Compare commits

..

2 Commits

Author SHA1 Message Date
Nicola Pievani a6890f804a Merge commit '9b89b68684e2d64b043ac6572b75b1cfc0d1515c' 2023-12-27 15:56:21 +01:00
Nicola Pievani bdc22318dc Merge commit '0c1e26754044a0d95d7e80de38d91aca9904a894' 2023-10-02 15:16:33 +02:00
5 changed files with 10 additions and 49 deletions
+4 -14
View File
@@ -3588,14 +3588,9 @@ Public Class Assembly
If Not bRabbet Then
'Map.refPartPageVM.CurrPart = Jamb
CurrCompo = Jamb.AddNewCompo(Map.refCompoPanelVM.CompoTypeList(IndexCompoPanel), True)
If Not IsNothing(CurrCompo) Then
DirectCast(CurrCompo.CompoParamList(0), ComboBoxParam).SelItem = DirectCast(CurrCompo.CompoParamList(0), ComboBoxParam).ItemList(0)
Else
' 50180=Warning : {0} does not exist.
MessageBox.Show(String.Format(EgtMsg(50180), Map.refCompoPanelVM.CompoTypeList(IndexCompoPanel).Name & ".frame"), EgtMsg(50101), MessageBoxButton.OK, MessageBoxImage.Error)
End If
DirectCast(CurrCompo.CompoParamList(0), ComboBoxParam).SelItem = DirectCast(CurrCompo.CompoParamList(0), ComboBoxParam).ItemList(0)
Else
CurrCompo = Jamb.CompoList(IndexCompo)
CurrCompo = Jamb.CompoList(IndexCompo)
End If
' mofico la componete rabbet
If Not IsNothing(CurrCompo) Then
@@ -3734,14 +3729,9 @@ Public Class Assembly
If Not bRabbet Then
' lo aggiungo
Local_Compo = Jamb.AddNewCompo(Map.refCompoPanelVM.CompoTypeList(CompoListIndex), True)
If Not IsNothing(Local_Compo) Then
DirectCast(Local_Compo.CompoParamList(0), ComboBoxParam).SetSelItem(DirectCast(Local_Compo.CompoParamList(0), ComboBoxParam).ItemList(nIndexSide))
Else
' 50180=Warning : {0} does not exist.
MessageBox.Show(String.Format(EgtMsg(50180), Map.refCompoPanelVM.CompoTypeList(CompoListIndex).Name & ".frame"), EgtMsg(50101), MessageBoxButton.OK, MessageBoxImage.Error)
End If
DirectCast(Local_Compo.CompoParamList(0), ComboBoxParam).SetSelItem(DirectCast(Local_Compo.CompoParamList(0), ComboBoxParam).ItemList(nIndexSide))
Else
Local_Compo = Jamb.CompoList(IndexCompo)
Local_Compo = Jamb.CompoList(IndexCompo)
End If
If Not IsNothing(Local_Compo) Then
Dim dVal1 As Double = 0
+1 -1
View File
@@ -1876,7 +1876,7 @@ Public Class Hardware
' cerco un numero finito di parametri
For IndexParam As Integer = 0 To IndexParamDDF - 1
If LineIndex + ParamIndex > sFile.Count - 1 Then Return False
' recupero il nome del parametro
' recuro il nome del parametro
KeyParam = Trim(RegexFunction.KeyParamLine(sFile(LineIndex + ParamIndex)))
While String.IsNullOrEmpty(KeyParam) And LineIndex + ParamIndex < sFile(LineIndex + ParamIndex).Count
ParamIndex += 1
+2 -2
View File
@@ -57,8 +57,8 @@ Friend Class MainWindowModel
EgtUILib.GetPrivateProfileString(S_LICENCE, K_KEY, "", sKey, sLicFile)
EgtSetKey(sKey)
' Recupero livello e opzioni della chiave
Dim bKey As Boolean = EgtGetKeyLevel(3279, 2604, 1, IniFile.m_nKeyLevel) And
EgtGetKeyOptions(3279, 2604, 1, IniFile.m_nKeyOptions)
Dim bKey As Boolean = EgtGetKeyLevel(3279, 2512, 1, IniFile.m_nKeyLevel) And
EgtGetKeyOptions(3279, 2512, 1, IniFile.m_nKeyOptions)
'Inizializzazione generale di EgtInterface
m_nDebug = GetMainPrivateProfileInt(S_GENERAL, K_DEBUG, 0)
Dim sLogFile As String = IniFile.m_sTempDir & "\" & GENLOG_FILE_NAME.Replace("#", m_nInstance.ToString())
+2 -2
View File
@@ -72,5 +72,5 @@ Imports System.Windows
' by using the '*' as shown below:
' <Assembly: AssemblyVersion("1.0.*")>
<Assembly: AssemblyVersion("2.6.4.1")>
<Assembly: AssemblyFileVersion("2.6.4.1")>
<Assembly: AssemblyVersion("2.5.12.2")>
<Assembly: AssemblyFileVersion("2.5.12.2")>
+1 -30
View File
@@ -304,32 +304,7 @@ Public Module Utility
Return "0.0000"
End If
End Select
ElseIf sValue.Contains("(") And sValue.Contains(")") And sValue.Contains("mm") Then
sValue = Trim(sValue.Replace("mm", ""))
If sValue.StartsWith("(") And sValue.EndsWith(")") Then
Dim ArrayString() As Char = StringToChar(sValue)
ArrayString(0) = CChar("§")
ArrayString(ArrayString.Count - 1) = CChar("§")
sValue = CharToString(ArrayString, sValue)
sValue = Trim(sValue.Replace("§", ""))
End If
If String.IsNullOrEmpty(sValue) Then Return "0.0000"
' ricevo un valore in inches
Select Case OptionModule.m_SelectedMeasureUnit
Case ConstGen.MM ' se la configurazione è inches non faccio conversioni
If StringToDouble(sValue, dVal) Then
Return sValue
Else
Return "0.0000"
End If
Case ConstGen.VAL_INCHES ' se la configurazione è in mm faccio la conevrsione
If MmToInches(sValue) Then
Return sValue
Else
Return "0.0000"
End If
End Select
ElseIf sValue.Contains("(") And sValue.Contains(")") And (Not sValue.Contains("inch") Or Not sValue.Contains("mm")) Then
ElseIf sValue.Contains("(") And sValue.Contains(")") And Not sValue.Contains("inch") Then
'sValue = Regex.Match(sValue, "\s*\((.*?)\s*\)\s*\.*").Groups(1).Value
If String.IsNullOrEmpty(sValue) Then Return "0.0000"
' ricevo un valore in mm
@@ -404,10 +379,6 @@ Public Module Utility
' non eseguo nessun tipo di conversione
Return True
Else
' la configurazione è già in mm quindi non devo convertire
If OptionModule.m_IsMM Then
Return True
End If
Return InchesToMm(sMeasure)
End If
Return False