Merge branch 'release/AddImaxIob'

This commit is contained in:
Samuele Locatelli
2022-11-08 09:31:17 +01:00
22 changed files with 1238 additions and 2 deletions
+5
View File
@@ -323,6 +323,11 @@ namespace IOB_UT_NEXT
/// </summary>
MODBUS_TCP_HELPI,
/// <summary>
/// Adapter Modubus TCP versione IMAX Aeromacchine (Jetco)
/// </summary>
MODBUS_TCP_IMAX_AEROMEC,
/// <summary>
/// Adapter MTConnect
/// </summary>
+5
View File
@@ -1641,6 +1641,11 @@ namespace IOB_WIN_NEXT
start.Enabled = true;
break;
case tipoAdapter.MODBUS_TCP_IMAX_AEROMEC:
iobObj = new IobModbusTCPImaxAeromec(this, IOBConf);
start.Enabled = true;
break;
case tipoAdapter.MTConnect:
iobObj = new IobMTC(this, IOBConf);
start.Enabled = true;
+77
View File
@@ -0,0 +1,77 @@
;Configurazione IOB-WIN
[IOB]
;Impianto Cedax di Turi (test) - Giacovelli
CNCTYPE=MODBUS_TCP_IMAX_AEROMEC
PING_MS_TIMEOUT=1000
MinDeltaSec=5
[MACHINE]
VENDOR=IMAX
MODEL=Filtro Aria
[CNC]
IP=192.168.0.80
PORT=502
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=40000
ADDR_WRITE=40000
SIZE_READ=30
SIZE_WRITE=0
HR_BASE_ADDR=40000
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB85.DBRE16
DISABLE_PZCOUNT=TRUE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione delta minimo accettabile tra min/MAX
DELTA_VAL=0.1
; clock base (da 10ms)
timerIntMs=10
; conf parametri memoria READ/WRITE
PARAM_CONF=3026.json
NO_PING=FALSE
; conf blocchi memoria x READ
MEM_BLOCK=3026_MBlock.json
; conf aree allarme
ALARM_CONF=3026_alarm.json
; rimozione check limiti min/max dynData
disDynDataRangeCheck=true
[BRANCH]
NAME=master
+77
View File
@@ -0,0 +1,77 @@
{
"mMapWrite": {
},
"mMapRead": {
"FreqInverter": {
"name": "FreqInverter",
"description": "Frequenza Inverter",
"memAddr": "40011",
"tipoMem": "Real",
"index": 11,
"size": 2,
"func": "MEDIAN",
"period": 90,
"factor": 1,
"minVal": 0,
"maxVal": 999999999,
"unit": "Hz"
},
"CDOreManuten": {
"name": "CDOreManuten",
"description": "Residuo ore a prossimo service",
"memAddr": "40013",
"tipoMem": "Int",
"index": 13,
"size": 1,
"func": "MEDIAN",
"period": 90,
"factor": 1,
"minVal": 0,
"maxVal": 999999999,
"unit": "h"
},
"COreTAsp1": {
"name": "COreTAsp1",
"description": "Totale ore funzionamento impianto",
"memAddr": "40014",
"tipoMem": "Int",
"index": 14,
"size": 1,
"func": "MEDIAN",
"period": 90,
"factor": 1,
"minVal": 0,
"maxVal": 999999999,
"unit": "h"
},
"COrePAsp1": {
"name": "COrePAsp1",
"description": "Parziale ore funzionamento impianto da ultimo service",
"memAddr": "40015",
"tipoMem": "Int",
"index": 15,
"size": 1,
"func": "MEDIAN",
"period": 90,
"factor": 1,
"minVal": 0,
"maxVal": 999999999,
"unit": "h"
},
"AmpereReale": {
"name": "AmpereReale",
"description": "Assorbimento aspiratore 1",
"memAddr": "40016",
"tipoMem": "Real",
"index": 16,
"size": 2,
"func": "MEDIAN",
"period": 90,
"factor": 1,
"minVal": 0,
"maxVal": 999999999,
"unit": "A"
}
}
}
+5
View File
@@ -0,0 +1,5 @@
{
"ReadBlocks": {
"40000": 30
}
}
+52
View File
@@ -0,0 +1,52 @@
[
{
"description": "Allarmi Impianto",
"tipoMem": "DInt",
"memAddr": "40003",
"index": 3,
"size": 2,
"messages": [
"ALLARME VENTILATORE 1",
"ALLARME VENTILATORE 2",
"WARNING FILTRI INTASATI",
"WARNING LIVELLO FILTRO",
"ALLARME LIVELLO FILTRO",
"ALLARME TAGLIAFUOCO 1 ASPIRAZIONE ",
"ALLARME TAGLIAFUOCO 2 ASPIRAZIONE ",
"CUMULATIVO ALLARMI ALIMENTAZIONI (24V AC-DC)",
"ALLARME FUORIUSCITA IQUINANTE ",
"ALLARME TERMOVELOCIMETRICO",
"ALLARME RILEVATORE SCINTILLE",
"ALLARME SPORTELLO APERTO",
"ALLARME MOTORE VALVOLA STELLARE FILTRO",
"ALLARME MOTORE COCLEA ",
"ALLARME MOTORE VALVOLA STELLARE CALDAIA",
"ALLARME MOTORE ESTRATTORE FILTRO"
]
},
{
"description": "Allarmi Impianto",
"tipoMem": "DInt",
"memAddr": "40004",
"index": 4,
"size": 2,
"messages": [
"ALLARME MOTORE ASPIRATORE TRAVASO",
"WARNING BY-PASS 1 ASPIRAZIONE",
"WARNING BY-PASS 2 ASPIRAZIONE",
"WARNING BY-PASS 3 ASPIRAZIONE",
"WARNING BY-PASS 4 ASPIRAZIONE",
"ALLARME TERMICO VIBRATORI",
"ALLARME INTASAMENTO ESTRATTORE",
"WARNING FILTRI INTASATI PLENUM",
"CUMULATIVO ALLARMI RECUPERATORE",
"WARNING SERRANDA 1 PARTENZA ASPIRAZIONE",
"WARNING SERRANDA 2 PARTENZA ASPIRAZIONE",
"WARNING SERRANDA 3 PARTENZA ASPIRAZIONE",
"ALLARME IMPLOSIONE TUBAZIONI",
"WARNING IMPLOSIONE TUBAZIONI",
"ALLARME VENTILATORE 3",
"ALLARME INTASAMENTO TASCHE"
]
}
]
+5
View File
@@ -235,6 +235,7 @@
</Compile>
<Compile Include="IobIcoelDb.cs" />
<Compile Include="IobIcoelSoap.cs" />
<Compile Include="IobModbusTCPImaxAeromec.cs" />
<Compile Include="IobModbusTCPCenterfrigo.cs" />
<Compile Include="IobModbusTCPHelpi.cs" />
<Compile Include="IobModbusTCPCedax.cs" />
@@ -315,9 +316,13 @@
<None Include="DATA\CONF\1033.ini" />
<None Include="DATA\CONF\BAGLIETTO_CIMOLAI_01.ini" />
<None Include="DATA\CONF\BAGLIETTO_CIMOLAI_01.json" />
<None Include="DATA\CONF\3026.ini" />
<None Include="DATA\CONF\3026.json" />
<None Include="DATA\CONF\GIACO_CEDAX_001.ini" />
<None Include="DATA\CONF\GIACO_CEDAX_001.json" />
<None Include="DATA\CONF\3026_alarm.json" />
<None Include="DATA\CONF\GIACO_CEDAX_001_alarm.json" />
<None Include="DATA\CONF\3026_MBlock.json" />
<None Include="DATA\CONF\GIACO_CEDAX_001_MBlock.json" />
<None Include="DATA\CONF\GIACO_CEDAX_002.ini" />
<None Include="DATA\CONF\GIACO_CEDAX_002.json" />
+203
View File
@@ -0,0 +1,203 @@
using EasyModbus;
using System;
namespace IOB_WIN_NEXT
{
/* --------------------------------------------------------------------------------
* Controlli ModBusTCP IMAS Aeromeccanica
* - protocollo ModBus TCP
* - specifico comportamento impianti filtrazione IMAS Aeromeccanica
* - gestione allarmi
*
* STRUTTURA MEMORIA a banchi di UInt16, convertiti successivamente in int EVENTUALMENTE divisi per 10/100/1000
* G:\Drive condivisi\30_Clienti\Jetco\Manuali CNC-PLC\Aspiratori
*
* -------------------------------------------------------------------------------- */
public class IobModbusTCPImaxAeromec : IobModbusTCP
{
#region Public Constructors
/// <summary>
/// Classe base con i metodi x ModBusTCP
/// </summary>
/// <param name="caller"></param>
/// <param name="IOBConf"></param>
public IobModbusTCPImaxAeromec(AdapterForm caller, IobConfiguration IOBConf) : base(caller, IOBConf)
{
lgInfo("NEW IOB ModBus TCP IMAS Aeromec");
// provo lettura una prima volta i dati DYN
if (currPLC != null && currPLC.Connected)
{
try
{
processDynData();
}
catch (Exception exc)
{
lgError($"Eccezione in processDynData iniziale x ModBus TCP IMAS Aeromec:{Environment.NewLine}{exc}");
}
}
}
#endregion Public Constructors
#region Protected Methods
/// <summary>
/// Restituisce status di emergenza, hard coded dall'area di allarmi
/// </summary>
protected bool EStop
{
get
{
bool answ = false;
int currStatus = 0;
// hard coded
int statusReg = 40003;
// deve avere allarmi (è un allarme EStop)
if (hasAlarms())
{
int[] listInt = new int[2];
listInt = HoldingRegisterLUT[statusReg];
currStatus = ModbusClient.ConvertRegistersToInt(listInt);
// hard coded il 5° bit
answ = ((currStatus & (1 << 9)) > 0);
}
return answ;
}
}
/// <summary>
/// Restituisce status di LAVORA, hard coded
/// </summary>
protected bool Work
{
get
{
bool answ = false;
int currStatus = 0;
// hard coded
int statusReg = 40003;
int[] listInt = new int[2];
listInt = HoldingRegisterLUT[statusReg];
currStatus = ModbusClient.ConvertRegistersToInt(listInt);
// hard coded il 5° bit
answ = ((currStatus & (1 << 0)) > 0);
return answ;
}
}
/// <summary>
/// Restituisce status di AUTOmatico, hard coded
/// </summary>
protected bool Auto
{
get
{
bool answ = false;
int currStatus = 0;
// hard coded
int statusReg = 40003;
int[] listInt = new int[2];
listInt = HoldingRegisterLUT[statusReg];
currStatus = ModbusClient.ConvertRegistersToInt(listInt);
// hard coded il 5° bit
answ = ((currStatus & (1 << 14)) > 0);
return answ;
}
}
/// <summary>
/// Effettua decodifica aree memoria alla bitmap usata x MAPO
/// </summary>
protected override void decodeToBaseBitmap()
{
// init a zero...
B_input = 0;
/* -----------------------------------------------------
* bitmap MAPO STANDARD 60
* B0: POWER_ON
* B1: RUN
* B2: pzCount
* B3: allarme
* B4: manuale
* B5: slowTC
* B6: WarmUpCoolDown
* B7: EmergArmata
*
----------------------------------------------------- */
var MemInt = new byte[2];
int byteSignals = 0;
// bit 0 (poweron) imposto a 1 SE connected...
if (currPLC.Connected)
{
byteSignals += (1 << 0);
}
// processo dagli stati + gravi...
if (!EStop)
{
byteSignals += (1 << 7);
}
// processo dagli stati + gravi...
if (hasAlarms())
{
byteSignals += (1 << 3);
}
if (Work)
{
byteSignals += (1 << 1);
}
if (!Auto)
{
byteSignals += (1 << 4);
}
// salvo!
B_input = byteSignals;
}
#endregion Protected Methods
#region Private Methods
private void testBlockRead(int baseAddr, int numByte)
{
int baseHold = 40001;
int[] readTestFull = new int[2];
lgTrace($"-------------------- Inizio test lettura {baseAddr} --------------------");
try
{
stopwatch.Restart();
readTestFull = currPLC.ReadHoldingRegisters(baseAddr - baseHold, numByte);
stopwatch.Stop();
lgTrace($"Stats lettura | {readTestFull.Length} val | {stopwatch.ElapsedMilliseconds}ms");
}
catch
{ }
for (int i = 0; i < readTestFull.Length / 2; i++)
{
int[] thisSet = new int[2];
Array.Copy(readTestFull, i * 2, thisSet, 0, 2);
lgTrace($"{baseAddr + i * 2:000} | HoldingRegisters: {thisSet[0]} / {thisSet[1]} | Val Real: {ModbusClient.ConvertRegistersToFloat(thisSet):N6}");
}
lgTrace("-------------------- Completato test lettura {baseAddr} --------------------");
}
private void testRead()
{
foreach (var item in memSetR)
{
testBlockRead(item.Key, item.Value);
}
}
#endregion Private Methods
}
}
+8 -2
View File
@@ -1,12 +1,14 @@
Microsoft Visual Studio Solution File, Format Version 12.00
# Visual Studio Version 17
VisualStudioVersion = 17.3.32922.545
# Visual Studio Version 16
VisualStudioVersion = 16.0.32901.82
MinimumVisualStudioVersion = 10.0.40219.1
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "TestClientMan", "TestClientMan\TestClientMan.csproj", "{533B1F01-3061-4105-BA7F-ADAA72A74C2C}"
EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "IobManComm", "IobManComm\IobManComm.csproj", "{FEC10BD2-65A7-4FD3-B59C-8200BF80AB51}"
EndProject
Project("{F184B08F-C81C-45F6-A57F-5ABD9991F28F}") = "TestClientVB", "TestClientVB\TestClientVB.vbproj", "{F8C3D948-DADA-49EE-9697-54A4B63FD5DE}"
EndProject
Global
GlobalSection(SolutionConfigurationPlatforms) = preSolution
Debug|Any CPU = Debug|Any CPU
@@ -21,6 +23,10 @@ Global
{FEC10BD2-65A7-4FD3-B59C-8200BF80AB51}.Debug|Any CPU.Build.0 = Debug|Any CPU
{FEC10BD2-65A7-4FD3-B59C-8200BF80AB51}.Release|Any CPU.ActiveCfg = Release|Any CPU
{FEC10BD2-65A7-4FD3-B59C-8200BF80AB51}.Release|Any CPU.Build.0 = Release|Any CPU
{F8C3D948-DADA-49EE-9697-54A4B63FD5DE}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
{F8C3D948-DADA-49EE-9697-54A4B63FD5DE}.Debug|Any CPU.Build.0 = Debug|Any CPU
{F8C3D948-DADA-49EE-9697-54A4B63FD5DE}.Release|Any CPU.ActiveCfg = Release|Any CPU
{F8C3D948-DADA-49EE-9697-54A4B63FD5DE}.Release|Any CPU.Build.0 = Release|Any CPU
EndGlobalSection
GlobalSection(SolutionProperties) = preSolution
HideSolutionNode = FALSE
+14
View File
@@ -0,0 +1,14 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<startup>
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.6.2" />
</startup>
<runtime>
<assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">
<dependentAssembly>
<assemblyIdentity name="System.IO.Compression" publicKeyToken="b77a5c561934e089" culture="neutral" />
<bindingRedirect oldVersion="0.0.0.0-4.1.2.0" newVersion="4.1.2.0" />
</dependentAssembly>
</assemblyBinding>
</runtime>
</configuration>
+82
View File
@@ -0,0 +1,82 @@
<Global.Microsoft.VisualBasic.CompilerServices.DesignerGenerated()> _
Partial Class Form1
Inherits System.Windows.Forms.Form
'Form overrides dispose to clean up the component list.
<System.Diagnostics.DebuggerNonUserCode()> _
Protected Overrides Sub Dispose(ByVal disposing As Boolean)
Try
If disposing AndAlso components IsNot Nothing Then
components.Dispose()
End If
Finally
MyBase.Dispose(disposing)
End Try
End Sub
'Required by the Windows Form Designer
Private components As System.ComponentModel.IContainer
'NOTE: The following procedure is required by the Windows Form Designer
'It can be modified using the Windows Form Designer.
'Do not modify it using the code editor.
<System.Diagnostics.DebuggerStepThrough()> _
Private Sub InitializeComponent()
Me.components = New System.ComponentModel.Container()
Me.chkOnline = New System.Windows.Forms.CheckBox()
Me.Timer1 = New System.Windows.Forms.Timer(Me.components)
Me.txtConf = New System.Windows.Forms.TextBox()
Me.Label1 = New System.Windows.Forms.Label()
Me.SuspendLayout()
'
'chkOnline
'
Me.chkOnline.AutoSize = True
Me.chkOnline.Location = New System.Drawing.Point(67, 72)
Me.chkOnline.Name = "chkOnline"
Me.chkOnline.Size = New System.Drawing.Size(54, 17)
Me.chkOnline.TabIndex = 0
Me.chkOnline.Text = "online"
Me.chkOnline.UseVisualStyleBackColor = True
'
'Timer1
'
Me.Timer1.Interval = 1000
'
'txtConf
'
Me.txtConf.Location = New System.Drawing.Point(67, 38)
Me.txtConf.Name = "txtConf"
Me.txtConf.Size = New System.Drawing.Size(100, 20)
Me.txtConf.TabIndex = 1
Me.txtConf.Text = "demo_file.ini"
'
'Label1
'
Me.Label1.AutoSize = True
Me.Label1.Location = New System.Drawing.Point(17, 41)
Me.Label1.Name = "Label1"
Me.Label1.Size = New System.Drawing.Size(44, 13)
Me.Label1.TabIndex = 2
Me.Label1.Text = "conf file"
'
'Form1
'
Me.AutoScaleDimensions = New System.Drawing.SizeF(6.0!, 13.0!)
Me.AutoScaleMode = System.Windows.Forms.AutoScaleMode.Font
Me.ClientSize = New System.Drawing.Size(800, 450)
Me.Controls.Add(Me.Label1)
Me.Controls.Add(Me.txtConf)
Me.Controls.Add(Me.chkOnline)
Me.Name = "Form1"
Me.Text = "Form1"
Me.ResumeLayout(False)
Me.PerformLayout()
End Sub
Friend WithEvents chkOnline As CheckBox
Friend WithEvents Timer1 As Timer
Friend WithEvents txtConf As TextBox
Friend WithEvents Label1 As Label
End Class
+123
View File
@@ -0,0 +1,123 @@
<?xml version="1.0" encoding="utf-8"?>
<root>
<!--
Microsoft ResX Schema
Version 2.0
The primary goals of this format is to allow a simple XML format
that is mostly human readable. The generation and parsing of the
various data types are done through the TypeConverter classes
associated with the data types.
Example:
... ado.net/XML headers & schema ...
<resheader name="resmimetype">text/microsoft-resx</resheader>
<resheader name="version">2.0</resheader>
<resheader name="reader">System.Resources.ResXResourceReader, System.Windows.Forms, ...</resheader>
<resheader name="writer">System.Resources.ResXResourceWriter, System.Windows.Forms, ...</resheader>
<data name="Name1"><value>this is my long string</value><comment>this is a comment</comment></data>
<data name="Color1" type="System.Drawing.Color, System.Drawing">Blue</data>
<data name="Bitmap1" mimetype="application/x-microsoft.net.object.binary.base64">
<value>[base64 mime encoded serialized .NET Framework object]</value>
</data>
<data name="Icon1" type="System.Drawing.Icon, System.Drawing" mimetype="application/x-microsoft.net.object.bytearray.base64">
<value>[base64 mime encoded string representing a byte array form of the .NET Framework object]</value>
<comment>This is a comment</comment>
</data>
There are any number of "resheader" rows that contain simple
name/value pairs.
Each data row contains a name, and value. The row also contains a
type or mimetype. Type corresponds to a .NET class that support
text/value conversion through the TypeConverter architecture.
Classes that don't support this are serialized and stored with the
mimetype set.
The mimetype is used for serialized objects, and tells the
ResXResourceReader how to depersist the object. This is currently not
extensible. For a given mimetype the value must be set accordingly:
Note - application/x-microsoft.net.object.binary.base64 is the format
that the ResXResourceWriter will generate, however the reader can
read any of the formats listed below.
mimetype: application/x-microsoft.net.object.binary.base64
value : The object must be serialized with
: System.Runtime.Serialization.Formatters.Binary.BinaryFormatter
: and then encoded with base64 encoding.
mimetype: application/x-microsoft.net.object.soap.base64
value : The object must be serialized with
: System.Runtime.Serialization.Formatters.Soap.SoapFormatter
: and then encoded with base64 encoding.
mimetype: application/x-microsoft.net.object.bytearray.base64
value : The object must be serialized into a byte array
: using a System.ComponentModel.TypeConverter
: and then encoded with base64 encoding.
-->
<xsd:schema id="root" xmlns="" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:msdata="urn:schemas-microsoft-com:xml-msdata">
<xsd:import namespace="http://www.w3.org/XML/1998/namespace" />
<xsd:element name="root" msdata:IsDataSet="true">
<xsd:complexType>
<xsd:choice maxOccurs="unbounded">
<xsd:element name="metadata">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" />
</xsd:sequence>
<xsd:attribute name="name" use="required" type="xsd:string" />
<xsd:attribute name="type" type="xsd:string" />
<xsd:attribute name="mimetype" type="xsd:string" />
<xsd:attribute ref="xml:space" />
</xsd:complexType>
</xsd:element>
<xsd:element name="assembly">
<xsd:complexType>
<xsd:attribute name="alias" type="xsd:string" />
<xsd:attribute name="name" type="xsd:string" />
</xsd:complexType>
</xsd:element>
<xsd:element name="data">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
<xsd:element name="comment" type="xsd:string" minOccurs="0" msdata:Ordinal="2" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" use="required" msdata:Ordinal="1" />
<xsd:attribute name="type" type="xsd:string" msdata:Ordinal="3" />
<xsd:attribute name="mimetype" type="xsd:string" msdata:Ordinal="4" />
<xsd:attribute ref="xml:space" />
</xsd:complexType>
</xsd:element>
<xsd:element name="resheader">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" use="required" />
</xsd:complexType>
</xsd:element>
</xsd:choice>
</xsd:complexType>
</xsd:element>
</xsd:schema>
<resheader name="resmimetype">
<value>text/microsoft-resx</value>
</resheader>
<resheader name="version">
<value>2.0</value>
</resheader>
<resheader name="reader">
<value>System.Resources.ResXResourceReader, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
</resheader>
<resheader name="writer">
<value>System.Resources.ResXResourceWriter, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
</resheader>
<metadata name="Timer1.TrayLocation" type="System.Drawing.Point, System.Drawing, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a">
<value>17, 17</value>
</metadata>
</root>
+63
View File
@@ -0,0 +1,63 @@
Imports IobManComm
Public Class Form1
Protected rwd As RedisWatchDog
Protected count As Integer
Private Sub Timer1_Tick(sender As Object, e As EventArgs) Handles Timer1.Tick
' preparo update sul canale di comunicazione
Dim adesso As Date = Date.Now
Dim currStatus As New IobWinStatus
currStatus = rwd.iobStatus
' aggiorno valori, ad esempio IN da macchina, OUT verso macchina? last update = ultima comunicazione?
currStatus.lastDataIn = adesso.AddSeconds(-3)
currStatus.lastDataOut = adesso.AddSeconds(-2)
currStatus.lastUpdate = adesso
currStatus.online = chkOnline.Checked
' note libere x indicare ultimo task?
currStatus.freeNotes = $"Conteggio: {count}"
' salvo e invio
rwd.iobStatus = currStatus
count = count + 1
End Sub
Private Sub Form1_Load(sender As Object, e As EventArgs) Handles MyBase.Load
' avvio i componenti...
' tipicamente è il primo arg con cui sia vvia il sw
Dim codIob As String = "demo_conf"
txtConf.Text = codIob + ".ini"
' valori da recuperare da ini... che dovranno corrispondere nel programma che fa partire il sw
Dim tipoIob As String = "SERIAL"
Dim appName As String = "CVSER"
' 14 è normalmente libero... valori ammessi 0..15)
Dim redisDb As Integer = 14
' periodo minimo x considerare il dato variato da parte del server
Dim minSecDelta As Integer = 1
Dim adesso As Date = Date.Now
'' preparo oggetto x gestione WathDog
rwd = New RedisWatchDog(codIob, tipoIob, appName, redisDb, minSecDelta)
Dim currStatus As New IobWinStatus
currStatus = rwd.iobStatus
currStatus.freeNotes = "starting"
currStatus.online = False
' salvo e invio
rwd.iobStatus = currStatus
' avvio il timer
Timer1.Start()
End Sub
End Class
@@ -0,0 +1,38 @@
'------------------------------------------------------------------------------
' <auto-generated>
' This code was generated by a tool.
' Runtime Version:4.0.30319.42000
'
' Changes to this file may cause incorrect behavior and will be lost if
' the code is regenerated.
' </auto-generated>
'------------------------------------------------------------------------------
Option Strict On
Option Explicit On
Namespace My
'NOTE: This file is auto-generated; do not modify it directly. To make changes,
' or if you encounter build errors in this file, go to the Project Designer
' (go to Project Properties or double-click the My Project node in
' Solution Explorer), and make changes on the Application tab.
'
Partial Friend Class MyApplication
<Global.System.Diagnostics.DebuggerStepThroughAttribute()> _
Public Sub New()
MyBase.New(Global.Microsoft.VisualBasic.ApplicationServices.AuthenticationMode.Windows)
Me.IsSingleInstance = false
Me.EnableVisualStyles = true
Me.SaveMySettingsOnExit = true
Me.ShutDownStyle = Global.Microsoft.VisualBasic.ApplicationServices.ShutdownMode.AfterMainFormCloses
End Sub
<Global.System.Diagnostics.DebuggerStepThroughAttribute()> _
Protected Overrides Sub OnCreateMainForm()
Me.MainForm = Global.TestClientVB.Form1
End Sub
End Class
End Namespace
@@ -0,0 +1,11 @@
<?xml version="1.0" encoding="utf-8"?>
<MyApplicationData xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<MySubMain>true</MySubMain>
<MainForm>Form1</MainForm>
<SingleInstance>false</SingleInstance>
<ShutdownMode>0</ShutdownMode>
<EnableVisualStyles>true</EnableVisualStyles>
<AuthenticationMode>0</AuthenticationMode>
<ApplicationType>0</ApplicationType>
<SaveMySettingsOnExit>true</SaveMySettingsOnExit>
</MyApplicationData>
@@ -0,0 +1,35 @@
Imports System
Imports System.Reflection
Imports System.Runtime.InteropServices
' General Information about an assembly is controlled through the following
' set of attributes. Change these attribute values to modify the information
' associated with an assembly.
' Review the values of the assembly attributes
<Assembly: AssemblyTitle("TestClientVB")>
<Assembly: AssemblyDescription("")>
<Assembly: AssemblyCompany("")>
<Assembly: AssemblyProduct("TestClientVB")>
<Assembly: AssemblyCopyright("Copyright © 2022")>
<Assembly: AssemblyTrademark("")>
<Assembly: ComVisible(False)>
'The following GUID is for the ID of the typelib if this project is exposed to COM
<Assembly: Guid("36d58db3-ba65-40bd-a181-8e67062f4d27")>
' Version information for an assembly consists of the following four values:
'
' Major Version
' Minor Version
' Build Number
' Revision
'
' You can specify all the values or you can default the Build and Revision Numbers
' by using the '*' as shown below:
' <Assembly: AssemblyVersion("1.0.*")>
<Assembly: AssemblyVersion("1.0.0.0")>
<Assembly: AssemblyFileVersion("1.0.0.0")>
@@ -0,0 +1,62 @@
'------------------------------------------------------------------------------
' <auto-generated>
' This code was generated by a tool.
' Runtime Version:4.0.30319.42000
'
' Changes to this file may cause incorrect behavior and will be lost if
' the code is regenerated.
' </auto-generated>
'------------------------------------------------------------------------------
Option Strict On
Option Explicit On
Namespace My.Resources
'This class was auto-generated by the StronglyTypedResourceBuilder
'class via a tool like ResGen or Visual Studio.
'To add or remove a member, edit your .ResX file then rerun ResGen
'with the /str option, or rebuild your VS project.
'''<summary>
''' A strongly-typed resource class, for looking up localized strings, etc.
'''</summary>
<Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Resources.Tools.StronglyTypedResourceBuilder", "4.0.0.0"), _
Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.Runtime.CompilerServices.CompilerGeneratedAttribute(), _
Global.Microsoft.VisualBasic.HideModuleNameAttribute()> _
Friend Module Resources
Private resourceMan As Global.System.Resources.ResourceManager
Private resourceCulture As Global.System.Globalization.CultureInfo
'''<summary>
''' Returns the cached ResourceManager instance used by this class.
'''</summary>
<Global.System.ComponentModel.EditorBrowsableAttribute(Global.System.ComponentModel.EditorBrowsableState.Advanced)> _
Friend ReadOnly Property ResourceManager() As Global.System.Resources.ResourceManager
Get
If Object.ReferenceEquals(resourceMan, Nothing) Then
Dim temp As Global.System.Resources.ResourceManager = New Global.System.Resources.ResourceManager("TestClientVB.Resources", GetType(Resources).Assembly)
resourceMan = temp
End If
Return resourceMan
End Get
End Property
'''<summary>
''' Overrides the current thread's CurrentUICulture property for all
''' resource lookups using this strongly typed resource class.
'''</summary>
<Global.System.ComponentModel.EditorBrowsableAttribute(Global.System.ComponentModel.EditorBrowsableState.Advanced)> _
Friend Property Culture() As Global.System.Globalization.CultureInfo
Get
Return resourceCulture
End Get
Set(ByVal value As Global.System.Globalization.CultureInfo)
resourceCulture = value
End Set
End Property
End Module
End Namespace
@@ -0,0 +1,117 @@
<?xml version="1.0" encoding="utf-8"?>
<root>
<!--
Microsoft ResX Schema
Version 2.0
The primary goals of this format is to allow a simple XML format
that is mostly human readable. The generation and parsing of the
various data types are done through the TypeConverter classes
associated with the data types.
Example:
... ado.net/XML headers & schema ...
<resheader name="resmimetype">text/microsoft-resx</resheader>
<resheader name="version">2.0</resheader>
<resheader name="reader">System.Resources.ResXResourceReader, System.Windows.Forms, ...</resheader>
<resheader name="writer">System.Resources.ResXResourceWriter, System.Windows.Forms, ...</resheader>
<data name="Name1"><value>this is my long string</value><comment>this is a comment</comment></data>
<data name="Color1" type="System.Drawing.Color, System.Drawing">Blue</data>
<data name="Bitmap1" mimetype="application/x-microsoft.net.object.binary.base64">
<value>[base64 mime encoded serialized .NET Framework object]</value>
</data>
<data name="Icon1" type="System.Drawing.Icon, System.Drawing" mimetype="application/x-microsoft.net.object.bytearray.base64">
<value>[base64 mime encoded string representing a byte array form of the .NET Framework object]</value>
<comment>This is a comment</comment>
</data>
There are any number of "resheader" rows that contain simple
name/value pairs.
Each data row contains a name, and value. The row also contains a
type or mimetype. Type corresponds to a .NET class that support
text/value conversion through the TypeConverter architecture.
Classes that don't support this are serialized and stored with the
mimetype set.
The mimetype is used for serialized objects, and tells the
ResXResourceReader how to depersist the object. This is currently not
extensible. For a given mimetype the value must be set accordingly:
Note - application/x-microsoft.net.object.binary.base64 is the format
that the ResXResourceWriter will generate, however the reader can
read any of the formats listed below.
mimetype: application/x-microsoft.net.object.binary.base64
value : The object must be serialized with
: System.Serialization.Formatters.Binary.BinaryFormatter
: and then encoded with base64 encoding.
mimetype: application/x-microsoft.net.object.soap.base64
value : The object must be serialized with
: System.Runtime.Serialization.Formatters.Soap.SoapFormatter
: and then encoded with base64 encoding.
mimetype: application/x-microsoft.net.object.bytearray.base64
value : The object must be serialized into a byte array
: using a System.ComponentModel.TypeConverter
: and then encoded with base64 encoding.
-->
<xsd:schema id="root" xmlns="" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:msdata="urn:schemas-microsoft-com:xml-msdata">
<xsd:element name="root" msdata:IsDataSet="true">
<xsd:complexType>
<xsd:choice maxOccurs="unbounded">
<xsd:element name="metadata">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" />
<xsd:attribute name="type" type="xsd:string" />
<xsd:attribute name="mimetype" type="xsd:string" />
</xsd:complexType>
</xsd:element>
<xsd:element name="assembly">
<xsd:complexType>
<xsd:attribute name="alias" type="xsd:string" />
<xsd:attribute name="name" type="xsd:string" />
</xsd:complexType>
</xsd:element>
<xsd:element name="data">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
<xsd:element name="comment" type="xsd:string" minOccurs="0" msdata:Ordinal="2" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" msdata:Ordinal="1" />
<xsd:attribute name="type" type="xsd:string" msdata:Ordinal="3" />
<xsd:attribute name="mimetype" type="xsd:string" msdata:Ordinal="4" />
</xsd:complexType>
</xsd:element>
<xsd:element name="resheader">
<xsd:complexType>
<xsd:sequence>
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
</xsd:sequence>
<xsd:attribute name="name" type="xsd:string" use="required" />
</xsd:complexType>
</xsd:element>
</xsd:choice>
</xsd:complexType>
</xsd:element>
</xsd:schema>
<resheader name="resmimetype">
<value>text/microsoft-resx</value>
</resheader>
<resheader name="version">
<value>2.0</value>
</resheader>
<resheader name="reader">
<value>System.Resources.ResXResourceReader, System.Windows.Forms, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
</resheader>
<resheader name="writer">
<value>System.Resources.ResXResourceWriter, System.Windows.Forms, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
</resheader>
</root>
@@ -0,0 +1,73 @@
'------------------------------------------------------------------------------
' <auto-generated>
' This code was generated by a tool.
' Runtime Version:4.0.30319.42000
'
' Changes to this file may cause incorrect behavior and will be lost if
' the code is regenerated.
' </auto-generated>
'------------------------------------------------------------------------------
Option Strict On
Option Explicit On
Namespace My
<Global.System.Runtime.CompilerServices.CompilerGeneratedAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("Microsoft.VisualStudio.Editors.SettingsDesigner.SettingsSingleFileGenerator", "11.0.0.0"), _
Global.System.ComponentModel.EditorBrowsableAttribute(Global.System.ComponentModel.EditorBrowsableState.Advanced)> _
Partial Friend NotInheritable Class MySettings
Inherits Global.System.Configuration.ApplicationSettingsBase
Private Shared defaultInstance As MySettings = CType(Global.System.Configuration.ApplicationSettingsBase.Synchronized(New MySettings), MySettings)
#Region "My.Settings Auto-Save Functionality"
#If _MyType = "WindowsForms" Then
Private Shared addedHandler As Boolean
Private Shared addedHandlerLockObject As New Object
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), Global.System.ComponentModel.EditorBrowsableAttribute(Global.System.ComponentModel.EditorBrowsableState.Advanced)> _
Private Shared Sub AutoSaveSettings(ByVal sender As Global.System.Object, ByVal e As Global.System.EventArgs)
If My.Application.SaveMySettingsOnExit Then
My.Settings.Save()
End If
End Sub
#End If
#End Region
Public Shared ReadOnly Property [Default]() As MySettings
Get
#If _MyType = "WindowsForms" Then
If Not addedHandler Then
SyncLock addedHandlerLockObject
If Not addedHandler Then
AddHandler My.Application.Shutdown, AddressOf AutoSaveSettings
addedHandler = True
End If
End SyncLock
End If
#End If
Return defaultInstance
End Get
End Property
End Class
End Namespace
Namespace My
<Global.Microsoft.VisualBasic.HideModuleNameAttribute(), _
Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.Runtime.CompilerServices.CompilerGeneratedAttribute()> _
Friend Module MySettingsProperty
<Global.System.ComponentModel.Design.HelpKeywordAttribute("My.Settings")> _
Friend ReadOnly Property Settings() As Global.TestClientVB.My.MySettings
Get
Return Global.TestClientVB.My.MySettings.Default
End Get
End Property
End Module
End Namespace
@@ -0,0 +1,7 @@
<?xml version='1.0' encoding='utf-8'?>
<SettingsFile xmlns="http://schemas.microsoft.com/VisualStudio/2004/01/settings" CurrentProfile="(Default)" UseMySettingsClassName="true">
<Profiles>
<Profile Name="(Default)" />
</Profiles>
<Settings />
</SettingsFile>
@@ -0,0 +1,172 @@
<?xml version="1.0" encoding="utf-8"?>
<Project ToolsVersion="15.0" xmlns="http://schemas.microsoft.com/developer/msbuild/2003">
<Import Project="$(MSBuildExtensionsPath)\$(MSBuildToolsVersion)\Microsoft.Common.props" Condition="Exists('$(MSBuildExtensionsPath)\$(MSBuildToolsVersion)\Microsoft.Common.props')" />
<PropertyGroup>
<Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration>
<Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform>
<ProjectGuid>{F8C3D948-DADA-49EE-9697-54A4B63FD5DE}</ProjectGuid>
<OutputType>WinExe</OutputType>
<StartupObject>TestClientVB.My.MyApplication</StartupObject>
<RootNamespace>TestClientVB</RootNamespace>
<AssemblyName>TestClientVB</AssemblyName>
<FileAlignment>512</FileAlignment>
<MyType>WindowsForms</MyType>
<TargetFrameworkVersion>v4.6.2</TargetFrameworkVersion>
<AutoGenerateBindingRedirects>true</AutoGenerateBindingRedirects>
<Deterministic>true</Deterministic>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Debug|AnyCPU' ">
<PlatformTarget>AnyCPU</PlatformTarget>
<DebugSymbols>true</DebugSymbols>
<DebugType>full</DebugType>
<DefineDebug>true</DefineDebug>
<DefineTrace>true</DefineTrace>
<OutputPath>bin\Debug\</OutputPath>
<DocumentationFile>TestClientVB.xml</DocumentationFile>
<NoWarn>42016,41999,42017,42018,42019,42032,42036,42020,42021,42022</NoWarn>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">
<PlatformTarget>AnyCPU</PlatformTarget>
<DebugType>pdbonly</DebugType>
<DefineDebug>false</DefineDebug>
<DefineTrace>true</DefineTrace>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DocumentationFile>TestClientVB.xml</DocumentationFile>
<NoWarn>42016,41999,42017,42018,42019,42032,42036,42020,42021,42022</NoWarn>
</PropertyGroup>
<PropertyGroup>
<OptionExplicit>On</OptionExplicit>
</PropertyGroup>
<PropertyGroup>
<OptionCompare>Binary</OptionCompare>
</PropertyGroup>
<PropertyGroup>
<OptionStrict>Off</OptionStrict>
</PropertyGroup>
<PropertyGroup>
<OptionInfer>On</OptionInfer>
</PropertyGroup>
<ItemGroup>
<Reference Include="IobManComm, Version=1.0.0.0, Culture=neutral, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\IobManComm.dll</HintPath>
</Reference>
<Reference Include="Microsoft.Bcl.AsyncInterfaces, Version=5.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\Microsoft.Bcl.AsyncInterfaces.dll</HintPath>
</Reference>
<Reference Include="Newtonsoft.Json, Version=13.0.0.0, Culture=neutral, PublicKeyToken=30ad4fe6b2a6aeed, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\Newtonsoft.Json.dll</HintPath>
</Reference>
<Reference Include="NLog, Version=4.0.0.0, Culture=neutral, PublicKeyToken=5120e14c03d0593c, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\NLog.dll</HintPath>
</Reference>
<Reference Include="Pipelines.Sockets.Unofficial, Version=1.0.0.0, Culture=neutral, PublicKeyToken=42ea0a778e13fbe2, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\Pipelines.Sockets.Unofficial.dll</HintPath>
</Reference>
<Reference Include="StackExchange.Redis, Version=2.0.0.0, Culture=neutral, PublicKeyToken=c219ff1ca8c2ce46, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\StackExchange.Redis.dll</HintPath>
</Reference>
<Reference Include="System" />
<Reference Include="System.Buffers, Version=4.0.3.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Buffers.dll</HintPath>
</Reference>
<Reference Include="System.Data" />
<Reference Include="System.Deployment" />
<Reference Include="System.Diagnostics.PerformanceCounter, Version=5.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Diagnostics.PerformanceCounter.dll</HintPath>
</Reference>
<Reference Include="System.Drawing" />
<Reference Include="System.IO.Compression, Version=4.1.2.0, Culture=neutral, PublicKeyToken=b77a5c561934e089, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.IO.Compression.dll</HintPath>
</Reference>
<Reference Include="System.IO.Pipelines, Version=5.0.0.1, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.IO.Pipelines.dll</HintPath>
</Reference>
<Reference Include="System.Memory, Version=4.0.1.1, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Memory.dll</HintPath>
</Reference>
<Reference Include="System.Numerics.Vectors, Version=4.1.4.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Numerics.Vectors.dll</HintPath>
</Reference>
<Reference Include="System.Runtime.CompilerServices.Unsafe, Version=4.0.4.1, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Runtime.CompilerServices.Unsafe.dll</HintPath>
</Reference>
<Reference Include="System.Runtime.InteropServices.RuntimeInformation, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Runtime.InteropServices.RuntimeInformation.dll</HintPath>
</Reference>
<Reference Include="System.Threading.Channels, Version=5.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Threading.Channels.dll</HintPath>
</Reference>
<Reference Include="System.Threading.Tasks.Extensions, Version=4.2.0.1, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51, processorArchitecture=MSIL">
<HintPath>..\packages\IobManComm.0.9.2210.2716\lib\System.Threading.Tasks.Extensions.dll</HintPath>
</Reference>
<Reference Include="System.Windows.Forms" />
<Reference Include="System.Xml" />
<Reference Include="System.Core" />
<Reference Include="System.Xml.Linq" />
<Reference Include="System.Data.DataSetExtensions" />
<Reference Include="System.Net.Http" />
</ItemGroup>
<ItemGroup>
<Import Include="Microsoft.VisualBasic" />
<Import Include="System" />
<Import Include="System.Collections" />
<Import Include="System.Collections.Generic" />
<Import Include="System.Data" />
<Import Include="System.Drawing" />
<Import Include="System.Diagnostics" />
<Import Include="System.Windows.Forms" />
<Import Include="System.Linq" />
<Import Include="System.Xml.Linq" />
<Import Include="System.Threading.Tasks" />
</ItemGroup>
<ItemGroup>
<Compile Include="Form1.vb">
<SubType>Form</SubType>
</Compile>
<Compile Include="Form1.Designer.vb">
<DependentUpon>Form1.vb</DependentUpon>
<SubType>Form</SubType>
</Compile>
<Compile Include="My Project\AssemblyInfo.vb" />
<Compile Include="My Project\Application.Designer.vb">
<AutoGen>True</AutoGen>
<DependentUpon>Application.myapp</DependentUpon>
</Compile>
<Compile Include="My Project\Resources.Designer.vb">
<AutoGen>True</AutoGen>
<DesignTime>True</DesignTime>
<DependentUpon>Resources.resx</DependentUpon>
</Compile>
<Compile Include="My Project\Settings.Designer.vb">
<AutoGen>True</AutoGen>
<DependentUpon>Settings.settings</DependentUpon>
<DesignTimeSharedInput>True</DesignTimeSharedInput>
</Compile>
</ItemGroup>
<ItemGroup>
<EmbeddedResource Include="Form1.resx">
<DependentUpon>Form1.vb</DependentUpon>
</EmbeddedResource>
<EmbeddedResource Include="My Project\Resources.resx">
<Generator>VbMyResourcesResXFileCodeGenerator</Generator>
<LastGenOutput>Resources.Designer.vb</LastGenOutput>
<CustomToolNamespace>My.Resources</CustomToolNamespace>
<SubType>Designer</SubType>
</EmbeddedResource>
</ItemGroup>
<ItemGroup>
<None Include="My Project\Application.myapp">
<Generator>MyApplicationCodeGenerator</Generator>
<LastGenOutput>Application.Designer.vb</LastGenOutput>
</None>
<None Include="My Project\Settings.settings">
<Generator>SettingsSingleFileGenerator</Generator>
<CustomToolNamespace>My</CustomToolNamespace>
<LastGenOutput>Settings.Designer.vb</LastGenOutput>
</None>
<None Include="App.config" />
<None Include="packages.config" />
</ItemGroup>
<Import Project="$(MSBuildToolsPath)\Microsoft.VisualBasic.targets" />
</Project>
@@ -0,0 +1,4 @@
<?xml version="1.0" encoding="utf-8"?>
<packages>
<package id="IobManComm" version="0.9.2210.2716" targetFramework="net462" />
</packages>