAY_SIZE=8
; Red: Y3.7 | Yellow: Y3.6 | Green Y3.5 | All DoorsClosed: Y4.0 (X5.1) | ..........WrkZone Y8.7
;BIT0=CONN
BIT1=Y3.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.7
BIT4=Y3.6
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=BIGLIA
MODEL=446
[CNC]
; BIGLIA 446
IP=192.168.0.20
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=0
AREAY_SIZE=12
; Red: Y3.2 | Yellow: !Y8.0 | Green Y4.5
;BIT0=CONN
BIT1=Y4.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y8.0
BIT5=Y2.0
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 1
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=8
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=BIGLIA
MODEL=445
[CNC]
; BIGLIA 445
IP=192.168.0.19
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=0
AREAY_SIZE=12
; Red: Y3.2 | Yellow: !Y8.0 | Green Y4.5
;BIT0=CONN
BIT1=Y4.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y8.0
BIT5=Y2.0
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 1
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=8
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
+72
View File
@@ -0,0 +1,72 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=HANWHA
MODEL=XD26J
[CNC]
; HANWHA XD26J
IP=192.168.0.22
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=0
AREAY_SIZE=56
; Red: Y53.0 | Yellow: Y53.1 | Green Y53.2
;BIT0=CONN
BIT1=Y53.2
BIT2=PZCOUNT.PAR.6711
BIT3=Y53.0
BIT4=Y53.1
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 1
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=8
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
PZ_CAD_MADDR=1602
PZ_REQ_MADDR=1603
PZ_DONE_MADDR=1604
PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
+72
View File
@@ -0,0 +1,72 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=STAR
MODEL=SR32J
[CNC]
; STAR SR32J
IP=192.168.0.21
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=0
AREAY_SIZE=8
; Red: Y0.2 | Yellow: Y1.2 | Green Y2.6 | PZCount R10.5 / R22.4
;BIT0=CONN
BIT1=Y2.6
BIT2=PZCOUNT.PAR.6711
BIT3=Y0.2
BIT4=Y1.2
AREAD_START=0
AREAD_SIZE=0
AREAR_START=0
AREAR_SIZE=0
AREAX_START=0
AREAX_SIZE=0
AREAY_START=0
AREAY_SIZE=0
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 1
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=8
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
PZ_CAD_MADDR=1602
PZ_REQ_MADDR=1603
PZ_DONE_MADDR=1604
PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
+76
View File
@@ -0,0 +1,76 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=TAKAHASHI
MODEL=TNC-L10
[CNC]
; TAKAHASHI TNC-L10-NCL
IP=192.168.0.23
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=0
AREAY_SIZE=24
; Red: Y21.4 | Yellow: Y21.5 | Green Y21.6
;BIT0=CONN
BIT1=Y21.6
BIT2=PZCOUNT.PAR.6711
BIT3=Y21.4
BIT4=Y21.5
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 1
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=8
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
+86
View File
@@ -0,0 +1,86 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=DMG MORI Gildemeister
MODEL=SPRINT-32-5
[CNC]
; DMG MORI (IOT ENABLED)
IP=192.168.0.12
PORT=19000
;PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
;schema elettrico (203 pg):
;1) le lampade e i colori (pag 7 di 203, Y1.0 --> Y1.3)
;2) modo auto (6 di 203, X7.2)
;3) porte (19 di 203, X8.6)
;4) allarme (61 di 203, X10.5) e guasto (61 di 203, X10.3 / X10.4)
;
;lista segnali (12 pg)
;5a) emergenza ch1 (spero vada bene) --> pag 3 di 12, X8.4
;5b) emergenza ch1 --> pg 8 di 12, Y7.0
;6) prog in RUN Y5.0 (pag 6 di 12)
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=8
AREAY_SIZE=16
; Red: Y1.1 | Yellow: Y1.2 | Green Y1.3 | All DoorsClosed: Y4.0 (X5.1) | ..........WrkZone Y8.7 | PZ richiesti: D.7960.DW - PZ prodotti: D.7964.DW
;BIT0=CONN
BIT1=Y1.3
BIT2=PZCOUNT.D.7964.DW
BIT3=Y1.1
BIT4=Y1.2
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1990 --> 7960, 1991 --> 7964)
PZCOUNT_MODE=STD.D.7964.DW
;PZ_CAD_MADDR=???; cad
;PZ_REQ_MADDR=1990; pz richiesti (DW)
;PZ_DONE_MADDR=1991; pz fatti (DW)
;PZ_GTOT_MADDR=???; pz tot macchina
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
+73
View File
@@ -0,0 +1,73 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=CITIZEN
MODEL=GN-3200
[CNC]
; CITIZEN RETTIFICA 3021
IP=192.168.0.24
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y2.0 | Yellow: Y1.7 | Green Y2.1 | riscaldamento Y7.4 | D19.1 MANCA PEZZO (SE rosso)
;BIT0=CONN
BIT1=Y2.1
BIT2=PZCOUNT.PAR.6711
BIT3=Y2.0
BIT4=Y1.7
BIT5=Y7.4
AREAD_START=0
AREAD_SIZE=0
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=0
AREAX_START=0
AREAX_SIZE=0
AREAY_START=0
AREAY_SIZE=8
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 0
;bit3 = 0
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=16
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
PZGTOT_MODE=STD.PAR.6712
PZREQ_MODE=STD.PAR.6713
;PZCAD_MODE=STD.D.6408.DW
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
+86
View File
@@ -0,0 +1,86 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=STAR
MODEL=SV-20R
[CNC]
; START Tornio a Fantina SV20R
IP=192.168.0.70
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y31.4 | Yellow: Y31.5 | Green Y31.6 | riscaldamento Y7.4 ???
;BIT0=CONN
BIT1=Y31.6
;BIT2=PZCOUNT.PAR.6711
BIT2=PZCOUNT.MACRO.10100
;BIT2=STD.MACRO.10100
BIT3=Y31.4
BIT4=Y31.5
; 8.4 --> emg armata= true, 0 = attiva mettere !8.4 (da verificare)
BIT5=!X8.4
;BIT6=X8.4
AREAD_START=0
AREAD_SIZE=0
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=0
AREAX_START=0
AREAX_SIZE=40
AREAY_START=0
AREAY_SIZE=32
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 60
;bit0 = 0
;bit1 = 1
;bit2 = 0
;bit3 = 0
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=2
;BLINK_FILT=16
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
;PZCOUNT_MODE=STD.PAR.6711
PZCOUNT_MODE=STD.MACRO.10100
PZREQ_MODE=STD.MACRO.10000
PZGTOT_MODE=STD.PAR.6712
;PZCAD_MODE=STD.D.6408.DW
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
DISABLE_SEND_WDST=TRUE
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=JETCO
HostOS=WIN
HostName=IOB-WIN-09
HostAddr=192.168.1.133
+97
View File
@@ -0,0 +1,97 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=GHIRINGHELLI
MODEL=GMG-M200
[CNC]
; START Tornio a Fantina SV20R
IP=192.168.0.91
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
; giallo --> 15000.0
; richiesta interv operatore --> R15000.1 --> mandare in BLU!!! è richiesta intervento operatore...
; RO tot pezzi vita macchina D128 (DW, 4 byte)
; RO contapezzi D132 (DW, 4 byte)
; RW richiesta pezzi D136 (DW, 4 byte) --> occhio scrittura con bitconverter
[MEMORY]
; Red: Y91.3 | Yellow: R15000.0 | Green Y91.4 | emerg 8.4
;BIT0=CONN
BIT1=Y91.4
BIT2=PZCOUNT.D.132
;BIT2=STD.MACRO.10100
BIT3=Y91.3
; poichè leggo da 15000 --> R0.0 --> R15000.0
;BIT4=R0.0
; 8.4 --> emg armata= true, 0 = attiva mettere !8.4 (da verificare)
BIT5=!X8.4
;BIT6=X33.4
AREAD_START=128
AREAD_SIZE=12
AREAG_SIZE=48
;AREAG_SIZE=48
AREAR_START=15000
AREAR_SIZE=4
AREAX_START=0
AREAX_SIZE=40
AREAY_START=0
AREAY_SIZE=92
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 60
;bit0 = 0
;bit1 = 1
;bit2 = 0
;bit3 = 0
;bit4 = 0
;bit5 = 0
;bit6 = 0
;bit7 = 0
; da gestire rosso lampeggiante?
BLINK_FILT=2
;BLINK_FILT=16
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.D.132.DW
PZREQ_MODE=STD.D.136.DW
PZGTOT_MODE=STD.D.128.DW
;PZCAD_MODE=STD.D.6408.DW
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
ENABLE_PZ_REQ=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
DISABLE_SEND_WDST=TRUE
; bit da scrivere come trace ad ogni check
;MEM_2_TRACE=|BIT3|BIT4|BIT5|
PARAM_CONF=3028.json
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=JETCO
HostOS=WIN
HostName=IOB-WIN-09
HostAddr=192.168.1.133
+30
View File
@@ -0,0 +1,30 @@
{
"mMapWrite": {
//"setComm": {
// "name": "setComm",
// "description": "Commessa",
// "tipoMem": "String",
// "memAddr": "VarADS.NomeLancioRichiesto",
// "index": 0,
// "size": 0
//},
//"setArt": {
// "name": "setArt",
// "description": "Articolo",
// "tipoMem": "String",
// "memAddr": "VarADS.NomeDisegnoRichiesto",
// "index": 0,
// "size": 0
//},
"setPzComm": {
"name": "setPzComm",
"description": "Qty",
"memAddr": "STD.D.136.DW",
"tipoMem": "DInt",
"index": 0,
"size": 0
}
},
"mMapRead": {
}
}
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=SHE HONG
MODEL=VMC-S/A
[CNC]
; SHE HONG
IP=192.168.50.55
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=12
; Red: Y11.0 | Yellow: Y0.3 | Green Y0.4 | All DoorsClosed: Y4.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y0.4
BIT2=PZCOUNT.PAR.6711
BIT3=Y11.0
BIT4=Y0.3
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 1
;bit2 = 0
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=DOOSAN
MODEL=PUMA500
[CNC]
; DOOSAN PUMA500 overmach
IP=192.168.50.50
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=8
; Red: Y3.2 | Yellow: Y3.1 | Green Y3.0 | All DoorsClosed: X8.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=DOOSAN
MODEL=PUMA700 1116
[CNC]
; DOOSAN PUMA700 1116 overmach
IP=192.168.50.51
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=8
; Red: Y3.2 | Yellow: Y3.1 | Green Y3.0 | All DoorsClosed: X8.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=DOOSAN
MODEL=PUMA500
[CNC]
; DOOSAN PUMA500 overmach
IP=192.168.50.53
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=8
; Red: Y0.7 | Yellow: Y0.6 | Green Y0.5 | All DoorsClosed: X8.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y0.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y0.7
BIT4=Y0.6
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=HWACHEON
MODEL=HI-TECH300-400
[CNC]
; HWACHEON
IP=192.168.50.54
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=12
; Red: Y10.4 | Yellow: Y10.6 | Green !Y10.5 | All DoorsClosed: Y11.3 | Emergenza X8.4
;BIT0=CONN
BIT1=!Y10.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y10.4
BIT4=Y10.6
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 1
;bit2 = 0
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=KDM
MODEL=KTM 12/16
[CNC]
; KDM Ktm 12/16
IP=192.168.50.53
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=8
; Red: Y3.2 | Yellow: Y3.1 | Green Y3.0 | All DoorsClosed: X8.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+85
View File
@@ -0,0 +1,85 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=PUMA
MODEL=PUMA 4100
[CNC]
IP=192.168.170.49
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=8
; Red: Y3.2 | Yellow: Y3.1 | Green Y3.0 | All DoorsClosed: X8.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 1
;bit2 = 0
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; Disabilito conteggio Pezzi come richiesto
DISABLE_PZCOUNT=TRUE
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=Fluitek
HostOS=WIN
HostName=FLUITEK-IOB-01
HostAddr=192.168.169.53
+84
View File
@@ -0,0 +1,84 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=AWEA
MODEL=BM1600
[CNC]
IP=192.168.170.50
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.168.17
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=12
AREAY_SIZE=8
; Red: Y4.0 | Yellow: Y4.1 | Green Y3.7 | All DoorsClosed: X8.1 | Emergenza X8.4
;BIT0=CONN
BIT1=Y3.7
BIT2=PZCOUNT.PAR.6711
BIT3=Y4.0
BIT4=Y4.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 1
;bit2 = 0
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; Disabilito conteggio Pezzi come richiesto
DISABLE_PZCOUNT=TRUE
[BRANCH]
NAME=master
[TAGS]
Customer=Fluitek
HostOS=WIN
HostName=FLUITEK-IOB-02
HostAddr=192.168.169.82
@@ -1,20 +1,19 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE, isola Trevisan 424 con robot Kawasaki (NO industria 4.0)
CNCTYPE=SIEMENS_FAPE
[IOB]
;Tornio FANUC ROBOTDRILL
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape
VENDOR=TREVISAN
MODEL=GT529
[CNC]
IP=192.168.1.57
CPUTYPE=S71200
RACK=0
SLOT=0
IP=192.168.0.85
PORT=8193
GETPRGNAME=true
[SERVER]
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
@@ -25,16 +24,27 @@ CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
; Red: Y0.2 | Yellow: Y0.3 | Green Y0.0 | Apertura Auto porta: Y0.4 (X5.1) | NON Emergenza Y0.5 | MODO AUTO Y0.6 | Contapezzi Y0.1
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
BIT1=Y0.0
BIT2=Y0.1
;BIT2=PZCOUNT.PAR.6711
BIT3=Y0.2
BIT4=Y0.3
BIT5=Y0.5
;BIT6=Y0.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=4
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
@@ -53,11 +63,12 @@ BLINK_FILT=0
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
PZCOUNT_MODE=BIT
;PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
@@ -1,20 +1,19 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE, isola Trevisan 547
CNCTYPE=SIEMENS_FAPE
[IOB]
;Tornio TREVISAN 555
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape
VENDOR=TREVISAN
MODEL=GT555
[CNC]
IP=192.168.1.55
CPUTYPE=S71200
RACK=0
SLOT=0
IP=192.168.0.54
PORT=8193
GETPRGNAME=true
[SERVER]
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
@@ -25,16 +24,24 @@ CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
; Red: Y95.7 | Yellow: Y96.7 | Green Y96.3 | All DoorsClosed: Y4.0 (X5.1) | ..........WrkZone Y8.7 | Contapezzi X7.1
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
BIT1=Y96.3
BIT2=PZCOUNT.PAR.6711
BIT3=Y95.7
BIT4=Y96.7
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=128
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
@@ -53,11 +60,11 @@ BLINK_FILT=0
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
@@ -1,20 +1,19 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE, isola BTB1
CNCTYPE=SIEMENS_FAPE
[IOB]
;Tornio FANUC Doosan Overmach
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape
VENDOR=Doosan Overmach
MODEL=GT575
[CNC]
IP=192.168.1.56
CPUTYPE=S71200
RACK=0
SLOT=0
IP=192.168.1.46
PORT=8193
GETPRGNAME=true
[SERVER]
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
@@ -25,16 +24,25 @@ CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
; Red: Y3.2 | Yellow:Y3.1 | Green Y3.0 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO Y1.2 (X12.4) | Contapezzi Y0.1
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
@@ -53,11 +61,12 @@ BLINK_FILT=0
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
+83
View File
@@ -0,0 +1,83 @@
;Configurazione IOB-WIN
[IOB]
;Tornio CMF 645
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=CMF
MODEL=T91
[CNC]
IP=192.168.0.133
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y1.3 | Yellow:Y0.6 | Green Y0.5 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO Y1.2 (X12.4) | Contapezzi Y0.1
;BIT0=CONN
BIT1=Y0.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y1.3
BIT4=Y0.6
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=0
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
; Tags manuali
[TAGS]
Customer=LVF
HostOS=WIN
HostName=Server-MAPO-IOB
HostAddr=192.168.1.208
+84
View File
@@ -0,0 +1,84 @@
;Configurazione IOB-WIN
[IOB]
;Tornio CMF 646
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=CMF
MODEL=T91
[CNC]
IP=192.168.0.145
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y1.3 | Yellow:Y0.6 | Green Y0.5 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO Y1.2 (X12.4) | Contapezzi Y0.1
;BIT0=CONN
BIT1=Y0.5
BIT2=PZCOUNT.PAR.6711
BIT3=Y1.3
BIT4=Y0.6
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=26
;BLINK_FILT=0
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
; Tags manuali
[TAGS]
Customer=LVF
HostOS=WIN
HostName=Server-MAPO-IOB
HostAddr=192.168.1.208
+83
View File
@@ -0,0 +1,83 @@
;Configurazione IOB-WIN
[IOB]
;Tornio FANUC Doosan Overmach PUMA 700
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Doosan Overmach
MODEL=GT613
[CNC]
IP=192.168.0.80
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y3.2 | Yellow:Y3.1 | Green Y3.0 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO DOOR X12.4 | Contapezzi Y0.1
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=develop
; Tags manuali
[TAGS]
Customer=LVF
HostOS=WIN
HostName=Server-MAPO-IOB
HostAddr=192.168.1.208
+83
View File
@@ -0,0 +1,83 @@
;Configurazione IOB-WIN
[IOB]
;Tornio FANUC Doosan Overmach PUMA GT3100
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Doosan Overmach
MODEL=GT653
[CNC]
IP=192.168.0.33
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y3.2 | Yellow:Y3.1 | Green Y3.0 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO DOOR X12.4 | Contapezzi Y0.1
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=LVF
HostOS=WIN
HostName=Server-MAPO-IOB
HostAddr=192.168.1.208
+83
View File
@@ -0,0 +1,83 @@
;Configurazione IOB-WIN
[IOB]
;Tornio FANUC Doosan Overmach PUMA 4100A
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Doosan Overmach
MODEL=GT658
[CNC]
IP=192.168.0.35
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y3.2 | Yellow:Y3.1 | Green Y3.0 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO DOOR X12.4 | Contapezzi Y0.1
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=LVF
HostOS=WIN
HostName=Server-MAPO-IOB
HostAddr=192.168.1.208
+83
View File
@@ -0,0 +1,83 @@
;Configurazione IOB-WIN
[IOB]
;Tornio FANUC Doosan Overmach PUMA GT3100
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Doosan Overmach
MODEL=GT673
[CNC]
IP=192.168.0.40
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y3.2 | Yellow:Y3.1 | Green Y3.0 | Apertura Auto porta: X8.0 (X8.1) | Emergenza X8.4 | MODO AUTO DOOR X12.4 | Contapezzi Y0.1
;BIT0=CONN
BIT1=Y3.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y3.2
BIT4=Y3.1
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_START=0
AREAG_SIZE=0
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=16
AREAY_START=0
AREAY_SIZE=16
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=5
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=LVF
HostOS=WIN
HostName=Server-MAPO-IOB
HostAddr=192.168.1.208
+50
View File
@@ -0,0 +1,50 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
;IDXMACC=3001
[CNC]
; TEST TORNOS!
;IP=192.168.1.80
IP=172.16.199.10
PORT=8193
[SERVER]
MPIP=http://10.74.82.219
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
BITRED=Y8.4
BITYELLOW=Y8.5
BITGREEN=Y8.6
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=BIT
PZ_CAD_MADDR=1602
PZ_REQ_MADDR=1603
PZ_DONE_MADDR=1604
PZ_GTOT_MADDR=1605
[BRANCH]
NAME=master
+74
View File
@@ -0,0 +1,74 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=COLCOM
MODEL=TAKISAWA
[CNC]
; TEST FANUC!
IP=192.168.0.228
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=192.168.111.104
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y7.4 | Yellow: Y51.1 (porta chiusa, da NEGARE) | Green Y7.6 | Alarm Y 51.4
;BIT0=CONN
BIT1=Y7.6
BIT2=PZCOUNT.D.3010.DW
BIT3=Y7.4
;BIT4=Y51.1
BIT5=Y51.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.D.3010.DW
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
;D.3010.DW: pz prodotti
;D.3020.DW: TOTALI
;D.3060.DW: pz da fare
;D.3064.DW: SUPER-TOTALE???
[BRANCH]
NAME=master
+69
View File
@@ -0,0 +1,69 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=COLCOM
MODEL=TSUGAMI
[CNC]
; TEST FANUC!
IP=192.168.0.245
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=192.168.111.104
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y4.7 | Yellow: Y5.1 | Green Y5.0 | ALARM Y 0.4 | Cycle CONT Y 4.4
;BIT0=CONN
BIT1=Y5.0
BIT2=PZCOUNT.PAR.6711
BIT3=Y4.7
BIT4=Y5.1
BIT5=Y0.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
;PZ_CAD_MADDR=1602; cad
;PZ_REQ_MADDR=1603; pz richiesti (DW)
;PZ_DONE_MADDR=1604; pz fatti
;PZ_GTOT_MADDR=1605; pz tot macchina
[BRANCH]
NAME=master
+75
View File
@@ -0,0 +1,75 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=COLCOM
MODEL=DMG-MORI
[CNC]
; TEST FANUC!
IP=192.168.100.78
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=192.168.111.104
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y12.4 | Yellow: Y51.1 (porta chiusa, da NEGARE) | Green Y12.6 | Alarm Y 51.4 | Blu Y12.7
;BIT0=CONN
BIT1=Y12.6
BIT2=PZCOUNT.PAR.6711
BIT3=Y12.4
BIT4=Y12.7
;BIT5=Y11.2
BIT5=X18.3
BIT6=X11.3
AREAD_START=0
AREAD_SIZE=9999
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
PZGTOT_MODE=STD.PAR.6712
;PZREQ_MODE=STD.PAR.6713
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
VENDOR=COLCOM
MODEL=DMG-MORI-02
[CNC]
; TEST FANUC!
;IP=192.168.100.81
;Nuovo ip in sottorete .80.
IP=192.168.80.34
PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=192.168.111.104
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Red: Y12.4 | Yellow: Y51.1 (porta chiusa, da NEGARE) | Green Y12.6 | Alarm Y 51.4 | Blu Y12.7
;BIT0=CONN
BIT1=Y12.6
;BIT2=PZCOUNT.PAR.6711
BIT3=Y12.4
BIT4=Y12.7
;BIT5=Y11.2
BIT5=X18.3
BIT6=X11.3
AREAD_START=0
AREAD_SIZE=9999
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
;PZCOUNT_MODE=STD.PAR.6711
;PZGTOT_MODE=STD.PAR.6712
;PZREQ_MODE=STD.PAR.6713
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=10
MAX_SEND_PZC_BLOCK=100
DISABLE_SEND_WDST=TRUE
[BRANCH]
NAME=master
+61
View File
@@ -0,0 +1,61 @@
;Configurazione IOB-WIN GENERALE
[BRANCH]
NAME=master
[SERVER]
; Server Steamware
MPIP=10.74.82.218
MPURL=/MP/IO
CMDREBO=/IOB/sendRebootGateway?GWIP=
CMDIOB2CALL=/IOB/getIob2call?GWIP=
;Client Install
CLI_INST=SteamWareSim
[IOB]
;--- TEST sul campo
; SIMULAZIONE verso server ufficio
;STARTLIST=SIMUL_01,SIMUL_02,SIMUL_03,SIMUL_04
;STARTLIST=PIZ09
;STARTLIST=VL25
;STARTLIST=SIMUL_03
;STARTLIST=GIACO_CEDAX_001
;STARTLIST=GIACO_ICOEL_002
;STARTLIST=GIACO_CENTERFRIGO
;STARTLIST=GIACO_NWSE
;STARTLIST=SIM_DP_01
;STARTLIST=WPS
;STARTLIST=FINASSI_HELPI_01
;STARTLIST=FINASSI_OMP_01
;STARTLIST=BAGLIETTO_CIMOLAI_01
;STARTLIST=GIACO_SAIM_003
;STARTLIST=PIZ09
;STARTLIST=IMI_RIMOR_SAB_01
;STARTLIST=IMI_RIMOR_SAB_02
;STARTLIST=IMI_RIMOR_VER_01
;STARTLIST=IMI_RIMOR_VER_02
;STARTLIST=IMI_PAMA_392
;STARTLIST=Tend_FIMAT_01
;STARTLIST=PIZ10
;STARTLIST=IMI_SOITAAB_Z2342_02
;STARTLIST=IMI_GOMBA
;STARTLIST=SIMUL_02
;STARTLIST=SIM_DP_01
;STARTLIST=FTP_SONATEST
;STARTLIST=L020
;STARTLIST=PING
;STARTLIST=VL27
;NB: mettere copy always ai file di conf x fare test...
;STARTLIST=2014
;STARTLIST=Tend_RAMA_10_47
;STARTLIST=3024-PING
;STARTLIST=2015
;STARTLIST=3024
;STARTLIST=SIMUL_01
;STARTLIST=WPS
STARTLIST=FTP-PING
MAXCNC=10
+120
View File
@@ -0,0 +1,120 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=SIMULA
PING_MS_TIMEOUT=500
MinDeltaSec=5
EnableRedisQueue=true
;IOB_NAME=TFT_RAMA_001
[MACHINE]
VENDOR=STEAMWARE
MODEL=DEMO_SIMULATOR
[CNC]
IP=127.0.0.1
PORT=0000
[SERVER]
MPIP=http://10.74.82.218
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
CMD_ODL_STARTED=/IOB/getCurrOdlStart/
CMD_FORCLE_SPLIT_ODL=/IOB/forceSplitOdlFull/
CMD_IDLE_TIME=/IOB/getIdlePeriod/
[MEMORY]
[BLINK]
MAX_COUNTER_BLINK = 15
BLINK_FILT=0
[OPTPAR]
DISABLE_SEND_WDST=TRUE
AUTO_CHANGE_ODL=true
AUTO_SNAPSHOT_DOSSIER=true
CHANGE_ODL_HOURS=24
CHANGE_ODL_IDLE_MIN=0
CHANGE_ODL_MODE=SIMUL
; gestione custom timer
timerIntMs=100
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=BIT
ENABLE_PZ_RESET=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; gestione cambio ODL automatico (minuti minimi durata)
MIN_DURATA_ODL=960
; per il simulatore: 50|1 = WAIT 50, DURATION 1 con riferimento al PERIODO base (PER_BASE in ms, default 10 secondi)
PER_BASE=10100
SIM_PZCNT=5|1
SIM_ALARM=100|10
SIM_MANU=50|6
; indica gestione e simulazione bit 5 --> slow
SIM_SLOW=3600|20
; indica gestione e simulazione bit 6 --> warmup/cooldown
SIM_WUCD=8000|20
; indica gestione e simulazione bit 7 --> emergenza
SIM_EMRG=4000|10
; indica simulazione delle funzionalità power ON/ OFF
SIM_POW_ON_OFF=true
T_ON=7
T_OFF=22
; indica simulazione controlli utente
SIM_RC=81|1
; indica simulazione registro scarti
SIM_RS=161|1
; indica simulazione dichiarazioni (note) utente
SIM_DICH=261|1
; indica matricola opr simulata
SIM_MATR_OPR=1
; test x datasync...
DATA_SYNC_AT_START=true
; test sim dossiers tipo Kepware
SIM_KWP=true
; gestione DynData simulati
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
NEW_DYN_DATA=TRUE
; indica parametri gestione TcMan
TC_MAX_TC_FACTOR=3.9
TC_LAMBDA=0.4
TC_MAX_INCR=5
MAX_PZ_INCR_PERC=1000
; conf parametri memoria READ/WRITE
PARAM_CONF=SIMUL_01.json
ALARM_CONF=SIMUL_01_alarm.json
;test gestione logfile (eg: soitaab)
EnabelPodlManFull=true
CodGruppoIob=STEAMWARE-SIM-FASE-01
; invio flux alla lettura file
sendFluxOnRead=true
;conf test FTP
FTP_SERVER=ftp.steamware.net
FTP_USER=testftpuser
FTP_PWD=we4reFromB3rghem!
FTP_CERT=
FTP_SKIP=TRUE
FTP_LOC_DIR=temp\csv
FTP_REM_DIR=
CSV_ADD_HEADER=true
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=Steamware
HostOS=WIN
HostName=IOB-WIN-SIMULA
HostAddr=10.74.82.76
+410
View File
@@ -0,0 +1,410 @@
{
"mMapWrite": {
"setArt": {
"name": "setArt",
"description": "Articolo",
"memAddr": "DB150.DBB12",
"tipoMem": "String",
"index": 12,
"size": 20,
"displOrdinal": 1
},
"setArtNum": {
"name": "setArtNum",
"description": "# Num Articolo",
"memAddr": "DB150.DBB112",
"tipoMem": "Int",
"index": 112,
"size": 4,
"displOrdinal": 1
},
"setComm": {
"name": "setComm",
"description": "Commessa",
"memAddr": "DB150.DBB32",
"tipoMem": "String",
"index": 32,
"size": 20,
"displOrdinal": 2
},
"setCommNum": {
"name": "setCommNum",
"description": "# NumCommessa",
"memAddr": "DB150.DBB132",
"tipoMem": "Int",
"index": 132,
"size": 4,
"displOrdinal": 2
},
"setPzComm": {
"name": "setPzComm",
"description": "Qta Richiesta",
"memAddr": "DB150.DBB8",
"tipoMem": "Int",
"index": 8,
"size": 4,
"displOrdinal": 3
},
"forceSetPzCount": {
"name": "forceSetPzCount",
"description": "Imposta Qta",
"memAddr": "DB150.DBB8",
"tipoMem": "Int",
"index": 8,
"size": 4,
"displOrdinal": 11
},
//"OPC_Set Point.Chain Spped": {
// "name": "OPC_Set Point.Chain Spped",
// "description": "Chain Spped",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Chain Spped",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Top Overfeeding": {
// "name": "OPC_Set Point.Top Overfeeding",
// "description": "Top Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Top Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Bottom Overfeeding": {
// "name": "OPC_Set Point.Bottom Overfeeding",
// "description": "Bottom Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Bottom Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Width Master": {
// "name": "OPC_Set Point.Width Master",
// "description": "Width Master",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Width Master",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Thermoset Time": {
// "name": "OPC_Set Point.Thermoset Time",
// "description": "Thermoset Time",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Thermoset Time",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Thermoset Temperature": {
// "name": "OPC_Set Point.Thermoset Temperature",
// "description": "Thermoset Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Thermoset Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Take Off Overfeeding": {
// "name": "OPC_Set Point.Take Off Overfeeding",
// "description": "Take Off Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Take Off Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Small Roller Overfeeding": {
// "name": "OPC_Set Point.Small Roller Overfeeding",
// "description": "Small Roller Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Small Roller Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Scroll Roller Overfeeding": {
// "name": "OPC_Set Point.Scroll Roller Overfeeding",
// "description": "Scroll Roller Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Scroll Roller Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Right Whell Overfeeding": {
// "name": "OPC_Set Point.Right Whell Overfeeding",
// "description": "Right Whell Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Right Whell Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Plaiter Overfeeding": {
// "name": "OPC_Set Point.Plaiter Overfeeding",
// "description": "Plaiter Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Plaiter Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Load cell Weight": {
// "name": "OPC_Set Point.Load cell Weight",
// "description": "Load cell Weight",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Load cell Weight",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Left Wheel Overfeeding": {
// "name": "OPC_Set Point.Left Wheel Overfeeding",
// "description": "Left Wheel Overfeeding",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Left Wheel Overfeeding",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Fan 105A Speed": {
// "name": "OPC_Set Point.Fan 105A Speed",
// "description": "Fan 105A Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Fan 105A Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Fan 105 Speed": {
// "name": "OPC_Set Point.Fan 105 Speed",
// "description": "Fan 105 Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Fan 105 Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Fan 103A Speed": {
// "name": "OPC_Set Point.Fan 103A Speed",
// "description": "Fan 103A Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Fan 103A Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Fan 103 Speed": {
// "name": "OPC_Set Point.Fan 103 Speed",
// "description": "Fan 103 Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Fan 103 Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Fan 101A Speed": {
// "name": "OPC_Set Point.Fan 101A Speed",
// "description": "Fan 101A Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Fan 101A Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Fan 101 Speed": {
// "name": "OPC_Set Point.Fan 101 Speed",
// "description": "Fan 101 Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Fan 101 Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Exhaust Fan 1 Speed": {
// "name": "OPC_Set Point.Exhaust Fan 1 Speed",
// "description": "Exhaust Fan 1 Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Exhaust Fan 1 Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Differentiation Spindle 5": {
// "name": "OPC_Set Point.Differentiation Spindle 5",
// "description": "Differentiation Spindle 5",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Differentiation Spindle 5",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Differentiation Spindle 4": {
// "name": "OPC_Set Point.Differentiation Spindle 4",
// "description": "Differentiation Spindle 4",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Differentiation Spindle 4",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Differentiation Spindle 3": {
// "name": "OPC_Set Point.Differentiation Spindle 3",
// "description": "Differentiation Spindle 3",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Differentiation Spindle 3",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Differentiation Spindle 2": {
// "name": "OPC_Set Point.Differentiation Spindle 2",
// "description": "Differentiation Spindle 2",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Differentiation Spindle 2",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Differentiation Spindle 1": {
// "name": "OPC_Set Point.Differentiation Spindle 1",
// "description": "Differentiation Spindle 1",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Differentiation Spindle 1",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Cooling Cell 1 Speed": {
// "name": "OPC_Set Point.Cooling Cell 1 Speed",
// "description": "Cooling Cell 1 Speed",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Cooling Cell 1 Speed",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Burner 6 Temperature": {
// "name": "OPC_Set Point.Burner 6 Temperature",
// "description": "Burner 6 Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Burner 6 Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Burner 5 Temperature": {
// "name": "OPC_Set Point.Burner 5 Temperature",
// "description": "Burner 5 Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Burner 5 Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Burner 4 Temperature": {
// "name": "OPC_Set Point.Burner 4 Temperature",
// "description": "Burner 4 Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Burner 4 Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Burner 3 Temperature": {
// "name": "OPC_Set Point.Burner 3 Temperature",
// "description": "Burner 3 Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Burner 3 Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Burner 2 Temperature": {
// "name": "OPC_Set Point.Burner 2 Temperature",
// "description": "Burner 2 Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Burner 2 Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Burner 1 Temperature": {
// "name": "OPC_Set Point.Burner 1 Temperature",
// "description": "Burner 1 Temperature",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Burner 1 Temperature",
// "index": 0,
// "size": 0
//},
//"OPC_Set Point.Air Humidity Preset Esa 1": {
// "name": "OPC_Set Point.Air Humidity Preset Esa 1",
// "description": "Air Humidity Preset Esa 1",
// "tipoMem": "String",
// "memAddr": "ns=2;s=RamosaETN21.RamosaCJ2.Recipe.Air Humidity Preset Esa 1",
// "index": 0,
// "size": 0
//}
},
"mMapRead": {
"TEMP_01": {
"name": "TEMP_01",
"description": "Temperatura 01",
"tipoMem": "Real",
"minVal": 18,
"maxVal": 24,
"displOrdinal": 4
},
"POWER_01": {
"name": "POWER_01",
"description": "Potenza impianto",
"tipoMem": "Int",
"minVal": 40,
"maxVal": 80,
"displOrdinal": 5
},
"FEED_OVER": {
"name": "FEED_OVER",
"description": "FEED override",
"tipoMem": "Int",
"minVal": 0,
"maxVal": 100,
"displOrdinal": 6
},
"RAPID_OVER": {
"name": "RAPID_OVER",
"description": "RAPID override",
"tipoMem": "Int",
"minVal": 50,
"maxVal": 120,
"displOrdinal": 7
},
"POS_X": {
"name": "POS_X",
"description": "Asse X",
"tipoMem": "Int",
"minVal": -2000,
"maxVal": 2000,
"displOrdinal": 8
},
"POS_Y": {
"name": "POS_Y",
"description": "Asse Y",
"tipoMem": "Int",
"minVal": 0,
"maxVal": 2000,
"displOrdinal": 9
},
"POS_Z": {
"name": "POS_Z",
"description": "Asse Z",
"tipoMem": "Int",
"minVal": 0,
"maxVal": 1500,
"displOrdinal": 10
}
},
"optKVP": {
"fluxLogReduce": true,
"fluxLogRedDeadBand": 1.5,
"fluxLogResendPeriod": 15,
"hasRecipe": true,
"maxPodlQty": 530,
"useLocalRecipe": true,
"path-locBase": "C:\\MesData\\",
"path-00-Arch": "ArchivioRicette\\FIMAT",
"path-01-Temp": "01-Temp\\FIMAT",
"path-02-Sent": "02-Inviate\\FIMAT",
"path-03-Recv": "03-Ricevute\\FIMAT",
"path-04-remReq": "Y:\\",
"path-05-remExe": "C:\\MesData\\Remote\\Dosed",
"path-06-remRec": "R:\\",
"path-outReport": "C:\\MesData\\Report",
"path-confSetup": "C:\\MesData\\Setup\\setupConsumi.json",
"replace-<Variant>": "<Variant>{{PODL}}",
"replace-<Info1>": "<Info1>Kg{{Qty}} | {{Note}}"
}, //,
//"BaseKeyTranslate": "ns=2;s=RamosaETN21.RamosaCJ2",
//"RecipeKeyTranslate": {
// "Present Value.General Fan": "Recipe.Chain Spped",
// "Present Value.Bottom Overfeeding": "Recipe.Bottom Overfeeding",
// "Present Value.Top Overfeeding": "Recipe.Top Overfeeding"
//}
"mMapWriteLink": {
"setArt": "setArtNum",
"setComm": "setCommNum"
}
}
+51
View File
@@ -0,0 +1,51 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=PingWatchdog
PING_MS_TIMEOUT=500
; attenzione che alcuni eventi vengo scritti cmq nel log di SIMUL_01 invece di SIMUL_01_WD
IOB_NAME=SIMUL_01
[MACHINE]
VENDOR=STEAMWARE
MODEL=WATCHDOG
[CNC]
; ping vs WIN10-VPN-03 per test
IP=10.74.83.203
PORT=0000
[SERVER]
MPIP=http://10.74.82.218
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
CMD_ODL_STARTED=/IOB/getCurrOdlStart/
CMD_FORCLE_SPLIT_ODL=/IOB/forceSplitOdlFull/
CMD_IDLE_TIME=/IOB/getIdlePeriod/
[MEMORY]
[BLINK]
MAX_COUNTER_BLINK = 15
BLINK_FILT=0
[OPTPAR]
AUTO_CHANGE_ODL=false
POWEROFF_TIMEOUT_SEC=60
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=Steamware
HostOS=WIN
HostName=IOB-WIN-SIMULA
HostAddr=10.74.82.76
+859
View File
@@ -0,0 +1,859 @@
[
{
"description": "Alarm Word 0 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 0",
"index": 0,
"size": 2,
"messages": [
"1,ALLARME INVERTER CATENA TRASP. TESSUTO",
"2,ALLARME INVERTER CILINDRO SOVRALIMENTAZIONE SUPERIORE",
"3,ALLARME INVERTER CILINDRO SOVRALIMENTAZIONE INFERIORE",
"4,ALLARME INVERTER RUOTA SOVRALIMENTAZIONE SINISTRA",
"5,ALLARME INVERTER RUOTA SOVRALIMENTAZIONE DESTRA",
"6,ALLARME INVERTER STACCAPEZZA",
"7,ALLARME INVERTER FALDAROTOLATORE",
"8,ALLARME INVERTER FALDERUOLE",
"9,ALLARME INVERTER ESAUSTORE 1 ",
"10,ALLARME FUNE SICUREZZA USCITA",
"11,ALLARME VENTILATORE 1 (BASSO)",
"12, ALLARME VENTILATORE 2 (BASSO)",
"13,ALLARME F.C. MINIMO CAMPO MASTER",
"14,ALLARME F.C. MASSIMO CAMPO MASTER",
"15,ALLARME PROTEZIONE TAPPETO INGRESSO",
"16,RIFERIMENTO POTENZIOMETRI CAMPI ASSENTE"
]
},
{
"description": "Alarm Word 1 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 1",
"index": 1,
"size": 2,
"messages": [
"17,ALLARME CONDIZIONATORI",
"18,EMERGENZA IN CORSO !!!",
"19,ALLARME PROTEZIONE RECUPERO CALORE - GRUPPO 2 POMPA 1",
"20,ALLARME POMPA RECUPERO CALORE 3",
"21,CONTROLLO UMIDITA' : FUORI CAMPO",
"22,ALLARME RILEVATORE ALTEZZA TESSUTO",
"23,ALLARME NON RILASCIO TESSUTO SINISTRO",
"24,ALLARME NON RILASCIO TESSUTO DESTRO",
"25,ALLARME ALIMENTAZIONE 24VAC QUADRO",
"26,ALLARME APRICIMOSSE",
"27,ALLARME ASCIUGACIMOSSE A INFRAROSSI",
"28,ALLARME PROTEZIONE CELLA DI RAFFREDDAMENTO 1",
"29,CAMPO PARALLELO 2 ALLARME PROTEZIONE",
"30,ALLARME VENTILATORE 3 (BASSO)",
"31,ALLARME VENTILATORE 4 (BASSO)",
"32,CAMPO PARALLELO 1 ALLARME PROTEZIONE"
]
},
{
"description": "Alarm Word 2 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 2",
"index": 2,
"size": 2,
"messages": [
"33,CAMPO PARALLELO 3 ALLARME PROTEZIONE",
"34,RAGGIUNTO MASSIMO CARICO CELLA DI CARICO TAPPETO",
"35,ALLARME FALLOPEZZA SINISTRO",
"36,ALLARME FALLOPEZZA DESTRO",
"37,PARATIE ANTERIORI APERTE",
"38,ALLARME AZIONAMENTO CAMPO CONICO",
"39,BLOCCO BRUCIATORE 9",
"40,CAMPO MASTER ALLARME PROTEZIONE ",
"41,ALLARME PRESSOSTATO TENDICATENA SINISTRO",
"42,ALLARME PRESSOSTATO TENDICATENA DESTRO",
"43,ALLARME MASSIMO ALLUNGAMENTO CATENA",
"44,ALLARME TIPO LAVORO USCITA NON SELEZIONATO",
"45,ALLARME RADDRIZZATRAMA",
"46,ALLARME SPREMITORE 1",
"47,BLOCCO BRUCIATORE 10",
"48,BLOCCO BRUCIATORE 11"
]
},
{
"description": "Alarm Word 3 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 3",
"index": 3,
"size": 2,
"messages": [
"49,BLOCCO BRUCIATORE 12",
"50,BLOCCO BRUCIATORE 1",
"51,BLOCCO BRUCIATORE 2",
"52,BLOCCO BRUCIATORE 3",
"53,BLOCCO BRUCIATORE 4",
"54,BIELLE FUORI POSIZIONE",
"55,GRUPPO FALDATORE FUORI POSIZIONE",
"56,SERIE ARRESTI APERTA",
"57,MANCANZA LUBRIFICANTE CATENA TRASP. TESSUTO",
"58,ALLARME INVERTER PICCOLO ROTOLO",
"59,ALLARME PROTEZIONE ALLARGATORI",
"60,ALLARME PROTEZIONE ASPIRACIMOSSE",
"61,ALLARME TAGLIACIMOSSE SINISTRA",
"62,ALLARME TAGLIACIMOSSE DESTRA",
"63,ALLARME INVERTER VENTILATORI INV101",
"64,ALLARME INVERTER VENTILATORI INV103"
]
},
{
"description": "Alarm Word 4 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 4",
"index": 4,
"size": 2,
"messages": [
"65,ALLARME TIMEOUT VITE CAMPO MASTER",
"66,ALLARME TIMEOUT VITE CAMPO PARALLELO 1",
"67,ALLARME TIMEOUT VITE CAMPO PARALLELO 2",
"68,ALLARME TIMEOUT VITE CAMPO PARALLELO 3",
"69,ALLARME TIMEOUT VITE CAMPO PARALLELO 4",
"70,ALLARME TIMEOUT VITE CAMPO PARALLELO 5",
"71,ALLARME TIMEOUT VITE CAMPO PARALLELO 6",
"72,ALLARME TIMEOUT VITE CAMPO PARALLELO 7",
"73,ALLARME TIMEOUT VITE CAMPO PARALLELO 8",
"74,ALLARME TIMEOUT VITE CAMPO PARALLELO 9",
"75,ALLARME DEVICE_NET ADDR. 32 DA BANCHETTO DI SPALMATURA",
"76,ALLARME INVERTER DOGAL ",
"77,ALLARME FOTOCELLULA TAPPETO USCITA PIENO",
"78,TEMPO DI CICLO PLC SOPRA MASSIMO IMPOSTATO",
"79,ERRORE INDIRIZZI SONDE BRUCIATORI",
"80,ALLARME VENTILATORE 4 (ALTO)"
]
},
{
"description": "Alarm Word 5 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 5",
"index": 5,
"size": 2,
"messages": [
"81,ALLARME VENTILATORE 5 (ALTO)",
"82,ALLARME VENTILATORE 6 (ALTO)",
"83,ALLARME VENTILATORE 7 (ALTO)",
"84,SONDA BRUCIATORE 1 INTERROTTA",
"85,SONDA BRUCIATORE 2 INTERROTTA",
"86,SONDA BRUCIATORE 3 INTERROTTA",
"87,SONDA BRUCIATORE 4 INTERROTTA",
"88,ALLARME DEVICE_NET ADDR. 0",
"89,ALLARME DEVICE_NET ADDR. 1",
"90,ALLARME DEVICE_NET ADDR. 2",
"91,ALLARME DEVICE_NET ADDR. 3",
"92,ALLARME DEVICE_NET ADDR. 4",
"93,ALLARME DEVICE_NET ADDR. 5",
"94,ALLARME DEVICE_NET ADDR. 6",
"95,ALLARME DEVICE_NET ADDR. 7",
"96,ALLARME DEVICE_NET ADDR. 8"
]
},
{
"description": "Alarm Word 6 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 6",
"index": 6,
"size": 2,
"messages": [
"97,ALLARME DEVICE_NET ADDR. 9",
"98,ALLARME DEVICE_NET ADDR. 10",
"99,ALLARME DEVICE_NET ADDR. 11",
"100,ALLARME DEVICE_NET ADDR. 12",
"101,ALLARME DEVICE_NET ADDR. 13",
"102,ALLARME DEVICE_NET ADDR. 14",
"103,ALLARME DEVICE_NET ADDR. 15",
"104,ALLARME DEVICE_NET ADDR. 16",
"105,ALLARME DEVICE_NET ADDR. 17",
"106,ALLARME DEVICE_NET ADDR. 18",
"107,ALLARME DEVICE_NET ADDR. 19",
"108,ALLARME DEVICE_NET ADDR. 20",
"109,ALLARME DEVICE_NET ADDR. 21",
"110,ALLARME DEVICE_NET ADDR. 22",
"111,ALLARME DEVICE_NET ADDR. 23",
"112,ALLARME DEVICE_NET ADDR. 24"
]
},
{
"description": "Alarm Word 7 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 7",
"index": 7,
"size": 2,
"messages": [
"113,ALLARME DEVICE_NET ADDR. 25",
"114,ALLARME DEVICE_NET ADDR. 26",
"115,BLOCCO BRUCIATORE 5",
"116,BLOCCO BRUCIATORE 6",
"117,BLOCCO BRUCIATORE 7",
"118,BLOCCO BRUCIATORE 8",
"119,SOVRATEMPERATURA BRUCIATORE 1",
"120,SOVRATEMPERATURA BRUCIATORE 2",
"121,SOVRATEMPERATURA BRUCIATORE 3",
"122,SOVRATEMPERATURA BRUCIATORE 4",
"123,SOVRATEMPERATURA BRUCIATORE 5",
"124,SOVRATEMPERATURA BRUCIATORE 6",
"125,SOVRATEMPERATURA BRUCIATORE 7",
"126,SOVRATEMPERATURA BRUCIATORE 8",
"127,SONDA BRUCIATORE 5 INTERROTTA",
"128,SONDA BRUCIATORE 6 INTERROTTA"
]
},
{
"description": "Alarm Word 8 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 8",
"index": 8,
"size": 2,
"messages": [
"129,SONDA BRUCIATORE 7 INTERROTTA",
"130,SONDA BRUCIATORE 8 INTERROTTA",
"131,SONDA BRUCIATORE 9 INTERROTTA",
"132,SONDA BRUCIATORE 10 INTERROTTA",
"133,SONDA BRUCIATORE 11 INTERROTTA",
"134,SONDA BRUCIATORE 12 INTERROTTA",
"135,SOVRATEMPERATURA BRUCIATORE 9",
"136,SOVRATEMPERATURA BRUCIATORE 10",
"137,SOVRATEMPERATURA BRUCIATORE 11",
"138,SOVRATEMPERATURA BRUCIATORE 12",
"139,ALLARME INVERTER VENTILATORI INV105",
"140,ALLARME INVERTER VENTILATORI INV107",
"141,ALLARME INVERTER VENTILATORI INV109",
"142,ALLARME INVERTER VENTILATORI INV111",
"143,ALLARME VENTILATORE 5 (BASSO)",
"144,ALLARME VENTILATORE 6 (BASSO)"
]
},
{
"description": "Alarm Word 9 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 9",
"index": 9,
"size": 2,
"messages": [
"145,ALLARME VENTILATORE 7 (BASSO)",
"146,ALLARME VENTILATORE 8 (BASSO)",
"147,ALLARME VENTILATORE 9 (BASSO)",
"148,ALLARME VENTILATORE 10 (BASSO)",
"149,ALLARME VENTILATORE 11 (BASSO)",
"150,ALLARME VENTILATORE 12 (BASSO)",
"151,ALLARME INVERTER ESAUSTORE 2",
"152,CAMPO PARALLELO 4 ALLARME PROTEZIONE",
"153,CAMPO PARALLELO 5 ALLARME PROTEZIONE",
"154,CAMPO PARALLELO 6 ALLARME PROTEZIONE",
"155,CAMPO PARALLELO 7 ALLARME PROTEZIONE",
"156,CAMPO PARALLELO 8 ALLARME PROTEZIONE",
"157,ALLARME INSEGUIMENTO VITE MASTER AGGIUNTA",
"158,ALLARME INVERTER CILINDRO RAFFREDDAMENTO",
"159,ALLARME TEMPERATURA ESAUSTORI",
"160,ALLARME INVERTER RECUPERO CALORE GRUPPO 1 "
]
},
{
"description": "Alarm Word 10 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 10",
"index": 10,
"size": 2,
"messages": [
"161,ALLARME FINECORSA SX TAPPETO USCITA",
"162,ALLARME FINECORSA DX TAPPETO USCITA",
"163,ALLARME INVERTER RECUPERO CALORE GRUPPO 2",
"164,ALLARME DEVICE_NET ADDR. 31",
"165,ALLARME CENTRATORE USCITA",
"166,COMPATTATORE NON PRONTO",
"167,ALLARME CONTROLLO PIROMETRI",
"168,ALLARME ALLARGATORE SU TAPPETO USCITA",
"169,ALLARME CONTROLLO FUMI",
"170,ALLARME FINECORSA BALLERINO ALTO",
"171,ALLARME FINECORSA BALLERINO BASSO",
"172,ALLARME PROTEZIONE ASPIRATORE VAPORIZZO INTENSIVO",
"173,ALLARME PROTEZIONE BRUCIATORE 1",
"174,ALLARME PROTEZIONE BRUCIATORE 2",
"175,ALLARME PROTEZIONE BRUCIATORE 3",
"176,ALLARME PROTEZIONE BRUCIATORE 4"
]
},
{
"description": "Alarm Word 11 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 11",
"index": 11,
"size": 2,
"messages": [
"177,ALLARME PROTEZIONE BRUCIATORE 5",
"178,ALLARME PROTEZIONE BRUCIATORE 6",
"179,ALLARME PROTEZIONE BRUCIATORE 7",
"180,ALLARME PROTEZIONE BRUCIATORE 8",
"181,ALLARME PROTEZIONE BRUCIATORE 9",
"182,ALLARME PROTEZIONE BRUCIATORE 10",
"183,ALLARME PROTEZIONE BRUCIATORE 11",
"184,ALLARME PROTEZIONE BRUCIATORE 12",
"185,TERMOFISSAGGIO O ESSICCAZIONE: TEMPERATURA FUORI CAMPO",
"186,TERMOFISSAGGIO O ESSICCAZIONE: VELOCITA' FUORI CAMPO",
"187,TERMOFISSAGGIO O ESSICCAZIONE: TEMPO FUORI CAMPO",
"188,SISTEMA CAMPI PARALLELI NON TARATO",
"189,ALLARME PROTEZIONE VENTOLE BRUCIATORI",
"190,CAMPO CONICO SINISTRO SU LIMITE CHIUSURA",
"191,CAMPO CONICO SINISTRO SU LIMITE APERTURA",
"192,CAMPO CONICO DESTRO SU LIMITE APERTURA"
]
},
{
"description": "Alarm Word 12 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 12",
"index": 12,
"size": 2,
"messages": [
"193,CAMPO CONICO DESTRO SU LIMITE CHIUSURA",
"194,FINECORSA CAMPO CONICO DESTRO SU TRAVERSA",
"195,FINECORSA CAMPO CONICO SINISTRO SU TRAVERSA",
"196,ALLARME PROTEZIONE INVERTER CAMPO CONICO SINISTRO",
"197,ALLARME PROTEZIONE INVERTER CAMPO CONICO DESTRO",
"198,ALLARME DEVICE_NET ADDR. 27",
"199,ALLARME VENTILATORE 8 (ALTO)",
"200,ALLARME VENTILATORE 9 (ALTO)",
"201,ALLARME VENTILATORE 10 (ALTO)",
"202,ALLARME VENTILATORE 11 (ALTO)",
"203,ALLARME VENTILATORE 12 (ALTO)",
"204,ALLARME VENTILATORE 1 (ALTO)",
"205,ALLARME VENTILATORE 2 (ALTO)",
"206,ALLARME VENTILATORE 3 (ALTO)",
"207,ALLARME PROTEZIONE CELLA DI RAFFREDDAMENTO 2",
"208,ALLARME FINECORSA TANDEM CONTROLLO ANSA TESSUTO"
]
},
{
"description": "Alarm Word 13 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 13",
"index": 13,
"size": 2,
"messages": [
"209,ALLARME FUNE SICUREZZA / PROTEZIONE RIBALTABILE ANTERIORE",
"210,ALLARME INVERTER VENTILATORI INV101A",
"211,ALLARME INVERTER VENTILATORI INV103A",
"212,ALLARME INVERTER VENTILATORI INV105A",
"213,ALLARME INVERTER VENTILATORI INV107A",
"214,ALLARME INVERTER VENTILATORI INV109A",
"215,ALLARME INVERTER VENTILATORI INV111A",
"216,ALLARME DA BANCHETTO DI SPALMATURA",
"217,ALLARME DEVICE_NET ADDR. 28",
"218,STOP JOG USCITA PER PESO RAGGIUNTO SU CELLA DI CARICO",
"219,DOGAL NON PRONTO",
"220,ALLARME PROTEZIONE CELLA RAFFREDDAMENTO 91A",
"221,MALFUNZIONAMENTO RECUPERO CALORE GRUPPO 1",
"222,ALLARME PROTEZIONE SOSTEGNO TESSUTO",
"223,TARATURA CAMPI CONICI NON EFFETTUATA!",
"224,ALLARME TIMEOUT VITE CAMPO PARALLELO 10"
]
},
{
"description": "Alarm Word 14 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 14",
"index": 14,
"size": 2,
"messages": [
"225,CAMPO PARALLELO 9 ALLARME PROTEZIONE",
"226,CAMPO PARALLELO 10 ALLARME PROTEZIONE",
"227,CAMPO PARALLELO 11 ALLARME PROTEZIONE",
"228,CAMPO PARALLELO 12 ALLARME PROTEZIONE",
"229,ALLARME FLUSSOSTATO RECUPERO CALORE 1",
"230,ALLARME FLUSSOSTATO RECUPERO CALORE 2",
"231,ALLARME FLUSSOSTATO RECUPERO CALORE 3",
"232,ALLARME PROTEZIONE VENTILATORE ASCIUGACIMOSSE",
"233,ALLARME PROTEZIONE RESISTENZE ASCIUGACIMOSSE",
"234,ALLARME PROTEZIONE RECUPERO CALORE - GRUPPO 1 POMPA 1 ",
"235,ALLARME INCENDIO",
"236,ATTENZIONE ! ALLARME PRESENTE SU BANCHETTO DI SPALMATURA",
"237,MALFUNZIONAMENTO RECUPERO CALORE GRUPPO 2",
"238,ALLARME PROTEZIONE CELLA RAFFREDDAMENTO 91B",
"239,ALLARME PROTEZIONE PULISCISPILLI",
"240,BATTERIA PLC - LIVELLO BASSO"
]
},
{
"description": "Alarm Word 15 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 15",
"index": 15,
"size": 2,
"messages": [
"241,ALLARME CONTEMPORANEIT? TERMOSTATI SICUREZZA BRUCIATORI",
"242,BLOCCO VERSIONE SOFTWARE",
"243,SROTOLATORE NON PRONTO",
"244,ERRORE DI COMUNICAZIONE PROTOCOL MACRO",
"245,ALLARME TAGLIERINA URBAN",
"246,FINE TESSUTO IN INGRESSO",
"247,ALLARME PROTEZIONE SERVOVENTILAZIONI MOTORI",
"248,ALLARME INVERTER ARROTOLATORE TANGENZIALE",
"249,ALLARME SPREMITORE 2",
"250,ALLARME FS-91ER PLEVA",
"251,ALLARME LINEA EMERGENZA ARROTOLATORE",
"252,ALLARME FOTOCELLULE ARROTOLATORE",
"253,PORTA CASSETTA USCITA RAMOSA APERTA",
"254,ALLARME FINECORSA CILINDRO PROTEZIONE ARROTOLATORE ASSIALE",
"255,ALLARME PRESSOSTATI GRUPPO VALVOLE USCITA",
"256,ARROTOLATORE NON PRONTO"
]
},
{
"description": "Alarm Word 16 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 16",
"index": 16,
"size": 2,
"messages": [
"257,FINECORSA GRUPPO FALDATORE AVANTI",
"258,FINECORSA GRUPPO FALDATORE INDIETRO",
"259,ALLARME BATTERIA ELETTRICA 1",
"260,SOVRATEMPERATURA BATTERIA ELETTRICA 5",
"261,ALLARME BATTERIA ELETTRICA 2",
"262,RISCALDAMENTO QUADRO SPENTO",
"263,SOVRATEMPERATURA BATTERIA ELETTRICA 1",
"264,SOVRATEMPERATURA BATTERIA ELETTRICA 2",
"265,ALLARME BATTERIA ELETTRICA 3",
"266,EMERGENZA DA SPALMATRICE",
"267,ALLARME BATTERIA ELETTRICA 4",
"268,ALLARME BATTERIA ELETTRICA 5",
"269,SOVRATEMPERATURA BATTERIA ELETTRICA 3",
"270,SOVRATEMPERATURA BATTERIA ELETTRICA 4",
"271,ALLARME IDROSTATO RECUPERO CALORE 1",
"272,ALLARME SENSORE LIVELLO RECUPERO CALORE 1 : AGGIUNGERE LIQUIDO !"
]
},
{
"description": "Alarm Word 17 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 17",
"index": 17,
"size": 2,
"messages": [
"273,ALLARME RELE' CONTROLLO FASI",
"274,ALLARME DEVICE NET ADDR. 40 - MODULO GRT1-DRT USCITA RAMOSA",
"275,ALLARME PRESSOSTATO LINEA ENTRATA MACCHINA",
"276,ALLARME PRESSOSTATO LINEA USCITA MACCHINA",
"277,CAMPO CANNOCCHIALI 1 BLOCCATO",
"278,CAMPO CANNOCCHIALI 2 BLOCCATO",
"279,ALLARME DISCONTINUITA' CAMPI PARALLELI",
"280,ALLARME INSEGUIMENTO CAMPI PARALLELI - VITE LENTA",
"281,ALLARME LIMITE VITI",
"282,RAGGIUNTO MASSIMO CARICO SU CELLA DI CARICO",
"283,ALLARME PRESSOSTATO ESAUSTORE",
"284,EMERGENZA MOVIMENTO TESSUTO",
"285,EMERGENZA DA SPREMITORE 1",
"286,EMERGENZA DA RADDRIZZATRAMA",
"287,EMERGENZA DA SROTOLATORE",
"288,EMERGENZA DA ARROTOLATORE"
]
},
{
"description": "Alarm Word 18 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 18",
"index": 18,
"size": 2,
"messages": [
"289,ALLARME SICUREZZA BRUCIATORE 1",
"290,ALLARME SICUREZZA BRUCIATORE 2",
"291,ALLARME SICUREZZA BRUCIATORE 3",
"292,ALLARME SICUREZZA BRUCIATORE 4",
"293,ALLARME SICUREZZA BRUCIATORE 5",
"294,ALLARME SICUREZZA BRUCIATORE 6",
"295,ALLARME SICUREZZA BRUCIATORE 7",
"296,ALLARME SICUREZZA BRUCIATORE 8",
"297,ALLARME SICUREZZA BRUCIATORE 9",
"298,ALLARME SICUREZZA BRUCIATORE 10",
"299,ALLARME SICUREZZA BRUCIATORE 11",
"300,ALLARME SICUREZZA BRUCIATORE 12",
"301,ALLARME BRUCIATORE 1 SPENTO",
"302,ALLARME BRUCIATORE 2 SPENTO",
"303,ALLARME BRUCIATORE 3 SPENTO",
"304,ALLARME BRUCIATORE 4 SPENTO"
]
},
{
"description": "Alarm Word 19 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 19",
"index": 19,
"size": 2,
"messages": [
"305,ALLARME BRUCIATORE 5 SPENTO",
"306,ALLARME BRUCIATORE 6 SPENTO",
"307,ALLARME BRUCIATORE 7 SPENTO",
"308,ALLARME BRUCIATORE 8 SPENTO",
"309,ALLARME BRUCIATORE 9 SPENTO",
"310,ALLARME BRUCIATORE 10 SPENTO",
"311,ALLARME BRUCIATORE 11 SPENTO",
"312,ALLARME BRUCIATORE 12 SPENTO",
"313,ALLARME SENSORE LIVELLO RECUPERO CALORE 2 : AGGIUNGERE LIQUIDO !",
"314,ALLARME DA MIXER",
"315,ALLARME PRESSOSTATI LUBRIFICAZIONE",
"316,ALLARME ABBATTITORE FUMI",
"317,MACCHINA 1 NON IN LINEA",
"318,MACCHINA 2 NON IN LINEA",
"319,MACCHINA 3 NON IN LINEA",
"320,MACCHINA 4 NON IN LINEA"
]
},
{
"description": "Alarm Word 20 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 20",
"index": 20,
"size": 2,
"messages": [
"321,MACCHINA 5 NON IN LINEA",
"322,MACCHINA 6 NON IN LINEA",
"323,MACCHINA 7 NON IN LINEA",
"324,MACCHINA 8 NON IN LINEA",
"325,NON STOP NON PRONTO",
"326,EMERGENZA DA NON STOP",
"327,ALLARME DISCONTINUITA' CAMPO MASTER",
"328,ALLARME DISCONTINUITA' CAMPO PARALLELO 1",
"329,ALLARME DISCONTINUITA' CAMPO PARALLELO 2",
"330,ALLARME DISCONTINUITA' CAMPO PARALLELO 3",
"331,ALLARME DISCONTINUITA' CAMPO PARALLELO 4",
"332,ALLARME DISCONTINUITA' CAMPO PARALLELO 5",
"333,ALLARME DISCONTINUITA' CAMPO PARALLELO 6",
"334,ALLARME DISCONTINUITA' CAMPO PARALLELO 7",
"335,ALLARME DISCONTINUITA' CAMPO PARALLELO 8",
"336,ALLARME DISCONTINUITA' CAMPO PARALLELO 9"
]
},
{
"description": "Alarm Word 21 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 21",
"index": 21,
"size": 2,
"messages": [
"337,ALLARME DISCONTINUITA' CAMPO PARALLELO 10",
"338,PROTEZIONI INGRESSO APERTE",
"339,PROTEZIONI USCITA APERTE",
"340,ALLARME PROTEZIONE ESTRATTORE FUMI 1",
"341,ALLARME PROTEZIONE ESTRATTORE FUMI 2",
"342,MANCANZA PRESSOSTATO ESTRATTORE FUMI 1",
"343,MANCANZA PRESSOSTATO ESTRATTORE FUMI 2",
"344,EMERGENZA DA MIXER",
"345,EMERGENZA DA SPREMITORE 2",
"346,ALLARME PROTEZIONE VENTILATORE RECUPERO CALORE 1",
"347,ALLARME PROTEZIONE VENTILATORE RECUPERO CALORE 2",
"348,ALLARME MODULO VELOCITA? ZERO CATENA TRASP. TESSUTO",
"349,ALLARME RILEVAMENTO TESSUTO SINISTRO USCITA",
"350,ALLARME RILEVAMENTO TESSUTO DESTRO USCITA",
"351,ALLARME FINECORSA SOLLEVAMENTO CAMPI CONICI",
"352,ALLARME IDROSTATO RECUPERO CALORE 2"
]
},
{
"description": "Alarm Word 22 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 22",
"index": 22,
"size": 2,
"messages": [
"353,ALLARME FUNE DI PROTEZIONE IN USCITA",
"354,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 1",
"355,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 2",
"356,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 3",
"357,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 4",
"358,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 5",
"359,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 6",
"360,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 7",
"361,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 8",
"362,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 9",
"363,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 10",
"364,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 11",
"365,ALLARME PROTEZIONE VENTOLA BRUCIATORE MAXON 12",
"366,OLIO CATENA - PRESSIONE MINIMA",
"367,POMPA OLIO CATENA - ALLARME PROTEZIONE",
"368,JBOX INGRESSO - BALLERINO BASSO"
]
},
{
"description": "Alarm Word 23 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 23",
"index": 23,
"size": 2,
"messages": [
"369,JBOX INGRESSO - FINE TESSUTO",
"370,JBOX INGRESSO - PIENO",
"371,JBOX INGRESSO - BALLERINO ALTO",
"372,JBOX INGRESSO - VUOTO",
"373,JBOX USCITA - BALLERINO BASSO",
"374,JBOX USCITA - FINE TESSUTO",
"375,JBOX USCITA - PIENO",
"376,JBOX USCITA - BALLERINO ALTO",
"377,JBOX USCITA - VUOTO",
"378,JBOX USCITA - ALLARME PRESSOSTATO",
"379,JBOX ENTRATA - ALLARME PRESSOSTATO",
"380,ALLARME PROTEZIONE CARRELLO FALDATORE",
"381,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 1",
"382,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 2",
"383,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 3",
"384,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 4"
]
},
{
"description": "Alarm Word 24 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 24",
"index": 24,
"size": 2,
"messages": [
"385,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 5",
"386,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 6",
"387,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 7",
"388,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 8",
"389,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 9",
"390,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 10",
"391,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 11",
"392,RISCALDAMENTO INDIRETTO - ALLARME FEEDBACK SERRANDA BR. 12",
"393,ESTRATTORE FUMI RISC. INDIRETTO 1 - ALLARME PROTEZIONE",
"394,ESTRATTORE FUMI RISC. INDIRETTO 2 - ALLARME PROTEZIONE",
"395,ESTRATTORE FUMI RISC. INDIRETTO 3 - ALLARME PROTEZIONE",
"396,ESTRATTORE FUMI RISC. INDIRETTO 4 - ALLARME PROTEZIONE",
"397,ESTRATTORE FUMI RISC. INDIRETTO 5 - ALLARME PROTEZIONE",
"398,ESTRATTORE FUMI RISC. INDIRETTO 6 - ALLARME PROTEZIONE",
"399,TAGLIERINA SINISTRA - FUORI POSIZIONE",
"400,TAGLIERINA DESTRA - FUORI POSIZIONE"
]
},
{
"description": "Alarm Word 25 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 25",
"index": 25,
"size": 2,
"messages": [
"401,ALLARME PROTEZIONE CILINDRO CONTRASTO TAGLIERINE",
"402,JBOX INGRESSO - TESSUTO INCROCIATO",
"403,JBOX USCITA - TESSUTO INCROCIATO",
"404,ALLARME DEVICE_NET STAZIONE ADDR.38 - JBOX INGRESSO",
"405,ALLARME DEVICE_NET STAZIONE ADDR.39 - JBOX USCITA",
"406,JBOX INGRESSO - ALLARME INVERTER",
"407,JBOX USCITA - ALLARME INVERTER",
"408,ALLARGA/CENTRATORE A/B SU IMBARRAGGIO - ALLARME PROTEZIONE",
"409,ALLARME TIMEOUT VITE CAMPO PARALLELO 11",
"410,ALLARME TIMEOUT VITE CAMPO PARALLELO 12",
"411,FRENO JBOX INGRESSO - ALLARME PROTEZIONE",
"412,FRENO JBOX USCITA - ALLARME PROTEZIONE",
"413,ALLARME PROTEZIONE FRENO CAMPO CONICO SINISTRO",
"414,ALLARME PROTEZIONE FRENO CAMPO CONICO DESTRO",
"415,VERIFICA PRESSOSTATO 1 FALLITA",
"416,VERIFICA PRESSOSTATO 2 FALLITA"
]
},
{
"description": "Alarm Word 26 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 26",
"index": 26,
"size": 2,
"messages": [
"417,ALLARME TERMOSTATO INTERNO QUADRO",
"418,ALLARME PROTEZIONE RECUPERO CALORE - GRUPPO 1 POMPA 2",
"419,ALLARME PROTEZIONE RECUPERO CALORE - GRUPPO 2 POMPA 2",
"420,PROTEZIONE RIBALTABILE INGRESSO",
"421,FUNE EMERGENZA INGRESSO",
"422,PARATIA SCORREVOLE INGRESSO SINISTRA",
"423,PARATIA SCORREVOLE INGRESSO DESTRA",
"424,CANCELLO SINISTRO ENTRATA ANTERIORE",
"425,CANCELLO SINISTRO ENTRATA POSTERIORE",
"426,CANCELLO DESTRO ENTRATA ANTERIORE",
"427,CANCELLO DESTRO ENTRATA POSTERIORE",
"428,CANCELLO SINISTRO USCITA",
"429,CANCELLO DESTRO USCITA",
"430,TENSIONATORE FUNE EMERGENZA SINISTRA ZONA FORNO",
"431,TENSIONATORE FUNE EMERGENZA DESTRA ZONA FORNO",
"432,FUNE EMERGENZA SINISTRA ZONA FORNO"
]
},
{
"description": "Alarm Word 27 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 27",
"index": 27,
"size": 2,
"messages": [
"433,FUNE EMERGENZA DESTRA ZONA FORNO",
"434,ALLARME FEEDBACK SCARICO ARIA ENTRATA MACCHINA (1)",
"435,ALLARME FEEDBACK SCARICO ARIA ENTRATA MACCHINA (2)",
"436,ALLARME FEEDBACK SCARICO ARIA USCITA MACCHINA (1)",
"437,ALLARME FEEDBACK SCARICO ARIA USCITA MACCHINA (2)",
"438,ALLARME FEEDBACK EMERGENZA GENERALE DA SCARICO ARIA",
"439,BYPASS SPORTELLI ARMADIO ATTIVO",
"440,TIMEOUT ENCODER CAMPO CONICO SINISTRO",
"441,TIMEOUT ENCODER CAMPO CONICO DESTRO",
"442,ALLARME BALLERINO ALTO SPREMITORE 1",
"443,ALLARME BALLERINO ALTO SPREMITORE 2",
"444,",
"445,",
"446,",
"447,",
"448,"
]
},
{
"description": "Alarm Word 28 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 28",
"index": 28,
"size": 2,
"messages": [
"449,",
"450,",
"451,",
"452,",
"453,",
"454,",
"455,",
"456,",
"457,",
"458,",
"459,",
"460,ALLARME PROTEZIONE BARRE ANTISTATICHE",
"461,ALLARME PROTEZIONE VENTILAZIONE INTERNO QUADRO",
"462,BORDO SENSIBILE ",
"463,FALDAROTOLATORE_SICUREZZA SX/DX ",
"464,FALDAROTOLATORE_EMERGENZA TESSUTO "
]
},
{
"description": "Alarm Word 29 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 29",
"index": 29,
"size": 2,
"messages": [
"465,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.1",
"466,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.2",
"467,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.3",
"468,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.4",
"469,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.5",
"470,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.6",
"471,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.7",
"472,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.8",
"473,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.9",
"474,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.10",
"475,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.11",
"476,ALLARME DEPRESSIONE RISCALDAMENTO INDIRETTO BR.12",
"477,MALFUNZIONAMNETO PRESSOSTATO ESTRATTORE FUMI 1/2",
"478,MALFUNZIONAMNETO PRESSOSTATO ESTRATTORE FUMI 3/4",
"479,MALFUNZIONAMNETO PRESSOSTATO ESTRATTORE FUMI 5/6",
"480,MALFUNZIONAMNETO PRESSOSTATO ESTRATTORE FUMI 7/8"
]
},
{
"description": "Alarm Word 30 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 30",
"index": 30,
"size": 2,
"messages": [
"481,MALFUNZIONAMNETO PRESSOSTATO ESTRATTORE FUMI 9/10",
"482,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 1",
"483,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 2",
"484,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 3",
"485,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 4",
"486,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 5",
"487,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 6",
"488,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 7",
"489,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 8",
"490,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 9",
"491,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 10",
"492,TRASDUTTORE PRESSIONE BR 1 INTERROTTO",
"493,TRASDUTTORE PRESSIONE BR 2 INTERROTTO",
"494,TRASDUTTORE PRESSIONE BR 3 INTERROTTO",
"495,TRASDUTTORE PRESSIONE BR 4 INTERROTTO",
"496,TRASDUTTORE PRESSIONE BR 5 INTERROTTO"
]
},
{
"description": "Alarm Word 31 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 31",
"index": 31,
"size": 2,
"messages": [
"497,TRASDUTTORE PRESSIONE BR 6 INTERROTTO",
"498,TRASDUTTORE PRESSIONE BR 7 INTERROTTO",
"499,TRASDUTTORE PRESSIONE BR 8 INTERROTTO",
"500,TRASDUTTORE PRESSIONE BR 9 INTERROTTO",
"501,TRASDUTTORE PRESSIONE BR 10 INTERROTTO",
"502,TRASDUTTORE PRESSIONE BR 11 INTERROTTO",
"503,TRASDUTTORE PRESSIONE BR 12 INTERROTTO",
"504,ERRORE TRASDUTTORE DI PRESSIONE RC1",
"505,ERRORE TRASDUTTORE DI PRESSIONE RC2",
"506,ALLARME INVERTER RIPRISTINO PRESSIONE GRUPPO 1 RC",
"507,ALLARME INVERTER RIPRISTINO PRESSIONE GRUPPO 2 RC",
"508,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 11",
"509,MALFUNZIONAMENTO PRESSOSTATO SICUREZZA BRUCIATORE 12",
"510,ALLARME PRESSOSTATO TAGLIERINE",
"511,BALLERINO ALTO - SROTOLATORE - ALLARME",
"512,EMERGENZA DA LINEA ENTRATA RAMOSA"
]
},
{
"description": "Alarm Word 32 ",
"tipoMem": "Byte",
"memAddr": "Alarm Word 32",
"index": 32,
"size": 2,
"messages": [
"513,LINEA ENTRATA RAMOSA NON PRONTA",
"514,EMERGENZA DA LINEA USCITA RAMOSA",
"515,LINEA USCITA RAMOSA NON PRONTA",
"516,TAGLIERINA CENTRALE FUORI POSIZIONE",
"517,TIRACIMOSSE NON PRONTO",
"518,JBOX INGRESSO IN EMERGENZA",
"519,JBOX INGRESSO NON PRONTO",
"520,JBOX USCITA IN EMERGENZA",
"521,JBOX USCITA NON PRONTO",
"522,ALLARME D-NET 41 RISCALDAMENTO INDIRETTO",
"523,SPAZZOLATRICE IN EMERGENZA",
"524,SPAZZOLATRICE NON PRONTA",
"525,ALLARME FUNE DI SICUREZZA USCITA STACCAPEZZA",
"526,ALLARME FUNE DI SICUREZZA USCITA FALDAROTOLATORE",
"527,ALLARME FUNE DI SICUREZZA CAMPO CONICO SINISTRO",
"528,ALLARME FUNE DI SICUREZZA CAMPO CONICO DESTRO"
]
}
]
+84
View File
@@ -0,0 +1,84 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
; VALVITAL 2024
VENDOR=FFG
MODEL=CROSSFLEX A1600
[CNC]
; FANUC!
IP=192.168.214.100
PORT=9000
GETPRGNAME=true
[SERVER]
MPIP=192.168.214.4
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Green 11.4 | Red: Y11.7 | Yellow: Y11.6 (bianco, eventualmente in lampeggio) | Emerg: X8.4 (negata)|
;BIT0=CONN
BIT1=Y11.4
BIT2=PZCOUNT.PAR.6711
BIT3=Y11.7
BIT4=Y11.6
BIT5=!X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
;PZCOUNT_MODE=STD.MACRO.930
;PZGTOT_MODE=STD.MACRO.929
PZCOUNT_MODE=STD.MACRO.929
PZGTOT_MODE=STD.PAR.6712
PZREQ_MODE=STD.MACRO.964
ENABLE_PZ_REQ=TRUE
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; conf cablata set Art/Commessa
SET_NUM_ART=STD.MACRO.966
SET_NUM_COM=STD.MACRO.965
;indica se il numero articolo sia semplicemente il trim dei caratteri alfabetici (chiama comunque server...)
NUM_ART_CHR_TRIM=TRUE
; conf parametri memoria READ/WRITE
PARAM_CONF=VL27.json
DISABLE_SEND_WDST=TRUE
[BRANCH]
NAME=master
+103
View File
@@ -0,0 +1,103 @@
{
"mMapWrite": {
"setArt": {
"name": "setArt",
"description": "Articolo",
"memAddr": "NONE.01",
"tipoMem": "String",
"index": 0,
"size": 20,
"displOrdinal": 1
},
"setArtNum": {
"name": "setArtNum",
"description": "# Num Articolo",
"memAddr": "MACRO.966",
"tipoMem": "Int",
"index": 966,
"size": 4,
"displOrdinal": 1
},
"setComm": {
"name": "setComm",
"description": "Commessa",
"memAddr": "NONE.02",
"tipoMem": "String",
"index": 0,
"size": 20,
"displOrdinal": 2
},
"setCommNum": {
"name": "setCommNum",
"description": "# NumCommessa",
"memAddr": "MACRO.965",
"tipoMem": "Int",
"index": 965,
"size": 4,
"displOrdinal": 2
},
"setPzComm": {
"name": "setPzComm",
"description": "Qta Richiesta",
"memAddr": "MACRO.964",
"tipoMem": "Int",
"index": 964,
"size": 4,
"displOrdinal": 3
}
},
"mMapRead": {
"PZ_GTOT": {
"name": "PZ_GTOT",
"description": "Contatore GTot",
"memAddr": "",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1,
"displOrdinal": 7
},
"PZ_COUNT": {
"name": "PZ_COUNT",
"description": "Contatore",
"memAddr": "",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1,
"displOrdinal": 8
},
"PROG": {
"name": "PROG",
"description": "Programma",
"memAddr": "",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1,
"displOrdinal": 9
},
"PzCntFree": {
"name": "PzCntFree",
"description": "Contatore",
"memAddr": "MACRO.930",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1,
"displOrdinal": 8
}
},
"mMapWriteLink": {
"setArt": "setArtNum",
"setComm": "setCommNum"
}
}
@@ -0,0 +1,8 @@
<linker>
<assembly fullname="System.Diagnostics.DiagnosticSource">
<type fullname="System.Diagnostics.Metrics.MetricsEventSource">
<!-- Used by System.Private.CoreLib via reflection to init the EventSource -->
<method name="GetInstance" />
</type>
</assembly>
</linker>
+241
View File
@@ -0,0 +1,241 @@
<?xml version="1.0" encoding="utf-8"?>
<Project ToolsVersion="15.0" xmlns="http://schemas.microsoft.com/developer/msbuild/2003">
<Import Project="$(MSBuildExtensionsPath)\$(MSBuildToolsVersion)\Microsoft.Common.props" Condition="Exists('$(MSBuildExtensionsPath)\$(MSBuildToolsVersion)\Microsoft.Common.props')" />
<PropertyGroup>
<Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration>
<Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform>
<ProjectGuid>{4F59C1D0-6CAE-4B30-AA21-71126472187C}</ProjectGuid>
<OutputType>WinExe</OutputType>
<RootNamespace>IOB_WIN_FANUC</RootNamespace>
<AssemblyName>IOB-WIN-FANUC</AssemblyName>
<TargetFrameworkVersion>v4.6.2</TargetFrameworkVersion>
<FileAlignment>512</FileAlignment>
<AutoGenerateBindingRedirects>true</AutoGenerateBindingRedirects>
<Deterministic>true</Deterministic>
<NuGetPackageImportStamp>
</NuGetPackageImportStamp>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Debug|AnyCPU' ">
<PlatformTarget>AnyCPU</PlatformTarget>
<DebugSymbols>true</DebugSymbols>
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>DEBUG;TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">
<PlatformTarget>AnyCPU</PlatformTarget>
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
<ItemGroup>
<Reference Include="EgwProxy.MultiCncLib, Version=0.0.0.0, Culture=neutral, processorArchitecture=MSIL">
<HintPath>..\packages\EgwProxy.MultiCncLib.3.6.2207.1211\lib\EgwProxy.MultiCncLib.dll</HintPath>
</Reference>
<Reference Include="MapoSDK, Version=6.14.2411.518, Culture=neutral, processorArchitecture=MSIL">
<HintPath>..\packages\MapoSDK.6.14.2411.518\lib\MapoSDK.dll</HintPath>
</Reference>
<Reference Include="Microsoft.Bcl.AsyncInterfaces, Version=9.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\Microsoft.Bcl.AsyncInterfaces.9.0.0\lib\net462\Microsoft.Bcl.AsyncInterfaces.dll</HintPath>
</Reference>
<Reference Include="Microsoft.Extensions.DependencyInjection.Abstractions, Version=9.0.0.0, Culture=neutral, PublicKeyToken=adb9793829ddae60, processorArchitecture=MSIL">
<HintPath>..\packages\Microsoft.Extensions.DependencyInjection.Abstractions.9.0.0\lib\net462\Microsoft.Extensions.DependencyInjection.Abstractions.dll</HintPath>
</Reference>
<Reference Include="Microsoft.Extensions.Logging.Abstractions, Version=9.0.0.0, Culture=neutral, PublicKeyToken=adb9793829ddae60, processorArchitecture=MSIL">
<HintPath>..\packages\Microsoft.Extensions.Logging.Abstractions.9.0.0\lib\net462\Microsoft.Extensions.Logging.Abstractions.dll</HintPath>
</Reference>
<Reference Include="Newtonsoft.Json, Version=13.0.0.0, Culture=neutral, PublicKeyToken=30ad4fe6b2a6aeed, processorArchitecture=MSIL">
<HintPath>..\packages\Newtonsoft.Json.13.0.3\lib\net45\Newtonsoft.Json.dll</HintPath>
</Reference>
<Reference Include="System" />
<Reference Include="System.Buffers, Version=4.0.4.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\System.Buffers.4.6.0\lib\net462\System.Buffers.dll</HintPath>
</Reference>
<Reference Include="System.Core" />
<Reference Include="System.Diagnostics.DiagnosticSource, Version=9.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\System.Diagnostics.DiagnosticSource.9.0.0\lib\net462\System.Diagnostics.DiagnosticSource.dll</HintPath>
</Reference>
<Reference Include="System.IO.Pipelines, Version=9.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\System.IO.Pipelines.9.0.0\lib\net462\System.IO.Pipelines.dll</HintPath>
</Reference>
<Reference Include="System.Memory, Version=4.0.2.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\System.Memory.4.6.0\lib\net462\System.Memory.dll</HintPath>
</Reference>
<Reference Include="System.Numerics" />
<Reference Include="System.Numerics.Vectors, Version=4.1.5.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\packages\System.Numerics.Vectors.4.6.0\lib\net462\System.Numerics.Vectors.dll</HintPath>
</Reference>
<Reference Include="System.Runtime.CompilerServices.Unsafe, Version=6.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\packages\System.Runtime.CompilerServices.Unsafe.6.1.0\lib\net462\System.Runtime.CompilerServices.Unsafe.dll</HintPath>
</Reference>
<Reference Include="System.Threading.Channels, Version=9.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\System.Threading.Channels.9.0.0\lib\net462\System.Threading.Channels.dll</HintPath>
</Reference>
<Reference Include="System.Threading.Tasks.Extensions, Version=4.2.1.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\System.Threading.Tasks.Extensions.4.6.0\lib\net462\System.Threading.Tasks.Extensions.dll</HintPath>
</Reference>
<Reference Include="System.Xml.Linq" />
<Reference Include="System.Data.DataSetExtensions" />
<Reference Include="Microsoft.CSharp" />
<Reference Include="System.Data" />
<Reference Include="System.Deployment" />
<Reference Include="System.Drawing" />
<Reference Include="System.Net.Http" />
<Reference Include="System.Windows.Forms" />
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="..\VersGen\VersGen.cs">
<Link>VersGen.cs</Link>
</Compile>
<Compile Include="AdapterFormNext.cs">
<SubType>Form</SubType>
</Compile>
<Compile Include="Iob\Fanuc.cs" />
<Compile Include="MainFormNext.cs">
<SubType>Form</SubType>
</Compile>
<Compile Include="memAreaFanuc.cs" />
<Compile Include="Program.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
<Content Include="ILLink\ILLink.Descriptors.LibraryBuild.xml" />
<Content Include="Resources\STEAM-IOB-WIN.xml">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<Content Include="Resources\SteamWare.ico">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<EmbeddedResource Include="Properties\Resources.resx">
<Generator>ResXFileCodeGenerator</Generator>
<LastGenOutput>Resources.Designer.cs</LastGenOutput>
<SubType>Designer</SubType>
</EmbeddedResource>
<Compile Include="Iob\GenericNext.cs" />
<Compile Include="Properties\Resources.Designer.cs">
<AutoGen>True</AutoGen>
<DependentUpon>Resources.resx</DependentUpon>
</Compile>
<None Include="App.Debug.config">
<DependentUpon>App.config</DependentUpon>
<CopyToOutputDirectory>PreserveNewest</CopyToOutputDirectory>
</None>
<None Include="App.Release.config">
<DependentUpon>App.config</DependentUpon>
<CopyToOutputDirectory>PreserveNewest</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\3001.ini" />
<None Include="DATA\CONF\3002.ini" />
<None Include="DATA\CONF\3003.ini" />
<None Include="DATA\CONF\3004.ini" />
<None Include="DATA\CONF\3005.ini" />
<None Include="DATA\CONF\3006.ini" />
<None Include="DATA\CONF\3007.ini" />
<None Include="DATA\CONF\3012.ini" />
<None Include="DATA\CONF\3015.ini" />
<None Include="DATA\CONF\3021.ini" />
<None Include="DATA\CONF\3025.ini" />
<None Include="DATA\CONF\3028.ini" />
<None Include="DATA\CONF\3028.json" />
<None Include="DATA\CONF\FOV002.ini" />
<None Include="DATA\CONF\FOV005.ini" />
<None Include="DATA\CONF\FOV006.ini" />
<None Include="DATA\CONF\FOV008.ini" />
<None Include="DATA\CONF\FOV011.ini" />
<None Include="DATA\CONF\FOV090.ini" />
<None Include="DATA\CONF\FOV098.ini" />
<None Include="DATA\CONF\FOV099.ini" />
<None Include="DATA\CONF\GT529.ini" />
<None Include="DATA\CONF\GT555.ini" />
<None Include="DATA\CONF\GT575.ini" />
<None Include="DATA\CONF\GT578.ini" />
<None Include="DATA\CONF\GT579.ini" />
<None Include="DATA\CONF\GT613.ini" />
<None Include="DATA\CONF\GT653.ini" />
<None Include="DATA\CONF\GT658.ini" />
<None Include="DATA\CONF\GT673.ini" />
<None Include="DATA\CONF\L014.ini" />
<None Include="DATA\CONF\L017.ini" />
<None Include="DATA\CONF\L018.ini" />
<None Include="DATA\CONF\L019.ini" />
<None Include="DATA\CONF\VL27.ini" />
<None Include="DATA\CONF\VL27.json" />
<None Include="NLog.config">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="packages.config" />
<None Include="postBuildTgt.bat" />
<None Include="DATA\CONF\IOB.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\MAIN.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\SIMUL_01.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\SIMUL_01.json">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\SIMUL_01_alarm.json">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\SIMUL_01_WD.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="Properties\Settings.settings">
<Generator>SettingsSingleFileGenerator</Generator>
<LastGenOutput>Settings.Designer.cs</LastGenOutput>
</None>
<Compile Include="Properties\Settings.Designer.cs">
<AutoGen>True</AutoGen>
<DependentUpon>Settings.settings</DependentUpon>
<DesignTimeSharedInput>True</DesignTimeSharedInput>
</Compile>
<Content Include="Resources\Start-IOB-WIN.bat">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<None Include="setupTgt.bat" />
<None Include="temp\.placeholder">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
</ItemGroup>
<ItemGroup>
<None Include="App.config">
<SubType>Designer</SubType>
<CopyToOutputDirectory>PreserveNewest</CopyToOutputDirectory>
</None>
</ItemGroup>
<ItemGroup>
<Content Include="logs\.placeholder.txt">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<Content Include="Resources\ChangeLog.html">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<Content Include="Resources\Circuit.ico" />
<Content Include="Resources\logoSteamware.png">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<Content Include="Resources\manifest.xml">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</Content>
<Content Include="Resources\Net.ico" />
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\IOB-UT-NEXT\IOB-UT-NEXT.csproj">
<Project>{90512e12-29fc-460d-94cc-648c2a072dbd}</Project>
<Name>IOB-UT-NEXT</Name>
</ProjectReference>
<ProjectReference Include="..\IOB-WIN-FORM\IOB-WIN-FORM.csproj">
<Project>{9ba331bb-9bf1-40e0-ac03-74b43d73a097}</Project>
<Name>IOB-WIN-FORM</Name>
</ProjectReference>
</ItemGroup>
<Import Project="$(MSBuildToolsPath)\Microsoft.CSharp.targets" />
</Project>
File diff suppressed because it is too large Load Diff
+13
View File
@@ -0,0 +1,13 @@
using IOB_UT_NEXT;
namespace IOB_WIN_FANUC.Iob
{
public class GenericNext : IOB_WIN_FORM.Iob.Generic
{
public GenericNext(AdapterFormNext caller, IobConfiguration IOBConf): base((IOB_WIN_FORM.AdapterForm)caller, IOBConf)
{
}
}
}
+40
View File
@@ -0,0 +1,40 @@
using IOB_UT_NEXT;
using IOB_WIN_FANUC.Iob;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace IOB_WIN_FANUC
{
public class MainFormNext : IOB_WIN_FORM.MainForm
{
/// <summary>
/// Avvio MainForm
/// </summary>
/// <param name="args"></param>
public MainFormNext(string[] args) : base(args)
{
}
/// <summary>
/// Apre la finestra child con conf
/// </summary>
protected override void openChild(string IOB)
{
if (IOB == null)
{
throw new ArgumentNullException(nameof(IOB));
}
AdapterFormNext child = new AdapterFormNext(IOB);
child.MdiParent = this;
child.Text = IOB;
child.Show();
child.Shown += Child_Shown;
child.FormClosed += Child_FormClosed;
}
}
}
+39
View File
@@ -0,0 +1,39 @@
<?xml version="1.0" encoding="utf-8" ?>
<nlog xmlns="http://www.nlog-project.org/schemas/NLog.xsd"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.nlog-project.org/schemas/NLog.xsd NLog.xsd"
autoReload="true"
throwExceptions="false"
internalLogLevel="Off" internalLogFile="c:\temp\nlog-internal.log">
<variable name="logDir" value="${basedir}/logs"/>
<targets>
<target xsi:type="File"
name="f_base"
fileName="${logDir}/${var:codIOB:default=0000}/${shortdate}.log"
layout="${longdate} [${uppercase:${level}}] ${logger:shortName=true} | ${message}"
archiveFileName="${logDir}/${var:codIOB:default=0000}/${shortdate}.{###}.log"
archiveNumbering="Sequence"
archiveAboveSize="10240000"
maxArchiveFiles="90"
enableArchiveFileCompression="false"
keepFileOpen="false"
/>
<target xsi:type="File"
name="f_error"
fileName="${logDir}/${var:codIOB:default=0000}/${shortdate}_err.log"
layout="${longdate} [${uppercase:${level}}] ${logger:shortName=true} | ${message}${newline}${exception:format=tostring}"
archiveFileName="${logDir}/${var:codIOB:default=0000}/${shortdate}_err.{###}.log"
archiveNumbering="Sequence"
archiveAboveSize="10240000"
maxArchiveFiles="90"
enableArchiveFileCompression="false"
keepFileOpen="false"
/>
</targets>
<rules>
<!-- Logging Levels (Trace, Debug, Info, Warn, Error, Fatal)-->
<logger name="*" minlevel="Trace" maxlevel="Warn" final="true" writeTo="f_base" />
<logger name="*" minlevel="Error" writeTo="f_error" />
</rules>
</nlog>
+24
View File
@@ -0,0 +1,24 @@
using System;
using System.Windows.Forms;
namespace IOB_WIN_FANUC
{
internal static class Program
{
#region Private Methods
/// <summary>
/// Punto di ingresso principale dell'applicazione.
/// <paramref name="args">Parametri di avvio</paramref>
/// </summary>
[STAThread]
private static void Main(string[] args)
{
Application.EnableVisualStyles();
Application.SetCompatibleTextRenderingDefault(false);
Application.Run(new MainFormNext(args));
}
#endregion Private Methods
}
}
+21
View File
@@ -0,0 +1,21 @@
using System.Reflection;
using System.Runtime.CompilerServices;
using System.Runtime.InteropServices;
// General Information about an assembly is controlled through the following
// set of attributes. Change these attribute values to modify the information
// associated with an assembly.
[assembly: AssemblyTitle("IOB-WIN-FANUC")]
[assembly: AssemblyDescription("")]
[assembly: AssemblyConfiguration("")]
[assembly: AssemblyProduct("IOB-WIN-FANUC")]
[assembly: AssemblyTrademark("")]
[assembly: AssemblyCulture("")]
// Setting ComVisible to false makes the types in this assembly not visible
// to COM components. If you need to access a type in this assembly from
// COM, set the ComVisible attribute to true on that type.
[assembly: ComVisible(false)]
// The following GUID is for the ID of the typelib if this project is exposed to COM
[assembly: Guid("4f59c1d0-6cae-4b30-aa21-71126472187c")]
+71
View File
@@ -0,0 +1,71 @@
//------------------------------------------------------------------------------
// <auto-generated>
// This code was generated by a tool.
// Runtime Version:4.0.30319.42000
//
// Changes to this file may cause incorrect behavior and will be lost if
// the code is regenerated.
// </auto-generated>
//------------------------------------------------------------------------------
namespace IOB_WIN_FANUC.Properties
{
/// <summary>
/// A strongly-typed resource class, for looking up localized strings, etc.
/// </summary>
// This class was auto-generated by the StronglyTypedResourceBuilder
// class via a tool like ResGen or Visual Studio.
// To add or remove a member, edit your .ResX file then rerun ResGen
// with the /str option, or rebuild your VS project.
[global::System.CodeDom.Compiler.GeneratedCodeAttribute("System.Resources.Tools.StronglyTypedResourceBuilder", "4.0.0.0")]
[global::System.Diagnostics.DebuggerNonUserCodeAttribute()]
[global::System.Runtime.CompilerServices.CompilerGeneratedAttribute()]
internal class Resources
{
private static global::System.Resources.ResourceManager resourceMan;
private static global::System.Globalization.CultureInfo resourceCulture;
[global::System.Diagnostics.CodeAnalysis.SuppressMessageAttribute("Microsoft.Performance", "CA1811:AvoidUncalledPrivateCode")]
internal Resources()
{
}
/// <summary>
/// Returns the cached ResourceManager instance used by this class.
/// </summary>
[global::System.ComponentModel.EditorBrowsableAttribute(global::System.ComponentModel.EditorBrowsableState.Advanced)]
internal static global::System.Resources.ResourceManager ResourceManager
{
get
{
if ((resourceMan == null))
{
global::System.Resources.ResourceManager temp = new global::System.Resources.ResourceManager("IOB_WIN_FANUC.Properties.Resources", typeof(Resources).Assembly);
resourceMan = temp;
}
return resourceMan;
}
}
/// <summary>
/// Overrides the current thread's CurrentUICulture property for all
/// resource lookups using this strongly typed resource class.
/// </summary>
[global::System.ComponentModel.EditorBrowsableAttribute(global::System.ComponentModel.EditorBrowsableState.Advanced)]
internal static global::System.Globalization.CultureInfo Culture
{
get
{
return resourceCulture;
}
set
{
resourceCulture = value;
}
}
}
}
+117
View File
@@ -0,0 +1,117 @@
<?xml version="1.0" encoding="utf-8"?>
<root>
<!--
Microsoft ResX Schema
Version 2.0
The primary goals of this format is to allow a simple XML format
that is mostly human readable. The generation and parsing of the
various data types are done through the TypeConverter classes
associated with the data types.
Example:
... ado.net/XML headers & schema ...
<resheader name="resmimetype">text/microsoft-resx</resheader>
<resheader name="version">2.0</resheader>
<resheader name="reader">System.Resources.ResXResourceReader, System.Windows.Forms, ...</resheader>
<resheader name="writer">System.Resources.ResXResourceWriter, System.Windows.Forms, ...</resheader>
<data name="Name1"><value>this is my long string</value><comment>this is a comment</comment></data>
<data name="Color1" type="System.Drawing.Color, System.Drawing">Blue</data>
<data name="Bitmap1" mimetype="application/x-microsoft.net.object.binary.base64">
<value>[base64 mime encoded serialized .NET Framework object]</value>
</data>
<data name="Icon1" type="System.Drawing.Icon, System.Drawing" mimetype="application/x-microsoft.net.object.bytearray.base64">
<value>[base64 mime encoded string representing a byte array form of the .NET Framework object]</value>
<comment>This is a comment</comment>
</data>
There are any number of "resheader" rows that contain simple
name/value pairs.
Each data row contains a name, and value. The row also contains a
type or mimetype. Type corresponds to a .NET class that support
text/value conversion through the TypeConverter architecture.
Classes that don't support this are serialized and stored with the
mimetype set.
The mimetype is used for serialized objects, and tells the
ResXResourceReader how to depersist the object. This is currently not
extensible. For a given mimetype the value must be set accordingly:
Note - application/x-microsoft.net.object.binary.base64 is the format
that the ResXResourceWriter will generate, however the reader can
read any of the formats listed below.
mimetype: application/x-microsoft.net.object.binary.base64
value : The object must be serialized with
: System.Serialization.Formatters.Binary.BinaryFormatter
: and then encoded with base64 encoding.
mimetype: application/x-microsoft.net.object.soap.base64
value : The object must be serialized with
: System.Runtime.Serialization.Formatters.Soap.SoapFormatter
: and then encoded with base64 encoding.
mimetype: application/x-microsoft.net.object.bytearray.base64
value : The object must be serialized into a byte array
: using a System.ComponentModel.TypeConverter
: and then encoded with base64 encoding.
-->
<xsd:schema id="root" xmlns="" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:msdata="urn:schemas-microsoft-com:xml-msdata">
<xsd:element name="root" msdata:IsDataSet="true">
<xsd:complexType>
<xsd:choice maxOccurs="unbounded">
<xsd:element name="metadata">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" />
<xsd:attribute name="type" type="xsd:string" />
<xsd:attribute name="mimetype" type="xsd:string" />
</xsd:complexType>
</xsd:element>
<xsd:element name="assembly">
<xsd:complexType>
<xsd:attribute name="alias" type="xsd:string" />
<xsd:attribute name="name" type="xsd:string" />
</xsd:complexType>
</xsd:element>
<xsd:element name="data">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
<xsd:element name="comment" type="xsd:string" minOccurs="0" msdata:Ordinal="2" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" msdata:Ordinal="1" />
<xsd:attribute name="type" type="xsd:string" msdata:Ordinal="3" />
<xsd:attribute name="mimetype" type="xsd:string" msdata:Ordinal="4" />
</xsd:complexType>
</xsd:element>
<xsd:element name="resheader">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" use="required" />
</xsd:complexType>
</xsd:element>
</xsd:choice>
</xsd:complexType>
</xsd:element>
</xsd:schema>
<resheader name="resmimetype">
<value>text/microsoft-resx</value>
</resheader>
<resheader name="version">
<value>2.0</value>
</resheader>
<resheader name="reader">
<value>System.Resources.ResXResourceReader, System.Windows.Forms, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
</resheader>
<resheader name="writer">
<value>System.Resources.ResXResourceWriter, System.Windows.Forms, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
</resheader>
</root>
+30
View File
@@ -0,0 +1,30 @@
//------------------------------------------------------------------------------
// <auto-generated>
// This code was generated by a tool.
// Runtime Version:4.0.30319.42000
//
// Changes to this file may cause incorrect behavior and will be lost if
// the code is regenerated.
// </auto-generated>
//------------------------------------------------------------------------------
namespace IOB_WIN_FANUC.Properties
{
[global::System.Runtime.CompilerServices.CompilerGeneratedAttribute()]
[global::System.CodeDom.Compiler.GeneratedCodeAttribute("Microsoft.VisualStudio.Editors.SettingsDesigner.SettingsSingleFileGenerator", "11.0.0.0")]
internal sealed partial class Settings : global::System.Configuration.ApplicationSettingsBase
{
private static Settings defaultInstance = ((Settings)(global::System.Configuration.ApplicationSettingsBase.Synchronized(new Settings())));
public static Settings Default
{
get
{
return defaultInstance;
}
}
}
}
@@ -0,0 +1,7 @@
<?xml version='1.0' encoding='utf-8'?>
<SettingsFile xmlns="http://schemas.microsoft.com/VisualStudio/2004/01/settings" CurrentProfile="(Default)">
<Profiles>
<Profile Name="(Default)" />
</Profiles>
<Settings />
</SettingsFile>
+120
View File
@@ -0,0 +1,120 @@
<body>
<h3>MAPO-IOB-WIN</h3>
<b>v: {{CURRENT-REL}}</b>
<br />
<i>Acquisitore MAPO-IOB per sistemi Windows</i>
<br />
Note di rilascio:
<ul>
<li>
<b>v.3.1.* &rarr; v.3.2.*</b>
<ul>
<li>Nuovi simulatori con gestione emergenza</li>
<li>Fix gestione invio dati Redis</li>
<li>Implementazione IOB Eurom63</li>
</ul>
</li>
<li>
<b>v.2.6.* &rarr; v.3.0.*</b>
<ul>
<li>revisione sistema metodi invio in blocco</li>
<li>Gestione invio contapezzi in step > 1</li>
<li>Gestione eventi in blocco (indipendente e prioritario su EvBlock)</li>
<li>Gestione limite eventi memorizzabili</li>
<li>Integrazione REDIS</li>
<li>Integrazione IOB-MAN</li>
</ul>
</li>
<li>
<b>v.2.5.* &rarr; v.2.6.*</b>
<ul>
<li>revisione sistema timeout Ping</li>
<li>Gestione AutoODL in prod generale (non solo SIM)</li>
</ul>
</li>
<li>
<b>v.2.4.* &rarr; v.2.5.*</b>
<ul>
<li>Aggiunto adapter MTConnect</li>
<li>Ottimizzazione gestione SIEMENS</li>
</ul>
</li>
<li>
<b>v.2.3.* &rarr; v.2.4.*</b>
<ul>
<li>inserita gestione conf json x Flog acquisiti</li>
<li>gestione invio Json blocchi dati FLog</li>
<li>ottimizzazioni varie adapter Siemens</li>
<li>ottimizzazione processo svuotamento code</li>
<li>riduzione interferenza e interblocchi in fase di PLC assente</li>
</ul>
</li>
<li>
<b>Ultime modifiche:</b>
<ul>{{LAST-CHANGES}}</ul>
</li>
<li>
<b>v.1.18.* &rarr; v.2.3.*</b>
<ul>
<li>inserimento WPS x acontrolli WebPage human readable</li>
<li>fix gestione task2exe</li>
<li>aggiunte varie versioni PLC siemens</li>
<li>aggiunto PLC WPS x generiche web pages</li>
<li>revisitazione LOG ODL e contapezzi</li>
<li>modifica pagina presentazione dati (master) x resize</li>
<li>Attivazione IOB SIMULATOR per test di carico (sostituito type DEMO)</li>
<li>Aggiunto simulatore macchine MULTI pallet</li>
<li>Ottimizzazione simulatore</li>
<li>Ottimizzazioni PLC Siemens x riavvio post disconnessione (es spegnimento notturno)</li>
<li>Ottimizzazione processo chiusura in update applicazione</li>
<li>Aggiunta simulazione spegnimento con WU/CD</li>
</ul>
</li>
<li>
<b>v.1.11.* &rarr; v.1.18.*</b>
<ul>
<li>Inserimento controller SIEMENS con S7+ library</li>
<li>Inserimento nuove letture FANUC x programmi</li>
<li>Inserimento nuove letture FANUC x SysEx (informazioni sistema)</li>
<li>Inserimento invio FluxLog x parametri estesi (es SysEx, ProgName,...)</li>
<li>FIX visualizzazione dati FluxLog e URL inviati</li>
<li>FIX MAIN program da FANUC (non il current)</li>
<li>Inserita modalita' DUMP memoria (iniziale full + periodica)</li>
<li>Inserimento gestione contapezzi standard/checkBit in IOB.cfg</li>
<li>Inserimento contapezzi da area memoria X</li>
<li>NUOVA Gestione rami cliente e URL di update</li>
<li>Gestione modi CNC</li>
<li>Lettura dari dinamycs FANUC (feed, speed)</li>
<li> aggiunta gestione aree G0..G30 (overrides?)</li>
<li>fix errore disconnessione FANUC (allo spegnimento dl CNC) e memoria valori persistente a 1</li>
<li>fix globali x gestione log IN / FLOG + ottimizzaizone check FANUC (PING)</li>
<li>ottimizzazione fasi di restart in caso di assenza del server (evita reinvii inutili e migliora tempo ripartenza invio)</li>
<li>review procedure controllo connessione x FANUC (es Tornos II)</li>
<li>non richeide più privilegi admin x fare update</li>
<li> gestione segnali inverted</li>
<li>completata gestione configurabilità parametrica segnali (Tornos, CMZ, Biglia)</li>
<li>revisitazione LOG x distinguere processi IOB</li>
</ul>
</li>
<li>
<b>v.0.1.* &rarr; v.0.10.*</b>
<ul>
<li>Testato in produzione x update ad avvio e su richiesta</li>
<li>Testato in produzione x lettura dati da Fanuc</li>
<li>Inizio deploy con copia file su area IIS</li>
<li>Prima versione con autoupdate</li>
<li>Test PrettyBin x spostamento dll</li>
<li>Base acquisitore FANUC</li>
<li>Sistema base sw controllo in tray</li>
</ul>
</li>
</ul>
<div>
<div style="float: left;">
<img src="logoSteamware.png" />
</div>
<div style="float: right;">
<a href="https://www.steamware.net/IOT" target="_blank">&copy; Steamware 2006-{{CURR-YEAR}}</a>
</div>
</div>
</body>
Binary file not shown.

After

Width:  |  Height:  |  Size: 160 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 102 KiB

Binary file not shown.
+15
View File
@@ -0,0 +1,15 @@
@ECHO OFF
SET EXEName=IOB-WIN.exe
SET EXEFullPath=C:\Steamware\IOB-WIN\IOB-WIN.exe
TASKLIST | FINDSTR /I "%EXEName%"
IF ERRORLEVEL 1 GOTO :StartIobWin
REM "Programma ancora in run, nessuna azione necessaria"
timeout /T 2
GOTO :EOF
:StartIobWin
START "" "%EXEFullPath%"
GOTO :EOF
Binary file not shown.

After

Width:  |  Height:  |  Size: 273 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 3.3 KiB

+7
View File
@@ -0,0 +1,7 @@
<?xml version="1.0" encoding="UTF-8"?>
<item>
<version>1.0.0.0</version>
<url>http://seriate.steamware.net:8083/SWS/MAPO/IOB-WIN/{{BRANCHNAME}}/MAPO-IOB-WIN.zip</url>
<changelog>http://seriate.steamware.net:8083/SWS/MAPO/IOB-WIN/{{BRANCHNAME}}/ChangeLog.html</changelog>
<mandatory>false</mandatory>
</item>
+68
View File
@@ -0,0 +1,68 @@
{
"metadata": [
{
"src": [
{
"files": [
"*.csproj"
],
"cwd": ".",
"exclude": [
"**/obj/**",
"**/bin/**",
"_site/**"
]
}
],
"dest": "obj/api"
}
],
"build": {
"content": [
{
"files": [
"api/**.yml"
],
"cwd": "obj"
},
{
"files": [
"api/*.md",
"articles/**.md",
"toc.yml",
"*.md"
],
"exclude": [
"obj/**",
"_site/**"
]
}
],
"resource": [
{
"files": [
"images/**"
],
"exclude": [
"obj/**",
"_site/**"
]
}
],
"overwrite": [
{
"files": [
"apidoc/**.md"
],
"exclude": [
"obj/**",
"_site/**"
]
}
],
"dest": "_site",
"template": [
"default"
]
}
}
+11
View File
@@ -0,0 +1,11 @@
# IOB-WIN-PING
Documentazione relativa all'applicativo IOB-WIN-PING
## Articles
Per maggiori dettagli, definizioni e demo funzionamento si rimanda alla sezione Articles
## Api
Per ogni dettaglio e riferimento alla libreria si rimanda alla sezione Api Documentation
Binary file not shown.
+1
View File
@@ -0,0 +1 @@

+138
View File
@@ -0,0 +1,138 @@
using EgwProxy.MultiCncLib.CNC;
namespace IOB_WIN_FANUC
{
/// <summary>
/// Definizione indirizzo memoria FANUC
/// </summary>
public class memAddressFanuc
{
#region Public Fields
/// <summary>
/// Posizione memoria
/// </summary>
public int mPos;
/// <summary>
/// Tipo memoria
/// </summary>
public FANUC.MemType mType;
/// <summary>
/// Tipo valore
/// </summary>
public string vType;
#endregion Public Fields
#region Public Constructors
/// <summary>
/// Inizializza da un formato stringa
/// </summary>
/// <param name="strFormat">Stringa TipoMem.Indice.DimMem (es D.1604.DW)</param>
public memAddressFanuc(string strFormat)
{
if (!string.IsNullOrEmpty(strFormat))
{
string[] memComp = strFormat.Split('.');
switch (memComp[0])
{
case "A":
mType = FANUC.MemType.A;
break;
case "C":
mType = FANUC.MemType.C;
break;
case "CM":
mType = FANUC.MemType.CM;
break;
case "D":
mType = FANUC.MemType.D;
break;
case "E":
mType = FANUC.MemType.E;
break;
case "F":
mType = FANUC.MemType.F;
break;
case "G":
mType = FANUC.MemType.G;
break;
case "K":
mType = FANUC.MemType.K;
break;
case "M":
mType = FANUC.MemType.M;
break;
case "N":
mType = FANUC.MemType.N;
break;
case "R":
mType = FANUC.MemType.R;
break;
case "T":
mType = FANUC.MemType.T;
break;
case "X":
mType = FANUC.MemType.X;
break;
case "Y":
mType = FANUC.MemType.Y;
break;
case "Z":
mType = FANUC.MemType.Z;
break;
default:
break;
}
int.TryParse(memComp[1], out mPos);
vType = memComp[2];
}
}
#endregion Public Constructors
}
/// <summary>
/// Definizione area memoria FANUC
/// </summary>
public class memAreaFanuc
{
#region Public Fields
/// <summary>
/// Nome area memoria
/// </summary>
public string areaName;
/// <summary>
/// Dimensione array memoria
/// </summary>
public int arraySize;
/// <summary>
/// Indice inizio array
/// </summary>
public int startIdx;
#endregion Public Fields
}
}
+23
View File
@@ -0,0 +1,23 @@
<?xml version="1.0" encoding="utf-8"?>
<packages>
<package id="EgwProxy.MultiCncLib" version="3.6.2207.1211" targetFramework="net462" />
<package id="MapoSDK" version="6.14.2411.518" targetFramework="net462" />
<package id="Microsoft.Bcl.AsyncInterfaces" version="9.0.0" targetFramework="net462" />
<package id="Microsoft.Extensions.DependencyInjection.Abstractions" version="9.0.0" targetFramework="net462" />
<package id="Microsoft.Extensions.Logging.Abstractions" version="9.0.0" targetFramework="net462" />
<package id="Microsoft.VisualStudio.SlowCheetah" version="4.0.50" targetFramework="net462" developmentDependency="true" />
<package id="Newtonsoft.Json" version="13.0.3" targetFramework="net462" />
<package id="NLog" version="5.3.4" targetFramework="net462" />
<package id="Pipelines.Sockets.Unofficial" version="2.2.8" targetFramework="net462" />
<package id="StackExchange.Redis" version="2.8.24" targetFramework="net462" />
<package id="System.Buffers" version="4.6.0" targetFramework="net462" />
<package id="System.Diagnostics.DiagnosticSource" version="9.0.0" targetFramework="net462" />
<package id="System.IO.Compression" version="4.3.0" targetFramework="net462" />
<package id="System.IO.Pipelines" version="9.0.0" targetFramework="net462" />
<package id="System.Memory" version="4.6.0" targetFramework="net462" />
<package id="System.Numerics.Vectors" version="4.6.0" targetFramework="net462" />
<package id="System.Runtime.CompilerServices.Unsafe" version="6.1.0" targetFramework="net462" />
<package id="System.Runtime.InteropServices.RuntimeInformation" version="4.3.0" targetFramework="net462" />
<package id="System.Threading.Channels" version="9.0.0" targetFramework="net462" />
<package id="System.Threading.Tasks.Extensions" version="4.6.0" targetFramework="net462" />
</packages>
+97
View File
@@ -0,0 +1,97 @@
@echo off
echo Inizio processing After Build: configurazione %1 , directory %2
RD /S /Q %2"\lib\ar"
RD /S /Q %2"\lib\cs"
RD /S /Q %2"\lib\da"
RD /S /Q %2"\lib\de"
RD /S /Q %2"\lib\es"
RD /S /Q %2"\lib\fr"
RD /S /Q %2"\lib\it"
RD /S /Q %2"\lib\ja-JP"
RD /S /Q %2"\lib\ko"
RD /S /Q %2"\lib\lv"
RD /S /Q %2"\lib\nl"
RD /S /Q %2"\lib\pl"
RD /S /Q %2"\lib\pt"
RD /S /Q %2"\lib\pt-BR"
RD /S /Q %2"\lib\ru"
RD /S /Q %2"\lib\sk"
RD /S /Q %2"\lib\sv"
RD /S /Q %2"\lib\th"
RD /S /Q %2"\lib\tr"
RD /S /Q %2"\lib\zh"
RD /S /Q %2"\lib\zh-TW"
MOVE /Y %2"ar" %2"lib\"
MOVE /Y %2"cs" %2"lib\"
MOVE /Y %2"da" %2"lib\"
MOVE /Y %2"de" %2"lib\"
MOVE /Y %2"es" %2"lib\"
MOVE /Y %2"fr" %2"lib\"
MOVE /Y %2"it" %2"lib\"
MOVE /Y %2"ja-JP" %2"lib\"
MOVE /Y %2"ko" %2"lib\"
MOVE /Y %2"lv" %2"lib\"
MOVE /Y %2"nl" %2"lib\"
MOVE /Y %2"pl" %2"lib\"
MOVE /Y %2"pt" %2"lib\"
MOVE /Y %2"pt-BR" %2"lib\"
MOVE /Y %2"ru" %2"lib\"
MOVE /Y %2"sk" %2"lib\"
MOVE /Y %2"sv" %2"lib\"
MOVE /Y %2"th" %2"lib\"
MOVE /Y %2"tr" %2"lib\"
MOVE /Y %2"zh" %2"lib\"
MOVE /Y %2"zh-TW" %2"lib\"
if %1 == "Release" goto ReleaseExec
if %1 == Release goto ReleaseExec
if %1 == "Debug" goto DebugExec
if %1 == Debug goto DebugExec
if %1 == "Remote_DEBUG" goto RemoteDebugExec
if %1 == Remote_DEBUG goto RemoteDebugExec
:ReleaseExec
echo Release processing...
del /S %2"*.pdb""
del /S %2"*.xml""
del /S %2"lib/*.pdb""
echo Release: eliminato pdb + xml!!!
goto END
:DebugExec
echo Debug processing...
goto END
:RemoteDebugExec
echo Remote_DEBUG processing, effettuo copia script verso server remoto (ROBOCOPY)
REM copia script verso server remoto
REM echo Debug remoto: effettuo robocopy sync (verificare remote per cliente)
REM FINASSI
REM ROBOCOPY %2 \\10.150.0.1\Steamware\IOB-WIN-WPS-DEB /MIR
REM Baglietto
REM ROBOCOPY %2 \\192.168.60.15\Steamware\IOB-WIN-WPS-DEB /MIR
REM GIACOVELLI LOCOROTONDO
REM ROBOCOPY %2 \\192.168.1.93\Steamware\IOB-WIN-WPS-DEB /MIR
REM IMI Remosa
REM ROBOCOPY %2 \\192.168.0.12\Steamware\IOB-WIN-WPS-DEB /MIR
REM IOB-WIN-SIM
REM ROBOCOPY %2 \\IOB-WIN-SIMULA\Steamware\IOB-WIN-WPS-DEB /MIR
REM IOBVPN4MACHINE
REM ROBOCOPY %2 \\10.51.90.5\Steamware\IOB-WIN-WPS-DEB /MIR
REM ROBOCOPY %2 \\10.51.90.5\Steamware\IOB-WIN-WPS-DEB /MIR /log:RobocopyTransfer.log
REM ROBOCOPY %2 Z:\IOB-WIN-WPS-DEB /MIR
REM ROBOCOPY %2 \\10.51.90.10\Steamware\IOB-WIN-WPS-DEB /MIR
ROBOCOPY %2 \\10.51.90.9\Steamware\IOB-WIN-WPS-DEB /MIR
goto END
:END
echo Fatto!
+25
View File
@@ -0,0 +1,25 @@
@echo off
echo Effettua setup dei file specifici per i vari ambienti pre build installer: verifica da nome configurazione %1
if %1 == "Release" goto Release
if %1 == "Debug" goto Debug
if %1 == "Remote_DEBUG" goto RemoteDebug
:Release
echo Release: nulla da copiare
goto END
:Debug
echo Debug: copia file ini x simulazione Debug
REM del %2"DATA\CONF\EsaKvara.ini"
REM copy %2"Resources\SCM\EsaKvara_SIM.ini" %2"DATA\CONF\EsaKvara.ini"
goto END
:RemoteDebug
echo RemoteDebug: nulla da copiare
goto END
:END
echo Fatto!
+1
View File
@@ -0,0 +1 @@

+6
View File
@@ -0,0 +1,6 @@
- name: Articles
href: articles/
- name: API Documentation
href: obj/api/
homepage: api/index.md
+3 -83
View File
@@ -59,10 +59,12 @@ namespace IOB_WIN_NEXT
btnStart.Enabled = true;
break;
#if false
case tipoAdapter.FANUC:
iobObj = new Iob.Fanuc(this, IOBConf);
btnStart.Enabled = true;
break;
break;
#endif
case tipoAdapter.FTP:
iobObj = new IobNet.Ftp(this, IOBConf);
@@ -112,88 +114,6 @@ namespace IOB_WIN_NEXT
btnStart.Enabled = true;
break;
#if false
case tipoAdapter.SIEMENS:
iobObj = new IobSiemens.Siemens(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_APROCHIM:
iobObj = new IobSiemens.SiemensAprochim(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_AT2001:
iobObj = new IobSiemens.SiemensAt2001(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_COMECA:
iobObj = new IobSiemens.SiemensComeca(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_COMUR:
iobObj = new IobSiemens.SiemensComur(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_COSMAP:
iobObj = new IobSiemens.SiemensCosmap(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_FAPE:
iobObj = new IobSiemens.SiemensFape(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_FAPE_2:
iobObj = new IobSiemens.SiemensFapeV2(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_INGENIA:
iobObj = new IobSiemens.SiemensIngenia(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_LASCO:
iobObj = new IobSiemens.SiemensLasco(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_NWSE:
iobObj = new IobSiemens.SiemensNWSE(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_PRESSOIL_CEI:
iobObj = new IobSiemens.SiemensPressoilCei(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_ROBOTSERVICE:
iobObj = new IobSiemens.SiemensRobotService(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_SAET:
iobObj = new IobSiemens.SiemensSaet(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_SIMEC:
iobObj = new IobSiemens.SiemensSimec(this, IOBConf);
btnStart.Enabled = true;
break;
case tipoAdapter.SIEMENS_TORRI:
iobObj = new IobSiemens.SiemensTorri(this, IOBConf);
btnStart.Enabled = true;
break;
#endif
case tipoAdapter.SOAP_GOMBA:
iobObj = new IobSoap.Gomba(this, IOBConf);
btnStart.Enabled = true;
-67
View File
@@ -1,67 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Macchina transfer COSMAP per Donati
CNCTYPE=SIEMENS_COSMAP
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=COSMAP
MODEL=02
[CNC]
IP=192.168.51.140
CPUTYPE=S7300
RACK=0
SLOT=2
[SERVER]
MPIP=http://192.168.51.79
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB6.DBB0
ADDR_WRITE=DB6.DBB0
SIZE_READ=224
SIZE_WRITE=204
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB6.DBDW208
DISABLE_PZCOUNT=FALSE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; gestione custom timer
timerIntMs=30
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione scrittura string/char[]: true = string
WRITE_PRE=FALSE
; conf parametri memoria READ/WRITE
PARAM_CONF=1032.json
[BRANCH]
NAME=master
-82
View File
@@ -1,82 +0,0 @@
{
"mMapWrite": {
"setProg": {
"name": "setProg",
"description": "Programma",
"tipoMem": "String",
"memAddr": "DB6.DBB50",
"index": 50,
"size": 50
},
"setComm": {
"name": "setComm",
"description": "Commessa",
"tipoMem": "String",
"memAddr": "DB6.DBB0",
"index": 0,
"size": 50
},
"setArt": {
"name": "setArt",
"description": "Articolo",
"tipoMem": "String",
"memAddr": "DB6.DBB100",
"index": 100,
"size": 50
},
"setPzComm": {
"name": "setPzComm",
"description": "Qty",
"memAddr": "DB30.DBB212",
"tipoMem": "DInt",
"index": 212,
"size": 4
}
},
"mMapRead": {
"TempoLav": {
"name": "TempoLav",
"description": "TempoLav ASSOLUTO",
"memAddr": "DB6.DBB220",
"tipoMem": "Int",
"index": 220,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 10
},
"CadenzaH": {
"name": "CadenzaH",
"description": "Pezzi Ora",
"memAddr": "DB6.DBB222",
"tipoMem": "Int",
"index": 222,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 10
},
"Contatore01": {
"name": "Contatore01",
"description": "Contapezzi 01",
"memAddr": "DB6.DBB200",
"tipoMem": "DInt",
"index": 200,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
},
"ContatoreParziale": {
"name": "ContatoreParziale",
"description": "Contapezzi MES DBB208",
"memAddr": "DB6.DBB208",
"tipoMem": "DInt",
"index": 208,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
}
}
}
-69
View File
@@ -1,69 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Macchina pulitrice RobotService x Donati
CNCTYPE=SIEMENS_ROBOTSERVICE
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=RobotService
MODEL=SMER12
[CNC]
IP=192.168.51.138
CPUTYPE=S71500
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.51.79
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB14.DBB0
SIZE_READ=10
SIZE_WRITE=517
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB15.DBDW2
DISABLE_PZCOUNT=FALSE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; gestione custom timer
timerIntMs=30
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione scrittura string/char[]: true = string / false = char[]
WRITE_PRE=TRUE
; gestione emergenza forzata (ignora valore letto, mette sempre ARMED)
EMERGENCY_BYPASS=true
; conf parametri memoria READ/WRITE
PARAM_CONF=1033.json
[BRANCH]
NAME=master
-52
View File
@@ -1,52 +0,0 @@
{
"mMapWrite": {
"setComm": {
"name": "setComm",
"description": "Commessa",
"tipoMem": "String",
"memAddr": "DB14.DBB0",
"index": 0,
"size": 50
},
"setArt": {
"name": "setArt",
"description": "Articolo",
"tipoMem": "String",
"memAddr": "DB14.DBB256",
"index": 256,
"size": 50
},
"setPzComm": {
"name": "setPzComm",
"description": "Qty",
"memAddr": "DB14.DBB512",
"tipoMem": "DInt",
"index": 512,
"size": 4
}
},
"mMapRead": {
"Contatore01": {
"name": "PezziFineCiclo",
"description": "Mancanti programmati",
"memAddr": "DB15.DBB6",
"tipoMem": "DInt",
"index": 6,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
},
"ContatoreParziale": {
"name": "ContaPezzi",
"description": "Contapezzi MES DBB2",
"memAddr": "DB15.DBB2",
"tipoMem": "DInt",
"index": 2,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
}
}
}
-69
View File
@@ -1,69 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Macchina pulitrice RobotService x Donati
CNCTYPE=SIEMENS_ROBOTSERVICE
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=RobotService
MODEL=SCAT06
[CNC]
IP=192.168.51.134
CPUTYPE=S71500
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.51.79
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB14.DBB0
SIZE_READ=10
SIZE_WRITE=517
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB15.DBDW2
DISABLE_PZCOUNT=FALSE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; gestione custom timer
timerIntMs=30
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione scrittura string/char[]: true = string / false = char[]
WRITE_PRE=TRUE
; gestione emergenza forzata (ignora valore letto, mette sempre ARMED)
EMERGENCY_BYPASS=true
; conf parametri memoria READ/WRITE
PARAM_CONF=1034.json
[BRANCH]
NAME=master
-52
View File
@@ -1,52 +0,0 @@
{
"mMapWrite": {
"setComm": {
"name": "setComm",
"description": "Commessa",
"tipoMem": "String",
"memAddr": "DB14.DBB0",
"index": 0,
"size": 50
},
"setArt": {
"name": "setArt",
"description": "Articolo",
"tipoMem": "String",
"memAddr": "DB14.DBB256",
"index": 256,
"size": 50
},
"setPzComm": {
"name": "setPzComm",
"description": "Qty",
"memAddr": "DB14.DBB512",
"tipoMem": "DInt",
"index": 512,
"size": 4
}
},
"mMapRead": {
"Contatore01": {
"name": "PezziFineCiclo",
"description": "Mancanti programmati",
"memAddr": "DB15.DBB6",
"tipoMem": "DInt",
"index": 6,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
},
"ContatoreParziale": {
"name": "ContaPezzi",
"description": "Contapezzi MES DBB2",
"memAddr": "DB15.DBB2",
"tipoMem": "DInt",
"index": 2,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
}
}
}
-69
View File
@@ -1,69 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Macchina pulitrice RobotService x Donati
CNCTYPE=SIEMENS_ROBOTSERVICE
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=RobotService
MODEL=SCAT05
[CNC]
IP=192.168.51.135
CPUTYPE=S71500
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.51.79
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB14.DBB0
SIZE_READ=10
SIZE_WRITE=517
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB15.DBDW2
DISABLE_PZCOUNT=FALSE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; gestione custom timer
timerIntMs=30
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione scrittura string/char[]: true = string / false = char[]
WRITE_PRE=TRUE
; gestione emergenza forzata (ignora valore letto, mette sempre ARMED)
EMERGENCY_BYPASS=true
; conf parametri memoria READ/WRITE
PARAM_CONF=1035.json
[BRANCH]
NAME=master
-52
View File
@@ -1,52 +0,0 @@
{
"mMapWrite": {
"setComm": {
"name": "setComm",
"description": "Commessa",
"tipoMem": "String",
"memAddr": "DB14.DBB0",
"index": 0,
"size": 50
},
"setArt": {
"name": "setArt",
"description": "Articolo",
"tipoMem": "String",
"memAddr": "DB14.DBB256",
"index": 256,
"size": 50
},
"setPzComm": {
"name": "setPzComm",
"description": "Qty",
"memAddr": "DB14.DBB512",
"tipoMem": "DInt",
"index": 512,
"size": 4
}
},
"mMapRead": {
"Contatore01": {
"name": "PezziFineCiclo",
"description": "Mancanti programmati",
"memAddr": "DB15.DBB6",
"tipoMem": "DInt",
"index": 6,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
},
"ContatoreParziale": {
"name": "ContaPezzi",
"description": "Contapezzi MES DBB2",
"memAddr": "DB15.DBB2",
"tipoMem": "DInt",
"index": 2,
"size": 4,
"func": "MAX",
"period": 60,
"factor": 1
}
}
}
-70
View File
@@ -1,70 +0,0 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=SIEMENS_TORRI
[MACHINE]
VENDOR=TORRI
MODEL=VUOMARD
[CNC]
; Siemens Torri (Vuomard)
IP=192.168.0.51
CPUTYPE=S7300
RACK=0
SLOT=2
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB700.DBB0
ADDR_WRITE=DB701.DBB0
SIZE_READ=52
SIZE_WRITE=138
;BIT0=CONN
BIT1=DB700.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB700.DBB3
BIT4=DB700.DBB4
BIT5=DB701.DBB4 ; bit ciclo in test == riscaldamento
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB700.DBW22
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
DISABLE_SEND_WDST=TRUE
ENABLE_DYN_DATA=TRUE
ENABLE_ALARM_LEGACY=FALSE
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
; conf aree allarme
ALARM_CONF=3010_alarm.json
[BRANCH]
NAME=develop
-169
View File
@@ -1,169 +0,0 @@
[
{
"description": "Alarm Word 1",
"tipoMem": "Byte",
"memAddr": "DB700.DBDW2",
"index": 2,
"size": 4,
"messages": [
"ALLARME 01",
"ALLARME 02",
"ALLARME 03",
"ALLARME 04",
"ALLARME 05",
"ALLARME 06",
"ALLARME 07",
"ALLARME 08",
"ALLARME 09",
"ALLARME 10",
"ALLARME 11",
"ALLARME 12",
"ALLARME 13",
"ALLARME 14",
"ALLARME 15",
"ALLARME 16",
"ALLARME 17",
"ALLARME 18",
"ALLARME 19",
"ALLARME 20",
"ALLARME 21",
"ALLARME 22",
"ALLARME 23",
"ALLARME 24",
"ALLARME 25",
"ALLARME 26",
"ALLARME 27",
"ALLARME 28",
"ALLARME 29",
"ALLARME 30",
"ALLARME 31",
"ALLARME 32"
]
},
{
"description": "Alarm Word 2",
"tipoMem": "Byte",
"memAddr": "DB700.DBDW6",
"index": 6,
"size": 4,
"messages": [
"ALLARME 33",
"ALLARME 34",
"ALLARME 35",
"ALLARME 36",
"ALLARME 37",
"ALLARME 38",
"ALLARME 39",
"ALLARME 40",
"ALLARME 41",
"ALLARME 42",
"ALLARME 43",
"ALLARME 44",
"ALLARME 45",
"ALLARME 46",
"ALLARME 47",
"ALLARME 48",
"ALLARME 49",
"ALLARME 50",
"ALLARME 51",
"ALLARME 52",
"ALLARME 53",
"ALLARME 54",
"ALLARME 55",
"ALLARME 56",
"ALLARME 57",
"ALLARME 58",
"ALLARME 59",
"ALLARME 60",
"ALLARME 61",
"ALLARME 62",
"ALLARME 63",
"ALLARME 64"
]
},
{
"description": "Alarm Word 3",
"tipoMem": "Byte",
"memAddr": "DB700.DBDW10",
"index": 10,
"size": 4,
"messages": [
"ALLARME 65",
"ALLARME 66",
"ALLARME 67",
"ALLARME 68",
"ALLARME 69",
"ALLARME 70",
"ALLARME 71",
"ALLARME 72",
"ALLARME 73",
"ALLARME 74",
"ALLARME 75",
"ALLARME 76",
"ALLARME 77",
"ALLARME 78",
"ALLARME 79",
"ALLARME 80",
"ALLARME 81",
"ALLARME 82",
"ALLARME 83",
"ALLARME 84",
"ALLARME 85",
"ALLARME 86",
"ALLARME 87",
"ALLARME 88",
"ALLARME 89",
"ALLARME 90",
"ALLARME 91",
"ALLARME 92",
"ALLARME 93",
"ALLARME 94",
"ALLARME 95",
"ALLARME 96"
]
},
{
"description": "Alarm Word 4",
"tipoMem": "Byte",
"memAddr": "DB700.DBDW14",
"index": 14,
"size": 4,
"messages": [
"ALLARME 97",
"ALLARME 98",
"ALLARME 99",
"ALLARME 100",
"ALLARME 101",
"ALLARME 102",
"ALLARME 103",
"ALLARME 104",
"ALLARME 105",
"ALLARME 106",
"ALLARME 107",
"ALLARME 108",
"ALLARME 109",
"ALLARME 110",
"ALLARME 111",
"ALLARME 112",
"ALLARME 113",
"ALLARME 114",
"ALLARME 115",
"ALLARME 116",
"ALLARME 117",
"ALLARME 118",
"ALLARME 119",
"ALLARME 120",
"ALLARME 121",
"ALLARME 122",
"ALLARME 123",
"ALLARME 124",
"ALLARME 125",
"ALLARME 126",
"ALLARME 127",
"ALLARME 128"
]
}
]
-66
View File
@@ -1,66 +0,0 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=SIEMENS_TORRI
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=TORRI
MODEL=GHIRINGHELLI
[CNC]
; Siemens Torri (Vaumard)
IP=192.168.0.53
CPUTYPE=S7300
RACK=0
SLOT=2
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB700.DBB0
ADDR_WRITE=DB701.DBB0
SIZE_READ=52
SIZE_WRITE=138
;BIT0=CONN
BIT1=DB700.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB700.DBB3
BIT4=DB700.DBB4
BIT5=DB701.DBB4 ;bit ciclo in test == riscaldamento
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB700.DBW22
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
-65
View File
@@ -1,65 +0,0 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=SIEMENS_TORRI
[MACHINE]
VENDOR=TORRI
MODEL=GHIRINGHELLI M200
[CNC]
; Siemens Torri (GHIRINGHELLI M200)
IP=192.168.0.55
CPUTYPE=S7300
RACK=0
SLOT=2
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB700.DBB0
ADDR_WRITE=DB701.DBB0
SIZE_READ=52
SIZE_WRITE=138
;BIT0=CONN
BIT1=DB700.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB700.DBB3
BIT4=DB700.DBB4
BIT5=DB701.DBB4 ; bit ciclo in test == riscaldamento
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB700.DBW22
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=FALSE
[BRANCH]
NAME=develop
-71
View File
@@ -1,71 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Macchina filtraggio fanghi Aprochim x Jetco
CNCTYPE=SIEMENS_APROCHIM
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Aprochim
MODEL=Micro4000
[CNC]
IP=192.168.0.60
CPUTYPE=S71500
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB60.DBB0
ADDR_WRITE=DB60.DBB18
SIZE_READ=18
SIZE_WRITE=0
;BIT0=CONN
;BIT1=DB60.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
;BIT3=DB60.DBB3
;BIT4=DB60.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
;PZCOUNT_MODE=STD.DB550.DBDW0
PZCOUNT_MODE=NONE
DISABLE_PZCOUNT=TRUE
ENABLE_DYN_DATA=TRUE
TSVC_pressCamFilt=MAX:60
TSVC_pressLinUt=MAX:60
TSVC_tempH2O=MAX:60
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop
-66
View File
@@ -1,66 +0,0 @@
;Configurazione IOB-WIN
[IOB]
CNCTYPE=SIEMENS_TORRI
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=TORRI
MODEL=GHIRINGHELLI
[CNC]
; Siemens Torri (Vaumard)
IP=192.168.0.66
CPUTYPE=S7300
RACK=0
SLOT=2
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB700.DBB0
ADDR_WRITE=DB701.DBB0
SIZE_READ=52
SIZE_WRITE=138
;BIT0=CONN
BIT1=DB700.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB700.DBB3
BIT4=DB700.DBB4
BIT5=DB701.DBB4 ;bit ciclo in test == riscaldamento
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB700.DBW22
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=master
-80
View File
@@ -1,80 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Macchina pulitrice RobotService x Donati
CNCTYPE=SIEMENS_NWSE
PING_MS_TIMEOUT=500
MinDeltaSec=5
[MACHINE]
VENDOR=NWS
MODEL=Impianto Turi
[CNC]
IP=192.168.19.10
CPUTYPE=S71200
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.14
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB100.DBB0
ADDR_WRITE=DB101.DBB0
SIZE_READ=54
SIZE_WRITE=8
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB15.DBDW2
DISABLE_PZCOUNT=TRUE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; gestione custom timer
timerIntMs=30
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione scrittura string/char[]: true = string / false = char[]
WRITE_PRE=TRUE
; gestione emergenza forzata (ignora valore letto, mette sempre ARMED)
EMERGENCY_BYPASS=true
DISABLE_SEND_WDST=TRUE
; conf parametri memoria READ/WRITE
PARAM_CONF=GIACO_NWSE.json
; conf aree allarme
ALARM_CONF=GIACO_NWSE_alarm.json
[BRANCH]
NAME=master
; Tags manuali
[TAGS]
Customer=Giacovelli-Turi
HostOS=WIN
HostName=IOB-WIN-01
HostAddr=192.168.137.11
-217
View File
@@ -1,217 +0,0 @@
{
"mMapWrite": {
"resetCountAcqua": {
"name": "resetCountAcqua",
"description": "Reset contatori acqua OSMOSI / DEPURAZIONE",
"tipoMem": "Int",
"memAddr": "DB101.DBB0",
"index": 0,
"size": 2
}
},
"mMapRead": {
"CondOsmosi": {
"name": "CondOsmosi",
"description": "Conducib. H2O Osmosi",
"memAddr": "DB100.DBB40",
"tipoMem": "Int",
"index": 40,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1
},
"VolOsmosi": {
"name": "VolOsmosi",
"description": "Volume H2O Osmosi mc",
"memAddr": "DB100.DBB42",
"tipoMem": "Int",
"index": 40,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1
},
"StatoOsmosi": {
"name": "StatoOsmosi",
"description": "Stato Osmosi Inversa",
"memAddr": "DB100.DBB20",
"tipoMem": "BitMap",
"index": 20,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Impianto in servizio"
]
},
"TorbDepuraz": {
"name": "TorbDepuraz",
"description": "Torb. H2O Depurazione",
"memAddr": "DB100.DBB44",
"tipoMem": "Int",
"index": 44,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1
},
"VolDepuraz": {
"name": "VolDepuraz",
"description": "Volume acqua Depurazione mc",
"memAddr": "DB100.DBB46",
"tipoMem": "Int",
"index": 40,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1
},
"StatoDepurazione": {
"name": "StatoDepurazione",
"description": "Stato Depurazione",
"memAddr": "DB100.DBB22",
"tipoMem": "BitMap",
"index": 22,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Basso Livello",
"Alto Livello"
]
},
"TorbFiltri": {
"name": "TorbFiltri",
"description": "Torb. H2O Filtri",
"memAddr": "DB100.DBB48",
"tipoMem": "Int",
"index": 44,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1
},
"StatoFiltro01": {
"name": "StatoFiltro01",
"description": "Stato Filtro 1",
"memAddr": "DB100.DBB24",
"tipoMem": "BitMap",
"index": 24,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Spazzola in salita",
"Spazzola in discesa",
"Valvola scarico Chiusa",
"Valvola scarico Aperta",
"Impianto in Servizio",
"Impianto in Lavaggio"
]
},
"StatoFiltro02": {
"name": "StatoFiltro02",
"description": "Stato Filtro 2",
"memAddr": "DB100.DBB26",
"tipoMem": "BitMap",
"index": 26,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Spazzola in salita",
"Spazzola in discesa",
"Valvola scarico Chiusa",
"Valvola scarico Aperta",
"Impianto in Servizio",
"Impianto in Lavaggio"
]
},
"StatoFiltro03": {
"name": "StatoFiltro03",
"description": "Stato Filtro 3",
"memAddr": "DB100.DBB28",
"tipoMem": "BitMap",
"index": 28,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Spazzola in salita",
"Spazzola in discesa",
"Valvola scarico Chiusa",
"Valvola scarico Aperta",
"Impianto in Servizio",
"Impianto in Lavaggio"
]
},
"StatoFiltro04": {
"name": "StatoFiltro04",
"description": "Stato Filtro 4",
"memAddr": "DB100.DBB30",
"tipoMem": "BitMap",
"index": 30,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Spazzola in salita",
"Spazzola in discesa",
"Valvola scarico Chiusa",
"Valvola scarico Aperta",
"Impianto in Servizio",
"Impianto in Lavaggio"
]
},
"StatoFiltro05": {
"name": "StatoFiltro05",
"description": "Stato Filtro 5",
"memAddr": "DB100.DBB32",
"tipoMem": "BitMap",
"index": 32,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Spazzola in salita",
"Spazzola in discesa",
"Valvola scarico Chiusa",
"Valvola scarico Aperta",
"Impianto in Servizio",
"Impianto in Lavaggio"
]
},
"StatoFiltro06": {
"name": "StatoFiltro06",
"description": "Stato Filtro 6",
"memAddr": "DB100.DBB34",
"tipoMem": "BitMap",
"index": 34,
"size": 2,
"func": "MAX",
"period": 60,
"factor": 1,
"decodeMap": [
"Spazzola in salita",
"Spazzola in discesa",
"Valvola scarico Chiusa",
"Valvola scarico Aperta",
"Impianto in Servizio",
"Impianto in Lavaggio"
]
}
},
"optKVP": {
"fluxLogReduce": true,
"fluxLogRedDeadBand": 1.0,
"fluxLogResendPeriod": 60
}
}
@@ -1,202 +0,0 @@
[
{
"description": "Allarmi Impianto Osmosi",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB0",
"index": 0,
"size": 2,
"messages": [
"Avaria pompa ingresso",
"Avaria pompa alta pressione",
"Livello basso vasca osmosi",
"Livello basso vasca acqua grezza",
"Impianto in allarme",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"Allarme comunicazione con Gateway"
]
},
{
"description": "Allarmi Impianto Depurazione",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB2",
"index": 2,
"size": 2,
"messages": [
"Avaria pompa 1",
"Avaria pompa 2",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"Allarme comunicazione con Gateway"
]
},
{
"description": "Allarmi Filtro 1",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB4",
"index": 4,
"size": 2,
"messages": [
"Avaria pompa",
"Livello basso vasca",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
},
{
"description": "Allarmi Filtro 2",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB6",
"index": 6,
"size": 2,
"messages": [
"Avaria pompa",
"Livello basso vasca",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
},
{
"description": "Allarmi Filtro 3",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB8",
"index": 8,
"size": 2,
"messages": [
"Avaria pompa",
"Livello basso vasca",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
},
{
"description": "Allarmi Filtro 4",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB10",
"index": 10,
"size": 2,
"messages": [
"Avaria pompa",
"Livello basso vasca",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
},
{
"description": "Allarmi Filtro 5",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB12",
"index": 12,
"size": 2,
"messages": [
"Avaria pompa",
"Livello basso vasca",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
},
{
"description": "Allarmi Filtro 6",
"tipoMem": "Boolean",
"memAddr": "DB100.DBB14",
"index": 14,
"size": 2,
"messages": [
"Avaria pompa",
"Livello basso vasca",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
}
]
-75
View File
@@ -1,75 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE Manuale v.2 - 2024
CNCTYPE=SIEMENS_FAPE_2
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape Manuale
[CNC]
IP=192.168.1.57
CPUTYPE=S71200
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB17.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=16
SIZE_WRITE=70
;BIT0=CONN
;BIT1=DB17.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
;BIT3=DB17.DBB3
;BIT4=DB17.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;Fape vers: 1 originale, 2 = stato + ciclo, 3 = semafoto + stato + ciclo
FAPE_VERS=2
;FAPE_VERS=3
PZCOUNT_MODE=STD.DB17.DBDW6
PZ_GTOT_MADDR=STD.DB17.DBDW10
PZ_REQ_MADDR=STD.DB16.DBDW64
;PZ_CAD_MADDR=1602
;PZ_DONE_MADDR=1604
PARAM_CONF=GT693.json
;ENABLE_PZ_RESET=TRUE
;ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
;ENABLE_SEND_PZC_BLOCK=TRUE
;MIN_SEND_PZC_BLOCK=10
;MAX_SEND_PZC_BLOCK=100
;DynData
;ENABLE_DYN_DATA=TRUE
;DISABLE_SEND_WDST=TRUE
[BRANCH]
NAME=master
-202
View File
@@ -1,202 +0,0 @@
{
"mMapRead": {
"qtyWrk": {
"name": "qtyWrk",
"description": "Contatore Parziale",
"memAddr": "",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 5
},
"qtyTot": {
"name": "qtyTot",
"description": "Contatore Assoluto",
"memAddr": "",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 6
},
"DYNDATA": {
"name": "DYNDATA",
"description": "DynData check",
"memAddr": "",
"tipoMem": "String",
"index": 0,
"size": 4,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 13
}
},
"mMapWrite": {
"setArt": {
"name": "setArt",
"description": "Articolo",
"memAddr": "DB16.DBDW32",
"tipoMem": "String",
"index": 32,
"size": 30,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 1
},
"setComm": {
"name": "setComm",
"description": "Commessa",
"memAddr": "DB16.DBDW0",
"tipoMem": "String",
"index": 0,
"size": 30,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 2
},
"setPzComm": {
"name": "setPzComm",
"description": "Qty Commessa",
"memAddr": "DB16.DBDW64",
"tipoMem": "Int",
"index": 0,
"size": 4,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 3
},
"resetPzComm": {
"name": "resetPzComm",
"description": "Reset Contapezzi",
"memAddr": "DB16.DBB68.1",
"tipoMem": "Bool",
"index": 0,
"size": 1,
"func": "POINT",
"period": 60,
"factor": 1,
"displOrdinal": 3
}
},
"DataDecodMap": {
"StatoMacchina": {
"0": "COMUNICAZIONE ASSENTE",
"5": "5 EMERGENZA RIPRISTINATA",
"10": "10 MACCHINA IN POTENZA",
"15": "15 MACCHINA PRONTA PER CICLO LOCALE",
"20": "20 MACCHINA PRONTA PER CICLO CON ROBOT",
"25": "25 MACCHINA IN MANUALE",
"30": "30",
"35": "35",
"50": "50 CICLO RESET ATTIVO",
"55": "55 CICLO AUTOMATICO LOCALE ATTIVO",
"60": "60 CICLO AUTOMATICO CON ROBOT ATTIVO",
"65": "65",
"70": "70",
"100": "100 MANCANZA OLIO LUBRIFICAZIONE PEZZO",
"105": "105 MANCANZA OLIO LUBRIFICAZIONE CILINDRO",
"110": "110 ATTESA BARRIERE LIBERE",
"111": "111 ATTESA BLOCCAGGIO PORTELLO ANTERIORE",
"115": "115 ATTESA RILASCIO PULSANTE RESET",
"120": "120 ATTESA ASSE PUNZONATURA ALTO",
"125": "125 ATTESA BLOCCAGGIO PEZZO ALTO",
"126": "126 ATTESA BLOCCAGGIO PEZZO",
"130": "130 ATTESA CONTRASTO PEZZO DISINSERITO",
"135": "135 ATTESA CARRO IN POSIZIONE 1",
"140": "140 ATTESA CHIUSURA PORTELLO ROBOT",
"145": "145 ATTESA ROBOT FUORI INGOMBRO",
"150": "150 ATTESA TERMINE CICLO RESET",
"155": "155 TIMEOUT LUBRIFICAZIONE CILINDRO",
"160": "160 LIVELLO OLIO BASSO LUBRIFICA PEZZO",
"165": "165 LIVELLO OLIO BASSO LUBRIFICA CILINDRO",
"170": "170 ATTESA AREA TRASLAZIONE LIBERA",
"175": "175",
"200": "200",
"205": "205 ANOMALIA POSIZIONE PER CARICO ROBOT",
"210": "210 SOVRAPRESSIONE PUNZONATURA 1",
"215": "215 OLTRE QUOTA MASSIMA PUNZONATURA 1",
"220": "220 SOVRAPRESSIONE PUNZONATURA 2",
"225": "225 OLTRE QUOTA MASSIMA PUNZONATURA 1",
"230": "230 SOVRAPRESSIONE TRASLAZIONE CARRO",
"235": "235 TIMEOUT AVVIO DRIVE POMPA IDRAULICA",
"240": "240 SOVRAPRESSIONE MOVIMENTO PUNZONE",
"245": "245 ALLARME DRIVE POMPA IDRAULICA",
"250": "250 ANOMALIA ALIMENTAZIONE PNEUMATICA",
"255": "255 APERTURA ANOMALA PORTELLO ROBOT",
"260": "260 APERTURA ANOMALA PORTELLO ANTERIORE",
"265": "265 INTRUSIONE ANOMALA BARRIERE",
"270": "270 MACCHINA NON ATTIVA",
"275": "275 ALLARME AREA TRASLAZIONE NON LIBERA",
"280": "280",
"301": "301 ANOMALIA SALITA PUNZONATORE",
"302": "302",
"303": "303 ANOMALIA TRASLAZIONE CARRO",
"304": "304",
"305": "305 ANOMALIA ARRETRAMENTO CONTRASTO",
"306": "306",
"307": "307 ANOMALIA APERTURA STAFFAGGIO",
"403": "403 ANOMALIA STAFFAGGIO PEZZO",
"405": "405 ANOMALIA POSIZIONE CONTRASTO",
"407": "407 ANOMALIA PUNZONATURA 1",
"409": "409 ANOMALI TRASLAZIONE IN POSIZIONE 2",
"411": "411 ANOMALIA PUNZONATURA 2",
"413": "413 ANOMALIA ARRETRAMENTO CONTRASTO",
"415": "415 ANOMALIA SALITA STAFFAGGIO",
"417": "417 ANOMALI TRASLAZIONE IN POSIZIONE 1",
"419": "419 ANOMALIA DISATTIVAZIONE DRIVE POMPA"
},
"StepCiclo": {
"0": "CICLO NON ATTIVO",
"5": "CONTROLLO TIPO CARICO",
"10": "APERTURA PORTELLO ACCESSO AREA ROBOT",
"15": "ATTESA SCARICO CARICO PEZZO DA ROBOT",
"20": "ATTESA ROBOT FUORI AREA",
"25": "ATTESA CADUTA SEGNALE ROBOT FUORI AREA",
"30": "CHIUSURA PORTELLO ACCESSO AREA ROBOT",
"50": "FASE 1 STAFFAGGIO PEZZO",
"60": "FASE 2 POSIZIONAMENTO CONTRASTO PEZZO",
"69": "FASE 3 PUNZONATURA 1 LUBRIFICAZIONE PUNZONE",
"70": "FASE 3 PUNZONATURA 1 DISCESA RAPIDA",
"74": "FASE 3 PUNZONATURA 1 DISCESA LENTA",
"75": "FASE 3 PUNZONATURA 1 DISCESA LENTISSIMA",
"79": "FASE 3 PUNZONATURA 1 ARRESTO AZIONAMENTO",
"80": "FASE 3 PUNZONATURA 1 RITARDO PER RISALITA",
"85": "FASE 3 PUNZONATURA 1 SALITA LENTA",
"90": "FASE 3 PUNZONATURA 1 SALITA RAPIDA",
"95": "FASE 3 PUNZONATURA 1 SALITA FINALE",
"96": "FASE 3 PUNZONATURA 1 ARRESTO AZIONAMENTO",
"105": "FASE 4 TRASLAZIONE 1 RITARDO AVVIO",
"110": "FASE 4 TRASLAZIONE 1 MOVIMENTO SU PUNZONATURA 2",
"114": "FASE 4 TRASLAZIONE 1 ARRESTO AZIONAMENTO",
"115": "FASE 5 PUNZONATURA 2 RITARDO AVVIO",
"119": "FASE 5 PUNZONATURA 2 LUBRIFICAZIONE PUNZONE",
"120": "FASE 5 PUNZONATURA 2 DISCESA RAPIDA",
"124": "FASE 5 PUNZONATURA 2 DISCESA LENTA",
"125": "FASE 5 PUNZONATURA 2 DISCESA LENTISSIMA",
"126": "FASE 5 PUNZONATURA 2 ARRESTO AZIONAMENTO",
"130": "FASE 5 PUNZONATURA 2 RITARDO PER RISALITA",
"135": "FASE 5 PUNZONATURA 2 SALITA LENTA",
"140": "FASE 5 PUNZONATURA 2 SALITA RAPIDA",
"145": "FASE 5 PUNZONATURA 2 SALITA FINALE",
"146": "FASE 5 PUNZONATURA 2 ARRESTO AZIONAMENTO",
"155": "INCREMENTO CONTATORI PEZZI ESEGUITI",
"156": "FASE 6 TRASLAZIONE 2 RITARDO AVVIO",
"160": "FASE 6 TRASLAZIONE 2 MOVIMENTO SU PUNZONATURA 1",
"161": "FASE 6 TRASLAZIONE 2 ARRESTO AZIONAMENTO",
"165": "FASE 7 DISINSERIMENTO CONTRASTO",
"170": "FASE 8 DESTAFFAGGIO PEZZO",
"180": "DISATTIVAZIONE AZIONAMENTO",
"190": "VERIFICA RIAVVIO CICLO CON CARICO DA ROBOT",
"300": "CICLO TERMINATO"
}
}
}
-63
View File
@@ -1,63 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE Manuale v.2 - 2024
CNCTYPE=SIEMENS_FAPE_2
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape Automatica
[CNC]
IP=192.168.1.57
CPUTYPE=S71200
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
[BRANCH]
NAME=master
-63
View File
@@ -1,63 +0,0 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE Manuale v.2 - 2024
CNCTYPE=SIEMENS_FAPE_2
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape Automatica (Isola Okuma)
[CNC]
IP=192.168.1.57
CPUTYPE=S71200
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
[BRANCH]
NAME=master