diff --git a/CMS_CORE_Library/CMS_CORE_Library.csproj b/CMS_CORE_Library/CMS_CORE_Library.csproj
index 4b249d3..507b6c5 100644
--- a/CMS_CORE_Library/CMS_CORE_Library.csproj
+++ b/CMS_CORE_Library/CMS_CORE_Library.csproj
@@ -152,6 +152,7 @@
+
diff --git a/CMS_CORE_Library/Models/DataStructures.cs b/CMS_CORE_Library/Models/DataStructures.cs
index 891298c..764032d 100644
--- a/CMS_CORE_Library/Models/DataStructures.cs
+++ b/CMS_CORE_Library/Models/DataStructures.cs
@@ -533,263 +533,5 @@ namespace CMS_CORE_Library.Models
#endregion Data structure models
- #region Thermo models
-
- ///
- /// Represents thermo gauge data
- ///
- public class GaugeModel
- {
- public uint TimeAdv { get; set; } = 0;
- public int Power { get; set; } = 0;
- public int Vacuum { get; set; } = 0;
- public int Air { get; set; } = 0;
-
- public override bool Equals(object obj)
- {
- // Object is not a GaugeModel instance
- if (!(obj is GaugeModel item))
- return false;
-
- if (TimeAdv != item.TimeAdv)
- return false;
-
- if (Power != item.Power)
- return false;
-
- if (Vacuum != item.Vacuum)
- return false;
-
- if (Air != item.Air)
- return false;
-
- return true;
- }
-
- public override int GetHashCode()
- {
- return base.GetHashCode();
- }
- }
-
- ///
- /// Recipe Parameters
- ///
- public class RecipeParam
- {
- public short Id { get; set; } = 0;
- public double SetpointHMI { get; set; } = 0;
- public double SetpointPLC { get; set; } = 0;
- public double ValMax { get; set; } = 0;
- public double ValMin { get; set; } = 0;
- public ushort UnitMeasure { get; set; } = 0;
- public bool Visible { get; set; } = false;
- public bool Enabled { get; set; } = false;
- public bool HasError { get; set; } = false;
- public double ValueAct { get; set; } = 0;
-
- public override bool Equals(object obj)
- {
- // Object is not a GaugeModel instance
- if (!(obj is RecipeParam item))
- return false;
-
- if (Id != item.Id)
- return false;
- if (SetpointHMI != item.SetpointHMI)
- return false;
- if (SetpointPLC != item.SetpointPLC)
- return false;
- if (ValMax != item.ValMax)
- return false;
- if (ValMin != item.ValMin)
- return false;
- if (UnitMeasure != item.UnitMeasure)
- return false;
- if (Visible != item.Visible)
- return false;
- if (Enabled != item.Enabled)
- return false;
- if (HasError != item.HasError)
- return false;
- if (ValueAct != item.ValueAct)
- return false;
-
- return true;
- }
- public override int GetHashCode()
- {
- return base.GetHashCode();
- }
- }
-
-
- public class ModuleBlock
- {
- public short Id { get; set; } = 0;
- public int ActualDelay { get; set; } = 0;
- public int ActualDuration { get; set; } = 0;
- public int EstimatedDelay { get; set; } = 0;
- public int EstimatedDuration { get; set; } = 0;
- public List PrecedingId { get; set; } = new List();
- public bool Visible { get; set; } = false;
- public bool Running { get; set; } = false;
- public bool HasError { get; set; } = false;
-
- public override bool Equals(object obj)
- {
- // Object is not a GaugeModel instance
- if (!(obj is ModuleBlock item))
- return false;
-
- if (Id != item.Id)
- return false;
- if (ActualDelay != item.ActualDelay)
- return false;
- if (ActualDuration != item.ActualDuration)
- return false;
- if (EstimatedDelay != item.EstimatedDelay)
- return false;
- if (EstimatedDuration != item.EstimatedDuration)
- return false;
- if (PrecedingId != item.PrecedingId)
- return false;
- if (Visible != item.Visible)
- return false;
- if (Running != item.Running)
- return false;
- if (HasError != item.HasError)
- return false;
-
- return true;
- }
- public override int GetHashCode()
- {
- return base.GetHashCode();
- }
- }
-
- public class WarmerChannel
- {
- public int IdChannel { get; set; } = 0;
- public double SetpointThermoCam { get; set; } = 0;
- public double SetpointPLC { get; set; } = 0;
- public byte ChStatus { get; set; } = 0;
- public byte PercAct { get; set; } = 0;
-
- public override bool Equals(object obj)
- {
- // Object is not a GaugeModel instance
- if (!(obj is WarmerChannel item))
- return false;
-
- if (IdChannel != item.IdChannel)
- return false;
- if (SetpointThermoCam != item.SetpointThermoCam)
- return false;
- if (SetpointPLC != item.SetpointPLC)
- return false;
- if (ChStatus != item.ChStatus)
- return false;
- if (PercAct != item.PercAct)
- return false;
-
- return true;
- }
- public override int GetHashCode()
- {
- return base.GetHashCode();
- }
- }
-
-
- public class ProdInfo
- {
- public short NumTarget { get; set; } = 0;
- public short NumDone { get; set; } = 0;
- public int TimeWarm { get; set; } = 0;
- public int TimeVent { get; set; } = 0;
- public int TimeVacuum { get; set; } = 0;
- public int TimeCycleGross { get; set; } = 0;
- public int TimeCycleNet { get; set; } = 0;
- public double MaterialTempEndWarm { get; set; } = 0;
- public double MaterialTempEndVent { get; set; } = 0;
- public double MoldTemp { get; set; } = 0;
- public double VacuumReadVal { get; set; } = 0;
- public double MouldEnergyOUT { get; set; } = 0;
- public double MouldEnergyIN { get; set; } = 0;
-
- public override bool Equals(object obj)
- {
- // Object is not a GaugeModel instance
- if (!(obj is ProdInfo item))
- return false;
-
- if (NumTarget != item.NumTarget)
- return false;
- if (NumDone != item.NumDone)
- return false;
- if (TimeWarm != item.TimeWarm)
- return false;
- if (TimeVent != item.TimeVent)
- return false;
- if (TimeVacuum != item.TimeVacuum)
- return false;
- if (TimeCycleGross != item.TimeCycleGross)
- return false;
- if (TimeCycleNet != item.TimeCycleNet)
- return false;
- if (MaterialTempEndWarm != item.MaterialTempEndWarm)
- return false;
- if (MaterialTempEndVent != item.MaterialTempEndVent)
- return false;
- if (MoldTemp != item.MoldTemp)
- return false;
- if (VacuumReadVal != item.VacuumReadVal)
- return false;
- if (MouldEnergyOUT != item.MouldEnergyOUT)
- return false;
- if (MouldEnergyIN != item.MouldEnergyIN)
- return false;
-
- return true;
- }
- public override int GetHashCode()
- {
- return base.GetHashCode();
- }
- }
-
- public class ProdCycle
- {
- public ushort Status { get; set; } = 0;
- public ushort MessageId { get; set; } = 0;
- public ushort Mode { get; set; } = 0;
- public uint TimeAdv { get; set; } = 0;
-
- public override bool Equals(object obj)
- {
- // Object is not a GaugeModel instance
- if (!(obj is ProdCycle item))
- return false;
-
- if (Status != item.Status)
- return false;
- if (MessageId != item.MessageId)
- return false;
- if (Mode != item.Mode)
- return false;
- if (TimeAdv != item.TimeAdv)
- return false;
-
- return true;
- }
- public override int GetHashCode()
- {
- return base.GetHashCode();
- }
- }
-
- #endregion
}
}
\ No newline at end of file
diff --git a/CMS_CORE_Library/Models/ThermoModels.cs b/CMS_CORE_Library/Models/ThermoModels.cs
new file mode 100644
index 0000000..52a9732
--- /dev/null
+++ b/CMS_CORE_Library/Models/ThermoModels.cs
@@ -0,0 +1,270 @@
+using System;
+using System.Collections.Generic;
+using System.Linq;
+using System.Text;
+using System.Threading.Tasks;
+
+namespace CMS_CORE_Library.Models
+{
+ public class ThermoModels
+ {
+ #region Thermo models
+
+ ///
+ /// Represents thermo gauge data
+ ///
+ public class GaugeModel
+ {
+ public uint TimeAdv { get; set; } = 0;
+ public int Power { get; set; } = 0;
+ public int Vacuum { get; set; } = 0;
+ public int Air { get; set; } = 0;
+
+ public override bool Equals(object obj)
+ {
+ // Object is not a GaugeModel instance
+ if (!(obj is GaugeModel item))
+ return false;
+
+ if (TimeAdv != item.TimeAdv)
+ return false;
+
+ if (Power != item.Power)
+ return false;
+
+ if (Vacuum != item.Vacuum)
+ return false;
+
+ if (Air != item.Air)
+ return false;
+
+ return true;
+ }
+
+ public override int GetHashCode()
+ {
+ return base.GetHashCode();
+ }
+ }
+
+ ///
+ /// Recipe Parameters
+ ///
+ public class RecipeParam
+ {
+ public short Id { get; set; } = 0;
+ public double SetpointHMI { get; set; } = 0;
+ public double SetpointPLC { get; set; } = 0;
+ public double ValMax { get; set; } = 0;
+ public double ValMin { get; set; } = 0;
+ public ushort UnitMeasure { get; set; } = 0;
+ public bool Visible { get; set; } = false;
+ public bool Enabled { get; set; } = false;
+ public bool HasError { get; set; } = false;
+ public double ValueAct { get; set; } = 0;
+
+ public override bool Equals(object obj)
+ {
+ // Object is not a GaugeModel instance
+ if (!(obj is RecipeParam item))
+ return false;
+
+ if (Id != item.Id)
+ return false;
+ if (SetpointHMI != item.SetpointHMI)
+ return false;
+ if (SetpointPLC != item.SetpointPLC)
+ return false;
+ if (ValMax != item.ValMax)
+ return false;
+ if (ValMin != item.ValMin)
+ return false;
+ if (UnitMeasure != item.UnitMeasure)
+ return false;
+ if (Visible != item.Visible)
+ return false;
+ if (Enabled != item.Enabled)
+ return false;
+ if (HasError != item.HasError)
+ return false;
+ if (ValueAct != item.ValueAct)
+ return false;
+
+ return true;
+ }
+ public override int GetHashCode()
+ {
+ return base.GetHashCode();
+ }
+ }
+
+
+ public class ModuleBlock
+ {
+ public short Id { get; set; } = 0;
+ public int ActualDelay { get; set; } = 0;
+ public int ActualDuration { get; set; } = 0;
+ public int EstimatedDelay { get; set; } = 0;
+ public int EstimatedDuration { get; set; } = 0;
+ public List PrecedingId { get; set; } = new List();
+ public bool Visible { get; set; } = false;
+ public bool Running { get; set; } = false;
+ public bool HasError { get; set; } = false;
+
+ public override bool Equals(object obj)
+ {
+ // Object is not a GaugeModel instance
+ if (!(obj is ModuleBlock item))
+ return false;
+
+ if (Id != item.Id)
+ return false;
+ if (ActualDelay != item.ActualDelay)
+ return false;
+ if (ActualDuration != item.ActualDuration)
+ return false;
+ if (EstimatedDelay != item.EstimatedDelay)
+ return false;
+ if (EstimatedDuration != item.EstimatedDuration)
+ return false;
+ if (PrecedingId != item.PrecedingId)
+ return false;
+ if (Visible != item.Visible)
+ return false;
+ if (Running != item.Running)
+ return false;
+ if (HasError != item.HasError)
+ return false;
+
+ return true;
+ }
+ public override int GetHashCode()
+ {
+ return base.GetHashCode();
+ }
+ }
+
+ public class WarmerChannel
+ {
+ public int IdChannel { get; set; } = 0;
+ public double SetpointThermoCam { get; set; } = 0;
+ public double SetpointPLC { get; set; } = 0;
+ public byte ChStatus { get; set; } = 0;
+ public byte PercAct { get; set; } = 0;
+
+ public override bool Equals(object obj)
+ {
+ // Object is not a GaugeModel instance
+ if (!(obj is WarmerChannel item))
+ return false;
+
+ if (IdChannel != item.IdChannel)
+ return false;
+ if (SetpointThermoCam != item.SetpointThermoCam)
+ return false;
+ if (SetpointPLC != item.SetpointPLC)
+ return false;
+ if (ChStatus != item.ChStatus)
+ return false;
+ if (PercAct != item.PercAct)
+ return false;
+
+ return true;
+ }
+ public override int GetHashCode()
+ {
+ return base.GetHashCode();
+ }
+ }
+
+
+ public class ProdInfo
+ {
+ public short NumTarget { get; set; } = 0;
+ public short NumDone { get; set; } = 0;
+ public int TimeWarm { get; set; } = 0;
+ public int TimeVent { get; set; } = 0;
+ public int TimeVacuum { get; set; } = 0;
+ public int TimeCycleGross { get; set; } = 0;
+ public int TimeCycleNet { get; set; } = 0;
+ public double MaterialTempEndWarm { get; set; } = 0;
+ public double MaterialTempEndVent { get; set; } = 0;
+ public double MoldTemp { get; set; } = 0;
+ public double VacuumReadVal { get; set; } = 0;
+ public double MouldEnergyOUT { get; set; } = 0;
+ public double MouldEnergyIN { get; set; } = 0;
+
+ public override bool Equals(object obj)
+ {
+ // Object is not a GaugeModel instance
+ if (!(obj is ProdInfo item))
+ return false;
+
+ if (NumTarget != item.NumTarget)
+ return false;
+ if (NumDone != item.NumDone)
+ return false;
+ if (TimeWarm != item.TimeWarm)
+ return false;
+ if (TimeVent != item.TimeVent)
+ return false;
+ if (TimeVacuum != item.TimeVacuum)
+ return false;
+ if (TimeCycleGross != item.TimeCycleGross)
+ return false;
+ if (TimeCycleNet != item.TimeCycleNet)
+ return false;
+ if (MaterialTempEndWarm != item.MaterialTempEndWarm)
+ return false;
+ if (MaterialTempEndVent != item.MaterialTempEndVent)
+ return false;
+ if (MoldTemp != item.MoldTemp)
+ return false;
+ if (VacuumReadVal != item.VacuumReadVal)
+ return false;
+ if (MouldEnergyOUT != item.MouldEnergyOUT)
+ return false;
+ if (MouldEnergyIN != item.MouldEnergyIN)
+ return false;
+
+ return true;
+ }
+ public override int GetHashCode()
+ {
+ return base.GetHashCode();
+ }
+ }
+
+ public class ProdCycle
+ {
+ public ushort Status { get; set; } = 0;
+ public ushort MessageId { get; set; } = 0;
+ public ushort Mode { get; set; } = 0;
+ public uint TimeAdv { get; set; } = 0;
+
+ public override bool Equals(object obj)
+ {
+ // Object is not a GaugeModel instance
+ if (!(obj is ProdCycle item))
+ return false;
+
+ if (Status != item.Status)
+ return false;
+ if (MessageId != item.MessageId)
+ return false;
+ if (Mode != item.Mode)
+ return false;
+ if (TimeAdv != item.TimeAdv)
+ return false;
+
+ return true;
+ }
+ public override int GetHashCode()
+ {
+ return base.GetHashCode();
+ }
+ }
+
+ #endregion
+ }
+}
diff --git a/CMS_CORE_Library/NcThermo.cs b/CMS_CORE_Library/NcThermo.cs
index d9518e0..ec8ff52 100644
--- a/CMS_CORE_Library/NcThermo.cs
+++ b/CMS_CORE_Library/NcThermo.cs
@@ -626,26 +626,26 @@ namespace CMS_CORE_Library
/// updates only RT parameters (false = update all)
///
///
- public abstract CmsError PLC_RRecipeParamList(bool onlyRT, ref Dictionary currParamList);
+ public abstract CmsError PLC_RRecipeParamList(bool onlyRT, ref Dictionary currParamList);
///
/// Write recipe updated parameter
///
///
///
- public abstract CmsError PLC_WRecipeParam(RecipeParam updtParam);
+ public abstract CmsError PLC_WRecipeParam(ThermoModels.RecipeParam updtParam);
///
/// Get current Modules Block list
///
/// updates only RT parameters (false = update all)
///
///
- public abstract CmsError PLC_RModulesBlockList(bool onlyRT, ref Dictionary currModulesBlockList);
+ public abstract CmsError PLC_RModulesBlockList(bool onlyRT, ref Dictionary currModulesBlockList);
///
/// Get current Warmers Channels list
///
///
///
- public abstract CmsError PLC_RWarmerChannelList(ref Dictionary currWarmerChannelList);
+ public abstract CmsError PLC_RWarmerChannelList(ref Dictionary currWarmerChannelList);
///
/// Read power gauge data
///
@@ -654,19 +654,19 @@ namespace CMS_CORE_Library
/// Returns an error when an internal or a library error occours
///
/// Reference to the value of the gauge data
- public abstract CmsError PLC_RGaugeData(ref GaugeModel gaugeData);
+ public abstract CmsError PLC_RGaugeData(ref ThermoModels.GaugeModel gaugeData);
///
/// Get current Production Info data
///
///
///
- public abstract CmsError PLC_RProdInfo(ref ProdInfo currProdInfo);
+ public abstract CmsError PLC_RProdInfo(ref ThermoModels.ProdInfo currProdInfo);
///
/// Get current Production Cycle data
///
///
///
- public abstract CmsError PLC_RProdCycle(ref ProdCycle currProdCycle);
+ public abstract CmsError PLC_RProdCycle(ref ThermoModels.ProdCycle currProdCycle);
#endregion THERMO high level data
diff --git a/CMS_CORE_Library/S7Net/Nc_S7Net.cs b/CMS_CORE_Library/S7Net/Nc_S7Net.cs
index daeb6c8..22591f2 100644
--- a/CMS_CORE_Library/S7Net/Nc_S7Net.cs
+++ b/CMS_CORE_Library/S7Net/Nc_S7Net.cs
@@ -58,11 +58,11 @@ namespace CMS_CORE_Library.S7Net
// Dizionario parametri specifici per THERMO
- private static Dictionary ThermoParamList;
- private static Dictionary ThermoModuleList;
- private static Dictionary ThermoWarmChannels;
- private static ProdInfo ThermoProdInfo;
- private static ProdCycle ThermoProdCycle;
+ private static Dictionary ThermoParamList;
+ private static Dictionary ThermoModuleList;
+ private static Dictionary ThermoWarmChannels;
+ private static ThermoModels.ProdInfo ThermoProdInfo;
+ private static ThermoModels.ProdCycle ThermoProdCycle;
// connessione S7
private CpuType tipoCpu = CpuType.S71500;
@@ -133,11 +133,11 @@ namespace CMS_CORE_Library.S7Net
// mesasggi generici PLC
PlcMessages = new Dictionary();
// Init dati specifici Themo
- ThermoParamList = new Dictionary();
- ThermoModuleList = new Dictionary();
- ThermoWarmChannels = new Dictionary();
- ThermoProdCycle = new ProdCycle();
- ThermoProdInfo = new ProdInfo();
+ ThermoParamList = new Dictionary();
+ ThermoModuleList = new Dictionary();
+ ThermoWarmChannels = new Dictionary();
+ ThermoProdCycle = new ThermoModels.ProdCycle();
+ ThermoProdInfo = new ThermoModels.ProdInfo();
}
///
/// Connessione al PLC
@@ -1811,7 +1811,7 @@ namespace CMS_CORE_Library.S7Net
/// updates only RT parameters (false = update all)
///
///
- public override CmsError PLC_RRecipeParamList(bool onlyRT, ref Dictionary currParamList)
+ public override CmsError PLC_RRecipeParamList(bool onlyRT, ref Dictionary currParamList)
{
// se richiesto NON SOLO RT faccio refresh anche dati "lenti"
if (!onlyRT)
@@ -1830,7 +1830,7 @@ namespace CMS_CORE_Library.S7Net
///
///
///
- public override CmsError PLC_WRecipeParam(RecipeParam updtParam)
+ public override CmsError PLC_WRecipeParam(ThermoModels.RecipeParam updtParam)
{
// init variabili accessorie
List currMem = new List();
@@ -1859,7 +1859,7 @@ namespace CMS_CORE_Library.S7Net
/// updates only RT parameters (false = update all)
///
///
- public override CmsError PLC_RModulesBlockList(bool onlyRT, ref Dictionary currModulesBlockList)
+ public override CmsError PLC_RModulesBlockList(bool onlyRT, ref Dictionary currModulesBlockList)
{
// se richiesto NON SOLO RT faccio refresh anche dati "lenti"
if (!onlyRT)
@@ -1878,7 +1878,7 @@ namespace CMS_CORE_Library.S7Net
///
///
///
- public override CmsError PLC_RWarmerChannelList(ref Dictionary currWarmerChannelList)
+ public override CmsError PLC_RWarmerChannelList(ref Dictionary currWarmerChannelList)
{
// refresh stato canale
refreshRiscStatus();
@@ -1900,7 +1900,7 @@ namespace CMS_CORE_Library.S7Net
///
///
///
- public override CmsError PLC_RGaugeData(ref GaugeModel gaugeData)
+ public override CmsError PLC_RGaugeData(ref ThermoModels.GaugeModel gaugeData)
{
List Values = new List();
CmsError cmsError = MEM_RWIntegerList(R, 1, MACHINE_GAUGE_DATA.MemType, MACHINE_GAUGE_DATA.Address, MACHINE_GAUGE_DATA.SubAddress, MACHINE_GAUGE_DATA.Size / 4, ref Values);
@@ -1908,7 +1908,7 @@ namespace CMS_CORE_Library.S7Net
if (cmsError.IsError())
return cmsError;
- gaugeData = new GaugeModel()
+ gaugeData = new ThermoModels.GaugeModel()
{
TimeAdv = Convert.ToUInt32(Values[0]),
Power = Values[1],
@@ -1923,7 +1923,7 @@ namespace CMS_CORE_Library.S7Net
///
///
///
- public override CmsError PLC_RProdInfo(ref ProdInfo currProdInfo)
+ public override CmsError PLC_RProdInfo(ref ThermoModels.ProdInfo currProdInfo)
{
List currMem = new List();
CmsError cmsError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
@@ -1931,7 +1931,7 @@ namespace CMS_CORE_Library.S7Net
if (cmsError.IsError())
return cmsError;
// converto!
- currProdInfo = new ProdInfo()
+ currProdInfo = new ThermoModels.ProdInfo()
{
NumTarget = S7.Net.Types.Int.FromByteArray(currMem.Skip(0).Take(2).ToArray()),
NumDone = S7.Net.Types.Int.FromByteArray(currMem.Skip(2).Take(2).ToArray()),
@@ -1956,7 +1956,7 @@ namespace CMS_CORE_Library.S7Net
///
///
///
- public override CmsError PLC_RProdCycle(ref ProdCycle currProdCycle)
+ public override CmsError PLC_RProdCycle(ref ThermoModels.ProdCycle currProdCycle)
{
List currMem = new List();
CmsError cmsError = MEM_RWByteList(R, 0, PROCESS_PROD_CYCLE.MemType, PROCESS_PROD_CYCLE.Address, PROCESS_PROD_CYCLE.SubAddress, 0, PROCESS_PROD_CYCLE.Size, ref currMem);
@@ -1964,7 +1964,7 @@ namespace CMS_CORE_Library.S7Net
if (cmsError.IsError())
return cmsError;
// converto!
- currProdCycle = new ProdCycle()
+ currProdCycle = new ThermoModels.ProdCycle()
{
Status = S7.Net.Types.Word.FromByteArray(currMem.Skip(0).Take(2).ToArray()),
MessageId = S7.Net.Types.Word.FromByteArray(currMem.Skip(2).Take(2).ToArray()),
@@ -2009,7 +2009,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoParamList.Add(currParam.Id, new RecipeParam() { Id = currParam.Id, Enabled = currParam.Enabled, HasError = currParam.HasError, Visible = currParam.Visible, ValueAct = currParam.ValueAct });
+ ThermoParamList.Add(currParam.Id, new ThermoModels.RecipeParam() { Id = currParam.Id, Enabled = currParam.Enabled, HasError = currParam.HasError, Visible = currParam.Visible, ValueAct = currParam.ValueAct });
}
}
}
@@ -2049,7 +2049,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoParamList.Add(currParam.Id, new RecipeParam() { Id = currParam.Id, SetpointHMI = currParam.SetpointHMI, SetpointPLC = currParam.SetpointPLC, ValMax = currParam.ValMax, ValMin = currParam.ValMin, UnitMeasure = currParam.UnitMeasure });
+ ThermoParamList.Add(currParam.Id, new ThermoModels.RecipeParam() { Id = currParam.Id, SetpointHMI = currParam.SetpointHMI, SetpointPLC = currParam.SetpointPLC, ValMax = currParam.ValMax, ValMin = currParam.ValMin, UnitMeasure = currParam.UnitMeasure });
}
}
}
@@ -2174,7 +2174,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoModuleList.Add(currModBlock.Id, new ModuleBlock()
+ ThermoModuleList.Add(currModBlock.Id, new ThermoModels.ModuleBlock()
{
Id = currModBlock.Id,
ActualDuration = currModBlock.ActualDuration,
@@ -2225,7 +2225,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoModuleList.Add(currModBlock.Id, new ModuleBlock()
+ ThermoModuleList.Add(currModBlock.Id, new ThermoModels.ModuleBlock()
{
Id = currModBlock.Id,
EstimatedDelay = currModBlock.EstimDelay,
@@ -2360,7 +2360,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoWarmChannels.Add(i + 1, new WarmerChannel()
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
SetpointPLC = currVal
@@ -2394,7 +2394,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoWarmChannels.Add(i + 1, new WarmerChannel()
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
PercAct = memArray[i]
@@ -2428,7 +2428,7 @@ namespace CMS_CORE_Library.S7Net
}
else
{
- ThermoWarmChannels.Add(i + 1, new WarmerChannel()
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
{
IdChannel = i + 1,
ChStatus = memArray[i]