diff --git a/CMS_CORE_Library/S7Net/Nc_S7Net.cs b/CMS_CORE_Library/S7Net/Nc_S7Net.cs
index 8a5780a..2ae830f 100644
--- a/CMS_CORE_Library/S7Net/Nc_S7Net.cs
+++ b/CMS_CORE_Library/S7Net/Nc_S7Net.cs
@@ -3351,20 +3351,22 @@ namespace CMS_CORE_Library.S7Net
return NO_ERROR;
}
///
- /// Set current Warmers Channels ThermocamSetpoints (°C)
+ /// Set current Warmers Channels Temp REF Setpoints (1/10 °C)
///
///
///
public override CmsError PLC_WWarmerChTCamTempSet(Dictionary newData)
{
- // FIXME TODO serve nuova area termocamera
-#if false
+ // valori in 1/10 di °C
+ int dataScale = 10;
// memory area
- byte[] newMem = new byte[newData.Count];
- List currMem = new List();
+ short[] newMem = new short[newData.Count];
+ // leggo DB624 x Setpoint Temp richiesti
+ List currMem = new List();
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWShortList(R, 0, TCAM_TEMP_REQ_DATA.MemType, TCAM_TEMP_REQ_DATA.Address, TCAM_TEMP_REQ_DATA.SubAddress, TCAM_TEMP_REQ_DATA.Size, ref currMem);
- // read actual data on memory...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
if (libraryError.IsError())
return libraryError;
@@ -3373,15 +3375,16 @@ namespace CMS_CORE_Library.S7Net
// update only given data...
foreach (var item in newData)
{
- newMem[item.Key - 1] = (byte)item.Value;
+ // attenzione: effettua scalatura dati!
+ newMem[item.Key - 1] = (short)(dataScale * item.Value);
}
// return as list...
currMem = newMem.ToList();
+
// scrivo sul PLC array di byte...
- libraryError = MEM_RWByteList(W, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
+ libraryError = MEM_RWShortList(W, 0, TCAM_TEMP_REQ_DATA.MemType, TCAM_TEMP_REQ_DATA.Address, TCAM_TEMP_REQ_DATA.SubAddress, TCAM_TEMP_REQ_DATA.Size, ref currMem);
if (libraryError.IsError())
- return libraryError;
-#endif
+ return libraryError;
return NO_ERROR;
}
@@ -3392,14 +3395,16 @@ namespace CMS_CORE_Library.S7Net
///
public override CmsError PLC_WWarmerChTCamTempAct(Dictionary newData)
{
- // FIXME TODO serve nuova area termocamera
-#if false
+ // valori in 1/10 di °C
+ int dataScale = 10;
// memory area
- byte[] newMem = new byte[newData.Count];
- List currMem = new List();
+ short[] newMem = new short[newData.Count];
+ // leggo DB624 x Setpoint Temp richiesti
+ List currMem = new List();
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWShortList(R, 0, TCAM_TEMP_ACT_DATA.MemType, TCAM_TEMP_ACT_DATA.Address, TCAM_TEMP_ACT_DATA.SubAddress, TCAM_TEMP_ACT_DATA.Size, ref currMem);
- // read actual data on memory...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
if (libraryError.IsError())
return libraryError;
@@ -3408,15 +3413,16 @@ namespace CMS_CORE_Library.S7Net
// update only given data...
foreach (var item in newData)
{
- newMem[item.Key - 1] = (byte)item.Value;
+ // attenzione: effettua scalatura dati!
+ newMem[item.Key - 1] = (short)(dataScale * item.Value);
}
// return as list...
currMem = newMem.ToList();
+
// scrivo sul PLC array di byte...
- libraryError = MEM_RWByteList(W, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
+ libraryError = MEM_RWShortList(W, 0, TCAM_TEMP_ACT_DATA.MemType, TCAM_TEMP_ACT_DATA.Address, TCAM_TEMP_ACT_DATA.SubAddress, TCAM_TEMP_ACT_DATA.Size, ref currMem);
if (libraryError.IsError())
- return libraryError;
-#endif
+ return libraryError;
return NO_ERROR;
}