<serverConfig>
<ncConfig>
<ncVendor>S7NET</ncVendor> <!-- NO_NC/DEMO/FANUC/SIEMENS/OSAI/S7NET -->
<showNcHMI>false</showNcHMI>
<ncIpAddress>192.168.0.102</ncIpAddress>
<ncPort>102</ncPort>
<machineModel>Thermo 2020</machineModel>
<sharedPath>C:\CMS\Recipes\</sharedPath>
<sharedName>//PARTPRG:/</sharedName>
<installationDate>01/06/2020</installationDate>
<mgiOption>false</mgiOption>
<siemensKeyboardOption>false</siemensKeyboardOption>
<machineNumberHasLetters>false</machineNumberHasLetters>
</ncConfig>
<softwareProdConfig>
<enabled>false</enabled>
<path>C:\Program Files\Notepad++\notepad++.exe</path>
</softwareProdConfig>
<serverConfig>
<serverPort>9000</serverPort>
<serverAddress>*</serverAddress>
<language>en</language>
<enableDirectoryBrowsing>true</enableDirectoryBrowsing>
<databaseAddress>localhost</databaseAddress>
<autoOpenCmsClient>true</autoOpenCmsClient>
<textEditorPath>C:\Windows\System32\notepad.exe</textEditorPath>
<MTCFolderPath>C:\CMS\MTC\ADAPTER\</MTCFolderPath>
<MTCApplicationName>SCMA</MTCApplicationName>
<CMSConnectReady>false</CMSConnectReady>
<maxAlarmsRows>50000</maxAlarmsRows>
<alarmToDelete>5000</alarmToDelete>
</serverConfig>
<extSoftwares>
<software>
<longName>HC-DIAG2</longName>
<shortName>HD2</shortName>
<path>C:\Program Files (x86)\HC-DIAG2\HC-DIAG2.exe</path>
<arguments></arguments>
<inMainMenuBar>false</inMainMenuBar>
</software>
<software>
<longName>Calc</longName>
<shortName>NP</shortName>
<path>C:\Windows\System32\calc.exe</path>
<arguments></arguments>
<inMainMenuBar>false</inMainMenuBar>
</software>
</extSoftwares>
<additionalParameters>
<entry>
<key>warmerPlanSizeX</key>
<value>1500</value>
</entry>
<entry>
<key>warmerPlanSizeY</key>
<value>1200</value>
</entry>
<entry>
<key>resistSizeX</key>
<value>125</value>
</entry>
<entry>
<key>resistSizeY</key>
<value>60</value>
</entry>
<entry>
<key>warmerAutocompStartValue</key>
<value>50</value>
</entry>
<entry>
<key>warmerAutocompStep</key>
<value>5</value>
</entry>
<entry>
<key>LoaderXsize</key>
<value>1400</value>
</entry>
</additionalParameters>
<unitOfMeasures>
<unitOfMeasure id="0" value="" />
<unitOfMeasure id="1" value="mm" />
<unitOfMeasure id="2" value="Nm" />
<unitOfMeasure id="3" value="°C" />
<unitOfMeasure id="4" value="mm/s" />
<unitOfMeasure id="5" value="ms" />
<unitOfMeasure id="6" value="s" />
<unitOfMeasure id="7" value="%" />
</unitOfMeasures>
<sampling>
<thread name="alarms" value="200" />
<thread name="axis" value="200" />
<thread name="area" value="500" />
<thread name="confReq" value="2000" />
<thread name="expMan" value="30000" />
<thread name="functionEnab" value="300" />
<thread name="gauges" value="500" />
<thread name="m154" value="500" />
<thread name="mCommands" value="250" />
<thread name="powerOn" value="500" />
<thread name="prodCycle" value="1000" />
<thread name="prodInfo" value="1000" />
<thread name="prodPanel" value="1000" />
<thread name="modules" value="200" />
<thread name="recipe" value="400" />
<thread name="scada" value="1000" />
<thread name="statusCommand" value="250" />
<thread name="userSK" value="250" />
<thread name="warmers" value="1500" />
<thread name="watchdog" value="250" />
</sampling>