Riorganizzazione folder INSTALLER (git e su dropbox) x gestione deploy con nuove cartelle...

This commit is contained in:
Samuele E. Locatelli
2016-12-09 17:39:01 +01:00
parent b33a7542dc
commit 38fd291ea3
56 changed files with 4126 additions and 23809 deletions
@@ -10,7 +10,7 @@
<DataItem category="SAMPLE" id="ACC_TIME" name="Tempo macchina ON" type="ACCUMULATED_TIME"/>
<DataItem category="SAMPLE" id="ACC_TIME_WORK" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
<DataItem category="SAMPLE" id="CLOCK" type="CLOCK_TIME"/>
<DataItem category="SAMPLE" id="POWER" type="MESSAGE"/>
<DataItem category="EVENT" id="POWER" type="POWER_STATE"/>
<DataItem category="EVENT" id="OperatorId" type="MESSAGE"/>
<DataItem category="EVENT" id="FUNCT_MODE" type="MESSAGE"/>
<DataItem category="EVENT" id="USER_ACTION" type="MESSAGE"/>
@@ -27,93 +27,93 @@
<Linear id="Axis_01" name="Asse X">
<DataItems>
<!-- descrizione, es "X" che POTREBBE cambiare -->
<!--<DataItem category="EVENT" id="Axis_01_Descr" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_01_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_01_PosAct" name="Pos asse X (1) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_01_PosTgt" name="Pos asse X (1) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_01_Load" name="Load asse X (1)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!--<DataItem category="EVENT" id="Axis_01_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_MastId" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_01_Dir" type="DIRECTION"/>
<DataItem category="EVENT" id="Axis_01_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_01_FeedAct" name="FEEDRATE Asse X (1)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_01_FeedOver" name="FEEDRATE OVERRIDE Asse X (1)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<!--<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_01_AccTime" name="Tempo impiego cumulato asse X (1)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<!--<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="METER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_01_InvDDone" name="Num cambi direzione asse X (1)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<!--<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />-->
<DataItem category="CONDITION" id="AX01_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="AX01_PLC" type="LOGIC"/>
<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_01_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_01_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_02" name="Asse Y">
<DataItems>
<!-- descrizione, es "Asse Y (2)" che POTREBBE cambiare -->
<!--<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_02_PosAct" name="Pos asse Y (2) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_02_PosTgt" name="Pos asse Y (2) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_02_Load" name="Load asse Y (2)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!--<DataItem category="EVENT" id="Axis_02_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_MastId" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_02_Dir" type="DIRECTION"/>
<DataItem category="EVENT" id="Axis_02_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_02_FeedAct" name="FEEDRATE Asse Y (2)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_02_FeedOver" name="FEEDRATE OVERRIDE Asse Y (2)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<!--<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_02_AccTime" name="Tempo impiego cumulato asse Y (2)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<!--<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="METER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_02_InvDDone" name="Num cambi direzione asse Y (2)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<!--<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />-->
<DataItem category="CONDITION" id="AX02_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="AX02_PLC" type="LOGIC"/>
<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_02_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_02_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_03" name="Asse Z">
<DataItems>
<!-- descrizione, es "Asse Z (3)" che POTREBBE cambiare -->
<!--<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_03_PosAct" name="Pos asse Z (3) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_03_PosTgt" name="Pos asse Z (3) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_03_Load" name="Load asse Z (3)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!--<DataItem category="EVENT" id="Axis_03_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_MastId" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_03_Dir" type="DIRECTION"/>
<DataItem category="EVENT" id="Axis_03_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_03_FeedAct" name="FEEDRATE Asse Z (3)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_03_FeedOver" name="FEEDRATE OVERRIDE Asse Z (3)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<!--<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_03_AccTime" name="Tempo impiego cumulato asse Z (3)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<!--<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="METER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_03_InvDDone" name="Num cambi direzione asse X (3)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<!--<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />-->
<DataItem category="CONDITION" id="AX03_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="AX03_PLC" type="LOGIC"/>
<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_03_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_03_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_06" name="Asse U">
<DataItems>
<!-- Descrizione, es "U" che POTREBBE cambiare se si sposta di path -->
<!--<DataItem category="EVENT" id="Axis_06_Descr" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_06_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_06_PosAct" name="Pos asse U (6) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_06_PosTgt" name="Pos asse U (6) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_06_Load" name="Load asse U (6)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!--<DataItem category="EVENT" id="Axis_06_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_MastId" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_06_Dir" type="DIRECTION"/>
<DataItem category="EVENT" id="Axis_06_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_06_FeedAct" name="FEEDRATE Asse U (6)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_06_FeedOver" name="FEEDRATE OVERRIDE Asse U (6)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<!--<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>-->
<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_06_AccTime" name="Tempo impiego cumulato asse U (6)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<!--<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="METER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_06_InvDDone" name="Num cambi direzione asse U (6)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<!--<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />-->
<DataItem category="CONDITION" id="AX06_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="AX06_PLC" type="LOGIC"/>
<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_06_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_06_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Rotary id="Axis_04" name="Asse B">
@@ -121,19 +121,19 @@
<DataItem category="SAMPLE" id="Axis_04_PosAct" name="Pos asse J (4) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_04_PosTgt" name="Pos asse J (4) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_04_Load" name="Load asse J (4)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!--<DataItem category="EVENT" id="Axis_04_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_MastId" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_04_Dir" type="DIRECTION"/>
<DataItem category="EVENT" id="Axis_04_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_Dir" type="DIRECTION" subtype="ROTARY"/>
<DataItem category="SAMPLE" id="Axis_04_FeedAct" name="ROT SPEED Asse J (4)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
<DataItem category="SAMPLE" id="Axis_04_FeedOver" name="ROT SPEED OVERRIDE Asse J (4)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
<!--<DataItem category="SAMPLE" id="Axis_04_AccelAct" name="Accelerazione angolare asse J (4)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>-->
<DataItem category="SAMPLE" id="Axis_04_AccelAct" name="Accelerazione angolare asse J (4)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_04_AccTime" name="Tempo impiego cumulato asse J (4)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<!--<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_04_DistDone" name="Num Giri asse J (4) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
<DataItem category="SAMPLE" id="Axis_04_InvDDone" name="Num cambi direzione asse J (4)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem category="CONDITION" id="AX04_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="AX04_PLC" type="LOGIC"/>
<DataItem category="CONDITION" id="Axis_04_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_04_AlarmPLC" type="LOGIC"/>
</DataItems>
</Rotary>
<Rotary id="Axis_05" name="Asse C (5)">
@@ -141,19 +141,19 @@
<DataItem category="SAMPLE" id="Axis_05_PosAct" name="Pos asse K (5) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_05_PosTgt" name="Pos asse K (5) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_05_Load" name="Load asse K (5)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!--<DataItem category="EVENT" id="Axis_05_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_MastId" type="MESSAGE"/>-->
<DataItem category="EVENT" id="Axis_05_Dir" type="DIRECTION"/>
<DataItem category="EVENT" id="Axis_05_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_Dir" type="DIRECTION" subtype="ROTARY"/>
<DataItem category="SAMPLE" id="Axis_05_FeedAct" name="ROT SPEED Asse K (5)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
<DataItem category="SAMPLE" id="Axis_05_FeedOver" name="ROT SPEED OVERRIDE Asse K (5)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
<!--<DataItem category="SAMPLE" id="Axis_05_AccelAct" name="Accelerazione angolare asse K (5)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>-->
<DataItem category="SAMPLE" id="Axis_05_AccelAct" name="Accelerazione angolare asse K (5)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_05_AccTime" name="Tempo impiego cumulato asse K (5)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<!--<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>-->
<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_05_DistDone" name="Num Giri asse k (5) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
<DataItem category="SAMPLE" id="Axis_05_InvDDone" name="Num cambi direzione asse K (5)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem category="CONDITION" id="AX05_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="AX05_PLC" type="LOGIC"/>
<DataItem category="CONDITION" id="Axis_05_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_05_AlarmPLC" type="LOGIC"/>
</DataItems>
</Rotary>
</Components>
@@ -188,8 +188,8 @@
<DataItem category="SAMPLE" id="Path_01_PosActI" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo I"/>
<DataItem category="SAMPLE" id="Path_01_PosActJ" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo J"/>
<DataItem category="SAMPLE" id="Path_01_PosActK" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo K"/>
<DataItem category="CONDITION" id="Path_01_CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Path_01_PLC" type="LOGIC"/>
<DataItem category="CONDITION" id="Path_01_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Path_01_AlarmPLC" type="LOGIC"/>
</DataItems>
</Path>
<!-- probabilmente da ri-spostare sotto PATH... -->
@@ -213,7 +213,7 @@
<Components>
<Electric id="el" name="electric">
<DataItems>
<!--<DataItem category="EVENT" id="p2" name="power" type="POWER_STATE"/>-->
<DataItem category="EVENT" id="p2" name="power" type="POWER_STATE"/>
</DataItems>
</Electric>
<Hydraulic id="hsys" name="hydraulic">
@@ -285,6 +285,7 @@
<!-- <DataItem type="TEMPERATURE" id="Temp_04_Value" category="SAMPLE" name="Sonda Temperatura 4" units="DEGREE"/>
<DataItem type="TEMPERATURE" id="Temp_05_Value" category="SAMPLE" name="Sonda Temperatura 5" units="DEGREE"/> -->
<DataItem type="PRESSURE" id="Press_01_Value" category="SAMPLE" name="Pressostato 1" units="PASCAL"/>
<DataItem type="PRESSURE" id="Press_02_Value" category="SAMPLE" name="Pressostato 2" units="PASCAL"/>
</DataItems>
</Sensor>
</Components>
@@ -0,0 +1,294 @@
<?xml version="1.0" encoding="UTF-8"?>
<MTConnectDevices xmlns:m="urn:mtconnect.org:MTConnectDevices:1.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="urn:mtconnect.org:MTConnectDevices:1.1" xsi:schemaLocation="urn:mtconnect.org:MTConnectDevices:1.1 http://www.mtconnect.org/schemas/MTConnectDevices_1.1.xsd">
<Header creationTime="2016-04-28T08:44:40+00:00" sender="localhost" instanceId="3" bufferSize="131072" version="1.1"/>
<Devices>
<Device id="demo_123456" iso841Class="6" name="CMS-ARES" sampleInterval="10" uuid="000123456">
<Description manufacturer="CMS">Macchina 6 assi ARES</Description>
<DataItems>
<DataItem category="EVENT" id="AVAIL" type="AVAILABILITY"/>
<DataItem category="EVENT" id="STATUS" type="ACTUATOR_STATE"/>
<DataItem category="SAMPLE" id="ACC_TIME" name="Tempo macchina ON" type="ACCUMULATED_TIME"/>
<DataItem category="SAMPLE" id="ACC_TIME_WORK" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
<DataItem category="SAMPLE" id="CLOCK" type="CLOCK_TIME"/>
<DataItem category="EVENT" id="POWER" type="POWER_STATE"/>
<DataItem category="EVENT" id="OperatorId" type="MESSAGE"/>
<DataItem category="EVENT" id="FUNCT_MODE" type="MESSAGE"/>
<DataItem category="EVENT" id="USER_ACTION" type="MESSAGE"/>
<DataItem category="EVENT" id="TESTING_DATA" type="MESSAGE"/>
<DataItem category="EVENT" id="PROTECTION_STATUS" type="MESSAGE"/>
<DataItem category="EVENT" id="UNK_STATUS" type="MESSAGE"/>
<DataItem category="EVENT" id="UNK_STROBE" type="MESSAGE"/>
<DataItem category="CONDITION" id="CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="PLC" type="LOGIC"/>
</DataItems>
<Components>
<Axes id="ax" name="Axes">
<Components>
<Linear id="Axis_01" name="Asse X">
<DataItems>
<!-- descrizione, es "X" che POTREBBE cambiare -->
<DataItem category="EVENT" id="Axis_01_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_01_PosAct" name="Pos asse X (1) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_01_PosTgt" name="Pos asse X (1) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_01_Load" name="Load asse X (1)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_01_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_01_FeedAct" name="FEEDRATE Asse X (1)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_01_FeedOver" name="FEEDRATE OVERRIDE Asse X (1)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_01_AccTime" name="Tempo impiego cumulato asse X (1)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_01_InvDDone" name="Num cambi direzione asse X (1)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_01_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_01_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_02" name="Asse Y">
<DataItems>
<!-- descrizione, es "Asse Y (2)" che POTREBBE cambiare -->
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_02_PosAct" name="Pos asse Y (2) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_02_PosTgt" name="Pos asse Y (2) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_02_Load" name="Load asse Y (2)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_02_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_02_FeedAct" name="FEEDRATE Asse Y (2)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_02_FeedOver" name="FEEDRATE OVERRIDE Asse Y (2)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_02_AccTime" name="Tempo impiego cumulato asse Y (2)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_02_InvDDone" name="Num cambi direzione asse Y (2)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_02_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_02_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_03" name="Asse Z">
<DataItems>
<!-- descrizione, es "Asse Z (3)" che POTREBBE cambiare -->
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_03_PosAct" name="Pos asse Z (3) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_03_PosTgt" name="Pos asse Z (3) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_03_Load" name="Load asse Z (3)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_03_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_03_FeedAct" name="FEEDRATE Asse Z (3)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_03_FeedOver" name="FEEDRATE OVERRIDE Asse Z (3)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_03_AccTime" name="Tempo impiego cumulato asse Z (3)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_03_InvDDone" name="Num cambi direzione asse X (3)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_03_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_03_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_06" name="Asse U">
<DataItems>
<!-- Descrizione, es "U" che POTREBBE cambiare se si sposta di path -->
<DataItem category="EVENT" id="Axis_06_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_06_PosAct" name="Pos asse U (6) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_06_PosTgt" name="Pos asse U (6) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_06_Load" name="Load asse U (6)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_06_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_06_FeedAct" name="FEEDRATE Asse U (6)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_06_FeedOver" name="FEEDRATE OVERRIDE Asse U (6)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_06_AccTime" name="Tempo impiego cumulato asse U (6)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_06_InvDDone" name="Num cambi direzione asse U (6)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_06_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_06_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Rotary id="Axis_04" name="Asse B">
<DataItems>
<DataItem category="SAMPLE" id="Axis_04_PosAct" name="Pos asse J (4) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_04_PosTgt" name="Pos asse J (4) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_04_Load" name="Load asse J (4)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_04_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_Dir" type="DIRECTION" subtype="ROTARY"/>
<DataItem category="SAMPLE" id="Axis_04_FeedAct" name="ROT SPEED Asse J (4)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
<DataItem category="SAMPLE" id="Axis_04_FeedOver" name="ROT SPEED OVERRIDE Asse J (4)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_04_AccelAct" name="Accelerazione angolare asse J (4)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_04_AccTime" name="Tempo impiego cumulato asse J (4)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_04_DistDone" name="Num Giri asse J (4) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
<DataItem category="SAMPLE" id="Axis_04_InvDDone" name="Num cambi direzione asse J (4)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem category="CONDITION" id="Axis_04_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_04_AlarmPLC" type="LOGIC"/>
</DataItems>
</Rotary>
<Rotary id="Axis_05" name="Asse C (5)">
<DataItems>
<DataItem category="SAMPLE" id="Axis_05_PosAct" name="Pos asse K (5) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_05_PosTgt" name="Pos asse K (5) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_05_Load" name="Load asse K (5)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_05_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_Dir" type="DIRECTION" subtype="ROTARY"/>
<DataItem category="SAMPLE" id="Axis_05_FeedAct" name="ROT SPEED Asse K (5)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
<DataItem category="SAMPLE" id="Axis_05_FeedOver" name="ROT SPEED OVERRIDE Asse K (5)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_05_AccelAct" name="Accelerazione angolare asse K (5)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_05_AccTime" name="Tempo impiego cumulato asse K (5)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_05_DistDone" name="Num Giri asse k (5) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
<DataItem category="SAMPLE" id="Axis_05_InvDDone" name="Num cambi direzione asse K (5)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem category="CONDITION" id="Axis_05_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_05_AlarmPLC" type="LOGIC"/>
</DataItems>
</Rotary>
</Components>
</Axes>
<Controller id="cn1" name="controller">
<DataItems>
<DataItem category="EVENT" id="Message" type="MESSAGE"/>
<DataItem category="EVENT" id="E_STOP" type="EMERGENCY_STOP"/>
</DataItems>
<Components>
<Path id="Path_01" name="Path 01">
<DataItems>
<DataItem category="EVENT" id="Path_01_Type" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_ActiveAxes" type="ACTIVE_AXES"/>
<DataItem category="EVENT" id="Path_01_CodG_Act" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_SubMode" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_PartId" type="PART_ID"/>
<DataItem category="EVENT" id="Path_01_PZ_TOT" type="PART_COUNT"/>
<DataItem category="EVENT" id="Path_01_Cod_M" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_Cod_S" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_Cod_T" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_RUN_MODE" type="CONTROLLER_MODE"/>
<DataItem category="EVENT" id="Path_01_EXE_MODE" type="EXECUTION"/>
<DataItem category="EVENT" id="Path_01_CurrProg" type="PROGRAM"/>
<DataItem category="EVENT" id="Path_01_CurrProg_RowNum" type="LINE"/>
<DataItem category="SAMPLE" id="Path_01_FeedRate" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="Path FEED"/>
<DataItem category="SAMPLE" id="Path_01_FeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="Path FEED Override"/>
<DataItem category="SAMPLE" id="Path_01_RapidOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="Path RAPID Override"/>
<DataItem category="SAMPLE" id="Path_01_PosActX" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione X"/>
<DataItem category="SAMPLE" id="Path_01_PosActY" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione Y"/>
<DataItem category="SAMPLE" id="Path_01_PosActZ" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione Z"/>
<DataItem category="SAMPLE" id="Path_01_PosActI" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo I"/>
<DataItem category="SAMPLE" id="Path_01_PosActJ" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo J"/>
<DataItem category="SAMPLE" id="Path_01_PosActK" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo K"/>
<DataItem category="CONDITION" id="Path_01_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Path_01_AlarmPLC" type="LOGIC"/>
</DataItems>
</Path>
<!-- probabilmente da ri-spostare sotto PATH... -->
<Actuator id="UniOp_01" name ="Unità Operatrice 01">
<DataItems>
<DataItem category="SAMPLE" id="UnOp_01_Speed" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="UnOp Speed"/>
<DataItem category="SAMPLE" id="UnOp_01_SpeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="UnOp SPEED Override"/>
<DataItem category="EVENT" id="UnOp_01_ToolId" name="TOOL ID" type="TOOL_ASSET_ID"/>
<DataItem category="EVENT" id="UnOp_01_NumCU" name="Num Cambi Utensile effettuati" type="MESSAGE" units="COUNT"/>
<DataItem category="EVENT" id="UnOp_01_Status" type="ACTUATOR_STATE"/>
<DataItem category="EVENT" id="UnOp_01_VitaRes" name="Vita Residua Tool" type="MESSAGE" units="COUNT"/>
<DataItem category = "EVENT" id = "UnOp_01_VitaResType" name = "Tipologia misura Vita Residua Tool" type = "MESSAGE" />
<DataItem category="SAMPLE" id="UnOp_01_Load" name="Load sul PATH/UnOp" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!-- cambiare in event... -->
<DataItem category="SAMPLE" id="UnOp_01_AccTime" name="Totale giri (migliaia) accumulati dal mandrino" type="COUNT"/>
</DataItems>
</Actuator>
</Components>
</Controller>
<Systems id="systems" name="systems">
<Components>
<Electric id="el" name="electric">
<DataItems>
<DataItem category="EVENT" id="p2" name="power" type="POWER_STATE"/>
</DataItems>
</Electric>
<Hydraulic id="hsys" name="hydraulic">
<!--<DataItems>
<DataItem category="CONDITION" id="hlow" type="LEVEL"/>
<DataItem category="CONDITION" id="hpres" type="PRESSURE"/>
<DataItem category="CONDITION" id="htemp" type="TEMPERATURE"/>
</DataItems>-->
</Hydraulic>
<Pneumatic id="PneumSys" name="Pneumatic Systems">
<Actuator id="VacPump_01" name ="Pompa 1">
<DataItems>
<DataItem category="EVENT" id="VacPump_01_Status" name="Stato Pompa 1" type="ACTUATOR_STATE"/>
<DataItem category="SAMPLE" id="VacPump_01_WrkTime" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
</DataItems>
</Actuator>
<Actuator id="VacPump_02" name ="Pompa 2">
<DataItems>
<DataItem category="EVENT" id="VacPump_02_Status" name="Stato Pompa 2" type="ACTUATOR_STATE"/>
<DataItem category="SAMPLE" id="VacPump_02_WrkTime" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
</DataItems>
</Actuator>
<Actuator id="VacAct_01" name ="Valvola vuoto 1">
<DataItems>
<DataItem category="EVENT" id="VacAct_01_Count" name="Contatore attivazioni valvola attuatore 1" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
<Actuator id="VacAct_02" name ="Valvola vuoto 2">
<DataItems>
<DataItem category="EVENT" id="VacAct_02_Count" name="Contatore attivazioni valvola attuatore 2" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
</Pneumatic>
<Coolant id="cool" name="coolant">
<!--<DataItems>
<DataItem category="CONDITION" id="clow" type="LEVEL"/>
<DataItem category="CONDITION" id="coolpres" type="PRESSURE"/>
<DataItem category="CONDITION" id="filter" type="x:FILTER"/>
<DataItem category="CONDITION" id="coolantmotor" type="ACTUATOR"/>
</DataItems>-->
<Actuator id="Cooler_01" name ="Cooler 1">
<DataItems>
<DataItem category="EVENT" id="Cooler_01_Status" name="Stato Cooler 1" type="ACTUATOR_STATE"/>
</DataItems>
</Actuator>
<Actuator id="Cooler_02" name ="Cooler 2">
<DataItems>
<DataItem category="EVENT" id="Cooler_02_Status" name="Stato Cooler 2" type="ACTUATOR_STATE"/>
</DataItems>
</Actuator>
</Coolant>
<Lubrication id="LubroSys" name="Lubricant Systems">
<Actuator id="Lubro_01" name ="Lubrorefrigerante 1">
<DataItems>
<DataItem category="EVENT" id="Lubro_01_Num" name="Contatore lubro 1" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
<Actuator id="Lubro_02" name ="Lubrorefrigerante 2">
<DataItems>
<DataItem category="EVENT" id="Lubro_02_Num" name="Contatore lubro 2" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
</Lubrication>
</Components>
</Systems>
<Sensor id="sens1" name="Sensorunit">
<DataItems>
<!-- verificare di poterli spostare e siano 4, 1 x ogni asse lineare >>> SPOSTARE!!!!!! -->
<!-- <DataItem type="TEMPERATURE" id="Temp_04_Value" category="SAMPLE" name="Sonda Temperatura 4" units="DEGREE"/>
<DataItem type="TEMPERATURE" id="Temp_05_Value" category="SAMPLE" name="Sonda Temperatura 5" units="DEGREE"/> -->
<DataItem type="PRESSURE" id="Press_01_Value" category="SAMPLE" name="Pressostato 1" units="PASCAL"/>
<DataItem type="PRESSURE" id="Press_02_Value" category="SAMPLE" name="Pressostato 2" units="PASCAL"/>
</DataItems>
</Sensor>
</Components>
</Device>
</Devices>
</MTConnectDevices>
+294
View File
@@ -0,0 +1,294 @@
<?xml version="1.0" encoding="UTF-8"?>
<MTConnectDevices xmlns:m="urn:mtconnect.org:MTConnectDevices:1.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="urn:mtconnect.org:MTConnectDevices:1.1" xsi:schemaLocation="urn:mtconnect.org:MTConnectDevices:1.1 http://www.mtconnect.org/schemas/MTConnectDevices_1.1.xsd">
<Header creationTime="2016-04-28T08:44:40+00:00" sender="localhost" instanceId="3" bufferSize="131072" version="1.1"/>
<Devices>
<Device id="demo_123456" iso841Class="6" name="CMS-ARES" sampleInterval="10" uuid="000123456">
<Description manufacturer="CMS">Macchina 6 assi ARES</Description>
<DataItems>
<DataItem category="EVENT" id="AVAIL" type="AVAILABILITY"/>
<DataItem category="EVENT" id="STATUS" type="ACTUATOR_STATE"/>
<DataItem category="SAMPLE" id="ACC_TIME" name="Tempo macchina ON" type="ACCUMULATED_TIME"/>
<DataItem category="SAMPLE" id="ACC_TIME_WORK" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
<DataItem category="SAMPLE" id="CLOCK" type="CLOCK_TIME"/>
<DataItem category="EVENT" id="POWER" type="POWER_STATE"/>
<DataItem category="EVENT" id="OperatorId" type="MESSAGE"/>
<DataItem category="EVENT" id="FUNCT_MODE" type="MESSAGE"/>
<DataItem category="EVENT" id="USER_ACTION" type="MESSAGE"/>
<DataItem category="EVENT" id="TESTING_DATA" type="MESSAGE"/>
<DataItem category="EVENT" id="PROTECTION_STATUS" type="MESSAGE"/>
<DataItem category="EVENT" id="UNK_STATUS" type="MESSAGE"/>
<DataItem category="EVENT" id="UNK_STROBE" type="MESSAGE"/>
<DataItem category="CONDITION" id="CNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="PLC" type="LOGIC"/>
</DataItems>
<Components>
<Axes id="ax" name="Axes">
<Components>
<Linear id="Axis_01" name="Asse X">
<DataItems>
<!-- descrizione, es "X" che POTREBBE cambiare -->
<DataItem category="EVENT" id="Axis_01_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_01_PosAct" name="Pos asse X (1) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_01_PosTgt" name="Pos asse X (1) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_01_Load" name="Load asse X (1)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_01_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_01_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_01_FeedAct" name="FEEDRATE Asse X (1)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_01_FeedOver" name="FEEDRATE OVERRIDE Asse X (1)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_01_AccelAct" name="Accelerazione asse X (1)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_01_AccTime" name="Tempo impiego cumulato asse X (1)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_01_Battery" name="Valore batteria asse X (1)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_01_DistDone" name="Distanza TOTALE percorsa dall'asse X (1)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_01_InvDDone" name="Num cambi direzione asse X (1)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_01_Value" category="SAMPLE" name="Sonda Temperatura asse 1" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_01_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_01_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_02" name="Asse Y">
<DataItems>
<!-- descrizione, es "Asse Y (2)" che POTREBBE cambiare -->
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_02_PosAct" name="Pos asse Y (2) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_02_PosTgt" name="Pos asse Y (2) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_02_Load" name="Load asse Y (2)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_02_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_02_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_02_FeedAct" name="FEEDRATE Asse Y (2)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_02_FeedOver" name="FEEDRATE OVERRIDE Asse Y (2)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_02_AccelAct" name="Accelerazione asse Y (2)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_02_AccTime" name="Tempo impiego cumulato asse Y (2)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_02_Battery" name="Valore batteria asse Y (2)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_02_DistDone" name="Distanza TOTALE percorsa dall'asse Y (2)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_02_InvDDone" name="Num cambi direzione asse Y (2)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_02_Value" category="SAMPLE" name="Sonda Temperatura asse 2" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_02_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_02_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_03" name="Asse Z">
<DataItems>
<!-- descrizione, es "Asse Z (3)" che POTREBBE cambiare -->
<DataItem category="EVENT" id="Axis_02_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_03_PosAct" name="Pos asse Z (3) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_03_PosTgt" name="Pos asse Z (3) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_03_Load" name="Load asse Z (3)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_03_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_03_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_03_FeedAct" name="FEEDRATE Asse Z (3)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_03_FeedOver" name="FEEDRATE OVERRIDE Asse Z (3)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_03_AccelAct" name="Accelerazione asse Z (3)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_03_AccTime" name="Tempo impiego cumulato asse Z (3)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_03_Battery" name="Valore batteria asse Z (3)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_03_DistDone" name="Distanza TOTALE percorsa dall'asse Z (3)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_03_InvDDone" name="Num cambi direzione asse X (3)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_03_Value" category="SAMPLE" name="Sonda Temperatura asse 3" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_03_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_03_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Linear id="Axis_06" name="Asse U">
<DataItems>
<!-- Descrizione, es "U" che POTREBBE cambiare se si sposta di path -->
<DataItem category="EVENT" id="Axis_06_Descr" type="MESSAGE"/>
<DataItem category="SAMPLE" id="Axis_06_PosAct" name="Pos asse U (6) actual" nativeUnits="MILLIMETER" subType="ACTUAL" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_06_PosTgt" name="Pos asse U (6) target" nativeUnits="MILLIMETER" subType="COMMANDED" type="POSITION" units="MILLIMETER"/>
<DataItem category="SAMPLE" id="Axis_06_Load" name="Load asse U (6)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_06_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_06_Dir" type="DIRECTION" subtype="LINEAR"/>
<DataItem category="SAMPLE" id="Axis_06_FeedAct" name="FEEDRATE Asse U (6)" subType="ACTUAL" type="AXIS_FEEDRATE" units="MILLIMETER/SECOND"/>
<DataItem category="SAMPLE" id="Axis_06_FeedOver" name="FEEDRATE OVERRIDE Asse U (6)" subType="OVERRIDE" type="AXIS_FEEDRATE" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_06_AccelAct" name="Accelerazione asse U (6)" nativeUnits="MILLIMETER/SECOND^2" type="ACCELERATION" units="MILLIMETER/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_06_AccTime" name="Tempo impiego cumulato asse U (6)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_06_Battery" name="Valore batteria asse U (6)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_06_DistDone" name="Distanza TOTALE percorsa dall'asse U (6)" nativeUnits="MILLIMETER" type="LENGHT" units="METER"/>
<DataItem category="SAMPLE" id="Axis_06_InvDDone" name="Num cambi direzione asse U (6)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem type="TEMPERATURE" id="Temp_06_Value" category="SAMPLE" name="Sonda Temperatura asse 6" units="DEGREE" />
<DataItem category="CONDITION" id="Axis_06_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_06_AlarmPLC" type="LOGIC"/>
</DataItems>
</Linear>
<Rotary id="Axis_04" name="Asse B">
<DataItems>
<DataItem category="SAMPLE" id="Axis_04_PosAct" name="Pos asse J (4) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_04_PosTgt" name="Pos asse J (4) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_04_Load" name="Load asse J (4)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_04_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_04_Dir" type="DIRECTION" subtype="ROTARY"/>
<DataItem category="SAMPLE" id="Axis_04_FeedAct" name="ROT SPEED Asse J (4)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
<DataItem category="SAMPLE" id="Axis_04_FeedOver" name="ROT SPEED OVERRIDE Asse J (4)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_04_AccelAct" name="Accelerazione angolare asse J (4)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_04_AccTime" name="Tempo impiego cumulato asse J (4)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_04_Battery" name="Valore batteria asse J (4)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_04_DistDone" name="Num Giri asse J (4) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
<DataItem category="SAMPLE" id="Axis_04_InvDDone" name="Num cambi direzione asse J (4)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem category="CONDITION" id="Axis_04_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_04_AlarmPLC" type="LOGIC"/>
</DataItems>
</Rotary>
<Rotary id="Axis_05" name="Asse C (5)">
<DataItems>
<DataItem category="SAMPLE" id="Axis_05_PosAct" name="Pos asse K (5) actual" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_05_PosTgt" name="Pos asse K (5) target" nativeUnits="DEGREE" subType="COMMANDED" type="ANGLE" units="DEGREE"/>
<DataItem category="SAMPLE" id="Axis_05_Load" name="Load asse K (5)" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<DataItem category="EVENT" id="Axis_05_MainProc" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_IsMast" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_MastId" type="MESSAGE"/>
<DataItem category="EVENT" id="Axis_05_Dir" type="DIRECTION" subtype="ROTARY"/>
<DataItem category="SAMPLE" id="Axis_05_FeedAct" name="ROT SPEED Asse K (5)" subType="ACTUAL" type="ROTARY_VELOCITY" units="REVOLUTION/MINUTE"/>
<DataItem category="SAMPLE" id="Axis_05_FeedOver" name="ROT SPEED OVERRIDE Asse K (5)" subType="OVERRIDE" type="ROTARY_VELOCITY" nativeUnits="PERCENT" units="PERCENT"/>
<DataItem category="SAMPLE" id="Axis_05_AccelAct" name="Accelerazione angolare asse K (5)" nativeUnits="DEGREE/SECOND^2" type="ANGULAR_ACCELERATION" units="DEGREE/SECOND^2"/>
<DataItem category="SAMPLE" id="Axis_05_AccTime" name="Tempo impiego cumulato asse K (5)" nativeUnits="SECOND" type="ACCUMULATED_TIME" units="SECOND"/>
<DataItem category="SAMPLE" id="Axis_05_Battery" name="Valore batteria asse K (5)" nativeUnits="VOLT" type="VOLTAGE" units="VOLT"/>
<DataItem category="SAMPLE" id="Axis_05_DistDone" name="Num Giri asse k (5) nel periodo di rilevazione" nativeUnits="COUNT" type="LENGHT" units="COUNT"/>
<DataItem category="SAMPLE" id="Axis_05_InvDDone" name="Num cambi direzione asse K (5)" nativeUnits="COUNT" type="MESSAGE" units="COUNT"/>
<DataItem category="CONDITION" id="Axis_05_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Axis_05_AlarmPLC" type="LOGIC"/>
</DataItems>
</Rotary>
</Components>
</Axes>
<Controller id="cn1" name="controller">
<DataItems>
<DataItem category="EVENT" id="Message" type="MESSAGE"/>
<DataItem category="EVENT" id="E_STOP" type="EMERGENCY_STOP"/>
</DataItems>
<Components>
<Path id="Path_01" name="Path 01">
<DataItems>
<DataItem category="EVENT" id="Path_01_Type" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_ActiveAxes" type="ACTIVE_AXES"/>
<DataItem category="EVENT" id="Path_01_CodG_Act" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_SubMode" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_PartId" type="PART_ID"/>
<DataItem category="EVENT" id="Path_01_PZ_TOT" type="PART_COUNT"/>
<DataItem category="EVENT" id="Path_01_Cod_M" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_Cod_S" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_Cod_T" type="MESSAGE"/>
<DataItem category="EVENT" id="Path_01_RUN_MODE" type="CONTROLLER_MODE"/>
<DataItem category="EVENT" id="Path_01_EXE_MODE" type="EXECUTION"/>
<DataItem category="EVENT" id="Path_01_CurrProg" type="PROGRAM"/>
<DataItem category="EVENT" id="Path_01_CurrProg_RowNum" type="LINE"/>
<DataItem category="SAMPLE" id="Path_01_FeedRate" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="Path FEED"/>
<DataItem category="SAMPLE" id="Path_01_FeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="Path FEED Override"/>
<DataItem category="SAMPLE" id="Path_01_RapidOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="Path RAPID Override"/>
<DataItem category="SAMPLE" id="Path_01_PosActX" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione X"/>
<DataItem category="SAMPLE" id="Path_01_PosActY" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione Y"/>
<DataItem category="SAMPLE" id="Path_01_PosActZ" nativeUnits="MILLIMETER" subType="ACTUAL" type="PATH_POSITION" units="MILLIMETER" name="Posizione Z"/>
<DataItem category="SAMPLE" id="Path_01_PosActI" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo I"/>
<DataItem category="SAMPLE" id="Path_01_PosActJ" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo J"/>
<DataItem category="SAMPLE" id="Path_01_PosActK" nativeUnits="DEGREE" subType="ACTUAL" type="ANGLE" units="DEGREE" name="Angolo K"/>
<DataItem category="CONDITION" id="Path_01_AlarmCNC" type="SYSTEM"/>
<DataItem category="CONDITION" id="Path_01_AlarmPLC" type="LOGIC"/>
</DataItems>
</Path>
<!-- probabilmente da ri-spostare sotto PATH... -->
<Actuator id="UniOp_01" name ="Unità Operatrice 01">
<DataItems>
<DataItem category="SAMPLE" id="UnOp_01_Speed" nativeUnits="MILLIMETER/SECOND" type="PATH_FEEDRATE" units="MILLIMETER/SECOND" subType="ACTUAL" name="UnOp Speed"/>
<DataItem category="SAMPLE" id="UnOp_01_SpeedOverr" nativeUnits="PERCENT" type="PATH_FEEDRATE" units="PERCENT" subType="OVERRIDE" name="UnOp SPEED Override"/>
<DataItem category="EVENT" id="UnOp_01_ToolId" name="TOOL ID" type="TOOL_ASSET_ID"/>
<DataItem category="EVENT" id="UnOp_01_NumCU" name="Num Cambi Utensile effettuati" type="MESSAGE" units="COUNT"/>
<DataItem category="EVENT" id="UnOp_01_Status" type="ACTUATOR_STATE"/>
<DataItem category="EVENT" id="UnOp_01_VitaRes" name="Vita Residua Tool" type="MESSAGE" units="COUNT"/>
<DataItem category = "EVENT" id = "UnOp_01_VitaResType" name = "Tipologia misura Vita Residua Tool" type = "MESSAGE" />
<DataItem category="SAMPLE" id="UnOp_01_Load" name="Load sul PATH/UnOp" nativeUnits="PERCENT" type="LOAD" units="PERCENT"/>
<!-- cambiare in event... -->
<DataItem category="SAMPLE" id="UnOp_01_AccTime" name="Totale giri (migliaia) accumulati dal mandrino" type="COUNT"/>
</DataItems>
</Actuator>
</Components>
</Controller>
<Systems id="systems" name="systems">
<Components>
<Electric id="el" name="electric">
<DataItems>
<DataItem category="EVENT" id="p2" name="power" type="POWER_STATE"/>
</DataItems>
</Electric>
<Hydraulic id="hsys" name="hydraulic">
<!--<DataItems>
<DataItem category="CONDITION" id="hlow" type="LEVEL"/>
<DataItem category="CONDITION" id="hpres" type="PRESSURE"/>
<DataItem category="CONDITION" id="htemp" type="TEMPERATURE"/>
</DataItems>-->
</Hydraulic>
<Pneumatic id="PneumSys" name="Pneumatic Systems">
<Actuator id="VacPump_01" name ="Pompa 1">
<DataItems>
<DataItem category="EVENT" id="VacPump_01_Status" name="Stato Pompa 1" type="ACTUATOR_STATE"/>
<DataItem category="SAMPLE" id="VacPump_01_WrkTime" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
</DataItems>
</Actuator>
<Actuator id="VacPump_02" name ="Pompa 2">
<DataItems>
<DataItem category="EVENT" id="VacPump_02_Status" name="Stato Pompa 2" type="ACTUATOR_STATE"/>
<DataItem category="SAMPLE" id="VacPump_02_WrkTime" name="Tempo macchina in RUN" type="ACCUMULATED_TIME"/>
</DataItems>
</Actuator>
<Actuator id="VacAct_01" name ="Valvola vuoto 1">
<DataItems>
<DataItem category="EVENT" id="VacAct_01_Count" name="Contatore attivazioni valvola attuatore 1" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
<Actuator id="VacAct_02" name ="Valvola vuoto 2">
<DataItems>
<DataItem category="EVENT" id="VacAct_02_Count" name="Contatore attivazioni valvola attuatore 2" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
</Pneumatic>
<Coolant id="cool" name="coolant">
<!--<DataItems>
<DataItem category="CONDITION" id="clow" type="LEVEL"/>
<DataItem category="CONDITION" id="coolpres" type="PRESSURE"/>
<DataItem category="CONDITION" id="filter" type="x:FILTER"/>
<DataItem category="CONDITION" id="coolantmotor" type="ACTUATOR"/>
</DataItems>-->
<Actuator id="Cooler_01" name ="Cooler 1">
<DataItems>
<DataItem category="EVENT" id="Cooler_01_Status" name="Stato Cooler 1" type="ACTUATOR_STATE"/>
</DataItems>
</Actuator>
<Actuator id="Cooler_02" name ="Cooler 2">
<DataItems>
<DataItem category="EVENT" id="Cooler_02_Status" name="Stato Cooler 2" type="ACTUATOR_STATE"/>
</DataItems>
</Actuator>
</Coolant>
<Lubrication id="LubroSys" name="Lubricant Systems">
<Actuator id="Lubro_01" name ="Lubrorefrigerante 1">
<DataItems>
<DataItem category="EVENT" id="Lubro_01_Num" name="Contatore lubro 1" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
<Actuator id="Lubro_02" name ="Lubrorefrigerante 2">
<DataItems>
<DataItem category="EVENT" id="Lubro_02_Num" name="Contatore lubro 2" type="MESSAGE" units="COUNT"/>
</DataItems>
</Actuator>
</Lubrication>
</Components>
</Systems>
<Sensor id="sens1" name="Sensorunit">
<DataItems>
<!-- verificare di poterli spostare e siano 4, 1 x ogni asse lineare >>> SPOSTARE!!!!!! -->
<!-- <DataItem type="TEMPERATURE" id="Temp_04_Value" category="SAMPLE" name="Sonda Temperatura 4" units="DEGREE"/>
<DataItem type="TEMPERATURE" id="Temp_05_Value" category="SAMPLE" name="Sonda Temperatura 5" units="DEGREE"/> -->
<DataItem type="PRESSURE" id="Press_01_Value" category="SAMPLE" name="Pressostato 1" units="PASCAL"/>
<DataItem type="PRESSURE" id="Press_02_Value" category="SAMPLE" name="Pressostato 2" units="PASCAL"/>
</DataItems>
</Sensor>
</Components>
</Device>
</Devices>
</MTConnectDevices>
@@ -1,7 +1,7 @@
<?xml version="1.0" encoding="utf-8"?>
<AdapterConf xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<Version>1</Version>
<NomeAdapt>CMS_ADAPTER_FANUC</NomeAdapt>
<NomeAdapt>ADAPTER_FANUC</NomeAdapt>
<TipoAdapt>FANUC</TipoAdapt>
<ContOreMaccOn>0</ContOreMaccOn>
<ContOreMaccLav>0</ContOreMaccLav>
@@ -319,7 +319,7 @@
</dataRef>
<dataRef>
<Key>Axis_01_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_01_Dir</Key>
@@ -386,7 +386,7 @@
</dataRef>
<dataRef>
<Key>Axis_02_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_02_Dir</Key>
@@ -453,7 +453,7 @@
</dataRef>
<dataRef>
<Key>Axis_03_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_03_Dir</Key>
@@ -520,7 +520,7 @@
</dataRef>
<dataRef>
<Key>Axis_04_Type</Key>
<Value>0</Value>
<Value>ROTARY</Value>
</dataRef>
<dataRef>
<Key>Axis_04_Dir</Key>
@@ -587,7 +587,7 @@
</dataRef>
<dataRef>
<Key>Axis_05_Type</Key>
<Value>0</Value>
<Value>ROTARY</Value>
</dataRef>
<dataRef>
<Key>Axis_05_Dir</Key>
@@ -654,7 +654,7 @@
</dataRef>
<dataRef>
<Key>Axis_06_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_06_Dir</Key>
File diff suppressed because it is too large Load Diff

Before

Width:  |  Height:  |  Size: 148 KiB

After

Width:  |  Height:  |  Size: 148 KiB

@@ -12,10 +12,10 @@
10:x10
11:x100
12:x1000
13:
14:
15:
16:
13:MANUAL_JOG
14:MANUAL_REF
15:MANUAL_JOGINC
16:MANUAL_HANDLE
17:
18:
19:
@@ -1,90 +0,0 @@
[MACHINE]
MachineProject=c:\Kvara\Exe\ACCORD40FX_003455_R001701
[LIBRARY]
LibraryProject=.\LibDevices
[COLORS]
Default=C0A0A0
Black=101010
Red=FF0000
White=FFFFFF
Glass=FFFFFF
Yellow=FFFF00
Pattini=101010
Pinze=3030A0
Piedi=101010
Motori=101010
Guide=FFCCCC
Cono=5B3F0F
Asta=DD9829
;Tagliente=C59738
;Tagliente=STEEL
Tagliente=404040
Silver=C0C0C0
Steli=C0C0C0
Estrusi=C0C0C0
Gray=808080
Cappa=303030
Morsetto=FF8040
Piatto=6F6F6F
Blue=00FFFF
Tools=0000FF
;[SETUP]
;SimDelay=0
;UpdateFPS=0
;CollisionImagesPath=c:\kvara\XSimShared\CollImages\
;; 1=Virtual 2=NUM 3=Osai 4=EsaGv 5=File
;DeviceType=4
;;CleanSolids=1
;Title=Maestro SIM - Accord INT
;UseDateForCollisionsImages=1
;Language=it-IT
;Debug=1
[NC]
;BufferFileName=.\Integra1.MEM
UseHexPlcAddr=0
; formato 1=NUM 2=OSAI 3=ESA
; indirizzo del primo byte di stato
StatusAddress=SIMWRITE[0]
StatusNumber=401
; indirizzo di memoria del primo byte di scrittura dati
CommandsAddress=SIMREAD[0]
CommandsNumber=10
; indirizzo di memoria AreaV
VAreaAddress=V
VAreaNumber=10
; area EOK
EOKAreaAddress=EOK
EOKAreaNumber=10
; area ETK
ETKAreaAddress=ETK
ETKAreaNumber=10
; indirizzo di memoria AreaV
PlcErrAreaAddress=V
PlcErrAreaNumber=10
; offset del registro per l'indice di collisione
CollisionIndex=6.L
; ritardo nella lettura dal plc
PlcDelay=50
; <-- deve essere produzione?!? o che valore?
SysLink=SIMULATO
SysDefCn=C:\KVARA\DISCOI
;BufferFileName=
;MemoryFormat=2
; modo sincronizzato con il plc
;PlcSyncAddress=2103
[XILOG]
Enable=1
SharedFolder=c:\kvara\XSimShared\
[DISPLAY]
HideShowModeButtons=1
HideOrthographicMode=1
HideOptionsTab=1
@@ -1,5 +0,0 @@
[.ShellClassInfo]
InfoTip=Questa cartella è condivisa online.
IconFile=C:\Program Files (x86)\Google\Drive\googledrivesync.exe
IconIndex=16
Binary file not shown.
Binary file not shown.
-385
View File
@@ -1,385 +0,0 @@
<?xml version="1.0"?>
<doc>
<assembly>
<name>
CMSCncLib
</name>
</assembly>
<members>
<member name="T:CMSCncLib.My.Resources.Resources">
<summary>
A strongly-typed resource class, for looking up localized strings, etc.
</summary>
</member>
<member name="P:CMSCncLib.My.Resources.Resources.ResourceManager">
<summary>
Returns the cached ResourceManager instance used by this class.
</summary>
</member>
<member name="P:CMSCncLib.My.Resources.Resources.Culture">
<summary>
Overrides the current thread's CurrentUICulture property for all
resource lookups using this strongly typed resource class.
</summary>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_GetCncSeries">
<summary>
Get class series of CNC: 16 or 30
</summary>
<returns>Series</returns>
<remarks>After, use Is16Series and Is30Series for discriminate</remarks>
</member>
<member name="M:CMSCncLib.CNC.FANUC.GetStaticData">
<summary>
Legge le memorie di configurazione dal cn
</summary>
</member>
<member name="M:CMSCncLib.CNC.FANUC.GetActivePath">
<summary>
Legge il numero del processo attivo
</summary>
<returns>Processo attivo</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Boolean(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Int32,System.Boolean@)">
<summary>
Legge o scrive Boolean da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="MemBit">Bit della memoria</param>
<param name="Value">Valore da scrivere su scrittura e letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Byte(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Byte[]@)">
<summary>
Legge o scrive Byte da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Byte(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Byte@)">
<summary>
Legge o scrive Byte da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Valore da scrivere su scrittura o letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Word(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.UInt16[]@)">
<summary>
Legge o scrive Word da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Short(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Int16[]@)">
<summary>
Legge o scrive Short da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Word(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.UInt16@)">
<summary>
Legge o scrive Word da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Valore da scrivere su scrittura o letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Short(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Int16@)">
<summary>
Legge o scrive Short da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Valore da scrivere su scrittura o letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_DWord(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.UInt32[]@)">
<summary>
Legge DWord da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_DWord(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.UInt32@)">
<summary>
Legge DWord da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Valore da scrivere su scrittura o letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Integer(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Int32[]@)">
<summary>
Legge Integer da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Integer(System.Boolean,CMSCncLib.CNC.FANUC.MemType,System.Int32,System.Int32@)">
<summary>
Legge Integer da MEMORIE PLC
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemType">Tipo di memoria Fanuc</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Value">Valore da scrivere su scrittura o letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_ToolOffset(System.Boolean,System.Int32,System.Double@,System.Double@,System.Double@,System.Double@)">
<summary>
Legge o scrive Length and Radius Offset da tabella Utensili CN
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="ToolOffsetNumber">Numero dell'offset utensile</param>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_Clear_ToolOffsets">
<summary>
Cancella la tabella Utensili CN
</summary>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Param_Integer(System.Boolean,System.Int32,System.Int32,System.Int32,System.Object[]@)">
<summary>
Legge o scrive Parametri Interi
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="Axis">0: assigns no axis, -1: assigns all axes </param>
<param name="ParamIndex">Indice di memoria</param>
<param name="Size">1 byte, 2 word, 3 dword</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Param_Integer(System.Boolean,System.Int32,System.Int32,System.Object@)">
<summary>
Legge o scrive Parametri Interi
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MemIndex">Indice di memoria</param>
<param name="Size">1 byte, 2 word, 3 dword</param>
<param name="Value">Valore da scrivere su scrittura o letto su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Macro_Short(System.Boolean,System.Int32,System.Int16[]@)">
<summary>
Legge o scrive le variabile Custom Macro
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MacroIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Macro_Short(System.Boolean,System.Int32,System.Int16@)">
<summary>
Legge o scrive le variabile Custom Macro
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MacroIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Macro_Double(System.Boolean,System.Int32,System.Double[]@)">
<summary>
Legge o scrive le variabile Custom Macro
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MacroIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_Macro_Double(System.Boolean,System.Int32,System.Double@)">
<summary>
Legge o scrive le variabile Custom Macro
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MacroIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_PCodeMacro_Short(System.Boolean,System.Int32,System.Int16[]@)">
<summary>
Legge o scrive le variabile P Code Macro
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MacroIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.FANUC.F_RW_PCodeMacro_Short(System.Boolean,System.Int32,System.Int16@)">
<summary>
Legge o scrive le variabile P Code Macro
</summary>
<param name="bWrite">Se True SCRIVE, se False LEGGE</param>
<param name="MacroIndex">Indice di memoria</param>
<param name="Value">Matrice di valori da scrivere su scrittura o letti su lettura</param>
<returns>True se andata a buon fine</returns>
</member>
<member name="M:CMSCncLib.CNC.CNC.GetDataMaintenance">
<summary>
Legge il valore del tempo di lavorazione totale del CN
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.GetStaticData">
<summary>
Legge le memorie di configurazione dal cn
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.SetCncWindowSize">
<summary>
Stabilisce la risoluzione CncWindow
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.RunCnc">
<summary>
Esegue l'applicazione CNC
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.CloseCnc">
<summary>
Chiude l'applicazione CNC
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.FindCncWindow">
<summary>
Cerca la finestra CNC e restituisce True se la trova
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.CncIsIconic">
<summary>
Restituisce True se la finestra Cnc è ridotta a icona
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.CncIsZoomed">
<summary>
Restituisce True se la finestra Cnc è massimizzata a tutto schermo
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.MinimizeCnc">
<summary>
Riduce a icona la finestra CNC
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.NormalizeCnc">
<summary>
Mostra a dimensioni normali la finestra CNC
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.SetCncFocus">
<summary>
Setta il focus sulla finestra CNC
</summary>
</member>
<member name="M:CMSCncLib.CNC.CNC.MoveCnc">
<summary>
Setta il focus sulla finestra CNC
</summary>
</member>
<member name="P:CMSCncLib.Config.Options.Machine_Enabled">
<summary>Maintenance Machine</summary>
</member>
<member name="P:CMSCncLib.Config.Options.Maintenance_Enabled">
<summary>Opzione Maintenance</summary>
</member>
<member name="P:CMSCncLib.Config.Options.OpPanel_Enabled">
<summary>Opzione OpPanel</summary>
</member>
<member name="P:CMSCncLib.Config.Options.Launch_Enabled">
<summary>Opzione Launch</summary>
</member>
<member name="P:CMSCncLib.Config.Options.TcpSocket_Enabled">
<summary>Opzione TcpSocket</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Enabled">
<summary>Opzione ToolTable</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Famiglie">
<summary>Opzione Famiglie</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Vita">
<summary>Opzione Vita</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Vita_S">
<summary>Opzione Vita a Tempo</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Vita_N">
<summary>Opzione Vita a Cicli o Colpi</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Vita_M">
<summary>Opzione Vita a Profilo</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_AttrezzaggioAutomatico">
<summary>Opzione Attrezzaggio Automatico</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_PercorsoAutoadattativo">
<summary>Opzione Percorso Autoadattativo</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Multiprofilo">
<summary>Opzione Multiprofilo</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_CompensazioneDinamica">
<summary>Opzione Compensazione Dinamica</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Offset">
<summary>Opzione Offset</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_FeedMax">
<summary>Opzione FeedMax</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Gamme">
<summary>Opzione Gamme</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Manine">
<summary>Opzione Manine</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_MaxToolsManaged">
<summary>Massimo numero di utensili gestibili</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Inch">
<summary>Opzione gestione in Pollici</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_Diameter">
<summary>Opzione gestione Diametro</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_AttrezzaggioInRun">
<summary>Opzione modifica con macchina in RUN</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_AttrezzaggioAssistito">
<summary>Opzione Attrezzaggio magazzini inaccessibili tramite macchina</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_SharedDB">
<summary>Opzione magazzino utensili condiviso tra più macchine</summary>
</member>
<member name="P:CMSCncLib.Config.Options.ToolTable_AllowRemote">
<summary>Opzione AllowRemote Tool Table</summary>
</member>
<member name="M:CMSCncLib.General.ReplaceNewLine(System.String)">
<summary>
Sostituisce il carattere | con un carattere speciale di ritorno a capo
</summary>
</member>
</members>
</doc>
Binary file not shown.
Binary file not shown.
@@ -1,83 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<startup>
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.5.2" />
</startup>
<appSettings>
<add key="appName" value="MTConnect Adapter" />
<!--gestione TIMERS e periodi multipli x thread lenti-->
<add key="startTimerMs" value="250" />
<add key="timerIntMs" value="5" /><!--invio da adapter ad agent: 5ms-->
<add key="fastCount" value="20" /><!--100ms-->
<add key="normCount" value="50" /><!--250ms-->
<add key="slowCount" value="500" /><!--2.5 sec-->
<add key="alarmSyncCount" value="6000" /><!--30 sec-->
<!--parametri gestione watchdog-->
<add key="maxAdapterLockSec" value="5" />
<!--AREA CONF IP FANUC-->
<!--SIMULATORE LOCALE
IP LOOPBACK: 192.168.211.5/255.255.255.0
ipFanuc = "192.168.211.5"-->
<!--<add key ="ipFanuc" value="192.168.211.5" />-->
<!--SIM PC
IP ETH: 192.168.139.201/255.255.255.0
ipFanuc = "192.168.139.100"-->
<!--<add key="ipFanuc" value="192.168.139.100" />-->
<add key="ipFanuc" value="192.168.139.1" />
<!--PRODUZIONE
IP ETH: 192.168.139.201/255.255.255.0
ipFanuc = "192.168.139.1"-->
<!--<add key ="ipFanuc" value="192.168.139.1" />-->
<add key="recTime" value="true" />
<add key="verbose" value="true" />
<add key="logAll" value="false" />
<add key="autoLoadConf" value="true"/>
<add key="defaultConfFile" value="CMS_FANUC.xml"/>
<add key="defaultPersLayerFile" value="PersistData.mtc" />
<add key="defaultEsaFile" value="EsaKvara.ini" />
<add key="autoStartOnLoad" value="true" />
<add key="openDumpOnStart" value="false"/>
<add key="startMinimized" value="true"/>
<add key="autoSaveSec" value="60" />
<add key="XmlHistFilePath" value="c:\IOT\log" />
<add key="testCharSep" value="|" />
<!--percorso file scambio dati "lenti" e conf MaintData memory area -->
<add key="GeneralStatusFilePath" value="CmsGeneralStatus.mtc" />
<add key="CmsMaintDataConfFilePath" value="CmsMaintDataConf.txt" />
<add key="CmsStatusDataConfFilePath" value="CmsStatusDataConf.txt" />
<add key="ScmProdFile" value="SCM_prodFile.pro" />
<add key="fattdecimale" value="1000" />
<add key="fattConvDistAssi" value="1000" />
<add key="D1_NAME" value="CMS-ARES-SIM" />
<add key="D1_ID" value="demo_123456" />
<add key="D1_UUID" value="000123456" />
<add key="D1_PROGRAM" value="PROG_DEMO_01" />
<add key="PartID" value="Prod_0001" />
<!--conf file-->
<add key="adapterConfPath" value="AdapterConf" />
<add key="AlarmList" value="AlarmList.txt" />
<add key="SubMode" value="SubMode.txt" />
<!--gestione trigger eventi da allarmi-->
<add key="eStopCode" value="152" />
<!--gestione watchdog CMS-->
<add key="sendWatchDog" value="true" />
</appSettings>
</configuration>
Binary file not shown.
@@ -1,83 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<startup>
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.5.2" />
</startup>
<appSettings>
<add key="appName" value="MTConnect Adapter" />
<!--gestione TIMERS e periodi multipli x thread lenti-->
<add key="startTimerMs" value="250" />
<add key="timerIntMs" value="5" /><!--invio da adapter ad agent: 5ms-->
<add key="fastCount" value="20" /><!--100ms-->
<add key="normCount" value="50" /><!--250ms-->
<add key="slowCount" value="500" /><!--2.5 sec-->
<add key="alarmSyncCount" value="6000" /><!--30 sec-->
<!--parametri gestione watchdog-->
<add key="maxAdapterLockSec" value="5" />
<!--AREA CONF IP FANUC-->
<!--SIMULATORE LOCALE
IP LOOPBACK: 192.168.211.5/255.255.255.0
ipFanuc = "192.168.211.5"-->
<!--<add key ="ipFanuc" value="192.168.211.5" />-->
<!--SIM PC
IP ETH: 192.168.139.201/255.255.255.0
ipFanuc = "192.168.139.100"-->
<!--<add key="ipFanuc" value="192.168.139.100" />-->
<add key="ipFanuc" value="192.168.139.1" />
<!--PRODUZIONE
IP ETH: 192.168.139.201/255.255.255.0
ipFanuc = "192.168.139.1"-->
<!--<add key ="ipFanuc" value="192.168.139.1" />-->
<add key="recTime" value="true" />
<add key="verbose" value="true" />
<add key="logAll" value="false" />
<add key="autoLoadConf" value="true"/>
<add key="defaultConfFile" value="CMS_FANUC.xml"/>
<add key="defaultPersLayerFile" value="PersistData.mtc" />
<add key="defaultEsaFile" value="EsaKvara.ini" />
<add key="autoStartOnLoad" value="true" />
<add key="openDumpOnStart" value="false"/>
<add key="startMinimized" value="true"/>
<add key="autoSaveSec" value="60" />
<add key="XmlHistFilePath" value="c:\IOT\log" />
<add key="testCharSep" value="|" />
<!--percorso file scambio dati "lenti" e conf MaintData memory area -->
<add key="GeneralStatusFilePath" value="CmsGeneralStatus.mtc" />
<add key="CmsMaintDataConfFilePath" value="CmsMaintDataConf.txt" />
<add key="CmsStatusDataConfFilePath" value="CmsStatusDataConf.txt" />
<add key="ScmProdFile" value="SCM_prodFile.pro" />
<add key="fattdecimale" value="1000" />
<add key="fattConvDistAssi" value="1000" />
<add key="D1_NAME" value="CMS-ARES-SIM" />
<add key="D1_ID" value="demo_123456" />
<add key="D1_UUID" value="000123456" />
<add key="D1_PROGRAM" value="PROG_DEMO_01" />
<add key="PartID" value="Prod_0001" />
<!--conf file-->
<add key="adapterConfPath" value="AdapterConf" />
<add key="AlarmList" value="AlarmList.txt" />
<add key="SubMode" value="SubMode.txt" />
<!--gestione trigger eventi da allarmi-->
<add key="eStopCode" value="152" />
<!--gestione watchdog CMS-->
<add key="sendWatchDog" value="true" />
</appSettings>
</configuration>
@@ -1,11 +0,0 @@
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0">
<assemblyIdentity version="1.0.0.0" name="MyApplication.app"/>
<trustInfo xmlns="urn:schemas-microsoft-com:asm.v2">
<security>
<requestedPrivileges xmlns="urn:schemas-microsoft-com:asm.v3">
<requestedExecutionLevel level="asInvoker" uiAccess="false"/>
</requestedPrivileges>
</security>
</trustInfo>
</assembly>
-44
View File
@@ -1,44 +0,0 @@
<?xml version="1.0" encoding="utf-8" ?>
<nlog xmlns="http://www.nlog-project.org/schemas/NLog.xsd"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.nlog-project.org/schemas/NLog.xsd NLog.xsd"
autoReload="true"
throwExceptions="false"
internalLogLevel="Off" internalLogFile="c:\temp\nlog-internal.log" >
<!-- optional, add some variabeles
https://github.com/nlog/NLog/wiki/Configuration-file#variables
-->
<variable name="myvar" value="myvalue"/>
<!--
See https://github.com/nlog/nlog/wiki/Configuration-file
for information on customizing logging rules and outputs.
-->
<targets>
<!--
add your targets here
See https://github.com/nlog/NLog/wiki/Targets for possible targets.
See https://github.com/nlog/NLog/wiki/Layout-Renderers for the possible layout renderers.
-->
<!--
Write events to a file with the date in the filename.
<target xsi:type="File" name="f" fileName="${basedir}/logs/${shortdate}.log"
layout="${longdate} ${uppercase:${level}} ${message}" />
-->
<target xsi:type="File" name="f" fileName="${basedir}/logs/${shortdate}.log" layout="${longdate} ${uppercase:${level}} ${message}" />
</targets>
<rules>
<!-- add your logging rules here -->
<!--
Write all events with minimal level of Debug (So Debug, Info, Warn, Error and Fatal, but not Trace) to "f"
<logger name="*" minlevel="Debug" writeTo="f" />
-->
<logger name="*" minlevel="Debug" writeTo="f" />
</rules>
</nlog>
Binary file not shown.
File diff suppressed because it is too large Load Diff
Binary file not shown.
Binary file not shown.
@@ -1,8 +0,0 @@
07,00,00,00000
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST1.PGM,,1600,600,50,08,14,23,08,18,47,00,03,03,00,04,05,1,00,01,31,50
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST1.PGM,,1600,600,50,08,19,39,08,39,16,00,20,37,00,20,40,4,00,02,37,00
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST1.PGM,,1600,600,50,08,40,11,09,40,53,00,03,50,01,00,53,12,00,03,50,00
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST2.PGM,,1600,600,50,09,52,41,09,57,23,00,05,25,00,05,45,1,00,04,55,00
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST2.PGM,,1600,600,50,10,01,04,13,05,49,03,01,58,03,02,45,36,00,07,59,96
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST3.PGM,,1600,600,50,14,18,24,16,48,49,02,28,58,02,30,45,15,00,07,59,96
AB,C:\Programme\Scm Group\Xilog Plus\Job\PRGCANTEST4.PGM,,1600,600,50,16,50,14,19,00,49,02,05,58,02,10,45,13,00,07,59,96
@@ -1 +0,0 @@
07,00,00,00000
@@ -1,5 +0,0 @@
[.ShellClassInfo]
InfoTip=Questa cartella è condivisa online.
IconFile=C:\Program Files (x86)\Google\Drive\googledrivesync.exe
IconIndex=16
@@ -1 +0,0 @@

@@ -1,5 +0,0 @@
[.ShellClassInfo]
InfoTip=Questa cartella è condivisa online.
IconFile=C:\Program Files (x86)\Google\Drive\googledrivesync.exe
IconIndex=16
File diff suppressed because it is too large Load Diff
@@ -1,81 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<startup>
<supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.5.2" />
</startup>
<appSettings>
<add key="appName" value="MTConnect Adapter" />
<!--gestione TIMERS e periodi multipli x thread lenti-->
<add key="startTimerMs" value="250" />
<add key="timerIntMs" value="5" /><!--invio da adapter ad agent: 10ms-->
<add key="fastCount" value="20" /><!--100ms-->
<add key="normCount" value="50" /><!--250ms-->
<add key="slowCount" value="500" /><!--2.5 sec-->
<add key="alarmSyncCount" value="6000" /><!--30 sec-->
<!--parametri gestione watchdog-->
<add key="maxAdapterLockSec" value="5" />
<!--AREA CONF IP FANUC-->
<!--SIMULATORE LOCALE
IP LOOPBACK: 192.168.211.5/255.255.255.0
ipFanuc = "192.168.211.5"-->
<!--<add key ="ipFanuc" value="192.168.211.5" />-->
<!--SIM PC
IP ETH: 192.168.139.201/255.255.255.0
ipFanuc = "192.168.139.100"-->
<!--<add key="ipFanuc" value="192.168.139.100" />-->
<add key="ipFanuc" value="192.168.139.1" />
<!--PRODUZIONE
IP ETH: 192.168.139.201/255.255.255.0
ipFanuc = "192.168.139.1"-->
<!--<add key ="ipFanuc" value="192.168.139.1" />-->
<add key="recTime" value="true" />
<add key="verbose" value="true" />
<add key="logAll" value="false" />
<add key="autoLoadConf" value="true"/>
<add key="defaultConfFile" value="CMS_FANUC.xml"/>
<add key="defaultPersLayerFile" value="PersistData.mtc" />
<add key="defaultEsaFile" value="EsaKvara.ini" />
<add key="autoStartOnLoad" value="true" />
<add key="openDumpOnStart" value="false"/>
<add key="startMinimized" value="true"/>
<add key="autoSaveSec" value="60" />
<add key="XmlHistFilePath" value="c:\CMS\MTC\log" />
<add key="testCharSep" value="|" />
<!--percorso file scambio dati "lenti" e conf MaintData memory area -->
<add key="GeneralStatusFilePath" value="CmsGeneralStatus.mtc" />
<add key="CmsMaintDataConfFilePath" value="CmsMaintDataConf.txt" />
<add key="CmsStatusDataConfFilePath" value="CmsStatusDataConf.txt" />
<add key="ScmProdFile" value="SCM_prodFile.pro" />
<add key="fattdecimale" value="1000" />
<add key="fattConvDistAssi" value="1000" />
<add key="D1_NAME" value="CMS-ARES-8006" />
<add key="D1_ID" value="8006" />
<add key="D1_UUID" value="ARES00008006" />
<add key="D1_PROGRAM" value="ND" />
<add key="PartID" value="ND" />
<!--conf file-->
<add key="adapterConfPath" value="AdapterConf" />
<add key="AlarmList" value="AlarmList.txt" />
<add key="SubMode" value="SubMode.txt" />
<!--gestione trigger eventi da allarmi-->
<add key="eStopCode" value="152" />
</appSettings>
</configuration>
@@ -1,8 +1,8 @@
<?xml version="1.0" encoding="utf-8"?>
<AdapterConf xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<Version>1</Version>
<NomeAdapt>SCM_ADAPTER_ESA</NomeAdapt>
<TipoAdapt>HMI_ESA</TipoAdapt>
<NomeAdapt>ADAPTER_FANUC</NomeAdapt>
<TipoAdapt>FANUC</TipoAdapt>
<ContOreMaccOn>0</ContOreMaccOn>
<ContOreMaccLav>0</ContOreMaccLav>
<VacuumPump>
@@ -319,7 +319,7 @@
</dataRef>
<dataRef>
<Key>Axis_01_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_01_Dir</Key>
@@ -386,7 +386,7 @@
</dataRef>
<dataRef>
<Key>Axis_02_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_02_Dir</Key>
@@ -453,7 +453,7 @@
</dataRef>
<dataRef>
<Key>Axis_03_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_03_Dir</Key>
@@ -520,7 +520,7 @@
</dataRef>
<dataRef>
<Key>Axis_04_Type</Key>
<Value>0</Value>
<Value>ROTARY</Value>
</dataRef>
<dataRef>
<Key>Axis_04_Dir</Key>
@@ -587,7 +587,7 @@
</dataRef>
<dataRef>
<Key>Axis_05_Type</Key>
<Value>0</Value>
<Value>ROTARY</Value>
</dataRef>
<dataRef>
<Key>Axis_05_Dir</Key>
@@ -654,7 +654,7 @@
</dataRef>
<dataRef>
<Key>Axis_06_Type</Key>
<Value>0</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_06_Dir</Key>
File diff suppressed because it is too large Load Diff
@@ -0,0 +1,32 @@
# Commenti con cancelletto, struttura un variabile per riga, tipo chiave|valore (occhio che il separatore è configurato da .cofig come "testCharSep"); spazi e tabulazioni dovrei trimmarli in acquisizione (qui inseriti per comodità di lettura)
001|ACC_TIME |HOURS
002|ACC_TIME_WORK |HOURS
003|Path_01_PZ_TOT |COUNT
004|Axis_01_DistDone |METER
005|Axis_01_Invers |COUNT
006|Axis_02_DistDone |METER
007|Axis_02_Invers |COUNT
008|Axis_03_DistDone |METER
009|Axis_03_Invers |COUNT
010|Axis_04_DistDone |COUNT
011|Axis_04_Invers |COUNT
012|Axis_05_DistDone |COUNT
013|Axis_05_Invers |COUNT
014|Axis_06_DistDone |METER
015|Axis_06_Invers |COUNT
016|UnOp_01_AccTime |COUNT
017|VacPump_01_WrkTime |HOURS
018|VacPump_02_WrkTime |HOURS
019|VacAct_01_Count |COUNT
020|VacAct_02_Count |COUNT
021|Lubro_01_Num |COUNT
022|SlittaTastatore_Count |COUNT
023|SlittaMagazzino_01_Count |COUNT
024|ProtMagazzino_01_Count |COUNT
025|UnOp_01_NumCambiUT |COUNT
026|Axis_01_AccTime |COUNT
027|Axis_02_AccTime |COUNT
028|Axis_03_AccTime |COUNT
029|Axis_04_AccTime |COUNT
030|Axis_05_AccTime |COUNT
031|Axis_06_AccTime |COUNT
@@ -0,0 +1,9 @@
# Commenti con "#", elenco tipo codice:valore delle causali di HALT
001:[COD 001] - PRODUZIONE
002:[COD 002] - SETUP
003:[COD 003] - MACCHINA_DISPONIBILE
004:[COD 004] - MANUTENZIONE
005:[COD 005] - PULIZIA
006:[COD 006] - REGOLAZIONI
007:[COD 007] - PIPPO
Binary file not shown.

After

Width:  |  Height:  |  Size: 148 KiB

@@ -0,0 +1,7 @@
# Commenti con cancelletto, struttura un variabile per riga, tipo chiave|valore (occhio che il separatore è configurato da .cofig come "testCharSep"); spazi e tabulazioni dovrei trimmarli in acquisizione (qui inseriti per comodità di lettura)
001|PROTECTION_STATUS |BIT
002|VacPump_01_Status |BIT
003|VacPump_02_Status |BIT
004|Cooler_01_Status |BIT
005|Cooler_02_Status |BIT
006|UnOp_01_Status |BIT
@@ -0,0 +1,33 @@
# Commenti con "#", elenco tipo codice:valore delle label dei SUB_MODE di FANUC
0:DNC
1:Blk/Blk
2:BlkDel
3:OpStop
4:Teach
5:Prg Test
6:MLock
7:DryRun
8:Restart
9:x1
10:x10
11:x100
12:x1000
13:MANUAL_JOG
14:MANUAL_REF
15:MANUAL_JOGINC
16:MANUAL_HANDLE
17:
18:
19:
20:Asse selezionato 1
21:Asse selezionato 2
22:Asse selezionato 3
23:Asse selezionato 4
24:Asse selezionato 5
25:Asse selezionato 6
26:Asse selezionato 7
27:Asse selezionato 8
28:Asse selezionato 9
29:Asse selezionato 10
30:Asse selezionato 11
31:Asse selezionato 12
@@ -0,0 +1,4 @@
# Commenti con cancelletto, struttura un variabile per riga, tipo chiave|valore (occhio che il separatore è configurato da .config come "testCharSep")
OperatorId|CMS Operator 001
Path_01_CurrProg|WrkProgram_123
Path_01_PartId|P000123
+9 -7
View File
@@ -1,6 +1,6 @@
# --------------------------------------------------------------
# Script installazione MTConnect Agent + MTConnect ADAPTER
# S.E.L. e G.A.R. - Steamware 2016.10.17
# S.E.L. e G.A.R. - Steamware 2016.12.09
# --------------------------------------------------------------
$ErrorActionPreference = "Stop" # comportamento x errori minori
@@ -14,9 +14,10 @@ cd $scriptPath
Write-Host "--------------------"
Write-Host "- ADAPTER AMMESSI"
Write-Host "--------------------"
Write-Host "1 - FANUC CMS"
#Write-Host "2 - ESA SCM"
$adapter = read-host "Prego scegliere tipologia di ADAPTER da installare (default: 1 = Fanuc)"
Write-Host "1 - FANUC (CMS)"
Write-Host "2 - ESAGV (SCM)"
Write-Host "3 - SIEMENS (CMS)"
$adapter = read-host "Prego scegliere tipologia di ADAPTER da installare (default: 1 = FANUC)"
if(!$adapter)
{
$adapter = "1"
@@ -27,7 +28,8 @@ $AdpDir = ""
switch($adapter)
{
1 { $AdpDir = "FANUC" }
#2 { $AdpDir = "ESA" }
2 { $AdpDir = "ESA" }
3 { $AdpDir = "SIEMENS" }
default { $AdpDir = "FANUC" }
}
@@ -49,7 +51,7 @@ Copy-Item -Recurse ".\$AdpDir\ADAPTER" "$tgtFolder\ADAPTER"
# Fase 3: copia file di conf specifica
Start-Sleep -s 1
Write-Host "Sto copiando files configurazioen matricola in '$tgtFolder'"
Copy-Item -Recurse ".\$AdpDir\ConfMacchina\*.*" "$tgtFolder\ADAPTER\"
Copy-Item -Recurse ".\$AdpDir\DATA\*.*" "$tgtFolder\ADAPTER\"
# Fase 4: copia dell'agent
Start-Sleep -s 1
@@ -58,7 +60,7 @@ Copy-Item -Recurse ".\AGENT\" "$tgtFolder\AGENT\"
# copio anche le conf dell'agent!
Start-Sleep -s 1
Copy-Item -Recurse ".\ConfAgent\*.*" "$tgtFolder\AGENT\"
Copy-Item -Recurse ".\DATA\*.*" "$tgtFolder\AGENT\"
# Fase 4: registrazione dell'agent
+12 -6
View File
@@ -1,16 +1,22 @@
#------------------------------------------------------------------
# MTConnect ADAPTER ed AGENT CMS/SCM
#------------------------------------------------------------------
1. Modalità avvio PowerShell
Start -> Windows Powershell -> Esegui Come amministratore
Set-ExecutionPolicy -Scope Process -ExecutionPolicy unrestricted
Nella console di Powershell spostarsi nella dir di installazione e digitare .\InstallerMTC.ps1
dare Enter
2. Istruzioni installazione
- E' necessario scegliere il tipo di controller e quindi la build da installare (es: FANUC/Build_1611.62) e COPIARLA/RINOMINARLA come ADAPTER (FANUC/Build_1611.62 --> FANUC/ADAPTER)
- Eventuali personalizzazioni nei file di configurazione vanno salvati (secondo la struttura desiderata) nella folder CNC/DATA (es FANUC/DATA)
- Nella console di Powershell spostarsi nella dir di installazione e digitare .\InstallerMTC.ps1
- Premere Enter
es.
3. Esempio installazione
C:
CD \Installer CMQ MTC
.\InstallerMTC.ps1
ENTER
ENTER
@@ -1,8 +1,10 @@
<?xml version="1.0" encoding="utf-8"?>
<AdapterConf xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<Version>1</Version>
<NomeAdapt>CMS_ADAPTER_00</NomeAdapt>
<TipoAdapt>DEMO</TipoAdapt>
<NomeAdapt>ADAPTER_FANUC</NomeAdapt>
<TipoAdapt>FANUC</TipoAdapt>
<ContOreMaccOn>0</ContOreMaccOn>
<ContOreMaccLav>0</ContOreMaccLav>
<VacuumPump>
<element>
<ident>VacPump_01</ident>
@@ -11,7 +13,11 @@
<dataRefList>
<dataRef>
<Key>VacPump_01_Status</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>VacPump_01_WrkTime</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -22,7 +28,11 @@
<dataRefList>
<dataRef>
<Key>VacPump_02_Status</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>VacPump_02_WrkTime</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -32,10 +42,10 @@
<ident>VacAct_01</ident>
<alias>Attuatore vuoto 1</alias>
<fonte>Random</fonte>
<dataRefList>ù
<dataRefList>
<dataRef>
<Key>VacAct_01_Count</Key>
<Value>0#15</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -46,7 +56,7 @@
<dataRefList>
<dataRef>
<Key>VacAct_02_Count</Key>
<Value>0#15</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -59,7 +69,7 @@
<dataRefList>
<dataRef>
<Key>Lubro_01_Num</Key>
<Value>0#15</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -70,7 +80,7 @@
<dataRefList>
<dataRef>
<Key>Lubro_02_Num</Key>
<Value>0#15</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -83,7 +93,7 @@
<dataRefList>
<dataRef>
<Key>Cooler_01_Status</Key>
<Value>0#3</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -94,7 +104,7 @@
<dataRefList>
<dataRef>
<Key>Cooler_02_Status</Key>
<Value>0#3</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -107,7 +117,7 @@
<dataRefList>
<dataRef>
<Key>Press_01_Value</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -118,7 +128,7 @@
<dataRefList>
<dataRef>
<Key>Press_02_Value</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -131,7 +141,7 @@
<dataRefList>
<dataRef>
<Key>Temp_01_Value</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -142,7 +152,7 @@
<dataRefList>
<dataRef>
<Key>Temp_02_Value</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -155,63 +165,63 @@
<dataRefList>
<dataRef>
<Key>Path_01_FeedRate</Key>
<Value>INT#D8888.0</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_FeedOverr</Key>
<Value>INT#D8888.0</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_RapidOverr</Key>
<Value>INT#D8888.0</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PosActX</Key>
<Value>FLOAT#D7777.0</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PosActY</Key>
<Value>FLOAT#D7777.1</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PosActZ</Key>
<Value>FLOAT#D7777.2</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PosActI</Key>
<Value>FLOAT#D7777.3</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PosActJ</Key>
<Value>FLOAT#D7777.4</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PosActK</Key>
<Value>FLOAT#D7777.5</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_Type</Key>
<Value>FLAG#R10528.12</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PartId</Key>
<Value>INT#D9999</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_PZ_TOT</Key>
<Value>INT#D9999</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_Cod_M</Key>
<Value>STROBE#R10520.0</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_Cod_S</Key>
<Value>STROBE#R10520.1</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_Cod_T</Key>
<Value>STROBE#R10520.2</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_RUN_MODE</Key>
@@ -223,23 +233,23 @@
</dataRef>
<dataRef>
<Key>Path_01_CurrProg</Key>
<Value>STRING#D0000</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_CurrProg_RowNum</Key>
<Value>INT#D0001.0</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_ActiveAxes</Key>
<Value>CLASS</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_CodG_Act</Key>
<Value>CLASS</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Path_01_SubMode</Key>
<Value>FLAG#R10528.0:R10531.7</Value>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -252,31 +262,39 @@
<dataRefList>
<dataRef>
<Key>UnOp_01_ToolId</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_NumCU</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_Status</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_VitaRes</Key>
<Value>24#31</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_Speed</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_SpeedOverr</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_AccTime</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>UnOp_01_VitaResType</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -289,55 +307,63 @@
<dataRefList>
<dataRef>
<Key>Axis_01_MainProc</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_IsMast</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_MastId</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_Type</Key>
<Value>24#31</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_01_Dir</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_PosAct</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_PosTgt</Key>
<Value>56#63</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_FeedAct</Key>
<Value>64#71</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_FeedOver</Key>
<Value>72#79</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_AccelAct</Key>
<Value>80#87</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_AccTime</Key>
<Value>88#95</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_Battery</Key>
<Value>96#103</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_DistDone</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_01_InvDDone</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -348,55 +374,63 @@
<dataRefList>
<dataRef>
<Key>Axis_02_MainProc</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_IsMast</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_MastId</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_Type</Key>
<Value>24#31</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_02_Dir</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_PosAct</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_PosTgt</Key>
<Value>56#63</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_FeedAct</Key>
<Value>64#71</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_FeedOver</Key>
<Value>72#79</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_AccelAct</Key>
<Value>80#87</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_AccTime</Key>
<Value>88#95</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_Battery</Key>
<Value>96#103</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_DistDone</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_02_InvDDone</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -407,55 +441,63 @@
<dataRefList>
<dataRef>
<Key>Axis_03_MainProc</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_IsMast</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_MastId</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_Type</Key>
<Value>24#31</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_03_Dir</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_PosAct</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_PosTgt</Key>
<Value>56#63</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_FeedAct</Key>
<Value>64#71</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_FeedOver</Key>
<Value>72#79</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_AccelAct</Key>
<Value>80#87</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_AccTime</Key>
<Value>88#95</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_Battery</Key>
<Value>96#103</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_DistDone</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_03_InvDDone</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -466,55 +508,63 @@
<dataRefList>
<dataRef>
<Key>Axis_04_MainProc</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_IsMast</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_MastId</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_Type</Key>
<Value>24#31</Value>
<Value>ROTARY</Value>
</dataRef>
<dataRef>
<Key>Axis_04_Dir</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_PosAct</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_PosTgt</Key>
<Value>56#63</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_FeedAct</Key>
<Value>64#71</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_FeedOver</Key>
<Value>72#79</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_AccelAct</Key>
<Value>80#87</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_AccTime</Key>
<Value>88#95</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_Battery</Key>
<Value>96#103</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_DistDone</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_04_InvDDone</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -525,55 +575,63 @@
<dataRefList>
<dataRef>
<Key>Axis_05_MainProc</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_IsMast</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_MastId</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_Type</Key>
<Value>24#31</Value>
<Value>ROTARY</Value>
</dataRef>
<dataRef>
<Key>Axis_05_Dir</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_PosAct</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_PosTgt</Key>
<Value>56#63</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_FeedAct</Key>
<Value>64#71</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_FeedOver</Key>
<Value>72#79</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_AccelAct</Key>
<Value>80#87</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_AccTime</Key>
<Value>88#95</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_Battery</Key>
<Value>96#103</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_DistDone</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_05_InvDDone</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
@@ -584,55 +642,63 @@
<dataRefList>
<dataRef>
<Key>Axis_06_MainProc</Key>
<Value>0#7</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_IsMast</Key>
<Value>8#15</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_MastId</Key>
<Value>16#23</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_Type</Key>
<Value>24#31</Value>
<Value>LINEAR</Value>
</dataRef>
<dataRef>
<Key>Axis_06_Dir</Key>
<Value>32#39</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_Load</Key>
<Value>40#47</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_PosAct</Key>
<Value>48#55</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_PosTgt</Key>
<Value>56#63</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_FeedAct</Key>
<Value>64#71</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_FeedOver</Key>
<Value>72#79</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_AccelAct</Key>
<Value>80#87</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_AccTime</Key>
<Value>88#95</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_Battery</Key>
<Value>96#103</Value>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_DistDone</Key>
<Value>0</Value>
</dataRef>
<dataRef>
<Key>Axis_06_InvDDone</Key>
<Value>0</Value>
</dataRef>
</dataRefList>
</element>
File diff suppressed because it is too large Load Diff
@@ -0,0 +1,32 @@
# Commenti con cancelletto, struttura un variabile per riga, tipo chiave|valore (occhio che il separatore è configurato da .cofig come "testCharSep"); spazi e tabulazioni dovrei trimmarli in acquisizione (qui inseriti per comodità di lettura)
001|ACC_TIME |HOURS
002|ACC_TIME_WORK |HOURS
003|Path_01_PZ_TOT |COUNT
004|Axis_01_DistDone |METER
005|Axis_01_Invers |COUNT
006|Axis_02_DistDone |METER
007|Axis_02_Invers |COUNT
008|Axis_03_DistDone |METER
009|Axis_03_Invers |COUNT
010|Axis_04_DistDone |COUNT
011|Axis_04_Invers |COUNT
012|Axis_05_DistDone |COUNT
013|Axis_05_Invers |COUNT
014|Axis_06_DistDone |METER
015|Axis_06_Invers |COUNT
016|UnOp_01_AccTime |COUNT
017|VacPump_01_WrkTime |HOURS
018|VacPump_02_WrkTime |HOURS
019|VacAct_01_Count |COUNT
020|VacAct_02_Count |COUNT
021|Lubro_01_Num |COUNT
022|SlittaTastatore_Count |COUNT
023|SlittaMagazzino_01_Count |COUNT
024|ProtMagazzino_01_Count |COUNT
025|UnOp_01_NumCambiUT |COUNT
026|Axis_01_AccTime |COUNT
027|Axis_02_AccTime |COUNT
028|Axis_03_AccTime |COUNT
029|Axis_04_AccTime |COUNT
030|Axis_05_AccTime |COUNT
031|Axis_06_AccTime |COUNT
@@ -0,0 +1,9 @@
# Commenti con "#", elenco tipo codice:valore delle causali di HALT
001:[COD 001] - PRODUZIONE
002:[COD 002] - SETUP
003:[COD 003] - MACCHINA_DISPONIBILE
004:[COD 004] - MANUTENZIONE
005:[COD 005] - PULIZIA
006:[COD 006] - REGOLAZIONI
007:[COD 007] - PIPPO
Binary file not shown.

After

Width:  |  Height:  |  Size: 148 KiB

@@ -0,0 +1,7 @@
# Commenti con cancelletto, struttura un variabile per riga, tipo chiave|valore (occhio che il separatore è configurato da .cofig come "testCharSep"); spazi e tabulazioni dovrei trimmarli in acquisizione (qui inseriti per comodità di lettura)
001|PROTECTION_STATUS |BIT
002|VacPump_01_Status |BIT
003|VacPump_02_Status |BIT
004|Cooler_01_Status |BIT
005|Cooler_02_Status |BIT
006|UnOp_01_Status |BIT
@@ -0,0 +1,33 @@
# Commenti con "#", elenco tipo codice:valore delle label dei SUB_MODE di FANUC
0:DNC
1:Blk/Blk
2:BlkDel
3:OpStop
4:Teach
5:Prg Test
6:MLock
7:DryRun
8:Restart
9:x1
10:x10
11:x100
12:x1000
13:MANUAL_JOG
14:MANUAL_REF
15:MANUAL_JOGINC
16:MANUAL_HANDLE
17:
18:
19:
20:Asse selezionato 1
21:Asse selezionato 2
22:Asse selezionato 3
23:Asse selezionato 4
24:Asse selezionato 5
25:Asse selezionato 6
26:Asse selezionato 7
27:Asse selezionato 8
28:Asse selezionato 9
29:Asse selezionato 10
30:Asse selezionato 11
31:Asse selezionato 12
@@ -0,0 +1,4 @@
# Commenti con cancelletto, struttura un variabile per riga, tipo chiave|valore (occhio che il separatore è configurato da .config come "testCharSep")
OperatorId|CMS Operator 001
Path_01_CurrProg|WrkProgram_123
Path_01_PartId|P000123
+8 -3
View File
@@ -1,4 +1,7 @@
# servizio di disinstallazione del pacchetto MTConnect
# --------------------------------------------------------------
# Script disinstallazione MTConnect Agent
# S.E.L. e G.A.R. - Steamware 2016.12.09
# --------------------------------------------------------------
# recupero path da cui avviato lo script
$scriptPath = split-path -parent $MyInvocation.MyCommand.Definition
@@ -21,7 +24,8 @@ Write-Host "--------------------"
Write-Host "- ADAPTER AMMESSI"
Write-Host "--------------------"
Write-Host "1 - FANUC CMS"
#Write-Host "2 - ESA SCM"
Write-Host "2 - ESAGV (SCM)"
Write-Host "3 - SIEMENS (CMS)"
$adapter = read-host "Prego scegliere tipologia di ADAPTER da installare (default: 1 = Fanuc)"
if(!$adapter)
{
@@ -33,7 +37,8 @@ $AdpDir = ""
switch($adapter)
{
1 { $AdpDir = "FANUC" }
#2 { $AdpDir = "ESA" }
2 { $AdpDir = "ESA" }
3 { $AdpDir = "SIEMENS" }
default { $AdpDir = "FANUC" }
}