Update config x punzonatrici

This commit is contained in:
Samuele E. Locatelli
2018-11-28 18:15:21 +01:00
parent a6d708029a
commit 28d281153f
7 changed files with 134 additions and 5 deletions
+63
View File
@@ -0,0 +1,63 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE, isola Trevisan 424 con robot Kawasaki (NO industria 4.0)
CNCTYPE=SIEMENS
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape
[CNC]
IP=192.168.1.57
CPUTYPE=S71200
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
[BRANCH]
NAME=develop
+1 -1
View File
@@ -1,6 +1,6 @@
;Configurazione IOB-WIN
[IOB]
;ROBOT KAWASAKI, isola Trevisan 547
;ROBOT KAWASAKI 553, isola Trevisan 547
CNCTYPE=KAWASAKI
[MACHINE]
+63
View File
@@ -0,0 +1,63 @@
;Configurazione IOB-WIN
[IOB]
;Punzonatrice FAPE, isola Trevisan 547
CNCTYPE=SIEMENS
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape
[CNC]
IP=192.168.1.55
CPUTYPE=S71200
RACK=0
SLOT=0
[SERVER]
MPIP=http://192.168.1.64
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB15.DBB0
ADDR_WRITE=DB16.DBB0
SIZE_READ=48
SIZE_WRITE=48
;BIT0=CONN
BIT1=DB15.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
BIT3=DB15.DBB3
BIT4=DB15.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB15.DBDW40
;PZ_CAD_MADDR=1602
;PZ_REQ_MADDR=1603
;PZ_DONE_MADDR=1604
;PZ_GTOT_MADDR=1605
[BRANCH]
NAME=develop
+2 -2
View File
@@ -1,5 +1,6 @@
;Configurazione IOB-WIN
[IOB]
[IOB]
;Punzonatrice FAPE, isola BTB1
CNCTYPE=SIEMENS
PING_MS_TIMEOUT=500
@@ -8,7 +9,6 @@ VENDOR=Tecnomeccanica
MODEL=Punzonatrice Fape
[CNC]
; Siemens (FAPE) isola BTB1
IP=192.168.1.56
CPUTYPE=S71200
RACK=0
+1 -1
View File
@@ -26,7 +26,7 @@ CMDIOB2CALL=/IOB/getIob2call?GWIP=
;--- SIEMENS TORRI ---
;STARTLIST=3013
;--- LVF
STARTLIST=GT547
STARTLIST=GT547,GT554,GT557
MAXCNC=4
;STARTLIST=3001,3002,3003,3004,3005
+3
View File
@@ -223,6 +223,9 @@
<None Include="DATA\CONF\3001.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\GT554.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\GT557.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
Vendored
+1 -1
View File
@@ -16,7 +16,7 @@ pipeline {
/* calcolo numero versione... diverso x branch MASTER/DEVELOP */
script {
withEnv(['NEXT_BUILD_NUMBER=314']) {
withEnv(['NEXT_BUILD_NUMBER=315']) {
// env.versionNumber = VersionNumber(versionNumberString : '1.18.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true)
env.versionNumber = VersionNumber(versionNumberString : '1.18.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true, overrideBuildsAllTime: '${NEXT_BUILD_NUMBER}')
env.APP_NAME = 'MAPO-IOB-WIN'