Aggiunto bozza confparametri IOB centerfrigo

This commit is contained in:
Samuele Locatelli
2022-06-21 16:43:44 +02:00
parent 448375b234
commit 0e6a034cf4
5 changed files with 149 additions and 0 deletions
@@ -0,0 +1,76 @@
;Configurazione IOB-WIN
[IOB]
;Impianto Cedax di Turi (test) - Giacovelli
CNCTYPE=MODBUS_TCP_CENTERFRIGO
PING_MS_TIMEOUT=1000
[MACHINE]
VENDOR=Centerfrigo
MODEL=Impianto Turi
[CNC]
IP=192.168.4.161
PORT=502
[SERVER]
MPIP=http://192.168.1.14
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=40001
ADDR_WRITE=41000
SIZE_READ=2400
SIZE_WRITE=0
HR_BASE_ADDR=40002
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
PZCOUNT_MODE=STD.DB85.DBRE16
DISABLE_PZCOUNT=TRUE
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
; GEST DATI DYN
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
; gestione delta minimo accettabile tra min/MAX
DELTA_VAL=0.1
; clock base (da 10ms)
timerIntMs=10
; conf parametri memoria READ/WRITE
PARAM_CONF=GIACO_CENTERFRIGO.json
NO_PING=TRUE
; conf blocchi memoria x READ
MEM_BLOCK=GIACO_CENTERFRIGO_MBlock.json
; conf aree allarme
ALARM_CONF=GIACO_CENTERFRIGO_alarm.json
; rimozione check limiti min/max dynData
disDynDataRangeCheck=true
[BRANCH]
NAME=master
@@ -0,0 +1,20 @@
{
"mMapWrite": {
},
"mMapRead": {
"TempTunnel": {
"name": "TempTunnel",
"description": "Temperatura Tunne",
"memAddr": "41520",
"tipoMem": "Real",
"index": 1520,
"size": 2,
"func": "MEDIAN",
"period": 90,
"factor": 1,
"minVal": -100,
"maxVal": 100,
"unit": "C"
}
}
}
@@ -0,0 +1,22 @@
{
"ReadBlocks": {
"41060": 4,
"41300": 4,
"41500": 64,
"41650": 64,
"41800": 48,
"41920": 48,
"42040": 48,
"42160": 8,
"42290": 48,
"42410": 64,
"42540": 48,
"42660": 64,
"42790": 48,
"42910": 48,
"43040": 48,
"43160": 48,
"43280": 48,
"43400": 4
}
}
@@ -0,0 +1,27 @@
[
{
"description": "Allarmi Tunnel",
"tipoMem": "DInt",
"memAddr": "41654",
"index": 1654,
"size": 2,
"messages": [
"ALLARME ALTA TEMPERATURA AMBIENTE TUNNEL",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##",
"##"
]
}
]
+4
View File
@@ -284,6 +284,10 @@
<None Include="DATA\CONF\1033.ini">
<CopyToOutputDirectory>Always</CopyToOutputDirectory>
</None>
<None Include="DATA\CONF\GIACO_CENTERFRIGO_MBlock.json" />
<None Include="DATA\CONF\GIACO_CENTERFRIGO_alarm.json" />
<None Include="DATA\CONF\GIACO_CENTERFRIGO.ini" />
<None Include="DATA\CONF\GIACO_CENTERFRIGO.json" />
<None Include="DATA\CONF\GIACO_ICOEL_002.json">
<CopyToOutputDirectory>PreserveNewest</CopyToOutputDirectory>
</None>