Compare commits

...

2 Commits

Author SHA1 Message Date
andrea.villa bec18b1cc3 - Allineamento con common ver. 2.7b5
- Aggiunta lettura parametro MAXFEEDPINZE
2025-02-27 09:37:13 +01:00
luca.mazzoleni 2e46fc36c7 - in BeamData GetSetupInfo modificate informazioni teste 2025-02-25 18:09:20 +01:00
5 changed files with 21 additions and 17 deletions
+12 -12
View File
@@ -229,34 +229,34 @@ local function GetSetupInfo( sHead)
-- testa 5 assi da sopra
if sHead == 'H11' then
SetupInfo.bIsTopHead = true
SetupInfo.bIsBottomHead = not SetupInfo.bIsTopHead
SetupInfo.HeadType = { bTop = true, bBottom = false}
SetupInfo.PreferredSide = {}
SetupInfo.dMaxNegativeAngle = sin( -35)
-- lama su aggregato testa 5 assi da sopra
elseif sHead == 'H12' then
SetupInfo.bIsTopHead = true
SetupInfo.bIsBottomHead = not SetupInfo.bIsTopHead
SetupInfo.HeadType = { bTop = true, bBottom = false}
SetupInfo.PreferredSide = {}
SetupInfo.dMaxNegativeAngle = sin( -35)
-- seconda lama su aggregato testa 5 assi da sopra
elseif sHead == 'H16' then
SetupInfo.bIsTopHead = true
SetupInfo.bIsBottomHead = not SetupInfo.bIsTopHead
SetupInfo.HeadType = { bTop = true, bBottom = false}
SetupInfo.PreferredSide = {}
SetupInfo.dMaxNegativeAngle = sin( -35)
-- motosega
elseif sHead == 'H13' then
SetupInfo.bIsTopHead = true
SetupInfo.bIsBottomHead = not SetupInfo.bIsTopHead
SetupInfo.HeadType = { bTop = true, bBottom = false}
SetupInfo.PreferredSide = {}
SetupInfo.dMaxNegativeAngle = 0
SetupInfo.dZSafeDelta = 60
-- testa 5 assi da sotto
elseif sHead == 'H21' then
SetupInfo.bIsBottomHead = true
SetupInfo.bIsTopHead = not SetupInfo.bIsBottomHead
SetupInfo.HeadType = { bTop = false, bBottom = true}
SetupInfo.PreferredSide = {}
SetupInfo.dMaxPositiveAngle = sin( 25)
-- lama su aggregato testa 5 assi da sotto
elseif sHead == 'H22' then
SetupInfo.bIsBottomHead = true
SetupInfo.bIsTopHead = not SetupInfo.bIsBottomHead
SetupInfo.HeadType = { bTop = false, bBottom = true}
SetupInfo.PreferredSide = {}
SetupInfo.dMaxPositiveAngle = sin( 25)
end
+1 -1
View File
@@ -28,7 +28,7 @@ function OnStart()
--EMT.LINEINC = 1 -- incremento numerazione linee
--EMT.Ft = 'F' -- token per feed
--EMT.St = 'S' -- token per speed
EMT.FMAXPINZE = 116000 -- feed massima pinze
EMT.FMAXPINZE = EgtClamp( MaxFeedPinze or 116000, 20000, 116000) -- feed massima pinze
SetToParkLine() -- si inizia con linee da parcheggiare su stack
end
+3 -2
View File
@@ -8,8 +8,8 @@
require( 'EmtGenerator')
EgtEnableDebug( false)
PP_VER = '2.7b3'
PP_NVER = '2.7.2.3'
PP_VER = '2.7b5'
PP_NVER = '2.7.2.5'
MIN_MACH_VER = '2.5k1'
MACH_NAME = 'Essetre-PF1250MAX'
@@ -238,6 +238,7 @@ if EgtExistsFile( sDataBeam) then
if Machine.Offsets.DEFTCPOS2 then DefTcPos2 = ( 'T' .. Machine.Offsets.DEFTCPOS2) end
if Machine.Offsets.MINPRESS then MinForzaPinze = Machine.Offsets.MINPRESS end
if Machine.Offsets.MAXPRESS then MaxForzaPinze = Machine.Offsets.MAXPRESS end
if Machine.Offsets.MAXFEEDPINZE then MaxFeedPinze = Machine.Offsets.MAXFEEDPINZE end
if Machine.Offsets.CHIUDI_PINZE_2_3_SCAMBIO then ForceToCloseRollersGate = Machine.Offsets.CHIUDI_PINZE_2_3_SCAMBIO == 1 end
if Machine.Offsets.WOOD_DENSITY then WoodDensity = Machine.Offsets.WOOD_DENSITY end
if Machine.Offsets.MOTORS23KW then Motors23KW = Machine.Offsets.MOTORS23KW == 1 end
+4 -1
View File
@@ -1,5 +1,8 @@
==== Common_PF1250 Update Log ====
Versione 2.7b5 (26/02/2025)
- (MLDE-GEN) Gestione lettura feed massima pinze da Ts3.
Versione 2.7b4 (21/02/2025)
- (SIM-GEN) Ripristinato comportamento precedente calcolo posizione dei rulli di pinzaggio fatto con 2.7b2.
- (MLDE-SIM) Gestione aggregato flottante. Serve modifica MLDE. Ticket#2297
@@ -11,7 +14,7 @@ Versione 2.7b2 (04/02/2025)
- (SIM-GEN) Piccola modifica nel calcolo posizione dei rulli di pinzaggio.
Versione 2.7b1 (03/02/2025)
- (SIM) Corretta simulazioen che non mandava testa in home in caso di utensile lungo. Generazione era già ok. Ticket#2280
- (SIM) Corretta simulazione che non mandava testa in home in caso di utensile lungo. Generazione era già ok. Ticket#2280
Versione 2.7a2 (28/01/2025)
- (SIM-GEN) In MLSE aggiunta piccola correzione quota Z in caso di direzione Z tra 0.5 e 0.707.
+1 -1
View File
@@ -3,7 +3,7 @@
local InfoCommon_STD_PP = {
NAME = 'Common_PF1250', -- nome script PP standard
VERSION = '2.7b4', -- versione script
VERSION = '2.7b5', -- versione script
MIN_MACH_VER_PP_COMMON = '2.5k1' -- versione minima kernel
}