Corretto emissione movimento ZMAX con EMT.FLAG =5

This commit is contained in:
andrea.villa
2024-09-24 17:40:56 +02:00
parent b50c4ef806
commit 3ef4c18fe6
6 changed files with 24 additions and 6 deletions
+6 -1
View File
@@ -649,7 +649,7 @@ function OnRapid()
local sES = ' ES'..EgtNumToString( EMT.S, 0)
-- se carico motosega, ruoto in zona sicura prima di approcciare la lavorazione
if EMT.HEAD == 'H3' and EMT.ST > BeamHeightForFixRot and EMT.FLAG2 == 1 then
if ( EMT.HEAD == 'H3' or ( bZmax and EMT.TTOTLEN > 200)) and EMT.ST > BeamHeightForFixRot and EMT.FLAG2 == 1 then
local sEEPreMove = ' EE' .. EgtIf( bZmax, '3', '4')
local sOutPreMove = 'G101' .. ' X' .. EmtLenToString( -SafeXRotAxes, 3) .. ' Z' .. EmtLenToString( MyZHome, 3) ..
EmtGetAxis( 'R2') .. EmtGetAxis( 'R1') .. sEE .. sEL .. sER .. sET .. sES
@@ -838,6 +838,11 @@ function OnRapid()
-- non previsto
-- se altrimenti rotazione a Z max per lavorazione successiva
elseif EMT.FLAG == 5 then
EMT.REFLOC = nil
EMT.IPLGL = false
MyAdjustLinearAxes()
EmtAdjustRotaryAxes()
EmtResetPrev()
-- ricavo i dati per la lavorazione
local sEE = ' EE3'
local sEL = ' EL' .. EmtLenToString( EgtIf( EMT.HEAD ~= 'H3', EMT.TLEN, ( EMT.TDIST or ChSawLen)), 3)
+6 -1
View File
@@ -713,7 +713,7 @@ function OnRapid()
local sES = ' ES'..EgtNumToString( EMT.S, 0)
-- se carico motosega, ruoto in zona sicura prima di approcciare la lavorazione
if EMT.HEAD == 'H3' and EMT.ST > BeamHeightForFixRot and EMT.FLAG2 == 1 then
if ( EMT.HEAD == 'H3' or ( bZmax and EMT.TTOTLEN > 200)) and EMT.ST > BeamHeightForFixRot and EMT.FLAG2 == 1 then
local sEEPreMove = ' EE' .. EgtIf( bZmax, '3', '4')
local sOutPreMove = 'G101' .. ' X' .. EmtLenToString( -SafeXRotAxes, 3) .. ' Z' .. EmtLenToString( MyZHome, 3) ..
EmtGetAxis( 'R2') .. EmtGetAxis( 'R1') .. sEE .. sEL .. sER .. sET .. sES
@@ -912,6 +912,11 @@ function OnRapid()
-- non previsto
-- se altrimenti rotazione a Z max per lavorazione successiva
elseif EMT.FLAG == 5 then
EMT.REFLOC = nil
EMT.IPLGL = false
MyAdjustLinearAxes()
EmtAdjustRotaryAxes()
EmtResetPrev()
-- ricavo i dati per la lavorazione
local sEE = ' EE3'
local sEL = ' EL' .. EmtLenToString( EgtIf( EMT.HEAD ~= 'H3', EMT.TLEN, ( EMT.TDIST or ChSawLen)), 3)
+6 -1
View File
@@ -663,7 +663,7 @@ function OnRapid()
end
-- se carico motosega, ruoto in zona sicura prima di approcciare la lavorazione
if EMT.HEAD == 'H3' and EMT.ST > BeamHeightForFixRot and EMT.FLAG2 == 1 then
if ( EMT.HEAD == 'H3' or ( bZmax and EMT.TTOTLEN > 200)) and EMT.ST > BeamHeightForFixRot and EMT.FLAG2 == 1 then
local sOutPreMove = 'M101 P1=1' .. ' P2=' .. EmtLenToString( -SafeXRotAxes, 3) .. ' P3=' .. EmtLenToString( MyZHome, 3) ..
' P4=' .. EgtNumToString( EMT.R2, 3) .. ' P5=' .. EgtNumToString( EMT.R1, 3) ..
' P6=' .. AdjustTcPos( false) .. ' P7=' .. EgtNumToString( EMT.S, 0) ..
@@ -854,6 +854,11 @@ function OnRapid()
-- non previsto
-- se altrimenti rotazione a Z max per lavorazione successiva
elseif EMT.FLAG == 5 then
EMT.REFLOC = nil
EMT.IPLGL = false
MyAdjustLinearAxes()
EmtAdjustRotaryAxes()
EmtResetPrev()
local sOut = 'M101 P1=1' .. ' P2=' .. EmtLenToString( EMT.L2, 3) .. ' P3=' .. EmtLenToString( EMT.L3, 3) ..
' P4=' .. EgtNumToString( EMT.R2, 3) .. ' P5=' .. EgtNumToString( EMT.R1, 3) ..
' P6=' .. AdjustTcPos( false) .. ' P7=' .. EgtNumToString( EMT.S, 0) ..
+4 -1
View File
@@ -662,6 +662,7 @@ function OnSimulMachiningEnd()
EMT.FALL = false
end
EMT.PREVHEAD = EMT.HEAD
EMT.PREVTOOL = EMT.TOOL
EMT.PREVEXIT = EMT.EXIT
end
@@ -749,10 +750,12 @@ function OnSimulMoveStart()
if EMT.MCHFIRST then
EgtOutText( '')
EMT.MCHFIRST = false
local bZmax = ( EMT.TOOL ~= EMT.PREVTOOL or EMT.L3 > -1)
-- con pezzi alti aggiorno gli assi rotanti prima di muovermi sopra il pezzo
if not EMT.LOAD and EMT.MOVE == 0 and EMT.HB > BeamHeightForFixRot and EMT.FLAG2 == 1 then
-- se motosega mi muovo a X di sicurezza per ruotare
if EMT.HEAD == 'H3' then
if ( EMT.HEAD == 'H3' or ( bZmax and EMT.TOTLEN > 200)) then
SimulMoveAxes( 'X', SafeXRotAxes, MCH_SIM_STEP.RAPID, 'C', EMT.R1, MCH_SIM_STEP.COLLROT, 'B', EMT.R2, MCH_SIM_STEP.COLLROT)
end
end
+1 -1
View File
@@ -1,6 +1,6 @@
==== Common_FAST Update Log ====
Versione 2.6-- (--/--/2024)
Versione 2.6i5 (24/09/2024)
- (SIM-GEN) Tolto controllo su lunghezza maggiore di 200mm introdotto con 2.6i2 perchè non completamente funzionante
- (GEN) Gestione in OnRapid() di EMT.FLAG=5 (rotazione a Z max per lavorazione successiva). Ora allineata alla simulazione
+1 -1
View File
@@ -3,7 +3,7 @@
local InfoCommon_STD_PP = {
NAME = 'Common_FAST', -- nome script PP standard
VERSION = '2.6--', -- versione script
VERSION = '2.6i5', -- versione script
MIN_MACH_VER_PP_COMMON = '2.5k1' -- versione minima kernel
}