update alarm list fanuc
alcune modifiche file XML x CMS
This commit is contained in:
+7
-73
@@ -10,9 +10,8 @@
|
||||
<DataItem category="SAMPLE" id="ACC_TIME" name="Tempo macchina ON" type="ACCUMULATED_TIME"/>
|
||||
<DataItem category="SAMPLE" id="ACC_TIME_WORK" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
|
||||
<DataItem category="SAMPLE" id="CLOCK" type="CLOCK_TIME"/>
|
||||
<DataItem category="EVENT" id="POWER" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="POWER" type="POWER_STATE"/>
|
||||
<DataItem category="EVENT" id="OperatorId" type="MESSAGE"/>
|
||||
<!--<DataItem category="EVENT" id="FUNCT_MODE" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="USER_ACTION" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="TESTING_DATA" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="PROTECTION_STATUS" type="MESSAGE"/>
|
||||
@@ -26,92 +25,60 @@
|
||||
<Components>
|
||||
<Linear id="Axis_01" name="Asse X">
|
||||
<DataItems>
|
||||
<!-- descrizione, es "X" che POTREBBE cambiare -->
|
||||
<!--<DataItem category="EVENT" id="Axis_01_Descr" type="MESSAGE"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_01_PosAct" name="Pos asse X (1) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_PosTgt" name="Pos asse X (1) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_Load" name="Load asse X (1)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!--<DataItem category="EVENT" id="Axis_01_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_01_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_01_MastId" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="Axis_01_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_FeedAct" name="FEEDRATE Asse X (1)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_FeedOver" name="FEEDRATE OVERRIDE Asse X (1)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_01_AccTime" name="Tempo impiego cumulato asse X (1)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_InvDDone" name="Num cambi direzione asse X (1)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<!--<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />-->
|
||||
<DataItem category="CONDITION" id="Axis_01_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_01_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_02" name="Asse Y">
|
||||
<DataItems>
|
||||
<!-- descrizione, es "Asse Y (2)" che POTREBBE cambiare -->
|
||||
<!--<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_02_PosAct" name="Pos asse Y (2) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_PosTgt" name="Pos asse Y (2) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_Load" name="Load asse Y (2)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!--<DataItem category="EVENT" id="Axis_02_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_02_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_02_MastId" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="Axis_02_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_FeedAct" name="FEEDRATE Asse Y (2)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_FeedOver" name="FEEDRATE OVERRIDE Asse Y (2)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_02_AccTime" name="Tempo impiego cumulato asse Y (2)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_InvDDone" name="Num cambi direzione asse Y (2)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<!--<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />-->
|
||||
<DataItem category="CONDITION" id="Axis_02_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_02_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_03" name="Asse Z">
|
||||
<DataItems>
|
||||
<!-- descrizione, es "Asse Z (3)" che POTREBBE cambiare -->
|
||||
<!--<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_03_PosAct" name="Pos asse Z (3) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_PosTgt" name="Pos asse Z (3) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_Load" name="Load asse Z (3)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!--<DataItem category="EVENT" id="Axis_03_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_03_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_03_MastId" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="Axis_03_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_FeedAct" name="FEEDRATE Asse Z (3)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_FeedOver" name="FEEDRATE OVERRIDE Asse Z (3)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_03_AccTime" name="Tempo impiego cumulato asse Z (3)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_InvDDone" name="Num cambi direzione asse X (3)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<!--<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />-->
|
||||
<DataItem category="CONDITION" id="Axis_03_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_03_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_06" name="Asse U">
|
||||
<DataItems>
|
||||
<!-- Descrizione, es "U" che POTREBBE cambiare se si sposta di path -->
|
||||
<!--<DataItem category="EVENT" id="Axis_06_Descr" type="MESSAGE"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_06_PosAct" name="Pos asse U (6) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_PosTgt" name="Pos asse U (6) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_Load" name="Load asse U (6)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!--<DataItem category="EVENT" id="Axis_06_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_06_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_06_MastId" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="Axis_06_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_FeedAct" name="FEEDRATE Asse U (6)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_FeedOver" name="FEEDRATE OVERRIDE Asse U (6)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_06_AccTime" name="Tempo impiego cumulato asse U (6)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_InvDDone" name="Num cambi direzione asse U (6)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<!--<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />-->
|
||||
<DataItem category="CONDITION" id="Axis_06_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_06_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
@@ -121,15 +88,10 @@
|
||||
<DataItem category="SAMPLE" id="Axis_04_PosAct" name="Pos asse J (4) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_PosTgt" name="Pos asse J (4) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_Load" name="Load asse J (4)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!--<DataItem category="EVENT" id="Axis_04_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_04_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_04_MastId" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="Axis_04_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_FeedAct" name="ROT SPEED Asse J (4)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_FeedOver" name="ROT SPEED OVERRIDE Asse J (4)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_04_AccelAct" name="Accelerazione angolare asse J (4)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_04_AccTime" name="Tempo impiego cumulato asse J (4)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_04_DistDone" name="Num Giri asse J (4) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_InvDDone" name="Num cambi direzione asse J (4)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="CONDITION" id="Axis_04_AlarmCNC" type="SYSTEM"/>
|
||||
@@ -141,15 +103,10 @@
|
||||
<DataItem category="SAMPLE" id="Axis_05_PosAct" name="Pos asse K (5) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_PosTgt" name="Pos asse K (5) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_Load" name="Load asse K (5)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!--<DataItem category="EVENT" id="Axis_05_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_05_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_05_MastId" type="MESSAGE"/>-->
|
||||
<DataItem category="EVENT" id="Axis_05_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_FeedAct" name="ROT SPEED Asse K (5)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_FeedOver" name="ROT SPEED OVERRIDE Asse K (5)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_05_AccelAct" name="Accelerazione angolare asse K (5)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_05_AccTime" name="Tempo impiego cumulato asse K (5)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<!--<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
|
||||
<DataItem category="SAMPLE" id="Axis_05_DistDone" name="Num Giri asse k (5) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_InvDDone" name="Num cambi direzione asse K (5)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="CONDITION" id="Axis_05_AlarmCNC" type="SYSTEM"/>
|
||||
@@ -167,7 +124,6 @@
|
||||
<Path id="Path_01" name="Path 01">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Path_01_Type" type="MESSAGE"/>
|
||||
<!--<DataItem category="EVENT" id="Path_01_ActiveAxes" type="ACTIVE_AXES"/>-->
|
||||
<DataItem category="EVENT" id="Path_01_CodG_Act" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_SubMode" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_PartId" type="PART_ID"/>
|
||||
@@ -188,12 +144,11 @@
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActI" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo I"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActJ" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo J"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActK" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo K"/>
|
||||
<DataItem category="CONDITION" id="Path_01_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Path_01_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Path_01_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Path_01_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Path>
|
||||
<!-- probabilmente da ri-spostare sotto PATH... -->
|
||||
<Actuator id="UniOp_01" name ="Unità Operatrice 01">
|
||||
<Actuator id="UniOp_01" name ="Unita Operatrice 01">
|
||||
<DataItems>
|
||||
<DataItem category="SAMPLE" id="UnOp_01_Speed" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="UnOp Speed"/>
|
||||
<DataItem category="SAMPLE" id="UnOp_01_SpeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="UnOp SPEED Override"/>
|
||||
@@ -203,26 +158,13 @@
|
||||
<DataItem category="EVENT" id="UnOp_01_VitaRes" name="Vita Residua Tool" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category = "EVENT" id = "UnOp_01_VitaResType" name = "Tipologia misura Vita Residua Tool" type = "MESSAGE" />
|
||||
<DataItem category="SAMPLE" id="UnOp_01_Load" name="Load sul PATH/UnOp" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!-- cambiare in event... -->
|
||||
<DataItem category="SAMPLE" id="UnOp_01_AccTime" name="Totale giri (migliaia) accumulati dal mandrino" type="COUNT"/>
|
||||
<DataItem category="EVENT" id="UnOp_01_AccTime" name="Totale giri (migliaia) accumulati dal mandrino" type="COUNT"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
</Components>
|
||||
</Controller>
|
||||
<Systems id="systems" name="systems">
|
||||
<Components>
|
||||
<Electric id="el" name="electric">
|
||||
<DataItems>
|
||||
<!--<DataItem category="EVENT" id="p2" name="power" type="POWER_STATE"/>-->
|
||||
</DataItems>
|
||||
</Electric>
|
||||
<Hydraulic id="hsys" name="hydraulic">
|
||||
<!--<DataItems>
|
||||
<DataItem category="CONDITION" id="hlow" type="LEVEL"/>
|
||||
<DataItem category="CONDITION" id="hpres" type="PRESSURE"/>
|
||||
<DataItem category="CONDITION" id="htemp" type="TEMPERATURE"/>
|
||||
</DataItems>-->
|
||||
</Hydraulic>
|
||||
<Pneumatic id="PneumSys" name="Pneumatic Systems">
|
||||
<Actuator id="VacPump_01" name ="Pompa 1">
|
||||
<DataItems>
|
||||
@@ -248,12 +190,6 @@
|
||||
</Actuator>
|
||||
</Pneumatic>
|
||||
<Coolant id="cool" name="coolant">
|
||||
<!--<DataItems>
|
||||
<DataItem category="CONDITION" id="clow" type="LEVEL"/>
|
||||
<DataItem category="CONDITION" id="coolpres" type="PRESSURE"/>
|
||||
<DataItem category="CONDITION" id="filter" type="x:FILTER"/>
|
||||
<DataItem category="CONDITION" id="coolantmotor" type="ACTUATOR"/>
|
||||
</DataItems>-->
|
||||
<Actuator id="Cooler_01" name ="Cooler 1">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Cooler_01_Status" name="Stato Cooler 1" type="ACTUATOR_STATE"/>
|
||||
@@ -281,13 +217,11 @@
|
||||
</Systems>
|
||||
<Sensor id="sens1" name="Sensorunit">
|
||||
<DataItems>
|
||||
<!-- verificare di poterli spostare e siano 4, 1 x ogni asse lineare >>> SPOSTARE!!!!!! -->
|
||||
<!-- <DataItem type="TEMPERATURE" id="Temp_04_Value" category="SAMPLE" name="Sonda Temperatura 4" units="DEGREE"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_05_Value" category="SAMPLE" name="Sonda Temperatura 5" units="DEGREE"/> -->
|
||||
<DataItem type="PRESSURE" id="Press_01_Value" category="SAMPLE" name="Pressostato 1" units="PASCAL"/>
|
||||
<DataItem type="PRESSURE" id="Press_02_Value" category="SAMPLE" name="Pressostato 2" units="PASCAL"/>
|
||||
</DataItems>
|
||||
</Sensor>
|
||||
</Components>
|
||||
</Device>
|
||||
</Devices>
|
||||
</MTConnectDevices>
|
||||
</MTConnectDevices>
|
||||
@@ -10,7 +10,7 @@
|
||||
<DataItem category="SAMPLE" id="ACC_TIME" name="Tempo macchina ON" type="ACCUMULATED_TIME"/>
|
||||
<DataItem category="SAMPLE" id="ACC_TIME_WORK" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
|
||||
<DataItem category="SAMPLE" id="CLOCK" type="CLOCK_TIME"/>
|
||||
<DataItem category="SAMPLE" id="POWER" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="POWER" type="POWER_STATE"/>
|
||||
<DataItem category="EVENT" id="OperatorId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="FUNCT_MODE" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="USER_ACTION" type="MESSAGE"/>
|
||||
@@ -40,11 +40,11 @@
|
||||
<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_AccTime" name="Tempo impiego cumulato asse X (1)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="METER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_InvDDone" name="Num cambi direzione asse X (1)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="AX01_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="AX01_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Axis_01_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_01_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_02" name="Asse Y">
|
||||
@@ -63,11 +63,11 @@
|
||||
<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_AccTime" name="Tempo impiego cumulato asse Y (2)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="METER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_InvDDone" name="Num cambi direzione asse Y (2)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="AX02_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="AX02_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Axis_02_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_02_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_03" name="Asse Z">
|
||||
@@ -86,11 +86,11 @@
|
||||
<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_AccTime" name="Tempo impiego cumulato asse Z (3)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="METER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_InvDDone" name="Num cambi direzione asse X (3)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="AX03_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="AX03_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Axis_03_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_03_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_06" name="Asse U">
|
||||
@@ -109,11 +109,11 @@
|
||||
<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_AccTime" name="Tempo impiego cumulato asse U (6)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="METER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_InvDDone" name="Num cambi direzione asse U (6)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="AX06_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="AX06_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Axis_06_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_06_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Rotary id="Axis_04" name="Asse B">
|
||||
@@ -132,8 +132,8 @@
|
||||
<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_DistDone" name="Num Giri asse J (4) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_InvDDone" name="Num cambi direzione asse J (4)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="CONDITION" id="AX04_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="AX04_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Axis_04_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_04_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Rotary>
|
||||
<Rotary id="Axis_05" name="Asse C (5)">
|
||||
@@ -152,8 +152,8 @@
|
||||
<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_DistDone" name="Num Giri asse k (5) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_InvDDone" name="Num cambi direzione asse K (5)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="CONDITION" id="AX05_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="AX05_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Axis_05_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_05_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Rotary>
|
||||
</Components>
|
||||
@@ -188,8 +188,8 @@
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActI" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo I"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActJ" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo J"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActK" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo K"/>
|
||||
<DataItem category="CONDITION" id="Path_01_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Path_01_PLC" type="LOGIC"/>
|
||||
<DataItem category="CONDITION" id="Path_01_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Path_01_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Path>
|
||||
<!-- probabilmente da ri-spostare sotto PATH... -->
|
||||
@@ -285,6 +285,7 @@
|
||||
<!-- <DataItem type="TEMPERATURE" id="Temp_04_Value" category="SAMPLE" name="Sonda Temperatura 4" units="DEGREE"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_05_Value" category="SAMPLE" name="Sonda Temperatura 5" units="DEGREE"/> -->
|
||||
<DataItem type="PRESSURE" id="Press_01_Value" category="SAMPLE" name="Pressostato 1" units="PASCAL"/>
|
||||
<DataItem type="PRESSURE" id="Press_02_Value" category="SAMPLE" name="Pressostato 2" units="PASCAL"/>
|
||||
</DataItems>
|
||||
</Sensor>
|
||||
</Components>
|
||||
|
||||
@@ -0,0 +1,293 @@
|
||||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<MTConnectDevices xmlns:m="urn:mtconnect.org:MTConnectDevices:1.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="urn:mtconnect.org:MTConnectDevices:1.1" xsi:schemaLocation="urn:mtconnect.org:MTConnectDevices:1.1 http://www.mtconnect.org/schemas/MTConnectDevices_1.1.xsd">
|
||||
<Header creationTime="2016-04-28T08:44:40+00:00" sender="localhost" instanceId="3" bufferSize="131072" version="1.1"/>
|
||||
<Devices>
|
||||
<Device id="demo_123456" iso841Class="6" name="CMS-ARES" sampleInterval="10" uuid="000123456">
|
||||
<Description manufacturer="CMS">Macchina 6 assi ARES</Description>
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="AVAIL" type="AVAILABILITY"/>
|
||||
<DataItem category="EVENT" id="STATUS" type="ACTUATOR_STATE"/>
|
||||
<DataItem category="SAMPLE" id="ACC_TIME" name="Tempo macchina ON" type="ACCUMULATED_TIME"/>
|
||||
<DataItem category="SAMPLE" id="ACC_TIME_WORK" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
|
||||
<DataItem category="SAMPLE" id="CLOCK" type="CLOCK_TIME"/>
|
||||
<DataItem category="SAMPLE" id="POWER" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="OperatorId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="FUNCT_MODE" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="USER_ACTION" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="TESTING_DATA" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="PROTECTION_STATUS" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="UNK_STATUS" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="UNK_STROBE" type="MESSAGE"/>
|
||||
<DataItem category="CONDITION" id="CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="PLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
<Components>
|
||||
<Axes id="ax" name="Axes">
|
||||
<Components>
|
||||
<Linear id="Axis_01" name="Asse X">
|
||||
<DataItems>
|
||||
<!-- descrizione, es "X" che POTREBBE cambiare -->
|
||||
<DataItem category="EVENT" id="Axis_01_Descr" type="MESSAGE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_PosAct" name="Pos asse X (1) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_PosTgt" name="Pos asse X (1) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_Load" name="Load asse X (1)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<DataItem category="EVENT" id="Axis_01_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_01_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_01_MastId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_01_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_FeedAct" name="FEEDRATE Asse X (1)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_FeedOver" name="FEEDRATE OVERRIDE Asse X (1)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_AccTime" name="Tempo impiego cumulato asse X (1)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_01_InvDDone" name="Num cambi direzione asse X (1)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="Axis_01_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_01_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_02" name="Asse Y">
|
||||
<DataItems>
|
||||
<!-- descrizione, es "Asse Y (2)" che POTREBBE cambiare -->
|
||||
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_PosAct" name="Pos asse Y (2) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_PosTgt" name="Pos asse Y (2) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_Load" name="Load asse Y (2)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<DataItem category="EVENT" id="Axis_02_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_02_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_02_MastId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_02_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_FeedAct" name="FEEDRATE Asse Y (2)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_FeedOver" name="FEEDRATE OVERRIDE Asse Y (2)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_AccTime" name="Tempo impiego cumulato asse Y (2)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_02_InvDDone" name="Num cambi direzione asse Y (2)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="Axis_02_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_02_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_03" name="Asse Z">
|
||||
<DataItems>
|
||||
<!-- descrizione, es "Asse Z (3)" che POTREBBE cambiare -->
|
||||
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_PosAct" name="Pos asse Z (3) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_PosTgt" name="Pos asse Z (3) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_Load" name="Load asse Z (3)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<DataItem category="EVENT" id="Axis_03_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_03_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_03_MastId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_03_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_FeedAct" name="FEEDRATE Asse Z (3)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_FeedOver" name="FEEDRATE OVERRIDE Asse Z (3)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_AccTime" name="Tempo impiego cumulato asse Z (3)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_03_InvDDone" name="Num cambi direzione asse X (3)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="Axis_03_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_03_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Linear id="Axis_06" name="Asse U">
|
||||
<DataItems>
|
||||
<!-- Descrizione, es "U" che POTREBBE cambiare se si sposta di path -->
|
||||
<DataItem category="EVENT" id="Axis_06_Descr" type="MESSAGE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_PosAct" name="Pos asse U (6) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_PosTgt" name="Pos asse U (6) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_Load" name="Load asse U (6)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<DataItem category="EVENT" id="Axis_06_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_06_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_06_MastId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_06_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_FeedAct" name="FEEDRATE Asse U (6)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_FeedOver" name="FEEDRATE OVERRIDE Asse U (6)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_AccTime" name="Tempo impiego cumulato asse U (6)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
|
||||
<DataItem category="SAMPLE" id="Axis_06_InvDDone" name="Num cambi direzione asse U (6)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />
|
||||
<DataItem category="CONDITION" id="Axis_06_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_06_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Linear>
|
||||
<Rotary id="Axis_04" name="Asse B">
|
||||
<DataItems>
|
||||
<DataItem category="SAMPLE" id="Axis_04_PosAct" name="Pos asse J (4) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_PosTgt" name="Pos asse J (4) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_Load" name="Load asse J (4)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<DataItem category="EVENT" id="Axis_04_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_04_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_04_MastId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_04_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_FeedAct" name="ROT SPEED Asse J (4)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_FeedOver" name="ROT SPEED OVERRIDE Asse J (4)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_AccelAct" name="Accelerazione angolare asse J (4)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_AccTime" name="Tempo impiego cumulato asse J (4)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_DistDone" name="Num Giri asse J (4) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_04_InvDDone" name="Num cambi direzione asse J (4)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="CONDITION" id="Axis_04_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_04_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Rotary>
|
||||
<Rotary id="Axis_05" name="Asse C (5)">
|
||||
<DataItems>
|
||||
<DataItem category="SAMPLE" id="Axis_05_PosAct" name="Pos asse K (5) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_PosTgt" name="Pos asse K (5) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_Load" name="Load asse K (5)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<DataItem category="EVENT" id="Axis_05_MainProc" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_05_IsMast" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_05_MastId" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Axis_05_Dir" type="DIRECTION"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_FeedAct" name="ROT SPEED Asse K (5)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_FeedOver" name="ROT SPEED OVERRIDE Asse K (5)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_AccelAct" name="Accelerazione angolare asse K (5)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_AccTime" name="Tempo impiego cumulato asse K (5)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_DistDone" name="Num Giri asse k (5) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
|
||||
<DataItem category="SAMPLE" id="Axis_05_InvDDone" name="Num cambi direzione asse K (5)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="CONDITION" id="Axis_05_AlarmCNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Axis_05_AlarmPLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Rotary>
|
||||
</Components>
|
||||
</Axes>
|
||||
<Controller id="cn1" name="controller">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Message" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="E_STOP" type="EMERGENCY_STOP"/>
|
||||
</DataItems>
|
||||
<Components>
|
||||
<Path id="Path_01" name="Path 01">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Path_01_Type" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_ActiveAxes" type="ACTIVE_AXES"/>
|
||||
<DataItem category="EVENT" id="Path_01_CodG_Act" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_SubMode" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_PartId" type="PART_ID"/>
|
||||
<DataItem category="EVENT" id="Path_01_PZ_TOT" type="PART_COUNT"/>
|
||||
<DataItem category="EVENT" id="Path_01_Cod_M" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_Cod_S" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_Cod_T" type="MESSAGE"/>
|
||||
<DataItem category="EVENT" id="Path_01_RUN_MODE" type="CONTROLLER_MODE"/>
|
||||
<DataItem category="EVENT" id="Path_01_EXE_MODE" type="EXECUTION"/>
|
||||
<DataItem category="EVENT" id="Path_01_CurrProg" type="PROGRAM"/>
|
||||
<DataItem category="EVENT" id="Path_01_CurrProg_RowNum" type="LINE"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_FeedRate" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="Path FEED"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_FeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="Path FEED Override"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_RapidOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="Path RAPID Override"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActX" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione X"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActY" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione Y"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActZ" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione Z"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActI" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo I"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActJ" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo J"/>
|
||||
<DataItem category="SAMPLE" id="Path_01_PosActK" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo K"/>
|
||||
<DataItem category="CONDITION" id="Path_01_CNC" type="SYSTEM"/>
|
||||
<DataItem category="CONDITION" id="Path_01_PLC" type="LOGIC"/>
|
||||
</DataItems>
|
||||
</Path>
|
||||
<!-- probabilmente da ri-spostare sotto PATH... -->
|
||||
<Actuator id="UniOp_01" name ="Unità Operatrice 01">
|
||||
<DataItems>
|
||||
<DataItem category="SAMPLE" id="UnOp_01_Speed" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="UnOp Speed"/>
|
||||
<DataItem category="SAMPLE" id="UnOp_01_SpeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="UnOp SPEED Override"/>
|
||||
<DataItem category="EVENT" id="UnOp_01_ToolId" name="TOOL ID" type="TOOL_ASSET_ID"/>
|
||||
<DataItem category="EVENT" id="UnOp_01_NumCU" name="Num Cambi Utensile effettuati" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category="EVENT" id="UnOp_01_Status" type="ACTUATOR_STATE"/>
|
||||
<DataItem category="EVENT" id="UnOp_01_VitaRes" name="Vita Residua Tool" type="MESSAGE" units="COUNT"/>
|
||||
<DataItem category = "EVENT" id = "UnOp_01_VitaResType" name = "Tipologia misura Vita Residua Tool" type = "MESSAGE" />
|
||||
<DataItem category="SAMPLE" id="UnOp_01_Load" name="Load sul PATH/UnOp" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
|
||||
<!-- cambiare in event... -->
|
||||
<DataItem category="SAMPLE" id="UnOp_01_AccTime" name="Totale giri (migliaia) accumulati dal mandrino" type="COUNT"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
</Components>
|
||||
</Controller>
|
||||
<Systems id="systems" name="systems">
|
||||
<Components>
|
||||
<Electric id="el" name="electric">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="p2" name="power" type="POWER_STATE"/>
|
||||
</DataItems>
|
||||
</Electric>
|
||||
<Hydraulic id="hsys" name="hydraulic">
|
||||
<!--<DataItems>
|
||||
<DataItem category="CONDITION" id="hlow" type="LEVEL"/>
|
||||
<DataItem category="CONDITION" id="hpres" type="PRESSURE"/>
|
||||
<DataItem category="CONDITION" id="htemp" type="TEMPERATURE"/>
|
||||
</DataItems>-->
|
||||
</Hydraulic>
|
||||
<Pneumatic id="PneumSys" name="Pneumatic Systems">
|
||||
<Actuator id="VacPump_01" name ="Pompa 1">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="VacPump_01_Status" name="Stato Pompa 1" type="ACTUATOR_STATE"/>
|
||||
<DataItem category="SAMPLE" id="VacPump_01_WrkTime" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
<Actuator id="VacPump_02" name ="Pompa 2">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="VacPump_02_Status" name="Stato Pompa 2" type="ACTUATOR_STATE"/>
|
||||
<DataItem category="SAMPLE" id="VacPump_02_WrkTime" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
<Actuator id="VacAct_01" name ="Valvola vuoto 1">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="VacAct_01_Count" name="Contatore attivazioni valvola attuatore 1" type="MESSAGE" units="COUNT"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
<Actuator id="VacAct_02" name ="Valvola vuoto 2">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="VacAct_02_Count" name="Contatore attivazioni valvola attuatore 2" type="MESSAGE" units="COUNT"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
</Pneumatic>
|
||||
<Coolant id="cool" name="coolant">
|
||||
<!--<DataItems>
|
||||
<DataItem category="CONDITION" id="clow" type="LEVEL"/>
|
||||
<DataItem category="CONDITION" id="coolpres" type="PRESSURE"/>
|
||||
<DataItem category="CONDITION" id="filter" type="x:FILTER"/>
|
||||
<DataItem category="CONDITION" id="coolantmotor" type="ACTUATOR"/>
|
||||
</DataItems>-->
|
||||
<Actuator id="Cooler_01" name ="Cooler 1">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Cooler_01_Status" name="Stato Cooler 1" type="ACTUATOR_STATE"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
<Actuator id="Cooler_02" name ="Cooler 2">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Cooler_02_Status" name="Stato Cooler 2" type="ACTUATOR_STATE"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
</Coolant>
|
||||
<Lubrication id="LubroSys" name="Lubricant Systems">
|
||||
<Actuator id="Lubro_01" name ="Lubrorefrigerante 1">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Lubro_01_Num" name="Contatore lubro 1" type="MESSAGE" units="COUNT"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
<Actuator id="Lubro_02" name ="Lubrorefrigerante 2">
|
||||
<DataItems>
|
||||
<DataItem category="EVENT" id="Lubro_02_Num" name="Contatore lubro 2" type="MESSAGE" units="COUNT"/>
|
||||
</DataItems>
|
||||
</Actuator>
|
||||
</Lubrication>
|
||||
</Components>
|
||||
</Systems>
|
||||
<Sensor id="sens1" name="Sensorunit">
|
||||
<DataItems>
|
||||
<!-- verificare di poterli spostare e siano 4, 1 x ogni asse lineare >>> SPOSTARE!!!!!! -->
|
||||
<!-- <DataItem type="TEMPERATURE" id="Temp_04_Value" category="SAMPLE" name="Sonda Temperatura 4" units="DEGREE"/>
|
||||
<DataItem type="TEMPERATURE" id="Temp_05_Value" category="SAMPLE" name="Sonda Temperatura 5" units="DEGREE"/> -->
|
||||
<DataItem type="PRESSURE" id="Press_01_Value" category="SAMPLE" name="Pressostato 1" units="PASCAL"/>
|
||||
</DataItems>
|
||||
</Sensor>
|
||||
</Components>
|
||||
</Device>
|
||||
</Devices>
|
||||
</MTConnectDevices>
|
||||
@@ -4,7 +4,7 @@
|
||||
000003|PLC|FAULT|[COD 001002] - 404 BILANCIAMENTO ASSE Z INSUFFICIENTE
|
||||
000004|PLC|FAULT|[COD 001003] - 403 SURRISCALDAMENTO ARMADIO ELETTRICO
|
||||
000005|PLC|FAULT|[COD 001004] - 173 CAMBIARE LA BATTERIA
|
||||
000006|PLC|FAULT|[COD 001005] - 407 UNO O PI@0DB401@ ASSI IN EXTRA CORSA
|
||||
000006|PLC|FAULT|[COD 001005] - 407 UNO O PIÙ ASSI IN EXTRA CORSA
|
||||
000007|PLC|FAULT|[COD 001006] - 406 PULSANTI DI EMERGENZA
|
||||
000008|PLC|FAULT|[COD 001007] - ...
|
||||
000009|PLC|FAULT|[COD 001008] - 583 MACCHINA SPENTA
|
||||
@@ -276,13 +276,13 @@
|
||||
000275|PLC|FAULT|[COD 002018] - 362 MONTANTE CENTRALE NON IN POSIZIONE
|
||||
000276|PLC|FAULT|[COD 002019] - 157 SICUREZZE ANTICADUTA ASSE Z NON OK
|
||||
000277|PLC|FAULT|[COD 002020] - 158 PIOLO ANTICADUTA ASSE Z NON IN POSIZIONE
|
||||
000278|PLC|FAULT|[COD 002021] - 115 CONTROLLO VELOCIT@0DA001@ MANDRINO
|
||||
000278|PLC|FAULT|[COD 002021] - 115 CONTROLLO VELOCITÀ MANDRINO
|
||||
000279|PLC|FAULT|[COD 002022] - 135 CONVERTITORE IN BLOCCO
|
||||
000280|PLC|FAULT|[COD 002023] - 514 PROTEZIONE SUPPORTO LASER NON IN POSIZIONE
|
||||
000281|PLC|FAULT|[COD 002024] - 561 LASER NON IN POSIZIONE
|
||||
000282|PLC|FAULT|[COD 002025] - 230 REL@0DA601@ TERMICO POMPA VUOTO 1
|
||||
000283|PLC|FAULT|[COD 002026] - 230 REL@0DA601@ TERMICO POMPA VUOTO 2
|
||||
000284|PLC|FAULT|[COD 002027] - 200 REL@0DA601@ TERMICO MANDRINO
|
||||
000282|PLC|FAULT|[COD 002025] - 230 RELÉ TERMICO POMPA VUOTO 1
|
||||
000283|PLC|FAULT|[COD 002026] - 230 RELÉ TERMICO POMPA VUOTO 2
|
||||
000284|PLC|FAULT|[COD 002027] - 200 RELÉ TERMICO MANDRINO
|
||||
000285|PLC|FAULT|[COD 002028] - 168 CONVERTITORE NON ABILITATO
|
||||
000286|PLC|FAULT|[COD 002029] - 333 COMUNICAZIONE VOLANTINO IN ERRORE
|
||||
000287|PLC|FAULT|[COD 002030] - 390 FUNZIONE T NON PERMESSA
|
||||
@@ -322,7 +322,7 @@
|
||||
000321|PLC|FAULT|[COD 002064] - 551 CONDIZIONI NON OK PER GRUPPO A FORARE
|
||||
000322|PLC|FAULT|[COD 002065] - 265 ASSE B NON IN POSIZIONE PER AZZERAMENTO
|
||||
000323|PLC|FAULT|[COD 002066] - 265 ASSE C NON IN POSIZIONE PER AZZERAMENTO
|
||||
000324|PLC|FAULT|[COD 002067] - 270 REL@0DA601@ TERMICO GRUPPO DI FORATURA
|
||||
000324|PLC|FAULT|[COD 002067] - 270 RELÉ TERMICO GRUPPO DI FORATURA
|
||||
000325|PLC|FAULT|[COD 002068] - ...
|
||||
000326|PLC|FAULT|[COD 002069] - ...
|
||||
000327|PLC|FAULT|[COD 002070] - 105 STOP DA DISPOSITIVO DI MONITORAGGIO
|
||||
@@ -330,7 +330,7 @@
|
||||
000329|PLC|FAULT|[COD 002072] - 551 CONDIZIONI NON OK PER GRUPPO A FORARE
|
||||
000330|PLC|FAULT|[COD 002073] - 265 ASSE B NON IN POSIZIONE PER AZZERAMENTO
|
||||
000331|PLC|FAULT|[COD 002074] - 265 ASSE C NON IN POSIZIONE PER AZZERAMENTO
|
||||
000332|PLC|FAULT|[COD 002075] - 270 REL@0DA601@ TERMICO GRUPPO DI FORATURA
|
||||
000332|PLC|FAULT|[COD 002075] - 270 RELÉ TERMICO GRUPPO DI FORATURA
|
||||
000333|PLC|FAULT|[COD 002076] - ...
|
||||
000334|PLC|FAULT|[COD 002077] - ...
|
||||
000335|PLC|FAULT|[COD 002078] - 105 STOP DA DISPOSITIVO DI MONITORAGGIO
|
||||
|
||||