diff --git a/CMS_CORE_Library/NcThermo.cs b/CMS_CORE_Library/NcThermo.cs
index 3480140..9588a6e 100644
--- a/CMS_CORE_Library/NcThermo.cs
+++ b/CMS_CORE_Library/NcThermo.cs
@@ -625,6 +625,11 @@ namespace CMS_CORE_Library
///
///
public abstract CmsError PLC_WAckPzProdEnd();
+ ///
+ /// Process setpointHMI invalidated with ack
+ ///
+ ///
+ public abstract CmsError PLC_WAckSetpointInvalidated();
///
/// Get current Axis RT data
diff --git a/CMS_CORE_Library/S7Net/Nc_S7Net.cs b/CMS_CORE_Library/S7Net/Nc_S7Net.cs
index 493cfde..ee656f8 100644
--- a/CMS_CORE_Library/S7Net/Nc_S7Net.cs
+++ b/CMS_CORE_Library/S7Net/Nc_S7Net.cs
@@ -18,279 +18,279 @@ using static CMS_CORE_Library.Utils.Nc_Utils;
namespace CMS_CORE_Library.S7Net
{
- public class Nc_S7Net : NcThermo
- {
-
- #region costanti ed oggetti
- // Global Constants
-
- private const string NcNotFound = "Missing response";
- private const string NcNotFound2 = "networking error";
- private const string NcNotFound3 = "Nc not Connected";
-
- // Global Variables
- private static DateTime Last_Static_Read;
-
- private byte S7Language;
- private static string Cnc_name;
- private static string Cnc_SftVersion;
- private static string Cnc_SeriesNum;
- private static string Cms_MachNumber;
- private static string PlcFirmware_SerialNum;
- private static uint ConfChannelNo;
- private static string UnitOfMeasure;
-
- // Alarms data
- private static Dictionary PlcMessages = new Dictionary();
- private const string THERMO_DICT_PATH = @"Dict\";
-
- private static ushort SelectedProcess = 1;
-
- private bool EnableAlarms;
- private bool EnableHeaters;
- private bool EnableModules;
- private bool EnableParameters;
- private bool EnableProd;
-
- private bool EnableAxes;
-
-
- // Dizionario parametri specifici per THERMO
- private static Dictionary ThermoParamList = new Dictionary();
- private static Dictionary ThermoModuleList = new Dictionary();
- private static Dictionary ThermoWarmChannels = new Dictionary();
- private static ThermoModels.ProdInfoModel ThermoProdInfo = new ThermoModels.ProdInfoModel();
- private static ThermoModels.ProdCycleModel ThermoProdCycle = new ThermoModels.ProdCycleModel();
-
- // connessione S7
- private CpuType tipoCpu = CpuType.S71500;
- private short rack = 0;
- private short slot = 1;
-
- ///
- /// Oggetto PLC da ri-utilizzare...
- ///
- protected Plc currPLC;
- ///
- /// Lock per connessione PLC
- ///
- private readonly static object connectLock = new object();
-
- #endregion
-
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
-
- #region Constructor & global methods
-
- ///
- ///Instantiate The NC-S7Net Class
- ///
- /// Remote Ip-Address of the Nc
- /// Remote Port of the Nc
- ///Send/Recieve timeout connection [mS]
- public Nc_S7Net(string IpAddress, ushort RemotePort, ushort ConnectionTimeOut)
+ public class Nc_S7Net : NcThermo
{
- initObjects(IpAddress, RemotePort, false, true, true, true, true, true);
- }
- ///
- /// Instantiate The NC-Siemens Class
- ///
- /// Remote Ip-Address of the Nc
- /// Remote Port of the Nc
- /// Send/Recieve timeout connection [mS]
- /// Enable Axes Svc
- /// Enable Alarms Svc
- /// Enable Heaters Svc
- /// Enable Modules Svc
- /// Enable Parameters Svc
- /// Enable Prod Svc
- public Nc_S7Net(string IpAddress, ushort RemotePort, ushort ConnectionTimeOut, bool EnableAxes, bool EnableAlarms, bool EnableHeaters, bool EnableModules, bool EnableParameters, bool EnableProd)
- {
- initObjects(IpAddress, RemotePort, EnableAxes, EnableAlarms, EnableHeaters, EnableModules, EnableParameters, EnableProd);
- }
- ///
- /// /Inizializzazione effettiva parametri classe
- ///
- ///
- ///
- ///
- ///
- ///
- ///
- ///
- ///
- private void initObjects(string IpAddress, ushort RemotePort, bool EnableAxes, bool EnableAlarms, bool EnableHeaters, bool EnableModules, bool EnableParameters, bool EnableProd)
- {
- // Setup options
- this.EnableAlarms = EnableAlarms;
- this.EnableAxes = EnableAxes;
- this.EnableHeaters = EnableHeaters;
- this.EnableModules = EnableModules;
- this.EnableParameters = EnableParameters;
- this.EnableProd = EnableProd;
- // Setup parametri
- Ip = IpAddress;
- Port = RemotePort;
- // mesasggi generici PLC
- PlcMessages = new Dictionary();
- // Init dati specifici Thermo
+ #region costanti ed oggetti
+ // Global Constants
- }
- ///
- /// Connessione al PLC
- ///
- ///
- public override CmsError NC_Connect()
- {
- lock (connectLock)
- {
- // Try to get information
- try
+ private const string NcNotFound = "Missing response";
+ private const string NcNotFound2 = "networking error";
+ private const string NcNotFound3 = "Nc not Connected";
+
+ // Global Variables
+ private static DateTime Last_Static_Read;
+
+ private byte S7Language;
+ private static string Cnc_name;
+ private static string Cnc_SftVersion;
+ private static string Cnc_SeriesNum;
+ private static string Cms_MachNumber;
+ private static string PlcFirmware_SerialNum;
+ private static uint ConfChannelNo;
+ private static string UnitOfMeasure;
+
+ // Alarms data
+ private static Dictionary PlcMessages = new Dictionary();
+ private const string THERMO_DICT_PATH = @"Dict\";
+
+ private static ushort SelectedProcess = 1;
+
+ private bool EnableAlarms;
+ private bool EnableHeaters;
+ private bool EnableModules;
+ private bool EnableParameters;
+ private bool EnableProd;
+
+ private bool EnableAxes;
+
+
+ // Dizionario parametri specifici per THERMO
+ private static Dictionary ThermoParamList = new Dictionary();
+ private static Dictionary ThermoModuleList = new Dictionary();
+ private static Dictionary ThermoWarmChannels = new Dictionary();
+ private static ThermoModels.ProdInfoModel ThermoProdInfo = new ThermoModels.ProdInfoModel();
+ private static ThermoModels.ProdCycleModel ThermoProdCycle = new ThermoModels.ProdCycleModel();
+
+ // connessione S7
+ private CpuType tipoCpu = CpuType.S71500;
+ private short rack = 0;
+ private short slot = 1;
+
+ ///
+ /// Oggetto PLC da ri-utilizzare...
+ ///
+ protected Plc currPLC;
+ ///
+ /// Lock per connessione PLC
+ ///
+ private readonly static object connectLock = new object();
+
+ #endregion
+
+ ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
+
+ #region Constructor & global methods
+
+ ///
+ ///Instantiate The NC-S7Net Class
+ ///
+ /// Remote Ip-Address of the Nc
+ /// Remote Port of the Nc
+ ///Send/Recieve timeout connection [mS]
+ public Nc_S7Net(string IpAddress, ushort RemotePort, ushort ConnectionTimeOut)
{
- // Check if Siemens Environment is started
- CmsError libraryError = CheckS7Ping();
- if (libraryError.IsError())
- return libraryError;
+ initObjects(IpAddress, RemotePort, false, true, true, true, true, true);
+ }
+ ///
+ /// Instantiate The NC-Siemens Class
+ ///
+ /// Remote Ip-Address of the Nc
+ /// Remote Port of the Nc
+ /// Send/Recieve timeout connection [mS]
+ /// Enable Axes Svc
+ /// Enable Alarms Svc
+ /// Enable Heaters Svc
+ /// Enable Modules Svc
+ /// Enable Parameters Svc
+ /// Enable Prod Svc
+ public Nc_S7Net(string IpAddress, ushort RemotePort, ushort ConnectionTimeOut, bool EnableAxes, bool EnableAlarms, bool EnableHeaters, bool EnableModules, bool EnableParameters, bool EnableProd)
+ {
+ initObjects(IpAddress, RemotePort, EnableAxes, EnableAlarms, EnableHeaters, EnableModules, EnableParameters, EnableProd);
+ }
+ ///
+ /// /Inizializzazione effettiva parametri classe
+ ///
+ ///
+ ///
+ ///
+ ///
+ ///
+ ///
+ ///
+ ///
+ private void initObjects(string IpAddress, ushort RemotePort, bool EnableAxes, bool EnableAlarms, bool EnableHeaters, bool EnableModules, bool EnableParameters, bool EnableProd)
+ {
+ // Setup options
+ this.EnableAlarms = EnableAlarms;
+ this.EnableAxes = EnableAxes;
+ this.EnableHeaters = EnableHeaters;
+ this.EnableModules = EnableModules;
+ this.EnableParameters = EnableParameters;
+ this.EnableProd = EnableProd;
- // Check connection
- currPLC = new Plc(tipoCpu, this.Ip, this.rack, this.slot);
- currPLC.Open();
- if (currPLC.IsConnected)
- Connected = true;
+ // Setup parametri
+ Ip = IpAddress;
+ Port = RemotePort;
+ // mesasggi generici PLC
+ PlcMessages = new Dictionary();
+ // Init dati specifici Thermo
- // FARE TODO FIXME
- // Setup the alarms (with DB bitmap) --> PlcMessages
+ }
+ ///
+ /// Connessione al PLC
+ ///
+ ///
+ public override CmsError NC_Connect()
+ {
+ lock (connectLock)
+ {
+ // Try to get information
+ try
+ {
+ // Check if Siemens Environment is started
+ CmsError libraryError = CheckS7Ping();
+ if (libraryError.IsError())
+ return libraryError;
- if (this.EnableAlarms)
- {
- // PlcMessages
+ // Check connection
+ currPLC = new Plc(tipoCpu, this.Ip, this.rack, this.slot);
+ currPLC.Open();
+ if (currPLC.IsConnected)
+ Connected = true;
+
+ // FARE TODO FIXME
+ // Setup the alarms (with DB bitmap) --> PlcMessages
+
+ if (this.EnableAlarms)
+ {
+ // PlcMessages
#if false
SiemensAlarms = new Alarm[] { };
SiemensAlmSvc = new AlarmSvc(ConvertToSTEPLanguage(SiemensLanguage).ThreeLetterISOLanguageName);
SiemensAlmSvc.Subscribe(AlarmsChanged);
Infrastructure.SubscribeLanguageChanged(NcLanguageChanged);
#endif
- }
+ }
+ }
+ catch (Exception ex)
+ {
+ return ManageException(ex);
+ }
+ }
+ return NO_ERROR;
}
- catch (Exception ex)
+ ///
+ /// Disconnect Method
+ ///
+ ///
+ public override CmsError NC_Disconnect()
{
- return ManageException(ex);
+ // Set Connected to FALSE and close the sessions
+ Connected = false;
+ if (currPLC != null)
+ {
+ try
+ {
+ currPLC.Close();
+ }
+ catch
+ { }
+ }
+ return NO_ERROR;
}
- }
- return NO_ERROR;
- }
- ///
- /// Disconnect Method
- ///
- ///
- public override CmsError NC_Disconnect()
- {
- // Set Connected to FALSE and close the sessions
- Connected = false;
- if (currPLC != null)
- {
- try
+ ///
+ /// Compilazione dizionario allarmi x lingua
+ ///
+ ///
+ ///
+ ///
+ public override CmsError NC_GetTranslatedPlcMessages(string language, ref Dictionary messages)
{
- currPLC.Close();
+ string filePath;
+ try
+ {
+ PlcMessages = new Dictionary();
+ CultureInfo cultureInfo = CultureInfo.CreateSpecificCulture(language);
+ string langName = "";
+ if (cultureInfo.IsNeutralCulture)
+ langName = cultureInfo.EnglishName;
+ else
+ langName = cultureInfo.Parent.EnglishName;
+
+ //Setup the Path
+ filePath = THERMO_DICT_PATH + @"Messaggi_" + langName + @".txt";
+
+ //Read From Files
+ messages = File.ReadAllLines(filePath, Encoding.Default)
+ .Select(line => line.Split(','))
+ .Where(line => line.Count() == 2)
+ .ToDictionary(line => Convert.ToInt32(line[0]), line => line[1].Trim());
+
+ }
+ catch (Exception ex)
+ {
+ return ManageException(ex);
+ }
+ return NO_ERROR;
}
- catch
- { }
- }
- return NO_ERROR;
- }
- ///
- /// Compilazione dizionario allarmi x lingua
- ///
- ///
- ///
- ///
- public override CmsError NC_GetTranslatedPlcMessages(string language, ref Dictionary messages)
- {
- string filePath;
- try
- {
- PlcMessages = new Dictionary();
- CultureInfo cultureInfo = CultureInfo.CreateSpecificCulture(language);
- string langName = "";
- if (cultureInfo.IsNeutralCulture)
- langName = cultureInfo.EnglishName;
- else
- langName = cultureInfo.Parent.EnglishName;
+ ///
+ /// Compilazione dizionario traduzioni THermo
+ ///
+ ///
+ ///
+ ///
+ public override CmsError NC_GetTranslatedThermoLabels(string language, ref Dictionary messages)
+ {
+ string filePath;
+ Dictionary dict01 = new Dictionary();
+ Dictionary dict02 = new Dictionary();
+ try
+ {
+ CultureInfo cultureInfo = CultureInfo.CreateSpecificCulture(language);
+ string langName = "";
+ if (cultureInfo.IsNeutralCulture)
+ langName = cultureInfo.EnglishName;
+ else
+ langName = cultureInfo.Parent.EnglishName;
- //Setup the Path
- filePath = THERMO_DICT_PATH + @"Messaggi_" + langName + @".txt";
+ // Setup the Path for enums
+ filePath = THERMO_DICT_PATH + @"Enums_" + langName + @".txt";
- //Read From Files
- messages = File.ReadAllLines(filePath, Encoding.Default)
- .Select(line => line.Split(','))
- .Where(line => line.Count() == 2)
- .ToDictionary(line => Convert.ToInt32(line[0]), line => line[1].Trim());
+ // Read From File...
+ dict01 = File.ReadAllLines(filePath, Encoding.Default)
+ .Select(line => line.Split(','))
+ .Where(line => line.Count() == 2)
+ .ToDictionary(line => line[0].Trim(), line => line[1].Trim());
- }
- catch (Exception ex)
- {
- return ManageException(ex);
- }
- return NO_ERROR;
- }
- ///
- /// Compilazione dizionario traduzioni THermo
- ///
- ///
- ///
- ///
- public override CmsError NC_GetTranslatedThermoLabels(string language, ref Dictionary messages)
- {
- string filePath;
- Dictionary dict01 = new Dictionary();
- Dictionary dict02 = new Dictionary();
- try
- {
- CultureInfo cultureInfo = CultureInfo.CreateSpecificCulture(language);
- string langName = "";
- if (cultureInfo.IsNeutralCulture)
- langName = cultureInfo.EnglishName;
- else
- langName = cultureInfo.Parent.EnglishName;
+ // Setup the Path for labels
+ filePath = THERMO_DICT_PATH + @"Labels_" + langName + @".txt";
- // Setup the Path for enums
- filePath = THERMO_DICT_PATH + @"Enums_" + langName + @".txt";
+ // Read From File...
+ dict02 = File.ReadAllLines(filePath, Encoding.Default)
+ .Select(line => line.Split(','))
+ .Where(line => line.Count() == 2)
+ .ToDictionary(line => line[0].Trim(), line => line[1].Trim());
- // Read From File...
- dict01 = File.ReadAllLines(filePath, Encoding.Default)
- .Select(line => line.Split(','))
- .Where(line => line.Count() == 2)
- .ToDictionary(line => line[0].Trim(), line => line[1].Trim());
+ // combine 2 dictionary...
+ messages = dict01.Union(dict02).ToDictionary(d => d.Key, d => d.Value);
- // Setup the Path for labels
- filePath = THERMO_DICT_PATH + @"Labels_" + langName + @".txt";
-
- // Read From File...
- dict02 = File.ReadAllLines(filePath, Encoding.Default)
- .Select(line => line.Split(','))
- .Where(line => line.Count() == 2)
- .ToDictionary(line => line[0].Trim(), line => line[1].Trim());
-
- // combine 2 dictionary...
- messages = dict01.Union(dict02).ToDictionary(d => d.Key, d => d.Value);
-
- }
- catch (Exception ex)
- {
- return ManageException(ex);
- }
- return NO_ERROR;
- }
- ///
- /// Elenco lingue disponibili
- ///
- ///
- ///
- public override CmsError NC_GetAvailableLanguages(ref ICollection languages)
- {
- // FIXME TODO
+ }
+ catch (Exception ex)
+ {
+ return ManageException(ex);
+ }
+ return NO_ERROR;
+ }
+ ///
+ /// Elenco lingue disponibili
+ ///
+ ///
+ ///
+ public override CmsError NC_GetAvailableLanguages(ref ICollection languages)
+ {
+ // FIXME TODO
#if false
try
{
@@ -321,1316 +321,1316 @@ namespace CMS_CORE_Library.S7Net
}
#endif
- var lang = GetCultureFromThreeLetter("eng");
- if (lang != null)
- languages.Add(lang);
- lang = GetCultureFromThreeLetter("ita");
- if (lang != null)
- languages.Add(lang);
+ var lang = GetCultureFromThreeLetter("eng");
+ if (lang != null)
+ languages.Add(lang);
+ lang = GetCultureFromThreeLetter("ita");
+ if (lang != null)
+ languages.Add(lang);
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- #endregion Contructor & global methods
+ #endregion Contructor & global methods
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
+ ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
- #region High level methods
+ #region High level methods
- ///
- /// Get the processes-count configurated
- ///
- ///
- ///
- public override CmsError NC_RProcessesNum(ref ushort ProcNumber)
- {
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- ProcNumber = (ushort)ConfChannelNo;
-
- return NO_ERROR;
- }
-
- ///
- /// Get the NC model Name
- ///
- ///
- ///
- public override CmsError NC_RModelName(ref string ModelName)
- {
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- ModelName = Cnc_name;
-
- return NO_ERROR;
- }
-
- ///
- /// Get the NC Software Version
- ///
- ///
- ///
- public override CmsError NC_RSoftwareVersion(ref string SWV)
- {
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- SWV = Cnc_SftVersion;
-
- return NO_ERROR;
- }
-
- ///
- /// Get the NC Language
- ///
- ///
- ///
- public override CmsError NC_RLanguage(ref CultureInfo Language)
- {
- // Read static data
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- Language = ConvertToSTEPLanguage(S7Language);
-
- return NO_ERROR;
- }
-
- ///
- /// Set the NC Language
- ///
- ///
- ///
- public override CmsError NC_WLanguage(CultureInfo Language)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- ///
- /// Get the NC Serial number
- ///
- ///
- ///
- public override CmsError NC_RSerialNumber(ref string serialNumber)
- {
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- serialNumber = Cnc_SeriesNum;
-
- return NO_ERROR;
- }
-
- ///
- /// Get CMS Machine number
- ///
- ///
- ///
- ///
- public override CmsError NC_RMachineNumber(bool hasLetters, ref string MachNumber)
- {
- if (!hasLetters)
- {
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- MachNumber = Cms_MachNumber;
- }
- else
- {
- // New method to read machine number
- List lists = new List();
- CmsError libraryError = MEM_RWByteList(R, 0, NEW_MATR_MACC.MemType, NEW_MATR_MACC.Address, NEW_MATR_MACC.SubAddress, 0, 4, ref lists);
- if (libraryError.IsError())
- return libraryError;
-
- lists.Reverse();
-
- MachNumber = Encoding.ASCII.GetString(lists.ToArray().Reverse().ToArray());
- }
-
- return NO_ERROR;
- }
-
- ///
- /// Get the Date-Time of the NC
- ///
- ///
- ///
- public override CmsError NC_RDateTime(ref DateTime ActualTime)
- {
- ActualTime = DateTime.Now;
- return NO_ERROR;
- }
-
- ///
- /// Check if the NC is in running state
- ///
- ///
- ///
- public override CmsError NC_RIsRunning(ref bool running)
- {
- ushort nProcess = 0;
- // Get the number of processes
- CmsError libraryError = NC_RProcessesNum(ref nProcess);
- if (libraryError.IsError())
- return libraryError;
-
- ushort i = 1;
- running = false;
- do
- {
- PROC_STATUS procStatus = PROC_STATUS.IDLE;
-
- // Read process status
- libraryError = PROC_RStatus(i, ref procStatus);
- if (libraryError.IsError())
- return libraryError;
-
- if (procStatus == PROC_STATUS.RUN)
- running = true;
- i++;
- } while (!running || i <= nProcess);
-
- return NO_ERROR;
- }
-
- ///
- /// Get NC unit of measure
- ///
- ///
- ///
- public override CmsError NC_RUnitOfMeasure(ref string unitOfMeasure)
- {
- CmsError libraryError = ReadStaticNCData();
- if (libraryError.IsError())
- return libraryError;
-
- unitOfMeasure = UnitOfMeasure;
-
- return NO_ERROR;
- }
-
- ///
- /// Get the Nc Active Alarms
- ///
- ///
- ///
- public override CmsError NC_RActiveAlarms(ref List alarms)
- {
- return NO_ERROR;
- }
-
- ///
- /// Set the Nc Active Page of the NC
- ///
- ///
- ///
- public override CmsError NC_SetScreenVisible(SCREEN_PAGE screen)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError NC_WMDICommand(int processId, string mdiString)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- #endregion High level methods
-
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
-
- #region PLC High-level data
-
- public override CmsError PLC_RWManageWatchdog()
- {
- // watchdog in memoria WORD --> true x endianness!
- bool plcWatchdog = false;
- CmsError libraryError = MEM_RWBoolean(R, true, 0, NC_WATCHDOG.MemType, NC_WATCHDOG.Address, NC_WATCHDOG.SubAddress, 0, ref plcWatchdog);
- if (libraryError.IsError())
- return libraryError;
-
- if (plcWatchdog)
- return PLC_NOT_RUNNING_ERROR;
- // tira su il bit...
- plcWatchdog = true;
- return MEM_RWBoolean(W, true, 0, NC_WATCHDOG.MemType, NC_WATCHDOG.Address, NC_WATCHDOG.SubAddress, 0, ref plcWatchdog);
- }
-
- ///
- /// Active message list
- ///
- ///
- ///
- public override CmsError PLC_RActiveMessages(ref List alarms)
- {
- // FIXME TODO controllare
- bool[] statusBits;
- int i = 0;
- List readValues = new List();
- List currMem = new List();
- CmsError libraryError;
- try
- {
- alarms.Clear();
-
- // Read on data from memory
- libraryError = MEM_RWIntegerList(R, 0,
- ALARMS_STATUS.MemType,
- ALARMS_STATUS.Address,
- ALARMS_STATUS.SubAddress,
- (ALARMS_STATUS.Size / 4) + (ALARMS_DATA.Size / 2), // status_bytes / 4 + data_word / 2
- ref readValues);
-
- if (libraryError.IsError())
- return libraryError;
-
- // leggo a BYTE
- libraryError = MEM_RWByteList(R, 0,
- ALARMS_STATUS.MemType,
- ALARMS_STATUS.Address,
- ALARMS_STATUS.SubAddress,
- 0,
- (ALARMS_STATUS.Size), // status_bytes
- ref currMem);
-
- if (libraryError.IsError())
- return libraryError;
-
- alarms.Clear();
-
- // Convert integer array into bit array
- statusBits = IntToBits(readValues.ToArray());
-
- BitArray bArray = new BitArray(currMem.ToArray());
-
- for (i = 0; i < ALARMS_STATUS.Size * 8; i++)
+ ///
+ /// Get the processes-count configurated
+ ///
+ ///
+ ///
+ public override CmsError NC_RProcessesNum(ref ushort ProcNumber)
{
- // If alarm is active
- if (bArray[i])
- {
- // Calculate matching alarm byte info address
- int dataByteAddress = (i * 16) + ALARMS_NUMBER;
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
- var processList = new List();
+ ProcNumber = (ushort)ConfChannelNo;
- // Get processes on which alarm is active
- for (int j = dataByteAddress; j < dataByteAddress + 6; j++)
+ return NO_ERROR;
+ }
+
+ ///
+ /// Get the NC model Name
+ ///
+ ///
+ ///
+ public override CmsError NC_RModelName(ref string ModelName)
+ {
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
+
+ ModelName = Cnc_name;
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Get the NC Software Version
+ ///
+ ///
+ ///
+ public override CmsError NC_RSoftwareVersion(ref string SWV)
+ {
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
+
+ SWV = Cnc_SftVersion;
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Get the NC Language
+ ///
+ ///
+ ///
+ public override CmsError NC_RLanguage(ref CultureInfo Language)
+ {
+ // Read static data
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
+
+ Language = ConvertToSTEPLanguage(S7Language);
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Set the NC Language
+ ///
+ ///
+ ///
+ public override CmsError NC_WLanguage(CultureInfo Language)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ ///
+ /// Get the NC Serial number
+ ///
+ ///
+ ///
+ public override CmsError NC_RSerialNumber(ref string serialNumber)
+ {
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
+
+ serialNumber = Cnc_SeriesNum;
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Get CMS Machine number
+ ///
+ ///
+ ///
+ ///
+ public override CmsError NC_RMachineNumber(bool hasLetters, ref string MachNumber)
+ {
+ if (!hasLetters)
{
- if (statusBits[j])
- processList.Add(j + 1 - dataByteAddress);
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
+
+ MachNumber = Cms_MachNumber;
}
- // Add alarm info into active alarms list
- alarms.Add(new PlcAlarmModel()
+ else
{
- Id = (uint)i + 1,
- IsWarning = statusBits[dataByteAddress + 7],
- RestorationIsActive = statusBits[dataByteAddress + 6],
- Process = processList
- });
- }
- }
- }
- catch (Exception ex)
- {
- return ManageException(ex);
- }
+ // New method to read machine number
+ List lists = new List();
+ CmsError libraryError = MEM_RWByteList(R, 0, NEW_MATR_MACC.MemType, NEW_MATR_MACC.Address, NEW_MATR_MACC.SubAddress, 0, 4, ref lists);
+ if (libraryError.IsError())
+ return libraryError;
- return NO_ERROR;
- }
+ lists.Reverse();
- public override CmsError PLC_WRestoreMessage(uint id)
- {
- // Check id range
- if (id > ALARMS_NUMBER)
- return INCORRECT_PARAMETERS_ERROR;
+ MachNumber = Encoding.ASCII.GetString(lists.ToArray().Reverse().ToArray());
+ }
- // Call restore message: is a BIT ARRAY --> true!
- CmsError libraryError = PLC_WStrobe(true, ALARM_ACK, ALARM_RESTORATION_STROBE, id);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WRefreshMessage(uint id)
- {
- // Check id range
- if (id > ALARMS_NUMBER)
- return INCORRECT_PARAMETERS_ERROR;
-
- // Call restore message: is a BIT ARRAY --> false!
- CmsError libraryError = PLC_WStrobe(false, ALARM_ACK, ALARM_REFRESH_STROBE, id);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WRefreshAllMessages()
- {
- // imposto come UserSoftKey
- return PLC_WUserSoftKey(REFRESH_ALL_ALARMS_SFKEY_INDEX);
- }
-
- public override CmsError PLC_RPowerOnData(ref PreAndPostPowerOnModel powerOnModel)
- {
- //int readValue = 0;
- //// Read pre power on and post power on data from memory
- //CmsError libraryError = MEM_RWInteger(R, 0, PRE_POST_POWER_ON.MemType, PRE_POST_POWER_ON.Address, PRE_POST_POWER_ON.SubAddress, ref readValue);
- CmsError libraryError = NO_ERROR;
-
- List currMem = new List();
- libraryError = MEM_RWByteList(R, 0, PRE_POST_POWER_ON.MemType, PRE_POST_POWER_ON.Address, PRE_POST_POWER_ON.SubAddress, 0, 4, ref currMem);
-
- if (libraryError.IsError())
- return libraryError;
-
- bool[] bits = new bool[32];
-
- // Convert int into to true/false array
- //bits = IntToBits(readValue);
- var bArray = new BitArray(currMem.ToArray());
- bArray.CopyTo(bits, 0);
-
- // Create adn set pre power on object
- PrePowerOnModel prePowerOn = new PrePowerOnModel()
- {
- PowerOn = new PowerOnDataModel() { Id = 1, Active = bits[0], Clickable = bits[16] }, // id = N, bits = N, Clickable = N + 8 (Second bit)
- AirPressure = new PowerOnDataModel() { Id = 2, Active = bits[1], Clickable = bits[17] },
- ProtectionStatus = new PowerOnDataModel() { Id = 3, Active = bits[2], Clickable = bits[18] },
- EmergencyButtons = new PowerOnDataModel() { Id = 4, Active = bits[3], Clickable = bits[19] },
- SettingMode = new PowerOnDataModel() { Id = 5, Active = bits[4], Clickable = bits[20] },
- StartingKey = new PowerOnDataModel() { Id = 6, Active = bits[5], Clickable = bits[21] },
- BarriersNotOk = new PowerOnDataModel() { Id = 7, Active = bits[6], Clickable = bits[22] }
- };
-
- // Create and set post power on object
- PostPowerOnModel postPowerOn = new PostPowerOnModel()
- {
- AxisReset = new PowerOnDataModel() { Id = 9, Active = bits[8], Clickable = bits[24] }, // id = N - 8, bits = N, Clickable = N + 8 (Second bit)
- WaterjetPump = new PowerOnDataModel() { Id = 10, Active = bits[9], Clickable = bits[25] }
- };
-
- powerOnModel = new PreAndPostPowerOnModel()
- {
- PostPowerOn = postPowerOn,
- PrePowerOn = prePowerOn
- };
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WPowerOnData(uint id, bool value)
- {
- // Check bit range
- if (id > 16)
- return INCORRECT_PARAMETERS_ERROR;
-
- // Call restore message
- CmsError libraryError = PLC_WStrobe(false, PRE_POST_POWER_ON_ACK, PRE_POST_POWER_ON_CLICKED, id);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_RFunctionAccess(ref List functions)
- {
- List readValues = new List();
- int numberOfIntegers = FUNCTION_ACCESS.Size / 4;
- // Read functions access data from memory
- CmsError libraryError = MEM_RWIntegerList(R, 0, FUNCTION_ACCESS.MemType, FUNCTION_ACCESS.Address, FUNCTION_ACCESS.SubAddress, numberOfIntegers, ref readValues);
- if (libraryError.IsError())
- return libraryError;
-
- functions = new List();
- // Convert int into to true/false array
- bool[] bits = IntToBits(readValues.ToArray());
- // Convert array into structured data
- for (int i = 0; i < bits.Count(); i++)
- {
- functions.Add(new FunctionalityModel()
- {
- Id = (uint)i + 1,
- // forzo a true perché non gestita dal PLC
- IsActive = true //bits[i]
- });
- }
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_RAxesResetData(ref AxisResetDataModel axisResetData)
- {
- byte value = 0;
- // Read byte from memory
- CmsError libraryError = MEM_RWByte(R, true, 0, AXIS_RESET_PROCEDURE.MemType, AXIS_RESET_PROCEDURE.Address, AXIS_RESET_PROCEDURE.SubAddress, 0, ref value);
- if (libraryError.IsError())
- return libraryError;
-
- // Check last bit if is active
- if ((value & 128) == 128)
- {
- // Set to 0 last bit( isActive bit x - 128 )
- // From 0 to 6 bit represents percentage
- // If higher than 100 then value = 100
- byte percentage = value - 128 > 100 ? (byte)100 : (byte)(value - 128);
- axisResetData = new AxisResetDataModel()
- {
- IsActive = true,
- Percentage = percentage
- };
- }
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_RUserSoftKeys(ref List softKeys)
- {
- CmsError libraryError = PLC_RSoftKeys(USER_SOFTKEYS_VALUE, USER_SOFTKEYS_CLICKABLE, ref softKeys);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- private CmsError PLC_RSoftKeys(MEMORY_CELL softKeyStatusMemory, MEMORY_CELL softKeysClickableMemory, ref List softKeys)
- {
- softKeys = new List();
- List readValues = new List();
-
- int memorySizeToRead = (softKeyStatusMemory.Size + softKeysClickableMemory.Size);
- // Offset between status and clickable data
- int offset = softKeyStatusMemory.Size * 8;
-
- // Read on data from memory
- CmsError libraryError = MEM_RWIntegerList(R, 0,
- softKeyStatusMemory.MemType,
- softKeyStatusMemory.Address,
- softKeyStatusMemory.SubAddress,
- memorySizeToRead / 4,
- ref readValues);
-
- if (libraryError.IsError())
- return libraryError;
-
- // need byte swap!
- List fixValues = new List();
- foreach (var item in readValues)
- {
- fixValues.Add(SwapBytes(item));
- }
- // Convert ints into an array of bools
- bool[] bits = IntToBits(fixValues.ToArray());
-
- // Convert array into structured data
- for (ushort i = 0; i < bits.Count() / 2; i++)
- {
- softKeys.Add(new SoftKeysModel()
- {
- Id = (uint)i + 1,
- Value = bits[i],
- Active = bits[i + offset]
- });
- }
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WUserSoftKey(uint id)
- {
- // Check id range
- if (id > USER_SOFTKEYS_NUMBER)
- return INCORRECT_PARAMETERS_ERROR;
-
- // Write strobe into memory --> false because is bitArray
- CmsError libraryError = PLC_WStrobe(false, USER_SOFT_KEYS_ACK, USER_SOFT_KEYS_CLICKED, id);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_RHeadsData(List heads, int number)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_RWorkedTimeHead(int head, ref uint time)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_WResetWorkedTimeHead(int head)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_RWorkedTimeMachine(ref uint time)
- {
- // Read Worked time
- CmsError libraryError = MEM_RWDWord(R, 0, MACHINE_WORKED_TIME.MemType, MACHINE_WORKED_TIME.Address, MACHINE_WORKED_TIME.SubAddress, ref time);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WResetWorkedTimeMachine(uint time)
- {
- //FIXME TODO verificare endianness aree memoria
-
- uint actTime = 0;
-
- // Read actual Value
- CmsError libraryError = MEM_RWDWord(R, 0, MACHINE_WORKED_TIME.MemType, MACHINE_WORKED_TIME.Address, MACHINE_WORKED_TIME.SubAddress, ref actTime);
- if (libraryError.IsError())
- return libraryError;
-
- // Per richiedere l'azzeramento del timer invio 4 volte il segnale velocemente al PLC
- // Il PLC resetta il bit e aspetta quello successivo entro 500ms, se no abortisce
- // Sfrutto così la velocità dei sw, cosa che un "nemico" a mano se provasse a forzare il bit non avrebbe
- bool bitValue = true;
- int nTry = 0;
-
- for (int i = 0; i <= 4; i++)
- {
- //Scrivo il bit
- bitValue = true;
- nTry = 0;
- libraryError = MEM_RWBoolean(W, true, 0, MACHINE_RESET_WORKED_TIME.MemType, MACHINE_RESET_WORKED_TIME.Address, MACHINE_RESET_WORKED_TIME.SubAddress, 0, ref bitValue);
- if (libraryError.IsError())
- return libraryError;
-
- //Aspetto che venga abbassato
- do
- {
- Thread.Sleep(50);
- nTry += 1;
- libraryError = MEM_RWBoolean(R, true, 0, MACHINE_RESET_WORKED_TIME.MemType, MACHINE_RESET_WORKED_TIME.Address, MACHINE_RESET_WORKED_TIME.SubAddress, 0, ref bitValue);
- if (libraryError.IsError())
- return libraryError;
-
- } while (bitValue && nTry <= 10);
-
- //se il valore è rimasto a 1 il plc non l'ha preso in carico, e abortisco
- if (bitValue)
- {
- bitValue = true;
- libraryError = MEM_RWBoolean(W, true, 0, MACHINE_RESET_WORKED_TIME.MemType, MACHINE_RESET_WORKED_TIME.Address, MACHINE_RESET_WORKED_TIME.SubAddress, 0, ref bitValue);
- if (libraryError.IsError())
- return libraryError;
-
- return PLC_NOT_RUNNING_ERROR;
- }
- else
- {
- //Se l'ha abbassato scrivo il nuovo dato
- libraryError = MEM_RWDWord(W, 0, MACHINE_WORKED_TIME.MemType, MACHINE_WORKED_TIME.Address, MACHINE_WORKED_TIME.SubAddress, ref time);
+ return NO_ERROR;
}
- }
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WHeadOverride(uint id, HEAD_OVERRIDE_SIGN sign)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- // MACHINE COUNTERS
- public override CmsError PLC_RMachineCounters(ref List counters)
- {
- List val = new List();
- // Read ints
- CmsError libraryError = MEM_RWDWordList(R, 0, COUNTERS_DATA.MemType, COUNTERS_DATA.Address, COUNTERS_DATA.SubAddress, COUNTERS_DATA.Size / 4, ref val);
- if (libraryError.IsError())
- return libraryError;
-
- // Set return value
- uint i = 0;
- counters = val.Select(x => new CounterModel()
- {
- Id = i++,
- Value = x
- })
- .ToList();
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_WResetMachineCounters(uint counter)
- {
- // FIXME TODO verifica se endianness vada gestita o meno (qui FALSE)
- bool isResettable = false;
- CmsError libraryError = MEM_RWBoolean(R, false, 0, COUNTER_IS_RESETTABLE.MemType, COUNTER_IS_RESETTABLE.Address, COUNTER_IS_RESETTABLE.SubAddress, (int)(counter - 1), ref isResettable);
- if (libraryError.IsError())
- return libraryError;
-
- if (!isResettable)
- return FUNCTION_NOT_ALLOWED_ERROR;
-
- libraryError = PLC_WStrobe(false, COUNTER_IS_RESETTABLE_ACK, COUNTER_IS_RESETTABLE_STROBE, counter);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
-
- public override CmsError PLC_ROperatorInputIsNeeded(ref List value)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_WOperatorInputResponse(int process, double responseVal)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_RM154Data(ref List data, ref bool MTCOnOff)
- {
- // FIXME TODO - levare? inserito anche endiannes
-
- MTCOnOff = false;
- CmsError libraryError = MEM_RWBoolean(R, true, 0, M154_SWITCH_ONOFF.MemType, M154_SWITCH_ONOFF.Address, M154_SWITCH_ONOFF.SubAddress, 1, ref MTCOnOff);
-
- if (libraryError.IsError())
- return libraryError;
-
- byte val = 0;
- libraryError = MEM_RWByte(R, true, 0, M154_STROBE.MemType, M154_STROBE.Address, M154_STROBE.SubAddress, 0, ref val);
- if (libraryError.IsError())
- return libraryError;
-
- // Convert a byte to an array of booleans
- bool[] bits = ByteToBits(val);
- string[] parameters;
- string tmpStr = "";
-
- for (uint processId = 1; processId <= MAX_PROCESS_NUMBER; processId++)
- {
- if (bits[processId - 1])
+ ///
+ /// Get the Date-Time of the NC
+ ///
+ ///
+ ///
+ public override CmsError NC_RDateTime(ref DateTime ActualTime)
{
- // Read active program line
- libraryError = PROC_ReadActiveLine(processId, ref tmpStr);
- if (libraryError.IsError())
- return libraryError;
-
- // Parse parameters
- parameters = ExtractM154ParametersFromNcCodeLine(tmpStr);
- data.Add(new M154DataModel()
- {
- Process = processId,
- IsNeeded = bits[processId - 1],
- Parameters = parameters
- });
+ ActualTime = DateTime.Now;
+ return NO_ERROR;
}
- }
- return NO_ERROR;
- }
-
- public override CmsError PLC_W154ManageAck(int processId)
- {
- return PLC_ManageActiveAck(M154_STROBE.Address, M154_STROBE.SubAddress, processId - 1, M154_ACK.Address, M154_ACK.SubAddress, processId - 1, M154_STROBE.MemType, true);
- }
-
- public override CmsError PLC_RM156Data(ref List value)
- {
- // NB: da verificare se sia corretto o meno come BIT ARRAY...
-
- byte val = 0;
- List vals = new List();
- CmsError libraryError = MEM_RWByte(R, false, 0, M156_INPUT_NEEDED.MemType, M156_INPUT_NEEDED.Address, M156_INPUT_NEEDED.SubAddress, 0, ref val);
- if (libraryError.IsError())
- return libraryError;
-
- libraryError = MEM_RWByteList(R, 0, M156_INPUT_ID_LIST.MemType, M156_INPUT_ID_LIST.Address, M156_INPUT_ID_LIST.SubAddress, 0, M156_INPUT_ID_LIST.Size, ref vals);
- if (libraryError.IsError())
- return libraryError;
-
- bool[] bits = ByteToBits(val);
-
- // FORZO: 1 solo processo
- //for (int processId = 1; processId <= MAX_PROCESS_NUMBER; processId++)
- for (int processId = 1; processId <= 1; processId++)
- {
- if (bits[processId - 1])
+ ///
+ /// Check if the NC is in running state
+ ///
+ ///
+ ///
+ public override CmsError NC_RIsRunning(ref bool running)
{
- // leggo x compatibilità la risposta standard
- double responseVal = 0;
- // Read machine variable
- libraryError = MEM_RWDouble(R, 0, M156_RESPONSE_MEMORY.MemType, M156_RESPONSE_MEMORY.Address, M156_RESPONSE_MEMORY.SubAddress + (int)processId - 1, ref responseVal);
- if (libraryError.IsError())
- return libraryError;
- // Parse line & get parameters
- value.Add(new M156InputIsNeededModel()
- {
- Process = (uint)processId,
- Id = vals.ElementAt(processId - 1),
- Value = responseVal
- });
+ ushort nProcess = 0;
+ // Get the number of processes
+ CmsError libraryError = NC_RProcessesNum(ref nProcess);
+ if (libraryError.IsError())
+ return libraryError;
+
+ ushort i = 1;
+ running = false;
+ do
+ {
+ PROC_STATUS procStatus = PROC_STATUS.IDLE;
+
+ // Read process status
+ libraryError = PROC_RStatus(i, ref procStatus);
+ if (libraryError.IsError())
+ return libraryError;
+
+ if (procStatus == PROC_STATUS.RUN)
+ running = true;
+ i++;
+ } while (!running || i <= nProcess);
+
+ return NO_ERROR;
}
- }
- return NO_ERROR;
- }
-
- public override CmsError PLC_WM156Response(int process, double responseVal)
- {
- // forzo process a 1...
- process = 1;
- CmsError libraryError = MEM_RWDouble(W, 0, M156_RESPONSE_MEMORY.MemType, M156_RESPONSE_MEMORY.Address, M156_RESPONSE_MEMORY.SubAddress + (int)process - 1, ref responseVal);
- if (libraryError.IsError())
- return libraryError;
-
- // FIXME TODO verifica se endianness vada gestita o meno (qui FALSE)
- return PLC_WStrobe(false, M156_INPUT_ACK, M156_INPUT_STROBE, (uint)process);
- }
-
- public override CmsError PLC_RScadaValue(string memIndex, SCADA_MEM_TYPE memType, ref object value)
- {
- if (memType == SCADA_MEM_TYPE.BOOL)
- {
- if (memIndex.ToUpper() == "FALSE")
+ ///
+ /// Get NC unit of measure
+ ///
+ ///
+ ///
+ public override CmsError NC_RUnitOfMeasure(ref string unitOfMeasure)
{
- value = false;
- return NO_ERROR;
+ CmsError libraryError = ReadStaticNCData();
+ if (libraryError.IsError())
+ return libraryError;
+
+ unitOfMeasure = UnitOfMeasure;
+
+ return NO_ERROR;
}
- else if (memIndex.ToUpper() == "TRUE")
+
+ ///
+ /// Get the Nc Active Alarms
+ ///
+ ///
+ ///
+ public override CmsError NC_RActiveAlarms(ref List alarms)
{
- value = true;
- return NO_ERROR;
+ return NO_ERROR;
}
- }
- string[] index = memIndex.Split('.');
- CmsError libraryError = NO_ERROR;
- try
- {
- if (index.Count() == 0 || index.Count() == 1)
- return INCORRECT_PARAMETERS_ERROR;
- else if (index.Count() == 2)
+ ///
+ /// Set the Nc Active Page of the NC
+ ///
+ ///
+ ///
+ public override CmsError NC_SetScreenVisible(SCREEN_PAGE screen)
{
- if (memType == SCADA_MEM_TYPE.INT)
- {
- // read INT
- int val = 0;
- libraryError = MEM_RWInteger(R, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
- value = val;
- }
- else if (memType == SCADA_MEM_TYPE.WORD)
- { // read WORD
- short val = 0;
- libraryError = MEM_RWShort(R, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ public override CmsError NC_WMDICommand(int processId, string mdiString)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
- value = val;
- }
- else if (memType == SCADA_MEM_TYPE.REAL)
- { // read DOUBLE
- double val = 0;
- libraryError = MEM_RWDouble(R, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ #endregion High level methods
+
+ ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
+
+ #region PLC High-level data
+
+ public override CmsError PLC_RWManageWatchdog()
+ {
+ // watchdog in memoria WORD --> true x endianness!
+ bool plcWatchdog = false;
+ CmsError libraryError = MEM_RWBoolean(R, true, 0, NC_WATCHDOG.MemType, NC_WATCHDOG.Address, NC_WATCHDOG.SubAddress, 0, ref plcWatchdog);
+ if (libraryError.IsError())
+ return libraryError;
+
+ if (plcWatchdog)
+ return PLC_NOT_RUNNING_ERROR;
+ // tira su il bit...
+ plcWatchdog = true;
+ return MEM_RWBoolean(W, true, 0, NC_WATCHDOG.MemType, NC_WATCHDOG.Address, NC_WATCHDOG.SubAddress, 0, ref plcWatchdog);
+ }
+
+ ///
+ /// Active message list
+ ///
+ ///
+ ///
+ public override CmsError PLC_RActiveMessages(ref List alarms)
+ {
+ // FIXME TODO controllare
+ bool[] statusBits;
+ int i = 0;
+ List readValues = new List();
+ List currMem = new List();
+ CmsError libraryError;
+ try
+ {
+ alarms.Clear();
+
+ // Read on data from memory
+ libraryError = MEM_RWIntegerList(R, 0,
+ ALARMS_STATUS.MemType,
+ ALARMS_STATUS.Address,
+ ALARMS_STATUS.SubAddress,
+ (ALARMS_STATUS.Size / 4) + (ALARMS_DATA.Size / 2), // status_bytes / 4 + data_word / 2
+ ref readValues);
+
+ if (libraryError.IsError())
+ return libraryError;
+
+ // leggo a BYTE
+ libraryError = MEM_RWByteList(R, 0,
+ ALARMS_STATUS.MemType,
+ ALARMS_STATUS.Address,
+ ALARMS_STATUS.SubAddress,
+ 0,
+ (ALARMS_STATUS.Size), // status_bytes
+ ref currMem);
+
+ if (libraryError.IsError())
+ return libraryError;
+
+ alarms.Clear();
+
+ // Convert integer array into bit array
+ statusBits = IntToBits(readValues.ToArray());
+
+ BitArray bArray = new BitArray(currMem.ToArray());
+
+ for (i = 0; i < ALARMS_STATUS.Size * 8; i++)
+ {
+ // If alarm is active
+ if (bArray[i])
+ {
+ // Calculate matching alarm byte info address
+ int dataByteAddress = (i * 16) + ALARMS_NUMBER;
+
+ var processList = new List();
+
+ // Get processes on which alarm is active
+ for (int j = dataByteAddress; j < dataByteAddress + 6; j++)
+ {
+ if (statusBits[j])
+ processList.Add(j + 1 - dataByteAddress);
+ }
+ // Add alarm info into active alarms list
+ alarms.Add(new PlcAlarmModel()
+ {
+ Id = (uint)i + 1,
+ IsWarning = statusBits[dataByteAddress + 7],
+ RestorationIsActive = statusBits[dataByteAddress + 6],
+ Process = processList
+ });
+ }
+ }
+ }
+ catch (Exception ex)
+ {
+ return ManageException(ex);
+ }
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WRestoreMessage(uint id)
+ {
+ // Check id range
+ if (id > ALARMS_NUMBER)
+ return INCORRECT_PARAMETERS_ERROR;
+
+ // Call restore message: is a BIT ARRAY --> true!
+ CmsError libraryError = PLC_WStrobe(true, ALARM_ACK, ALARM_RESTORATION_STROBE, id);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WRefreshMessage(uint id)
+ {
+ // Check id range
+ if (id > ALARMS_NUMBER)
+ return INCORRECT_PARAMETERS_ERROR;
+
+ // Call restore message: is a BIT ARRAY --> false!
+ CmsError libraryError = PLC_WStrobe(false, ALARM_ACK, ALARM_REFRESH_STROBE, id);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WRefreshAllMessages()
+ {
+ // imposto come UserSoftKey
+ return PLC_WUserSoftKey(REFRESH_ALL_ALARMS_SFKEY_INDEX);
+ }
+
+ public override CmsError PLC_RPowerOnData(ref PreAndPostPowerOnModel powerOnModel)
+ {
+ //int readValue = 0;
+ //// Read pre power on and post power on data from memory
+ //CmsError libraryError = MEM_RWInteger(R, 0, PRE_POST_POWER_ON.MemType, PRE_POST_POWER_ON.Address, PRE_POST_POWER_ON.SubAddress, ref readValue);
+ CmsError libraryError = NO_ERROR;
+
+ List currMem = new List();
+ libraryError = MEM_RWByteList(R, 0, PRE_POST_POWER_ON.MemType, PRE_POST_POWER_ON.Address, PRE_POST_POWER_ON.SubAddress, 0, 4, ref currMem);
+
+ if (libraryError.IsError())
+ return libraryError;
+
+ bool[] bits = new bool[32];
+
+ // Convert int into to true/false array
+ //bits = IntToBits(readValue);
+ var bArray = new BitArray(currMem.ToArray());
+ bArray.CopyTo(bits, 0);
+
+ // Create adn set pre power on object
+ PrePowerOnModel prePowerOn = new PrePowerOnModel()
+ {
+ PowerOn = new PowerOnDataModel() { Id = 1, Active = bits[0], Clickable = bits[16] }, // id = N, bits = N, Clickable = N + 8 (Second bit)
+ AirPressure = new PowerOnDataModel() { Id = 2, Active = bits[1], Clickable = bits[17] },
+ ProtectionStatus = new PowerOnDataModel() { Id = 3, Active = bits[2], Clickable = bits[18] },
+ EmergencyButtons = new PowerOnDataModel() { Id = 4, Active = bits[3], Clickable = bits[19] },
+ SettingMode = new PowerOnDataModel() { Id = 5, Active = bits[4], Clickable = bits[20] },
+ StartingKey = new PowerOnDataModel() { Id = 6, Active = bits[5], Clickable = bits[21] },
+ BarriersNotOk = new PowerOnDataModel() { Id = 7, Active = bits[6], Clickable = bits[22] }
+ };
+
+ // Create and set post power on object
+ PostPowerOnModel postPowerOn = new PostPowerOnModel()
+ {
+ AxisReset = new PowerOnDataModel() { Id = 9, Active = bits[8], Clickable = bits[24] }, // id = N - 8, bits = N, Clickable = N + 8 (Second bit)
+ WaterjetPump = new PowerOnDataModel() { Id = 10, Active = bits[9], Clickable = bits[25] }
+ };
+
+ powerOnModel = new PreAndPostPowerOnModel()
+ {
+ PostPowerOn = postPowerOn,
+ PrePowerOn = prePowerOn
+ };
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WPowerOnData(uint id, bool value)
+ {
+ // Check bit range
+ if (id > 16)
+ return INCORRECT_PARAMETERS_ERROR;
+
+ // Call restore message
+ CmsError libraryError = PLC_WStrobe(false, PRE_POST_POWER_ON_ACK, PRE_POST_POWER_ON_CLICKED, id);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_RFunctionAccess(ref List functions)
+ {
+ List readValues = new List();
+ int numberOfIntegers = FUNCTION_ACCESS.Size / 4;
+ // Read functions access data from memory
+ CmsError libraryError = MEM_RWIntegerList(R, 0, FUNCTION_ACCESS.MemType, FUNCTION_ACCESS.Address, FUNCTION_ACCESS.SubAddress, numberOfIntegers, ref readValues);
+ if (libraryError.IsError())
+ return libraryError;
+
+ functions = new List();
+ // Convert int into to true/false array
+ bool[] bits = IntToBits(readValues.ToArray());
+ // Convert array into structured data
+ for (int i = 0; i < bits.Count(); i++)
+ {
+ functions.Add(new FunctionalityModel()
+ {
+ Id = (uint)i + 1,
+ // forzo a true perché non gestita dal PLC
+ IsActive = true //bits[i]
+ });
+ }
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_RAxesResetData(ref AxisResetDataModel axisResetData)
+ {
+ byte value = 0;
+ // Read byte from memory
+ CmsError libraryError = MEM_RWByte(R, true, 0, AXIS_RESET_PROCEDURE.MemType, AXIS_RESET_PROCEDURE.Address, AXIS_RESET_PROCEDURE.SubAddress, 0, ref value);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Check last bit if is active
+ if ((value & 128) == 128)
+ {
+ // Set to 0 last bit( isActive bit x - 128 )
+ // From 0 to 6 bit represents percentage
+ // If higher than 100 then value = 100
+ byte percentage = value - 128 > 100 ? (byte)100 : (byte)(value - 128);
+ axisResetData = new AxisResetDataModel()
+ {
+ IsActive = true,
+ Percentage = percentage
+ };
+ }
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_RUserSoftKeys(ref List softKeys)
+ {
+ CmsError libraryError = PLC_RSoftKeys(USER_SOFTKEYS_VALUE, USER_SOFTKEYS_CLICKABLE, ref softKeys);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ private CmsError PLC_RSoftKeys(MEMORY_CELL softKeyStatusMemory, MEMORY_CELL softKeysClickableMemory, ref List softKeys)
+ {
+ softKeys = new List();
+ List readValues = new List();
+
+ int memorySizeToRead = (softKeyStatusMemory.Size + softKeysClickableMemory.Size);
+ // Offset between status and clickable data
+ int offset = softKeyStatusMemory.Size * 8;
+
+ // Read on data from memory
+ CmsError libraryError = MEM_RWIntegerList(R, 0,
+ softKeyStatusMemory.MemType,
+ softKeyStatusMemory.Address,
+ softKeyStatusMemory.SubAddress,
+ memorySizeToRead / 4,
+ ref readValues);
+
+ if (libraryError.IsError())
+ return libraryError;
+
+ // need byte swap!
+ List fixValues = new List();
+ foreach (var item in readValues)
+ {
+ fixValues.Add(SwapBytes(item));
+ }
+ // Convert ints into an array of bools
+ bool[] bits = IntToBits(fixValues.ToArray());
+
+ // Convert array into structured data
+ for (ushort i = 0; i < bits.Count() / 2; i++)
+ {
+ softKeys.Add(new SoftKeysModel()
+ {
+ Id = (uint)i + 1,
+ Value = bits[i],
+ Active = bits[i + offset]
+ });
+ }
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WUserSoftKey(uint id)
+ {
+ // Check id range
+ if (id > USER_SOFTKEYS_NUMBER)
+ return INCORRECT_PARAMETERS_ERROR;
+
+ // Write strobe into memory --> false because is bitArray
+ CmsError libraryError = PLC_WStrobe(false, USER_SOFT_KEYS_ACK, USER_SOFT_KEYS_CLICKED, id);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_RHeadsData(List heads, int number)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ public override CmsError PLC_RWorkedTimeHead(int head, ref uint time)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ public override CmsError PLC_WResetWorkedTimeHead(int head)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ public override CmsError PLC_RWorkedTimeMachine(ref uint time)
+ {
+ // Read Worked time
+ CmsError libraryError = MEM_RWDWord(R, 0, MACHINE_WORKED_TIME.MemType, MACHINE_WORKED_TIME.Address, MACHINE_WORKED_TIME.SubAddress, ref time);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WResetWorkedTimeMachine(uint time)
+ {
+ //FIXME TODO verificare endianness aree memoria
+
+ uint actTime = 0;
+
+ // Read actual Value
+ CmsError libraryError = MEM_RWDWord(R, 0, MACHINE_WORKED_TIME.MemType, MACHINE_WORKED_TIME.Address, MACHINE_WORKED_TIME.SubAddress, ref actTime);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Per richiedere l'azzeramento del timer invio 4 volte il segnale velocemente al PLC
+ // Il PLC resetta il bit e aspetta quello successivo entro 500ms, se no abortisce
+ // Sfrutto così la velocità dei sw, cosa che un "nemico" a mano se provasse a forzare il bit non avrebbe
+ bool bitValue = true;
+ int nTry = 0;
+
+ for (int i = 0; i <= 4; i++)
+ {
+ //Scrivo il bit
+ bitValue = true;
+ nTry = 0;
+ libraryError = MEM_RWBoolean(W, true, 0, MACHINE_RESET_WORKED_TIME.MemType, MACHINE_RESET_WORKED_TIME.Address, MACHINE_RESET_WORKED_TIME.SubAddress, 0, ref bitValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ //Aspetto che venga abbassato
+ do
+ {
+ Thread.Sleep(50);
+ nTry += 1;
+ libraryError = MEM_RWBoolean(R, true, 0, MACHINE_RESET_WORKED_TIME.MemType, MACHINE_RESET_WORKED_TIME.Address, MACHINE_RESET_WORKED_TIME.SubAddress, 0, ref bitValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ } while (bitValue && nTry <= 10);
+
+ //se il valore è rimasto a 1 il plc non l'ha preso in carico, e abortisco
+ if (bitValue)
+ {
+ bitValue = true;
+ libraryError = MEM_RWBoolean(W, true, 0, MACHINE_RESET_WORKED_TIME.MemType, MACHINE_RESET_WORKED_TIME.Address, MACHINE_RESET_WORKED_TIME.SubAddress, 0, ref bitValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return PLC_NOT_RUNNING_ERROR;
+ }
+ else
+ {
+ //Se l'ha abbassato scrivo il nuovo dato
+ libraryError = MEM_RWDWord(W, 0, MACHINE_WORKED_TIME.MemType, MACHINE_WORKED_TIME.Address, MACHINE_WORKED_TIME.SubAddress, ref time);
+ }
+
+ }
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WHeadOverride(uint id, HEAD_OVERRIDE_SIGN sign)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ // MACHINE COUNTERS
+ public override CmsError PLC_RMachineCounters(ref List counters)
+ {
+ List val = new List();
+ // Read ints
+ CmsError libraryError = MEM_RWDWordList(R, 0, COUNTERS_DATA.MemType, COUNTERS_DATA.Address, COUNTERS_DATA.SubAddress, COUNTERS_DATA.Size / 4, ref val);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Set return value
+ uint i = 0;
+ counters = val.Select(x => new CounterModel()
+ {
+ Id = i++,
+ Value = x
+ })
+ .ToList();
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_WResetMachineCounters(uint counter)
+ {
+ // FIXME TODO verifica se endianness vada gestita o meno (qui FALSE)
+ bool isResettable = false;
+ CmsError libraryError = MEM_RWBoolean(R, false, 0, COUNTER_IS_RESETTABLE.MemType, COUNTER_IS_RESETTABLE.Address, COUNTER_IS_RESETTABLE.SubAddress, (int)(counter - 1), ref isResettable);
+ if (libraryError.IsError())
+ return libraryError;
+
+ if (!isResettable)
+ return FUNCTION_NOT_ALLOWED_ERROR;
+
+ libraryError = PLC_WStrobe(false, COUNTER_IS_RESETTABLE_ACK, COUNTER_IS_RESETTABLE_STROBE, counter);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+
+ public override CmsError PLC_ROperatorInputIsNeeded(ref List value)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ public override CmsError PLC_WOperatorInputResponse(int process, double responseVal)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ public override CmsError PLC_RM154Data(ref List data, ref bool MTCOnOff)
+ {
+ // FIXME TODO - levare? inserito anche endiannes
+
+ MTCOnOff = false;
+ CmsError libraryError = MEM_RWBoolean(R, true, 0, M154_SWITCH_ONOFF.MemType, M154_SWITCH_ONOFF.Address, M154_SWITCH_ONOFF.SubAddress, 1, ref MTCOnOff);
+
+ if (libraryError.IsError())
+ return libraryError;
- value = val;
- }
- else
- {
- // FIXME TODO verificare endianness (qui true)
- // read BYTE
byte val = 0;
- libraryError = MEM_RWByte(R, true, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), 0, ref val);
+ libraryError = MEM_RWByte(R, true, 0, M154_STROBE.MemType, M154_STROBE.Address, M154_STROBE.SubAddress, 0, ref val);
+ if (libraryError.IsError())
+ return libraryError;
- value = val;
- }
+ // Convert a byte to an array of booleans
+ bool[] bits = ByteToBits(val);
+ string[] parameters;
+ string tmpStr = "";
+
+ for (uint processId = 1; processId <= MAX_PROCESS_NUMBER; processId++)
+ {
+ if (bits[processId - 1])
+ {
+ // Read active program line
+ libraryError = PROC_ReadActiveLine(processId, ref tmpStr);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Parse parameters
+ parameters = ExtractM154ParametersFromNcCodeLine(tmpStr);
+ data.Add(new M154DataModel()
+ {
+ Process = processId,
+ IsNeeded = bits[processId - 1],
+ Parameters = parameters
+ });
+ }
+ }
+
+ return NO_ERROR;
}
- else if (index.Count() == 3 && memType == SCADA_MEM_TYPE.BOOL)
+
+ public override CmsError PLC_W154ManageAck(int processId)
{
- // FIXME TODO verificare endianness, qui false
- // read BOOL
- bool val = false;
- libraryError = MEM_RWBoolean(R, false, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), Convert.ToInt32(index[2]), ref val);
-
- value = val;
+ return PLC_ManageActiveAck(M154_STROBE.Address, M154_STROBE.SubAddress, processId - 1, M154_ACK.Address, M154_ACK.SubAddress, processId - 1, M154_STROBE.MemType, true);
}
- }
- catch (Exception ex)
- {
- return ManageException(ex);
- }
- return libraryError;
- }
-
- public override CmsError PLC_RScadaSiemens(ref List objects)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_WScadaValue(string memIndex, SCADA_MEM_TYPE memType, object value)
- {
- string[] index = memIndex.Split('.');
- CmsError libraryError = NO_ERROR;
- if (index.Count() == 0)
- return INCORRECT_PARAMETERS_ERROR;
-
- else if (index.Count() == 2)
- {
- if (memType == SCADA_MEM_TYPE.INT)
+ public override CmsError PLC_RM156Data(ref List value)
{
- // write INT
- int val = Convert.ToInt32(value);
- libraryError = MEM_RWInteger(W, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ // NB: da verificare se sia corretto o meno come BIT ARRAY...
+
+ byte val = 0;
+ List vals = new List();
+ CmsError libraryError = MEM_RWByte(R, false, 0, M156_INPUT_NEEDED.MemType, M156_INPUT_NEEDED.Address, M156_INPUT_NEEDED.SubAddress, 0, ref val);
+ if (libraryError.IsError())
+ return libraryError;
+
+ libraryError = MEM_RWByteList(R, 0, M156_INPUT_ID_LIST.MemType, M156_INPUT_ID_LIST.Address, M156_INPUT_ID_LIST.SubAddress, 0, M156_INPUT_ID_LIST.Size, ref vals);
+ if (libraryError.IsError())
+ return libraryError;
+
+ bool[] bits = ByteToBits(val);
+
+ // FORZO: 1 solo processo
+ //for (int processId = 1; processId <= MAX_PROCESS_NUMBER; processId++)
+ for (int processId = 1; processId <= 1; processId++)
+ {
+ if (bits[processId - 1])
+ {
+ // leggo x compatibilità la risposta standard
+ double responseVal = 0;
+ // Read machine variable
+ libraryError = MEM_RWDouble(R, 0, M156_RESPONSE_MEMORY.MemType, M156_RESPONSE_MEMORY.Address, M156_RESPONSE_MEMORY.SubAddress + (int)processId - 1, ref responseVal);
+ if (libraryError.IsError())
+ return libraryError;
+ // Parse line & get parameters
+ value.Add(new M156InputIsNeededModel()
+ {
+ Process = (uint)processId,
+ Id = vals.ElementAt(processId - 1),
+ Value = responseVal
+ });
+ }
+ }
+
+ return NO_ERROR;
}
- else if (memType == SCADA_MEM_TYPE.WORD)
- { // write WORD
- short val = Convert.ToInt16(value);
- libraryError = MEM_RWShort(W, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
- }
- else if (memType == SCADA_MEM_TYPE.REAL)
- { // write DOUBLE
- double val = Convert.ToDouble(value);
- libraryError = MEM_RWDouble(W, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
- }
- else
+
+ public override CmsError PLC_WM156Response(int process, double responseVal)
{
- // write byte
- byte val = Convert.ToByte(value);
- libraryError = MEM_RWByte(W, true, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), 0, ref val);
+ // forzo process a 1...
+ process = 1;
+ CmsError libraryError = MEM_RWDouble(W, 0, M156_RESPONSE_MEMORY.MemType, M156_RESPONSE_MEMORY.Address, M156_RESPONSE_MEMORY.SubAddress + (int)process - 1, ref responseVal);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // FIXME TODO verifica se endianness vada gestita o meno (qui FALSE)
+ return PLC_WStrobe(false, M156_INPUT_ACK, M156_INPUT_STROBE, (uint)process);
}
- }
- else if (index.Count() == 3 && memType == SCADA_MEM_TYPE.BOOL)
- {
- // write BOOL
- bool val = Convert.ToBoolean(value);
- libraryError = MEM_RWBoolean(W, false, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), Convert.ToInt32(index[2]), ref val);
- }
- return libraryError;
- }
-
- public override CmsError PLC_WAssistedToolingCmd(ushort toolId, ushort familyId, ushort shankId, ushort magazineId, ushort positionId, ASSISTED_TOOLING_ACTION action)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_RAssistedToolingData(ref AssistedToolingModel data)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError PLC_WTerminateAssistedToolingProcedure()
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
- ///
- /// Write strobe and manage ack from PLC
- ///
- /// Apply endianness swap (word=yes, bitArray=no)
- ///
- ///
- ///
- ///
- private CmsError PLC_WStrobe(bool fixEndian, MEMORY_CELL ackCell, MEMORY_CELL strobeCell, uint id)
- {
- CmsError libraryError;
- bool readValue = false;
- bool writeValue = true;
-
- SetupAckStrobeAddresses(ackCell.SubAddress, strobeCell.SubAddress, id, out int ackByte, out int strobeByte, out int alarmBitId);
-
- // Check Strobe
- libraryError = MEM_RWBoolean(R, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref readValue);
- if (libraryError.IsError())
- return libraryError;
-
- // se è true
- int n = 200;
- do
- {
- // Check Strobe
- libraryError = MEM_RWBoolean(R, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref readValue);
- Thread.Sleep(20);
- n--;
- } while (n > 0 && readValue);
-
- // If PLC is true --> reset
- if (readValue)
- {
- bool forceVal = false;
- libraryError = MEM_RWBoolean(W, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref forceVal);
- }
-
- // Check ACK
- libraryError = MEM_RWBoolean(R, fixEndian, 0, ackCell.MemType, ackCell.Address, ackByte, alarmBitId, ref readValue);
- if (libraryError.IsError())
- return libraryError;
-
- // If PLC it's performing another request then return
- if (readValue)
- return NO_ERROR;
-
- // Write strobe into memory
- libraryError = MEM_RWBoolean(W, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref writeValue);
- if (libraryError.IsError())
- return libraryError;
-
- // Reset wait ack = 1 and reset the strobe
- libraryError = ResetStrobe(alarmBitId, strobeByte, ackByte, ackCell.MemType, fixEndian);
- if (libraryError.IsError())
- return libraryError;
-
- return NO_ERROR;
- }
- ///
- /// Write ack for strobe received from PLC
- ///
- /// Apply endianness swap (word=yes, bitArray=no)
- ///
- ///
- ///
- ///
- private CmsError PLC_WAck(bool fixEndian, MEMORY_CELL ackCell, MEMORY_CELL strobeCell, uint id)
- {
- CmsError libraryError;
- bool readValue = false;
- bool writeValue = true;
-
- SetupAckStrobeAddresses(ackCell.SubAddress, strobeCell.SubAddress, id, out int ackByte, out int strobeByte, out int alarmBitId);
-
- // Check Strobe
- libraryError = MEM_RWBoolean(R, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref readValue);
- if (libraryError.IsError())
- return libraryError;
-
- // if there's a strobe --> give ack!!!
- if (readValue)
- {
- // abbasso ack se fosse su...
- libraryError = MEM_RWBoolean(W, fixEndian, 0, ackCell.MemType, ackCell.Address, ackByte, alarmBitId, ref writeValue);
- if (libraryError.IsError())
- return libraryError;
-
- // attendo 50ms...
- Thread.Sleep(50);
-
- // Reset wait ack = 1 and reset the strobe
- libraryError = ResetAck(alarmBitId, strobeByte, ackByte, ackCell.MemType, fixEndian);
- if (libraryError.IsError())
- return libraryError;
-
- // exit and next round will continue...
- return NO_ERROR;
- }
-
- return NO_ERROR;
- }
- ///
- /// Setup memory for ack/strobe processing
- ///
- /// base addr for ack zone
- /// base addr for strobe zone
- /// parameters to set (id 1...n)
- /// ack byte to use (OUT)
- /// strobe byte to use (out)
- /// bit 1..8
- private void SetupAckStrobeAddresses(int ackAddress, int strobeAddress, uint id, out int ackByte, out int strobeByte, out int bit)
- {
- ackByte = ackAddress + (((int)id - 1) / 8);
- strobeByte = strobeAddress + (((int)id - 1) / 8);
- bit = (((int)id - 1) % 8);
- }
-
- private CmsError ResetStrobe(int bitId, int strobeByte, int ackByte, MEMORY_TYPE memType, bool fixEndian)
- {
- int n = 200;
- bool readValue = false;
- bool writeValue = false;
- bool ok = false;
-
- CmsError libraryError;
- do
- {
- // Check ACK
- libraryError = MEM_RWBoolean(R, fixEndian, 0, memType, TABLE, ackByte, bitId, ref readValue);
- if (libraryError.IsError())
- return libraryError;
-
- // If true reset strobe
- if (readValue == true)
+ public override CmsError PLC_RScadaValue(string memIndex, SCADA_MEM_TYPE memType, ref object value)
{
- // Reset strobe
- libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, strobeByte, bitId, ref writeValue);
- if (libraryError.IsError())
+ if (memType == SCADA_MEM_TYPE.BOOL)
+ {
+ if (memIndex.ToUpper() == "FALSE")
+ {
+ value = false;
+ return NO_ERROR;
+ }
+ else if (memIndex.ToUpper() == "TRUE")
+ {
+ value = true;
+ return NO_ERROR;
+ }
+ }
+
+ string[] index = memIndex.Split('.');
+ CmsError libraryError = NO_ERROR;
+ try
+ {
+ if (index.Count() == 0 || index.Count() == 1)
+ return INCORRECT_PARAMETERS_ERROR;
+ else if (index.Count() == 2)
+ {
+ if (memType == SCADA_MEM_TYPE.INT)
+ {
+ // read INT
+ int val = 0;
+ libraryError = MEM_RWInteger(R, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+
+ value = val;
+ }
+ else if (memType == SCADA_MEM_TYPE.WORD)
+ { // read WORD
+ short val = 0;
+ libraryError = MEM_RWShort(R, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+
+ value = val;
+ }
+ else if (memType == SCADA_MEM_TYPE.REAL)
+ { // read DOUBLE
+ double val = 0;
+ libraryError = MEM_RWDouble(R, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+
+ value = val;
+ }
+ else
+ {
+ // FIXME TODO verificare endianness (qui true)
+ // read BYTE
+ byte val = 0;
+ libraryError = MEM_RWByte(R, true, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), 0, ref val);
+
+ value = val;
+ }
+ }
+ else if (index.Count() == 3 && memType == SCADA_MEM_TYPE.BOOL)
+ {
+ // FIXME TODO verificare endianness, qui false
+ // read BOOL
+ bool val = false;
+ libraryError = MEM_RWBoolean(R, false, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), Convert.ToInt32(index[2]), ref val);
+
+ value = val;
+ }
+ }
+ catch (Exception ex)
+ {
+ return ManageException(ex);
+ }
+
return libraryError;
- // Exit from cycle
- n = 0;
- ok = true;
}
- else
+
+ public override CmsError PLC_RScadaSiemens(ref List objects)
{
- // Decrement
- n--;
- // Wait befor next cycle
- Thread.Sleep(20);
+ return FUNCTION_NOT_ALLOWED_ERROR;
}
- } while (n > 0);
- if (!ok)
- {
- writeValue = false;
- // Reset strobe
- libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, strobeByte, bitId, ref writeValue);
- if (libraryError.IsError())
- return libraryError;
- }
-
- return libraryError;
- }
- private CmsError ResetAck(int bitId, int strobeByte, int ackByte, MEMORY_TYPE memType, bool fixEndian)
- {
- int n = 600;
- bool readValue = false;
- bool writeValue = false;
- bool ok = false;
-
- // aspetto 100ms
- Thread.Sleep(100);
-
- CmsError libraryError;
- do
- {
- // Check Strobe
- libraryError = MEM_RWBoolean(R, fixEndian, 0, memType, TABLE, strobeByte, bitId, ref readValue);
- if (libraryError.IsError())
- return libraryError;
-
- // If false reset ACK
- if (readValue == false)
+ public override CmsError PLC_WScadaValue(string memIndex, SCADA_MEM_TYPE memType, object value)
{
- // Reset strobe
- libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, ackByte, bitId, ref writeValue);
- if (libraryError.IsError())
+ string[] index = memIndex.Split('.');
+ CmsError libraryError = NO_ERROR;
+ if (index.Count() == 0)
+ return INCORRECT_PARAMETERS_ERROR;
+
+ else if (index.Count() == 2)
+ {
+ if (memType == SCADA_MEM_TYPE.INT)
+ {
+ // write INT
+ int val = Convert.ToInt32(value);
+ libraryError = MEM_RWInteger(W, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ }
+ else if (memType == SCADA_MEM_TYPE.WORD)
+ { // write WORD
+ short val = Convert.ToInt16(value);
+ libraryError = MEM_RWShort(W, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ }
+ else if (memType == SCADA_MEM_TYPE.REAL)
+ { // write DOUBLE
+ double val = Convert.ToDouble(value);
+ libraryError = MEM_RWDouble(W, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), ref val);
+ }
+ else
+ {
+ // write byte
+ byte val = Convert.ToByte(value);
+ libraryError = MEM_RWByte(W, true, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), 0, ref val);
+ }
+ }
+ else if (index.Count() == 3 && memType == SCADA_MEM_TYPE.BOOL)
+ {
+ // write BOOL
+ bool val = Convert.ToBoolean(value);
+ libraryError = MEM_RWBoolean(W, false, 0, MEMORY_TYPE.Siemens_DB, Convert.ToInt32(index[0]), Convert.ToInt32(index[1]), Convert.ToInt32(index[2]), ref val);
+ }
+
return libraryError;
- // Exit from cycle
- n = 0;
- ok = true;
}
- else
+
+ public override CmsError PLC_WAssistedToolingCmd(ushort toolId, ushort familyId, ushort shankId, ushort magazineId, ushort positionId, ASSISTED_TOOLING_ACTION action)
{
- // Decrement
- n--;
- // Wait befor next cycle
- Thread.Sleep(20);
+ return FUNCTION_NOT_ALLOWED_ERROR;
}
- } while (n > 0);
-
- if (!ok)
- {
- // Reset ack (forced)
- writeValue = false;
- libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, ackByte, bitId, ref writeValue);
- if (libraryError.IsError())
- return libraryError;
- }
-
- return libraryError;
- }
-
- private CmsError PLC_ManageActiveAck(int strobeByte, int strobeSubByte, int strobeBit, int ackByte, int ackSubByte, int ackBit, MEMORY_TYPE memType, bool fixEndian)
- {
- int n = 1200; // 30 seconds
- bool readValue = false;
- bool writeValue = true;
- bool ok = false;
- // Set ack to 1
- CmsError libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, ackByte, ackSubByte, ackBit, ref writeValue);
- if (libraryError.IsError())
- return libraryError;
-
- do
- {
- // Check strobe
- libraryError = MEM_RWBoolean(R, fixEndian, 0, memType, strobeByte, strobeSubByte, strobeBit, ref readValue);
- if (libraryError.IsError())
- return libraryError;
-
- // If true reset acknowledge
- if (!readValue)
+ public override CmsError PLC_RAssistedToolingData(ref AssistedToolingModel data)
{
- writeValue = false;
- // Reset acknowledge
- libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, ackByte, ackSubByte, ackBit, ref writeValue);
- if (libraryError.IsError())
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+
+ public override CmsError PLC_WTerminateAssistedToolingProcedure()
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
+ ///
+ /// Write strobe and manage ack from PLC
+ ///
+ /// Apply endianness swap (word=yes, bitArray=no)
+ ///
+ ///
+ ///
+ ///
+ private CmsError PLC_WStrobe(bool fixEndian, MEMORY_CELL ackCell, MEMORY_CELL strobeCell, uint id)
+ {
+ CmsError libraryError;
+ bool readValue = false;
+ bool writeValue = true;
+
+ SetupAckStrobeAddresses(ackCell.SubAddress, strobeCell.SubAddress, id, out int ackByte, out int strobeByte, out int alarmBitId);
+
+ // Check Strobe
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // se è true
+ int n = 200;
+ do
+ {
+ // Check Strobe
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref readValue);
+ Thread.Sleep(20);
+ n--;
+ } while (n > 0 && readValue);
+
+ // If PLC is true --> reset
+ if (readValue)
+ {
+ bool forceVal = false;
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref forceVal);
+ }
+
+ // Check ACK
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, ackCell.MemType, ackCell.Address, ackByte, alarmBitId, ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // If PLC it's performing another request then return
+ if (readValue)
+ return NO_ERROR;
+
+ // Write strobe into memory
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Reset wait ack = 1 and reset the strobe
+ libraryError = ResetStrobe(alarmBitId, strobeByte, ackByte, ackCell.MemType, fixEndian);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+ ///
+ /// Write ack for strobe received from PLC
+ ///
+ /// Apply endianness swap (word=yes, bitArray=no)
+ ///
+ ///
+ ///
+ ///
+ private CmsError PLC_WAck(bool fixEndian, MEMORY_CELL ackCell, MEMORY_CELL strobeCell, uint id)
+ {
+ CmsError libraryError;
+ bool readValue = false;
+ bool writeValue = true;
+
+ SetupAckStrobeAddresses(ackCell.SubAddress, strobeCell.SubAddress, id, out int ackByte, out int strobeByte, out int alarmBitId);
+
+ // Check Strobe
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, strobeCell.MemType, strobeCell.Address, strobeByte, alarmBitId, ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // if there's a strobe --> give ack!!!
+ if (readValue)
+ {
+ // abbasso ack se fosse su...
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, ackCell.MemType, ackCell.Address, ackByte, alarmBitId, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // attendo 50ms...
+ Thread.Sleep(50);
+
+ // Reset wait ack = 1 and reset the strobe
+ libraryError = ResetAck(alarmBitId, strobeByte, ackByte, ackCell.MemType, fixEndian);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // exit and next round will continue...
+ return NO_ERROR;
+ }
+
+ return NO_ERROR;
+ }
+ ///
+ /// Setup memory for ack/strobe processing
+ ///
+ /// base addr for ack zone
+ /// base addr for strobe zone
+ /// parameters to set (id 1...n)
+ /// ack byte to use (OUT)
+ /// strobe byte to use (out)
+ /// bit 1..8
+ private void SetupAckStrobeAddresses(int ackAddress, int strobeAddress, uint id, out int ackByte, out int strobeByte, out int bit)
+ {
+ ackByte = ackAddress + (((int)id - 1) / 8);
+ strobeByte = strobeAddress + (((int)id - 1) / 8);
+ bit = (((int)id - 1) % 8);
+ }
+
+ private CmsError ResetStrobe(int bitId, int strobeByte, int ackByte, MEMORY_TYPE memType, bool fixEndian)
+ {
+ int n = 200;
+ bool readValue = false;
+ bool writeValue = false;
+ bool ok = false;
+
+ CmsError libraryError;
+ do
+ {
+ // Check ACK
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, memType, TABLE, ackByte, bitId, ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // If true reset strobe
+ if (readValue == true)
+ {
+ // Reset strobe
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, strobeByte, bitId, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+ // Exit from cycle
+ n = 0;
+ ok = true;
+ }
+ else
+ {
+ // Decrement
+ n--;
+ // Wait befor next cycle
+ Thread.Sleep(20);
+ }
+ } while (n > 0);
+
+ if (!ok)
+ {
+ writeValue = false;
+ // Reset strobe
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, strobeByte, bitId, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+
return libraryError;
- // Exit from cycle
- n = 0;
- ok = true;
}
- else
+ private CmsError ResetAck(int bitId, int strobeByte, int ackByte, MEMORY_TYPE memType, bool fixEndian)
{
- // Decrement
- n--;
- // Wait befor next cycle
- Thread.Sleep(25);
+ int n = 600;
+ bool readValue = false;
+ bool writeValue = false;
+ bool ok = false;
+
+ // aspetto 100ms
+ Thread.Sleep(100);
+
+ CmsError libraryError;
+ do
+ {
+ // Check Strobe
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, memType, TABLE, strobeByte, bitId, ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // If false reset ACK
+ if (readValue == false)
+ {
+ // Reset strobe
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, ackByte, bitId, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+ // Exit from cycle
+ n = 0;
+ ok = true;
+ }
+ else
+ {
+ // Decrement
+ n--;
+ // Wait befor next cycle
+ Thread.Sleep(20);
+ }
+ } while (n > 0);
+
+
+ if (!ok)
+ {
+ // Reset ack (forced)
+ writeValue = false;
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, TABLE, ackByte, bitId, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+
+ return libraryError;
}
- } while (n > 0);
- // If loop timeout goes in timeout
- if (!ok)
- {
- // Reset acknowledge
- writeValue = false;
- libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, ackByte, ackSubByte, ackBit, ref writeValue);
- if (libraryError.IsError())
- return libraryError;
- }
+ private CmsError PLC_ManageActiveAck(int strobeByte, int strobeSubByte, int strobeBit, int ackByte, int ackSubByte, int ackBit, MEMORY_TYPE memType, bool fixEndian)
+ {
+ int n = 1200; // 30 seconds
+ bool readValue = false;
+ bool writeValue = true;
+ bool ok = false;
+ // Set ack to 1
+ CmsError libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, ackByte, ackSubByte, ackBit, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
- return libraryError;
- }
+ do
+ {
+ // Check strobe
+ libraryError = MEM_RWBoolean(R, fixEndian, 0, memType, strobeByte, strobeSubByte, strobeBit, ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
- public override CmsError PLC_WExpiredCandy(bool value)
- {
- bool newVal = false;
+ // If true reset acknowledge
+ if (!readValue)
+ {
+ writeValue = false;
+ // Reset acknowledge
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, ackByte, ackSubByte, ackBit, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+ // Exit from cycle
+ n = 0;
+ ok = true;
+ }
+ else
+ {
+ // Decrement
+ n--;
+ // Wait befor next cycle
+ Thread.Sleep(25);
+ }
+ } while (n > 0);
- //Scrivo il dato
- CmsError libraryError = MEM_RWBoolean(W, true, 0, EXP_CANDY_MEM.MemType, EXP_CANDY_MEM.Address, EXP_CANDY_MEM.SubAddress, 5, ref value);
- if (libraryError.IsError())
- return libraryError;
- else
- {
- //Leggo il dato
- libraryError = PLC_RExpiredCandy(ref newVal);
- if (libraryError.IsError())
- return libraryError;
+ // If loop timeout goes in timeout
+ if (!ok)
+ {
+ // Reset acknowledge
+ writeValue = false;
+ libraryError = MEM_RWBoolean(W, fixEndian, 0, memType, ackByte, ackSubByte, ackBit, ref writeValue);
+ if (libraryError.IsError())
+ return libraryError;
+ }
- //Se i 2 dati coincidono ritorno OK
- if (value == newVal)
- return NO_ERROR;
- else
- return PLC_NOT_RUNNING_ERROR;
+ return libraryError;
+ }
- }
- }
+ public override CmsError PLC_WExpiredCandy(bool value)
+ {
+ bool newVal = false;
- public override CmsError PLC_RExpiredCandy(ref bool value)
- {
- CmsError libraryError = MEM_RWBoolean(R, true, 0, EXP_CANDY_MEM.MemType, EXP_CANDY_MEM.Address, EXP_CANDY_MEM.SubAddress, 5, ref value);
- if (libraryError.IsError())
- return libraryError;
- return NO_ERROR;
- }
+ //Scrivo il dato
+ CmsError libraryError = MEM_RWBoolean(W, true, 0, EXP_CANDY_MEM.MemType, EXP_CANDY_MEM.Address, EXP_CANDY_MEM.SubAddress, 5, ref value);
+ if (libraryError.IsError())
+ return libraryError;
+ else
+ {
+ //Leggo il dato
+ libraryError = PLC_RExpiredCandy(ref newVal);
+ if (libraryError.IsError())
+ return libraryError;
- public override CmsError PLC_WCandy(long value)
- {
- // Long is formed by a integer + word
- // Write Word
- ushort word = (ushort)((value & 0xFFFF));
- CmsError libraryError = MEM_RWWord(W, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress, ref word);
- if (libraryError.IsError())
- return libraryError;
+ //Se i 2 dati coincidono ritorno OK
+ if (value == newVal)
+ return NO_ERROR;
+ else
+ return PLC_NOT_RUNNING_ERROR;
- int integer = (int)((value & 0xFFFFFFFF0000) >> 16);
- // Write Integer (+1 is used because osai uses word)
- libraryError = MEM_RWInteger(W, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress + 2, ref integer);
- if (libraryError.IsError())
- return libraryError;
+ }
+ }
- // Rieggo il dato
- long newVal = 0;
- libraryError = PLC_RCandy(ref newVal);
- if (libraryError.IsError())
- return libraryError;
+ public override CmsError PLC_RExpiredCandy(ref bool value)
+ {
+ CmsError libraryError = MEM_RWBoolean(R, true, 0, EXP_CANDY_MEM.MemType, EXP_CANDY_MEM.Address, EXP_CANDY_MEM.SubAddress, 5, ref value);
+ if (libraryError.IsError())
+ return libraryError;
+ return NO_ERROR;
+ }
- // Se i 2 dati coincidono ritorno OK
- if (value == newVal)
- return NO_ERROR;
- else
- return PLC_NOT_RUNNING_ERROR;
- }
+ public override CmsError PLC_WCandy(long value)
+ {
+ // Long is formed by a integer + word
+ // Write Word
+ ushort word = (ushort)((value & 0xFFFF));
+ CmsError libraryError = MEM_RWWord(W, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress, ref word);
+ if (libraryError.IsError())
+ return libraryError;
- public override CmsError PLC_RCandy(ref long value)
- {
- // Long is formed by a integer + word
- // Read word
- ushort word = 0;
- CmsError libraryError = MEM_RWWord(R, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress, ref word);
- if (libraryError.IsError())
- return libraryError;
+ int integer = (int)((value & 0xFFFFFFFF0000) >> 16);
+ // Write Integer (+1 is used because osai uses word)
+ libraryError = MEM_RWInteger(W, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress + 2, ref integer);
+ if (libraryError.IsError())
+ return libraryError;
- // Read first int
- uint firtInt = 0;
- libraryError = MEM_RWDWord(R, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress + 2, ref firtInt);
- if (libraryError.IsError())
- return libraryError;
+ // Rieggo il dato
+ long newVal = 0;
+ libraryError = PLC_RCandy(ref newVal);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Se i 2 dati coincidono ritorno OK
+ if (value == newVal)
+ return NO_ERROR;
+ else
+ return PLC_NOT_RUNNING_ERROR;
+ }
+
+ public override CmsError PLC_RCandy(ref long value)
+ {
+ // Long is formed by a integer + word
+ // Read word
+ ushort word = 0;
+ CmsError libraryError = MEM_RWWord(R, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress, ref word);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // Read first int
+ uint firtInt = 0;
+ libraryError = MEM_RWDWord(R, 0, CANDY_MEM.MemType, CANDY_MEM.Address, CANDY_MEM.SubAddress + 2, ref firtInt);
+ if (libraryError.IsError())
+ return libraryError;
- // Build Long value
- value = ((long)firtInt << 16) + word;
+ // Build Long value
+ value = ((long)firtInt << 16) + word;
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- public override CmsError PLC_RActiveClient(ref int clientId)
- {
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
+ public override CmsError PLC_RActiveClient(ref int clientId)
+ {
+ CmsError libraryError = CheckConnection();
+ if (libraryError.IsError())
+ return libraryError;
- byte readValues = 0;
- libraryError = MEM_RWByte(R, true, 0, ACTIVE_CLIENT.MemType, ACTIVE_CLIENT.Address, ACTIVE_CLIENT.SubAddress, 0, ref readValues);
- if (libraryError.IsError())
- return libraryError;
+ byte readValues = 0;
+ libraryError = MEM_RWByte(R, true, 0, ACTIVE_CLIENT.MemType, ACTIVE_CLIENT.Address, ACTIVE_CLIENT.SubAddress, 0, ref readValues);
+ if (libraryError.IsError())
+ return libraryError;
- // Convert integer array into bit array
- bool[] statusBits = ByteToBits(readValues);
- // check which bit is set
- for (int i = 0; i < 8; i++)
- {
- if (statusBits[i])
- clientId = i + 1;
- }
+ // Convert integer array into bit array
+ bool[] statusBits = ByteToBits(readValues);
+ // check which bit is set
+ for (int i = 0; i < 8; i++)
+ {
+ if (statusBits[i])
+ clientId = i + 1;
+ }
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- public override CmsError PLC_RToolMovement(ref MovementBetweenMagazinesModel toolMovement)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
+ public override CmsError PLC_RToolMovement(ref MovementBetweenMagazinesModel toolMovement)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
- public override CmsError PLC_WTerminateMovementProcedure(MOVEMENT_RESPONSE resp)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
+ public override CmsError PLC_WTerminateMovementProcedure(MOVEMENT_RESPONSE resp)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
- #endregion PLC High-level data
+ #endregion PLC High-level data
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
+ ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
- #region PROCESS (PATH) High-level data
+ #region PROCESS (PATH) High-level data
- // Get the process Mode
- public override CmsError PROC_RMode(ushort ProcNumber, ref PROC_MODE Mode)
- {
- //Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
+ // Get the process Mode
+ public override CmsError PROC_RMode(ushort ProcNumber, ref PROC_MODE Mode)
+ {
+ //Check if the NC is Connected
+ CmsError libraryError = CheckConnection();
+ if (libraryError.IsError())
+ return libraryError;
- // FIXME TODO - fare guardando mappatura memoria stsato processo
+ // FIXME TODO - fare guardando mappatura memoria stsato processo
#if false
// Try to get information
@@ -1656,19 +1656,19 @@ namespace CMS_CORE_Library.S7Net
}
#endif
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- // Get the process status
- public override CmsError PROC_RStatus(ushort ProcNumber, ref PROC_STATUS Status)
- {
- // Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
+ // Get the process status
+ public override CmsError PROC_RStatus(ushort ProcNumber, ref PROC_STATUS Status)
+ {
+ // Check if the NC is Connected
+ CmsError libraryError = CheckConnection();
+ if (libraryError.IsError())
+ return libraryError;
- // FIXME TODO - fare guardando mappatura variabili status
+ // FIXME TODO - fare guardando mappatura variabili status
#if false
// Try to get information
try
@@ -1689,25 +1689,25 @@ namespace CMS_CORE_Library.S7Net
}
#endif
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- // Get PP Lines
- public override CmsError PROC_RPPLines(ushort ProcNumber, ref List Lines)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
+ // Get PP Lines
+ public override CmsError PROC_RPPLines(ushort ProcNumber, ref List Lines)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
- // Get PP Name
- public override CmsError PROC_RSelectedPPName(ushort ProcNumber, ref string Name)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
+ // Get PP Name
+ public override CmsError PROC_RSelectedPPName(ushort ProcNumber, ref string Name)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+ }
- // Get the process Active Alarms
- public override CmsError PROC_RActiveAlarms(ushort procNumber, ref List alarms)
- {
- // FIXME TODO - fare guardando bitmap allarmi attivi
+ // Get the process Active Alarms
+ public override CmsError PROC_RActiveAlarms(ushort procNumber, ref List alarms)
+ {
+ // FIXME TODO - fare guardando bitmap allarmi attivi
#if false
alarms = SiemensAlarms
.Where(x => x.Id >= IDMinChannel && x.Id <= IDMaxChannel && x.Parameters[0].Equals(procNumber.ToString()))
@@ -1726,14 +1726,14 @@ namespace CMS_CORE_Library.S7Net
.ToList();
#endif
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- // Get process part program data
- public override CmsError PROC_RStatusAndData(ushort procNumber, ref ProcessDataModel processData)
- {
- processData.Id = procNumber;
- CmsError libraryError = NO_ERROR;
+ // Get process part program data
+ public override CmsError PROC_RStatusAndData(ushort procNumber, ref ProcessDataModel processData)
+ {
+ processData.Id = procNumber;
+ CmsError libraryError = NO_ERROR;
#if false
// Read part program name
libraryError = PROC_RSelectedPPName(procNumber, ref processData.PartProgramName);
@@ -1741,111 +1741,111 @@ namespace CMS_CORE_Library.S7Net
return libraryError;
#endif
- // FIXME TODO --> forzato tutto a true... eventualmente rivedere in futuro x processo caricatore vs processo principale
- bool forceValues = true;
+ // FIXME TODO --> forzato tutto a true... eventualmente rivedere in futuro x processo caricatore vs processo principale
+ bool forceValues = true;
- if (forceValues)
- {
- processData.Visible = true;
- processData.Type = "WORK";
- processData.IsSelected = true;
- processData.IsInAlarm = false;
- processData.CanLoadProgram = true;
- processData.Status = "RUN";
- processData.Reps = 0;
- }
- else
- {
- int readValue = 0;
+ if (forceValues)
+ {
+ processData.Visible = true;
+ processData.Type = "WORK";
+ processData.IsSelected = true;
+ processData.IsInAlarm = false;
+ processData.CanLoadProgram = true;
+ processData.Status = "RUN";
+ processData.Reps = 0;
+ }
+ else
+ {
+ int readValue = 0;
- // Read processes status from memory
- libraryError = MEM_RWInteger(R, 0, PROCESS_STATUS.MemType, PROCESS_STATUS.Address, PROCESS_STATUS.SubAddress + ((procNumber - 1) * 2), ref readValue);
- if (libraryError.IsError())
- return libraryError;
+ // Read processes status from memory
+ libraryError = MEM_RWInteger(R, 0, PROCESS_STATUS.MemType, PROCESS_STATUS.Address, PROCESS_STATUS.SubAddress + ((procNumber - 1) * 2), ref readValue);
+ if (libraryError.IsError())
+ return libraryError;
- byte[] bytes = BitConverter.GetBytes(readValue);
+ byte[] bytes = BitConverter.GetBytes(readValue);
- // Convert Byte into true/false array
- BitArray bits = new BitArray(new byte[] { bytes[0] }); // 1st byte -> 0 : Proccess type (AUX-WORK), 1: Process in alarm status, 2: Run, 3: Hold, 4: Read, 5: PartProgramVisible
+ // Convert Byte into true/false array
+ BitArray bits = new BitArray(new byte[] { bytes[0] }); // 1st byte -> 0 : Proccess type (AUX-WORK), 1: Process in alarm status, 2: Run, 3: Hold, 4: Read, 5: PartProgramVisible
- // Get part program info visibility
- processData.Visible = bits[0];
+ // Get part program info visibility
+ processData.Visible = bits[0];
- // Populate response structure
- processData.Type = bits[1] ? "WORK" : "AUX";
- processData.IsSelected = bits[2];
- processData.IsInAlarm = bits[3];
- processData.CanLoadProgram = bits[4];
+ // Populate response structure
+ processData.Type = bits[1] ? "WORK" : "AUX";
+ processData.IsSelected = bits[2];
+ processData.IsInAlarm = bits[3];
+ processData.CanLoadProgram = bits[4];
- // Choose process status
- if (bytes[1] == 1)
- processData.Status = "HOLD";
- else
- {
- if (bytes[1] == 2)
- processData.Status = "RUN";
- else
- processData.Status = "READY";
+ // Choose process status
+ if (bytes[1] == 1)
+ processData.Status = "HOLD";
+ else
+ {
+ if (bytes[1] == 2)
+ processData.Status = "RUN";
+ else
+ processData.Status = "READY";
+ }
+
+ // Get Reps from 3nd-4th byte
+ processData.Reps = BitConverter.ToUInt16(bytes, 2);
+ }
+
+ return NO_ERROR;
}
- // Get Reps from 3nd-4th byte
- processData.Reps = BitConverter.ToUInt16(bytes, 2);
- }
+ public override CmsError PROC_RSelectedProcess(ref ushort procNumber)
+ {
+ if (SelectedProcess == 0)
+ return SELECTED_PROCESS_ERROR;
- return NO_ERROR;
- }
+ procNumber = SelectedProcess;
+ //CmsError libraryError;
+ //bool readValue = false;
- public override CmsError PROC_RSelectedProcess(ref ushort procNumber)
- {
- if (SelectedProcess == 0)
- return SELECTED_PROCESS_ERROR;
+ //for (int i = 0; i < PROCESS_NUMBER; i++)
+ //{
+ // // Calculate bit address = ProcessBase + processId * 2
+ // int memoryAddress = SELECTED_PROCESS.SubAddress + i * (2);
+ // // Read memory from plc
+ // libraryError = MEM_RWBoolean(R, 0, SELECTED_PROCESS.MemType, SELECTED_PROCESS.Address, memoryAddress, 2, ref readValue);
+ // if (libraryError.IsError())
+ // return libraryError;
- procNumber = SelectedProcess;
- //CmsError libraryError;
- //bool readValue = false;
+ // if (readValue)
+ // {
+ // procNumber = (ushort)(i + 1);
+ // return NO_ERROR;
+ // }
+ //}
- //for (int i = 0; i < PROCESS_NUMBER; i++)
- //{
- // // Calculate bit address = ProcessBase + processId * 2
- // int memoryAddress = SELECTED_PROCESS.SubAddress + i * (2);
- // // Read memory from plc
- // libraryError = MEM_RWBoolean(R, 0, SELECTED_PROCESS.MemType, SELECTED_PROCESS.Address, memoryAddress, 2, ref readValue);
- // if (libraryError.IsError())
- // return libraryError;
+ return NO_ERROR;
+ }
- // if (readValue)
- // {
- // procNumber = (ushort)(i + 1);
- // return NO_ERROR;
- // }
- //}
+ public override CmsError PROC_WSelectProcess(ushort procNumber)
+ {
+ CmsError libraryError;
+ byte processNum = (byte)procNumber;
- return NO_ERROR;
- }
+ // Check parameter
+ if (processNum > MAX_PROCESS_NUMBER)
+ return INCORRECT_PARAMETERS_ERROR;
- public override CmsError PROC_WSelectProcess(ushort procNumber)
- {
- CmsError libraryError;
- byte processNum = (byte)procNumber;
+ // Write process number
+ libraryError = MEM_RWByte(W, true, 0, SELECT_PROCESS.MemType, SELECT_PROCESS.Address, SELECT_PROCESS.SubAddress, 0, ref processNum);
+ if (libraryError.IsError())
+ return libraryError;
- // Check parameter
- if (processNum > MAX_PROCESS_NUMBER)
- return INCORRECT_PARAMETERS_ERROR;
+ return NO_ERROR;
+ }
- // Write process number
- libraryError = MEM_RWByte(W, true, 0, SELECT_PROCESS.MemType, SELECT_PROCESS.Address, SELECT_PROCESS.SubAddress, 0, ref processNum);
- if (libraryError.IsError())
- return libraryError;
+ public override CmsError PROC_RSelectedProcessData(int processId, ref SelectedProcessData processData)
+ {
+ if (processId <= 0)
+ return PROC_NOT_FOUND_ERROR;
- return NO_ERROR;
- }
-
- public override CmsError PROC_RSelectedProcessData(int processId, ref SelectedProcessData processData)
- {
- if (processId <= 0)
- return PROC_NOT_FOUND_ERROR;
-
- // FIXME TODO - ha senso?
+ // FIXME TODO - ha senso?
#if false
try
{
@@ -1966,174 +1966,190 @@ namespace CMS_CORE_Library.S7Net
}
#endif
- return NO_ERROR;
- }
-
- private CmsError PROC_ReadActiveLine(uint processId, ref string line)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
-
- }
-
- #endregion PROCESS (PATH) High-level data
-
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
-
- #region THERMO high level data
-
-
- ///
- /// Read Status/command words
- ///
- ///
- public override CmsError PLC_RStatusCommand(ref List statusCmd)
- {
- CmsError libraryError = NO_ERROR;
- // leggo intera area DWORD e di conseguenza processo...
- statusCmd = new List();
- libraryError = MEM_RWWordList(R, 0, STATUS_CMD_DATA.MemType, STATUS_CMD_DATA.Address, STATUS_CMD_DATA.SubAddress, STATUS_CMD_DATA.Size, ref statusCmd);
- if (libraryError.IsError())
- return libraryError;
-
- return libraryError;
- }
- ///
- /// Process conf request
- ///
- ///
- public override CmsError PLC_WAckConfRiskRequest()
- {
- CmsError libraryError = NO_ERROR;
-
- // Call ack for config request RISK
- libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 8);
- if (libraryError.IsError())
- return libraryError;
-
- return libraryError;
- }
- ///
- /// Process conf request
- ///
- ///
- public override CmsError PLC_WAckConfRecipeRequest()
- {
- CmsError libraryError = NO_ERROR;
-
- // Call ack for config request RECIPE
- libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 9);
- if (libraryError.IsError())
- return libraryError;
-
- return libraryError;
- }
- ///
- /// Process production info update
- ///
- ///
- public override CmsError PLC_WAckProdUpdate()
- {
- CmsError libraryError = NO_ERROR;
-
- // Call ack for prod update
- libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 4);
- if (libraryError.IsError())
- return libraryError;
-
- return libraryError;
- }
- ///
- /// Process start prod ack
- ///
- ///
- public override CmsError PLC_WAckPzProdStart()
- {
- CmsError libraryError = NO_ERROR;
-
- // Call ack for prod update
- libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 11);
- if (libraryError.IsError())
- return libraryError;
-
- return libraryError;
- }
- ///
- /// Process end prod ack
- ///
- ///
- public override CmsError PLC_WAckPzProdEnd()
- {
- CmsError libraryError = NO_ERROR;
-
- // Call ack for prod update
- libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 12);
- if (libraryError.IsError())
- return libraryError;
-
- return libraryError;
- }
-
- ///
- /// Get current Axis RT data
- ///
- ///
- ///
- public override CmsError PLC_RAxisRTList(ref Dictionary currAxisRT)
- {
- CmsError libraryError = NO_ERROR;
- List currMem = new List();
- int packSize = 12;
-
- // leggo da PLC a array di byte di appoggio...
- libraryError = MEM_RWByteList(R, 0, AXES_RTDATA.MemType, AXES_RTDATA.Address, AXES_RTDATA.SubAddress, 0, AXES_RTDATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
- // controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < AXES_RTDATA.Size / packSize; i++)
- {
- ThermoModels.AxisRT currData = new ThermoModels.AxisRT(i + 1, memArray.Skip(i * packSize).Take(packSize).ToArray());
- // solo se ID > 0...
- if (currData.Id > 0)
- {
- // update oggetto thermoParamList...
- if (currAxisRT.ContainsKey(currData.Id))
- {
- try
- {
- currAxisRT[currData.Id].Position = currData.Position;
- currAxisRT[currData.Id].Speed = currData.Speed;
- currAxisRT[currData.Id].Load = currData.Load;
- }
- catch
- { }
- }
- else
- {
- try
- {
- currAxisRT.Add(currData.Id, currData);
- }
- catch
- { }
- }
- }
+ return NO_ERROR;
}
- }
- return libraryError;
- }
- ///
- /// Get current Axis Info data
- ///
- ///
- ///
- public override CmsError PLC_RAxisInfoList(ref Dictionary currAxisInfo)
- {
- CmsError libraryError = NO_ERROR;
+
+ private CmsError PROC_ReadActiveLine(uint processId, ref string line)
+ {
+ return FUNCTION_NOT_ALLOWED_ERROR;
+
+ }
+
+ #endregion PROCESS (PATH) High-level data
+
+ ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
+
+ #region THERMO high level data
+
+
+ ///
+ /// Read Status/command words
+ ///
+ ///
+ public override CmsError PLC_RStatusCommand(ref List statusCmd)
+ {
+ CmsError libraryError = NO_ERROR;
+ // leggo intera area DWORD e di conseguenza processo...
+ statusCmd = new List();
+ libraryError = MEM_RWWordList(R, 0, STATUS_CMD_DATA.MemType, STATUS_CMD_DATA.Address, STATUS_CMD_DATA.SubAddress, STATUS_CMD_DATA.Size, ref statusCmd);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+ ///
+ /// Process conf request
+ ///
+ ///
+ public override CmsError PLC_WAckConfRiskRequest()
+ {
+ CmsError libraryError = NO_ERROR;
+
+ // Call ack for config request RISK
+ libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 8);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+ ///
+ /// Process conf request
+ ///
+ ///
+ public override CmsError PLC_WAckConfRecipeRequest()
+ {
+ CmsError libraryError = NO_ERROR;
+
+ // Call ack for config request RECIPE
+ libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 9);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+ ///
+ /// Process production info update
+ ///
+ ///
+ public override CmsError PLC_WAckProdUpdate()
+ {
+ CmsError libraryError = NO_ERROR;
+
+ // Call ack for prod update
+ libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 4);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+ ///
+ /// Process start prod ack
+ ///
+ ///
+ public override CmsError PLC_WAckPzProdStart()
+ {
+ CmsError libraryError = NO_ERROR;
+
+ // Call ack for prod update
+ libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 11);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+ ///
+ /// Process end prod ack
+ ///
+ ///
+ public override CmsError PLC_WAckPzProdEnd()
+ {
+ CmsError libraryError = NO_ERROR;
+
+ // Call ack for prod update
+ libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 12);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+
+ ///
+ /// Process setpointHMI invalidated with ack
+ ///
+ ///
+ public override CmsError PLC_WAckSetpointInvalidated()
+ {
+ CmsError libraryError = NO_ERROR;
+
+ // Call ack for prod update
+ libraryError = PLC_WAck(true, REQ_CONF_ACK, REQ_CONF_STROBE, 15);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return libraryError;
+ }
+
+ ///
+ /// Get current Axis RT data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RAxisRTList(ref Dictionary currAxisRT)
+ {
+ CmsError libraryError = NO_ERROR;
+ List currMem = new List();
+ int packSize = 12;
+
+ // leggo da PLC a array di byte di appoggio...
+ libraryError = MEM_RWByteList(R, 0, AXES_RTDATA.MemType, AXES_RTDATA.Address, AXES_RTDATA.SubAddress, 0, AXES_RTDATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < AXES_RTDATA.Size / packSize; i++)
+ {
+ ThermoModels.AxisRT currData = new ThermoModels.AxisRT(i + 1, memArray.Skip(i * packSize).Take(packSize).ToArray());
+ // solo se ID > 0...
+ if (currData.Id > 0)
+ {
+ // update oggetto thermoParamList...
+ if (currAxisRT.ContainsKey(currData.Id))
+ {
+ try
+ {
+ currAxisRT[currData.Id].Position = currData.Position;
+ currAxisRT[currData.Id].Speed = currData.Speed;
+ currAxisRT[currData.Id].Load = currData.Load;
+ }
+ catch
+ { }
+ }
+ else
+ {
+ try
+ {
+ currAxisRT.Add(currData.Id, currData);
+ }
+ catch
+ { }
+ }
+ }
+ }
+ }
+ return libraryError;
+ }
+ ///
+ /// Get current Axis Info data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RAxisInfoList(ref Dictionary currAxisInfo)
+ {
+ CmsError libraryError = NO_ERROR;
#if false
CmsError libraryError = NO_ERROR;
List currMem = new List();
@@ -2181,455 +2197,481 @@ namespace CMS_CORE_Library.S7Net
}
}
#endif
- return libraryError;
- }
- ///
- /// read current recipe parameter list
- ///
- /// updates only RT parameters (false = update all)
- ///
- ///
- public override CmsError PLC_RRecipeParamList(bool onlyRT, ref Dictionary currParamList)
- {
- CmsError currError = NO_ERROR;
- // refresh dati veloci / RT
- refreshMemRecipeParameterRT();
- // se richiesto NON SOLO RT faccio refresh anche dati "lenti"
- if (!onlyRT)
- {
- refreshMemRecipeParameter();
- }
-
- // copio lista act in output...
- currParamList = ThermoParamList;
- return currError;
- }
- ///
- /// Write recipe updated MULTIPLE parameter
- ///
- /// Oggetto parametri da aggiornare (from HMI)
- /// num max parametri da scrivere singolarmente, default = 10
- /// delay in scriottura multi parametri singoli, default = 20ms
- ///
- public override CmsError PLC_WRecipeParameters(Dictionary newParameters, int nMaxParamWrite = 10, int delayParamWrite = 20)
- {
- // init variabili accessorie
- CmsError libraryError = NO_ERROR;
- List currMem = new List();
- int memIndex = 0;
- int packSize = 20;
-
-
- // 2020.09.03: ricevuto da chiamata, dovrebbe essere 5 parametri x scrivere tutto (era 30 prima di 2008.08.07)
- bool writeSingle = newParameters.Count < nMaxParamWrite;
-
- // leggo da PLC a array di byte di appoggio...
- libraryError = MEM_RWByteList(R, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress, 0, PARAMETER_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
- PlcParam currParam;
- List newMem = new List();
- // controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto in array di byte...
- byte[] memArray = currMem.ToArray();
- // ciclo x ogni parametro x aggiornare il valore...
- foreach (var item in newParameters)
- {
- memIndex = (item.Key - 1) * packSize;
- // recupero oggetto parametri
- currParam = new PlcParam(memArray.Skip(memIndex).Take(packSize).ToArray());
- if (currParam.Id > 0)
- {
- // se servisse resetto...
- if (currParam.Id != (short)item.Key)
- currParam.Id = (short)item.Key;
- currParam.SetpointHMI = (int)item.Value;
- // scrivo 1:1 se pochi dati SOLO i singoli valori HMI
- if (writeSingle)
- {
- newMem = S7.Net.Types.DInt.ToByteArray(currParam.SetpointHMI).ToList();// currParam.convertToByte().ToList();
- libraryError = MEM_RWByteList(W, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress + packSize * (currParam.Id - 1) + 2, 0, 4, ref newMem);
- if (libraryError.IsError())
- return libraryError;
- // attendo x sicurezza...
- Thread.Sleep(delayParamWrite);
- }
- else
- {
- // accodo su memoria generale
- Buffer.BlockCopy(currParam.convertToByte(), 0, memArray, memIndex, packSize);
- }
- }
- }
-
- // converto nuova memoria
- newMem = memArray.ToList();
- memIndex = 0;
- if (!writeSingle)
- {
- // SCRIVO in blocco!
- libraryError = MEM_RWByteList(W, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress, 0, PARAMETER_DATA.Size, ref newMem);
- if (libraryError.IsError())
return libraryError;
}
- }
-
- return NO_ERROR;
- }
- ///
- /// Confirm/Cancel recipe modifications
- ///
- /// true: HMI --> PLC, false: PLC --> HMI
- ///
- public override CmsError PLC_WRecipeEdit(bool confirmUpdate)
- {
- // se update --> scrivo strobe comando update...
- if (confirmUpdate)
- {
- // Call confirm update
- CmsError libraryError = PLC_WStrobe(true, PARAMETER_EDIT_ACK, PARAMETER_EDIT_STROBE, 2);
- if (libraryError.IsError())
- return libraryError;
- }
- // altrimenti mando strobe comando cancel...
- else
- {
- // Call cancel update
- CmsError libraryError = PLC_WStrobe(true, PARAMETER_EDIT_ACK, PARAMETER_EDIT_STROBE, 3);
- if (libraryError.IsError())
- return libraryError;
- }
-
- return NO_ERROR;
- }
-
- ///
- /// Get current Modules Block list
- ///
- /// updates only RT parameters (false = update all)
- ///
- ///
- public override CmsError PLC_RModulesBlockList(bool onlyRT, ref Dictionary currModulesBlockList)
- {
- // se richiesto NON SOLO RT faccio refresh anche dati "lenti"
- if (!onlyRT)
- {
- refreshMemModBlockParameter();
- }
- // refresh dati veloci / RT
- refreshMemModBlockParameterRT();
-
- // copio lista act in output...
- currModulesBlockList = ThermoModuleList;
- return NO_ERROR;
- }
- ///
- /// Get current Warmers Channels list
- ///
- ///
- ///
- public override CmsError PLC_RWarmerChannelList(ref Dictionary currWarmerChannelList)
- {
- // refresh stato canale
- refreshRiscStatus();
- // refresh % attuale
- refreshRiscPerc();
- // refresh setpoint PLC
- refreshRiscActCurr();
- // refresh setpoint HMI
- refreshRiscSetpointHMI();
- // refresh setpoint PLC
- refreshRiscSetpointPLC();
- // refresh setpoint termocamera ???
- refreshRiscSetpointTermoCam();
-
- // copio lista act in output
- currWarmerChannelList = ThermoWarmChannels;
-
- return NO_ERROR;
- }
-
- ///
- /// Get gauge data
- ///
- ///
- ///
- public override CmsError PLC_RGaugeData(ref ThermoModels.LiveProdDataModel gaugeData)
- {
- List Values = new List();
- CmsError libraryError = MEM_RWIntegerList(R, 1, MACHINE_GAUGE_DATA.MemType, MACHINE_GAUGE_DATA.Address, MACHINE_GAUGE_DATA.SubAddress, MACHINE_GAUGE_DATA.Size / 4, ref Values);
-
- if (libraryError.IsError())
- return libraryError;
-
- gaugeData = new ThermoModels.LiveProdDataModel()
- {
- TimeAdv = Convert.ToUInt32(Values[0]),
- Power = Values[1],
- Vacuum = Values[2],
- Air = Values[3],
- };
-
- return NO_ERROR;
- }
- ///
- /// Get current Production Info data
- ///
- ///
- ///
- public override CmsError PLC_RProdInfo(ref ThermoModels.ProdInfoModel currProdInfo)
- {
- List currMem = new List();
- CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
- // converto!
- currProdInfo = new ThermoModels.ProdInfoModel()
- {
- NumTarget = S7.Net.Types.Int.FromByteArray(currMem.Skip(0).Take(2).ToArray())
- ,NumDone = S7.Net.Types.Int.FromByteArray(currMem.Skip(2).Take(2).ToArray())
- // cicli preriscaldo? FIXME TODO
- ,TimeWarm = S7.Net.Types.DInt.FromByteArray(currMem.Skip(6).Take(4).ToArray())
- ,TimeVent = S7.Net.Types.DInt.FromByteArray(currMem.Skip(10).Take(4).ToArray())
- ,TimeVacuum = S7.Net.Types.DInt.FromByteArray(currMem.Skip(14).Take(4).ToArray())
- ,TimeCycleGross = S7.Net.Types.DInt.FromByteArray(currMem.Skip(18).Take(4).ToArray())
- ,TimeCycleNet = S7.Net.Types.DInt.FromByteArray(currMem.Skip(22).Take(4).ToArray())
- ,MaterialTempEndWarm = S7.Net.Types.Double.FromByteArray(currMem.Skip(26).Take(4).ToArray())
- ,MaterialTempEndVent = S7.Net.Types.Double.FromByteArray(currMem.Skip(30).Take(4).ToArray())
- ,MoldTemp = S7.Net.Types.Double.FromByteArray(currMem.Skip(34).Take(4).ToArray())
- ,VacuumReadVal = S7.Net.Types.Double.FromByteArray(currMem.Skip(38).Take(4).ToArray())
- ,MouldEnergyOUT = S7.Net.Types.Double.FromByteArray(currMem.Skip(42).Take(4).ToArray())
- ,MouldEnergyIN = S7.Net.Types.Double.FromByteArray(currMem.Skip(46).Take(4).ToArray())
- //,NumPreHot = S7.Net.Types.Int.FromByteArray(currMem.Skip(50).Take(2).ToArray())
- };
-
- return NO_ERROR;
- }
- ///
- /// Set ProdInfo data
- ///
- /// Qty requested (target)
- /// Reset counter (actual counter)
- /// Number of pre-warm cycle requested
- ///
- public override CmsError PLC_WProdInfo(short numTarget, bool doReset, short preWarmCycle)
- {
- List currMem = new List();
- CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
- // converto!
- var currProdInfo = new ThermoModels.ProdInfoModel()
- {
- NumTarget = S7.Net.Types.Int.FromByteArray(currMem.Skip(0).Take(2).ToArray())
- ,NumDone = S7.Net.Types.Int.FromByteArray(currMem.Skip(2).Take(2).ToArray())
- ,PreWarmCycle = S7.Net.Types.Int.FromByteArray(currMem.Skip(4).Take(2).ToArray())
- ,TimeWarm = S7.Net.Types.DInt.FromByteArray(currMem.Skip(6).Take(4).ToArray())
- ,TimeVent = S7.Net.Types.DInt.FromByteArray(currMem.Skip(10).Take(4).ToArray())
- ,TimeVacuum = S7.Net.Types.DInt.FromByteArray(currMem.Skip(14).Take(4).ToArray())
- ,TimeCycleGross = S7.Net.Types.DInt.FromByteArray(currMem.Skip(18).Take(4).ToArray())
- ,TimeCycleNet = S7.Net.Types.DInt.FromByteArray(currMem.Skip(22).Take(4).ToArray())
- ,MaterialTempEndWarm = S7.Net.Types.Double.FromByteArray(currMem.Skip(26).Take(4).ToArray())
- ,MaterialTempEndVent = S7.Net.Types.Double.FromByteArray(currMem.Skip(30).Take(4).ToArray())
- ,MoldTemp = S7.Net.Types.Double.FromByteArray(currMem.Skip(34).Take(4).ToArray())
- ,VacuumReadVal = S7.Net.Types.Double.FromByteArray(currMem.Skip(38).Take(4).ToArray())
- ,MouldEnergyOUT = S7.Net.Types.Double.FromByteArray(currMem.Skip(42).Take(4).ToArray())
- ,MouldEnergyIN = S7.Net.Types.Double.FromByteArray(currMem.Skip(46).Take(4).ToArray())
- ,NumPreHot = S7.Net.Types.Int.FromByteArray(currMem.Skip(50).Take(2).ToArray())
- };
-
- // aggiorno...
- currProdInfo.NumTarget = numTarget;
- currProdInfo.PreWarmCycle = preWarmCycle;
- // converto a byte...
- List newMem = currProdInfo.convertToByte().ToList();
- // riscrivo!!!!
- libraryError = MEM_RWByteList(W, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref newMem);
- if (libraryError.IsError())
- return libraryError;
-
- if (doReset)
- {
- // send strobe of NEW WorkOrder / reset QTY
- libraryError = PLC_WStrobe(true, PROD_ACK, PROD_STROBE, 10);
- if (libraryError.IsError())
- return libraryError;
- }
-
- return NO_ERROR;
- }
- ///
- /// Get current Production Cycle data
- ///
- ///
- ///
- public override CmsError PLC_RProdCycle(ref ThermoModels.ProdCycleModel currProdCycle)
- {
- List currMem = new List();
- CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_CYCLE.MemType, PROCESS_PROD_CYCLE.Address, PROCESS_PROD_CYCLE.SubAddress, 0, PROCESS_PROD_CYCLE.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
- // converto!
- currProdCycle = new ThermoModels.ProdCycleModel()
- {
- Status = S7.Net.Types.Word.FromByteArray(currMem.Skip(0).Take(2).ToArray()),
- MessageId = S7.Net.Types.Word.FromByteArray(currMem.Skip(2).Take(2).ToArray()),
- Mode = S7.Net.Types.Byte.FromByteArray(currMem.Skip(4).Take(1).ToArray()),
- Submode = S7.Net.Types.Byte.FromByteArray(currMem.Skip(5).Take(1).ToArray()),
- TimeAdv = S7.Net.Types.DWord.FromByteArray(currMem.Skip(6).Take(4).ToArray())
- };
-
- return NO_ERROR;
- }
-
- ///
- /// Refresh recipE parameters RT
- ///
- protected CmsError refreshMemRecipeParameterRT()
- {
- CmsError libraryError = NO_ERROR;
- List currMem = new List();
- int packSize = 8;
-
- // leggo da PLC a array di byte di appoggio...
- libraryError = MEM_RWByteList(R, 0, PARAMETER_RT_DATA.MemType, PARAMETER_RT_DATA.Address, PARAMETER_RT_DATA.SubAddress, 0, PARAMETER_RT_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
- // controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < PARAMETER_RT_DATA.Size / packSize; i++)
+ ///
+ /// read current recipe parameter list
+ ///
+ /// updates only RT parameters (false = update all)
+ ///
+ ///
+ public override CmsError PLC_RRecipeParamList(bool onlyRT, ref Dictionary currParamList)
{
- PlcParamRT currParam = new PlcParamRT(memArray.Skip(i * packSize).Take(packSize).ToArray());
- // solo se ID > 0...
- if (currParam.Id > 0)
- {
- // update oggetto thermoParamList...
- if (ThermoParamList.ContainsKey(currParam.Id))
+ CmsError currError = NO_ERROR;
+ // refresh dati veloci / RT
+ refreshMemRecipeParameterRT();
+ // se richiesto NON SOLO RT faccio refresh anche dati "lenti"
+ if (!onlyRT)
{
- try
- {
- ThermoParamList[currParam.Id].Enabled = currParam.Enabled;
- ThermoParamList[currParam.Id].HasError = currParam.HasError;
- ThermoParamList[currParam.Id].Visible = currParam.Visible;
- ThermoParamList[currParam.Id].ValueAct = currParam.ValueAct;
- }
- catch
- { }
+ refreshMemRecipeParameter();
+ }
+
+ // copio lista act in output...
+ currParamList = ThermoParamList;
+ return currError;
+ }
+ ///
+ /// Write recipe updated MULTIPLE parameter
+ ///
+ /// Oggetto parametri da aggiornare (from HMI)
+ /// num max parametri da scrivere singolarmente, default = 10
+ /// delay in scriottura multi parametri singoli, default = 20ms
+ ///
+ public override CmsError PLC_WRecipeParameters(Dictionary newParameters, int nMaxParamWrite = 10, int delayParamWrite = 20)
+ {
+ // init variabili accessorie
+ CmsError libraryError = NO_ERROR;
+ List currMem = new List();
+ int memIndex = 0;
+ int packSize = 20;
+
+
+ // 2020.09.03: ricevuto da chiamata, dovrebbe essere 5 parametri x scrivere tutto (era 30 prima di 2008.08.07)
+ bool writeSingle = newParameters.Count < nMaxParamWrite;
+
+ // leggo da PLC a array di byte di appoggio...
+ libraryError = MEM_RWByteList(R, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress, 0, PARAMETER_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ PlcParam currParam;
+ List newMem = new List();
+ // controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto in array di byte...
+ byte[] memArray = currMem.ToArray();
+ // ciclo x ogni parametro x aggiornare il valore...
+ foreach (var item in newParameters)
+ {
+ memIndex = (item.Key - 1) * packSize;
+ // recupero oggetto parametri
+ currParam = new PlcParam(memArray.Skip(memIndex).Take(packSize).ToArray());
+ if (currParam.Id > 0)
+ {
+ // se servisse resetto...
+ if (currParam.Id != (short)item.Key)
+ currParam.Id = (short)item.Key;
+ currParam.SetpointHMI = (int)item.Value;
+ // scrivo 1:1 se pochi dati SOLO i singoli valori HMI
+ if (writeSingle)
+ {
+ newMem = S7.Net.Types.DInt.ToByteArray(currParam.SetpointHMI).ToList();// currParam.convertToByte().ToList();
+ libraryError = MEM_RWByteList(W, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress + packSize * (currParam.Id - 1) + 2, 0, 4, ref newMem);
+ if (libraryError.IsError())
+ return libraryError;
+ // attendo x sicurezza...
+ Thread.Sleep(delayParamWrite);
+ }
+ else
+ {
+ // accodo su memoria generale
+ Buffer.BlockCopy(currParam.convertToByte(), 0, memArray, memIndex, packSize);
+ }
+ }
+ }
+
+ // converto nuova memoria
+ newMem = memArray.ToList();
+ memIndex = 0;
+ if (!writeSingle)
+ {
+ // SCRIVO in blocco!
+ libraryError = MEM_RWByteList(W, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress, 0, PARAMETER_DATA.Size, ref newMem);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+ }
+
+ return NO_ERROR;
+ }
+ ///
+ /// Confirm/Cancel recipe modifications
+ ///
+ /// true: HMI --> PLC, false: PLC --> HMI
+ ///
+ public override CmsError PLC_WRecipeEdit(bool confirmUpdate)
+ {
+ // se update --> scrivo strobe comando update...
+ if (confirmUpdate)
+ {
+ // Call confirm update
+ CmsError libraryError = PLC_WStrobe(true, PARAMETER_EDIT_ACK, PARAMETER_EDIT_STROBE, 2);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+ // altrimenti mando strobe comando cancel...
+ else
+ {
+ // Call cancel update
+ CmsError libraryError = PLC_WStrobe(true, PARAMETER_EDIT_ACK, PARAMETER_EDIT_STROBE, 3);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Get current Modules Block list
+ ///
+ /// updates only RT parameters (false = update all)
+ ///
+ ///
+ public override CmsError PLC_RModulesBlockList(bool onlyRT, ref Dictionary currModulesBlockList)
+ {
+ // se richiesto NON SOLO RT faccio refresh anche dati "lenti"
+ if (!onlyRT)
+ {
+ refreshMemModBlockParameter();
+ }
+ // refresh dati veloci / RT
+ refreshMemModBlockParameterRT();
+
+ // copio lista act in output...
+ currModulesBlockList = ThermoModuleList;
+ return NO_ERROR;
+ }
+ ///
+ /// Get current Warmers Channels list
+ ///
+ ///
+ ///
+ public override CmsError PLC_RWarmerChannelList(ref Dictionary currWarmerChannelList)
+ {
+ // refresh stato canale
+ refreshRiscStatus();
+ // refresh % attuale
+ refreshRiscPerc();
+ // refresh setpoint PLC
+ refreshRiscActCurr();
+ // refresh setpoint HMI
+ refreshRiscSetpointHMI();
+ // refresh setpoint PLC
+ refreshRiscSetpointPLC();
+ // refresh setpoint termocamera ???
+ refreshRiscSetpointTermoCam();
+
+ // copio lista act in output
+ currWarmerChannelList = ThermoWarmChannels;
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Get gauge data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RGaugeData(ref ThermoModels.LiveProdDataModel gaugeData)
+ {
+ List Values = new List();
+ CmsError libraryError = MEM_RWIntegerList(R, 1, MACHINE_GAUGE_DATA.MemType, MACHINE_GAUGE_DATA.Address, MACHINE_GAUGE_DATA.SubAddress, MACHINE_GAUGE_DATA.Size / 4, ref Values);
+
+ if (libraryError.IsError())
+ return libraryError;
+
+ gaugeData = new ThermoModels.LiveProdDataModel()
+ {
+ TimeAdv = Convert.ToUInt32(Values[0]),
+ Power = Values[1],
+ Vacuum = Values[2],
+ Air = Values[3],
+ };
+
+ return NO_ERROR;
+ }
+ ///
+ /// Get current Production Info data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RProdInfo(ref ThermoModels.ProdInfoModel currProdInfo)
+ {
+ List currMem = new List();
+ CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // converto!
+ currProdInfo = new ThermoModels.ProdInfoModel()
+ {
+ NumTarget = S7.Net.Types.Int.FromByteArray(currMem.Skip(0).Take(2).ToArray())
+ ,
+ NumDone = S7.Net.Types.Int.FromByteArray(currMem.Skip(2).Take(2).ToArray())
+ // cicli preriscaldo? FIXME TODO
+ ,
+ TimeWarm = S7.Net.Types.DInt.FromByteArray(currMem.Skip(6).Take(4).ToArray())
+ ,
+ TimeVent = S7.Net.Types.DInt.FromByteArray(currMem.Skip(10).Take(4).ToArray())
+ ,
+ TimeVacuum = S7.Net.Types.DInt.FromByteArray(currMem.Skip(14).Take(4).ToArray())
+ ,
+ TimeCycleGross = S7.Net.Types.DInt.FromByteArray(currMem.Skip(18).Take(4).ToArray())
+ ,
+ TimeCycleNet = S7.Net.Types.DInt.FromByteArray(currMem.Skip(22).Take(4).ToArray())
+ ,
+ MaterialTempEndWarm = S7.Net.Types.Double.FromByteArray(currMem.Skip(26).Take(4).ToArray())
+ ,
+ MaterialTempEndVent = S7.Net.Types.Double.FromByteArray(currMem.Skip(30).Take(4).ToArray())
+ ,
+ MoldTemp = S7.Net.Types.Double.FromByteArray(currMem.Skip(34).Take(4).ToArray())
+ ,
+ VacuumReadVal = S7.Net.Types.Double.FromByteArray(currMem.Skip(38).Take(4).ToArray())
+ ,
+ MouldEnergyOUT = S7.Net.Types.Double.FromByteArray(currMem.Skip(42).Take(4).ToArray())
+ ,
+ MouldEnergyIN = S7.Net.Types.Double.FromByteArray(currMem.Skip(46).Take(4).ToArray())
+ //,NumPreHot = S7.Net.Types.Int.FromByteArray(currMem.Skip(50).Take(2).ToArray())
+ };
+
+ return NO_ERROR;
+ }
+ ///
+ /// Set ProdInfo data
+ ///
+ /// Qty requested (target)
+ /// Reset counter (actual counter)
+ /// Number of pre-warm cycle requested
+ ///
+ public override CmsError PLC_WProdInfo(short numTarget, bool doReset, short preWarmCycle)
+ {
+ List currMem = new List();
+ CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // converto!
+ var currProdInfo = new ThermoModels.ProdInfoModel()
+ {
+ NumTarget = S7.Net.Types.Int.FromByteArray(currMem.Skip(0).Take(2).ToArray())
+ ,
+ NumDone = S7.Net.Types.Int.FromByteArray(currMem.Skip(2).Take(2).ToArray())
+ ,
+ PreWarmCycle = S7.Net.Types.Int.FromByteArray(currMem.Skip(4).Take(2).ToArray())
+ ,
+ TimeWarm = S7.Net.Types.DInt.FromByteArray(currMem.Skip(6).Take(4).ToArray())
+ ,
+ TimeVent = S7.Net.Types.DInt.FromByteArray(currMem.Skip(10).Take(4).ToArray())
+ ,
+ TimeVacuum = S7.Net.Types.DInt.FromByteArray(currMem.Skip(14).Take(4).ToArray())
+ ,
+ TimeCycleGross = S7.Net.Types.DInt.FromByteArray(currMem.Skip(18).Take(4).ToArray())
+ ,
+ TimeCycleNet = S7.Net.Types.DInt.FromByteArray(currMem.Skip(22).Take(4).ToArray())
+ ,
+ MaterialTempEndWarm = S7.Net.Types.Double.FromByteArray(currMem.Skip(26).Take(4).ToArray())
+ ,
+ MaterialTempEndVent = S7.Net.Types.Double.FromByteArray(currMem.Skip(30).Take(4).ToArray())
+ ,
+ MoldTemp = S7.Net.Types.Double.FromByteArray(currMem.Skip(34).Take(4).ToArray())
+ ,
+ VacuumReadVal = S7.Net.Types.Double.FromByteArray(currMem.Skip(38).Take(4).ToArray())
+ ,
+ MouldEnergyOUT = S7.Net.Types.Double.FromByteArray(currMem.Skip(42).Take(4).ToArray())
+ ,
+ MouldEnergyIN = S7.Net.Types.Double.FromByteArray(currMem.Skip(46).Take(4).ToArray())
+ ,
+ NumPreHot = S7.Net.Types.Int.FromByteArray(currMem.Skip(50).Take(2).ToArray())
+ };
+
+ // aggiorno...
+ currProdInfo.NumTarget = numTarget;
+ currProdInfo.PreWarmCycle = preWarmCycle;
+ // converto a byte...
+ List newMem = currProdInfo.convertToByte().ToList();
+ // riscrivo!!!!
+ libraryError = MEM_RWByteList(W, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref newMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ if (doReset)
+ {
+ // send strobe of NEW WorkOrder / reset QTY
+ libraryError = PLC_WStrobe(true, PROD_ACK, PROD_STROBE, 10);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+
+ return NO_ERROR;
+ }
+ ///
+ /// Get current Production Cycle data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RProdCycle(ref ThermoModels.ProdCycleModel currProdCycle)
+ {
+ List currMem = new List();
+ CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_CYCLE.MemType, PROCESS_PROD_CYCLE.Address, PROCESS_PROD_CYCLE.SubAddress, 0, PROCESS_PROD_CYCLE.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // converto!
+ currProdCycle = new ThermoModels.ProdCycleModel()
+ {
+ Status = S7.Net.Types.Word.FromByteArray(currMem.Skip(0).Take(2).ToArray()),
+ MessageId = S7.Net.Types.Word.FromByteArray(currMem.Skip(2).Take(2).ToArray()),
+ Mode = S7.Net.Types.Byte.FromByteArray(currMem.Skip(4).Take(1).ToArray()),
+ Submode = S7.Net.Types.Byte.FromByteArray(currMem.Skip(5).Take(1).ToArray()),
+ TimeAdv = S7.Net.Types.DWord.FromByteArray(currMem.Skip(6).Take(4).ToArray())
+ };
+
+ return NO_ERROR;
+ }
+
+ ///
+ /// Refresh recipE parameters RT
+ ///
+ protected CmsError refreshMemRecipeParameterRT()
+ {
+ CmsError libraryError = NO_ERROR;
+ List currMem = new List();
+ int packSize = 8;
+
+ // leggo da PLC a array di byte di appoggio...
+ libraryError = MEM_RWByteList(R, 0, PARAMETER_RT_DATA.MemType, PARAMETER_RT_DATA.Address, PARAMETER_RT_DATA.SubAddress, 0, PARAMETER_RT_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ // controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < PARAMETER_RT_DATA.Size / packSize; i++)
+ {
+ PlcParamRT currParam = new PlcParamRT(memArray.Skip(i * packSize).Take(packSize).ToArray());
+ // solo se ID > 0...
+ if (currParam.Id > 0)
+ {
+ // update oggetto thermoParamList...
+ if (ThermoParamList.ContainsKey(currParam.Id))
+ {
+ try
+ {
+ ThermoParamList[currParam.Id].Enabled = currParam.Enabled;
+ ThermoParamList[currParam.Id].HasError = currParam.HasError;
+ ThermoParamList[currParam.Id].Visible = currParam.Visible;
+ ThermoParamList[currParam.Id].ValueAct = currParam.ValueAct;
+ }
+ catch
+ { }
+ }
+ else
+ {
+ try
+ {
+ ThermoParamList.Add(currParam.Id, new ThermoModels.RecipeParam() { Id = currParam.Id, Enabled = currParam.Enabled, HasError = currParam.HasError, Visible = currParam.Visible, ValueAct = currParam.ValueAct });
+ }
+ catch
+ { }
+ }
+ }
+ }
+ }
+
+ return libraryError;
+ }
+ ///
+ /// Refresh recipe parameters
+ ///
+ protected CmsError refreshMemRecipeParameter()
+ {
+ CmsError libraryError = NO_ERROR;
+ List currMem = new List();
+ int packSize = 20;
+
+ // leggo da PLC a array di byte di appoggio...
+ libraryError = MEM_RWByteList(R, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress, 0, PARAMETER_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+
+
+ // controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+
+ for (int i = 0; i < PARAMETER_DATA.Size / packSize; i++)
+ {
+ PlcParam currParam = new PlcParam(memArray.Skip(i * packSize).Take(packSize).ToArray());
+ // solo se ID > 0...
+ if (currParam.Id > 0)
+ {
+ // update oggetto thermoParamList...
+ if (ThermoParamList.ContainsKey(currParam.Id))
+ {
+ try
+ {
+ ThermoParamList[currParam.Id].SetpointHMI = currParam.SetpointHMI;
+ ThermoParamList[currParam.Id].SetpointPLC = currParam.SetpointPLC;
+ ThermoParamList[currParam.Id].ValMax = currParam.ValMax;
+ ThermoParamList[currParam.Id].ValMin = currParam.ValMin;
+ ThermoParamList[currParam.Id].UnitMeasure = currParam.UnitMeasure;
+ }
+ catch
+ { }
+ }
+ else
+ {
+ try
+ {
+ ThermoParamList.Add(currParam.Id, new ThermoModels.RecipeParam() { Id = currParam.Id, SetpointHMI = currParam.SetpointHMI, SetpointPLC = currParam.SetpointPLC, ValMax = currParam.ValMax, ValMin = currParam.ValMin, UnitMeasure = currParam.UnitMeasure });
+ }
+ catch
+ { }
+ }
+ }
+ else
+ {
+ libraryError = S7_PLC_WRONG_DATA;
+ }
+ }
}
else
{
- try
- {
- ThermoParamList.Add(currParam.Id, new ThermoModels.RecipeParam() { Id = currParam.Id, Enabled = currParam.Enabled, HasError = currParam.HasError, Visible = currParam.Visible, ValueAct = currParam.ValueAct });
- }
- catch
- { }
+ libraryError = S7_PLC_EMPTY_READ;
}
- }
+
+
+ return libraryError;
}
- }
-
- return libraryError;
- }
- ///
- /// Refresh recipe parameters
- ///
- protected CmsError refreshMemRecipeParameter()
- {
- CmsError libraryError = NO_ERROR;
- List currMem = new List();
- int packSize = 20;
-
- // leggo da PLC a array di byte di appoggio...
- libraryError = MEM_RWByteList(R, 0, PARAMETER_DATA.MemType, PARAMETER_DATA.Address, PARAMETER_DATA.SubAddress, 0, PARAMETER_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
-
-
-
- // controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
-
- for (int i = 0; i < PARAMETER_DATA.Size / packSize; i++)
+ ///
+ /// Oggetto Parametro RT da PLC
+ ///
+ protected class PlcParamRT
{
- PlcParam currParam = new PlcParam(memArray.Skip(i * packSize).Take(packSize).ToArray());
- // solo se ID > 0...
- if (currParam.Id > 0)
- {
- // update oggetto thermoParamList...
- if (ThermoParamList.ContainsKey(currParam.Id))
+ public short Id { get; set; } = 0;
+ private byte Stato { get; set; } = 0;
+ public bool Visible { get; set; }
+ public bool Enabled { get; set; }
+ public bool HasError { get; set; }
+ public int ValueAct { get; set; } = 0;
+ ///
+ /// Deserializzazione da byte ad oggetto ParamRT
+ ///
+ ///
+ public PlcParamRT(byte[] rawData)
{
- try
- {
- ThermoParamList[currParam.Id].SetpointHMI = currParam.SetpointHMI;
- ThermoParamList[currParam.Id].SetpointPLC = currParam.SetpointPLC;
- ThermoParamList[currParam.Id].ValMax = currParam.ValMax;
- ThermoParamList[currParam.Id].ValMin = currParam.ValMin;
- ThermoParamList[currParam.Id].UnitMeasure = currParam.UnitMeasure;
- }
- catch
- { }
- }
- else
- {
- try
- {
- ThermoParamList.Add(currParam.Id, new ThermoModels.RecipeParam() { Id = currParam.Id, SetpointHMI = currParam.SetpointHMI, SetpointPLC = currParam.SetpointPLC, ValMax = currParam.ValMax, ValMin = currParam.ValMin, UnitMeasure = currParam.UnitMeasure });
- }
- catch
- { }
- }
- }
- else
- {
- libraryError = S7_PLC_WRONG_DATA;
- }
- }
- }
- else
- {
- libraryError = S7_PLC_EMPTY_READ;
- }
-
-
- return libraryError;
- }
- ///
- /// Oggetto Parametro RT da PLC
- ///
- protected class PlcParamRT
- {
- public short Id { get; set; } = 0;
- private byte Stato { get; set; } = 0;
- public bool Visible { get; set; }
- public bool Enabled { get; set; }
- public bool HasError { get; set; }
- public int ValueAct { get; set; } = 0;
- ///
- /// Deserializzazione da byte ad oggetto ParamRT
- ///
- ///
- public PlcParamRT(byte[] rawData)
- {
- // converto i dati da byte grezzi ai 3 componenti...
- Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
- ValueAct = S7.Net.Types.DInt.FromByteArray(rawData.Skip(4).Take(4).ToArray());
- Visible = S7.Net.Types.Boolean.GetValue(rawData[2], 0);
- Enabled = S7.Net.Types.Boolean.GetValue(rawData[2], 1);
- HasError = S7.Net.Types.Boolean.GetValue(rawData[2], 2);
+ // converto i dati da byte grezzi ai 3 componenti...
+ Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
+ ValueAct = S7.Net.Types.DInt.FromByteArray(rawData.Skip(4).Take(4).ToArray());
+ Visible = S7.Net.Types.Boolean.GetValue(rawData[2], 0);
+ Enabled = S7.Net.Types.Boolean.GetValue(rawData[2], 1);
+ HasError = S7.Net.Types.Boolean.GetValue(rawData[2], 2);
#if false
// calcolo bit...
Stato = S7.Net.Types.Word.FromByteArray(rawData.Skip(2).Take(2).Reverse().ToArray());
@@ -2637,518 +2679,518 @@ namespace CMS_CORE_Library.S7Net
Enabled = (Stato & 2) == 2;
HasError = (Stato & 4) == 4;
#endif
- }
- ///
- /// Converte un singolo item in un array di byte per scrittura su PLC S7
- ///
- ///
- public byte[] convertToByte()
- {
- // convero stato dai bit...
- Stato = 0;
- Stato += (byte)(Visible ? 1 : 0);
- Stato += (byte)(Enabled ? 2 : 0);
- Stato += (byte)(HasError ? 4 : 0);
- byte[] answ = new byte[8];
- Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
- Buffer.BlockCopy(S7.Net.Types.Byte.ToByteArray(Stato), 0, answ, 2, 1);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ValueAct), 0, answ, 4, 4);
- return answ;
- }
- }
- ///
- /// Oggetto Parametro da PLC
- ///
- protected class PlcParam
- {
- public short Id { get; set; } = 0;
- public int SetpointHMI { get; set; } = 0;
- public int SetpointPLC { get; set; } = 0;
- public int ValMax { get; set; } = 0;
- public int ValMin { get; set; } = 0;
- public ushort UnitMeasure { get; set; } = 0;
- ///
- /// Deserializzazione da byte ad oggetto Param
- ///
- ///
- public PlcParam(byte[] rawData)
- {
- // converto i dati da byte grezzi ai 3 componenti...
- Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
- SetpointHMI = S7.Net.Types.DInt.FromByteArray(rawData.Skip(2).Take(4).ToArray());
- SetpointPLC = S7.Net.Types.DInt.FromByteArray(rawData.Skip(6).Take(4).ToArray());
- ValMax = S7.Net.Types.DInt.FromByteArray(rawData.Skip(10).Take(4).ToArray());
- ValMin = S7.Net.Types.DInt.FromByteArray(rawData.Skip(14).Take(4).ToArray());
- UnitMeasure = S7.Net.Types.Word.FromByteArray(rawData.Skip(18).Take(2).ToArray());
- }
- ///
- /// Converte un singolo item in un array di byte per scrittura su PLC S7
- ///
- ///
- public byte[] convertToByte()
- {
- byte[] answ = new byte[20];
- Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(SetpointHMI), 0, answ, 2, 4);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(SetpointPLC), 0, answ, 6, 4);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ValMax), 0, answ, 10, 4);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ValMin), 0, answ, 14, 4);
- Buffer.BlockCopy(S7.Net.Types.Word.ToByteArray(UnitMeasure), 0, answ, 18, 2);
- return answ;
- }
- }
-
- ///
- /// Refresh ModuleBlock RT
- ///
- protected void refreshMemModBlockParameterRT()
- {
- List currMem = new List();
- int packSize = 12;
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, MODULE_RT_DATA.MemType, MODULE_RT_DATA.Address, MODULE_RT_DATA.SubAddress, 0, MODULE_RT_DATA.Size, ref currMem);
-
- // controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < MODULE_RT_DATA.Size / packSize; i++)
- {
- PlcModBlockRT currModBlock = new PlcModBlockRT(memArray.Skip(i * packSize).Take(packSize).ToArray());
- // solo se ID > 0...
- if (currModBlock.Id > 0)
- {
- // update oggetto thermoParamList...
- if (ThermoModuleList.ContainsKey(currModBlock.Id))
- {
- try
- {
- ThermoModuleList[currModBlock.Id].Visible = currModBlock.Visible;
- ThermoModuleList[currModBlock.Id].Running = currModBlock.Running;
- ThermoModuleList[currModBlock.Id].HasError = currModBlock.HasError;
- ThermoModuleList[currModBlock.Id].Terminated = currModBlock.Terminated;
- ThermoModuleList[currModBlock.Id].ActualDuration = currModBlock.ActualDuration;
- ThermoModuleList[currModBlock.Id].ActualDelay = currModBlock.ActualDelay;
- }
- catch
- { }
}
- else
+ ///
+ /// Converte un singolo item in un array di byte per scrittura su PLC S7
+ ///
+ ///
+ public byte[] convertToByte()
{
- try
- {
- ThermoModuleList.Add(currModBlock.Id, new ThermoModels.ModuleBlock()
+ // convero stato dai bit...
+ Stato = 0;
+ Stato += (byte)(Visible ? 1 : 0);
+ Stato += (byte)(Enabled ? 2 : 0);
+ Stato += (byte)(HasError ? 4 : 0);
+ byte[] answ = new byte[8];
+ Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
+ Buffer.BlockCopy(S7.Net.Types.Byte.ToByteArray(Stato), 0, answ, 2, 1);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ValueAct), 0, answ, 4, 4);
+ return answ;
+ }
+ }
+ ///
+ /// Oggetto Parametro da PLC
+ ///
+ protected class PlcParam
+ {
+ public short Id { get; set; } = 0;
+ public int SetpointHMI { get; set; } = 0;
+ public int SetpointPLC { get; set; } = 0;
+ public int ValMax { get; set; } = 0;
+ public int ValMin { get; set; } = 0;
+ public ushort UnitMeasure { get; set; } = 0;
+ ///
+ /// Deserializzazione da byte ad oggetto Param
+ ///
+ ///
+ public PlcParam(byte[] rawData)
+ {
+ // converto i dati da byte grezzi ai 3 componenti...
+ Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
+ SetpointHMI = S7.Net.Types.DInt.FromByteArray(rawData.Skip(2).Take(4).ToArray());
+ SetpointPLC = S7.Net.Types.DInt.FromByteArray(rawData.Skip(6).Take(4).ToArray());
+ ValMax = S7.Net.Types.DInt.FromByteArray(rawData.Skip(10).Take(4).ToArray());
+ ValMin = S7.Net.Types.DInt.FromByteArray(rawData.Skip(14).Take(4).ToArray());
+ UnitMeasure = S7.Net.Types.Word.FromByteArray(rawData.Skip(18).Take(2).ToArray());
+ }
+ ///
+ /// Converte un singolo item in un array di byte per scrittura su PLC S7
+ ///
+ ///
+ public byte[] convertToByte()
+ {
+ byte[] answ = new byte[20];
+ Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(SetpointHMI), 0, answ, 2, 4);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(SetpointPLC), 0, answ, 6, 4);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ValMax), 0, answ, 10, 4);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ValMin), 0, answ, 14, 4);
+ Buffer.BlockCopy(S7.Net.Types.Word.ToByteArray(UnitMeasure), 0, answ, 18, 2);
+ return answ;
+ }
+ }
+
+ ///
+ /// Refresh ModuleBlock RT
+ ///
+ protected void refreshMemModBlockParameterRT()
+ {
+ List currMem = new List();
+ int packSize = 12;
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, MODULE_RT_DATA.MemType, MODULE_RT_DATA.Address, MODULE_RT_DATA.SubAddress, 0, MODULE_RT_DATA.Size, ref currMem);
+
+ // controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < MODULE_RT_DATA.Size / packSize; i++)
{
- Id = currModBlock.Id,
- ActualDuration = currModBlock.ActualDuration,
- ActualDelay = currModBlock.ActualDelay,
- Visible = currModBlock.Visible,
- Running = currModBlock.Running,
- HasError = currModBlock.HasError,
- Terminated = currModBlock.Terminated
- });
- }
- catch
- { }
- }
- }
- else
- {
- libraryError = S7_PLC_WRONG_DATA;
- }
- }
- }
- else
- {
- libraryError = S7_PLC_EMPTY_READ;
- }
- }
- ///
- /// Refresh ModuleBlock
- ///
- protected void refreshMemModBlockParameter()
- {
- List currMem = new List();
- int packSize = 18;
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, MODULE_DATA.MemType, MODULE_DATA.Address, MODULE_DATA.SubAddress, 0, MODULE_DATA.Size, ref currMem);
-
-
- // controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < MODULE_DATA.Size / packSize; i++)
- {
- PlcModBlock currModBlock = new PlcModBlock(memArray.Skip(i * packSize).Take(packSize).ToArray());
- // calcolo lista PrecId
- List PrecId = new List();
- PrecId.Add(currModBlock.PrevId_01);
- PrecId.Add(currModBlock.PrevId_02);
- PrecId.Add(currModBlock.PrevId_03);
- // solo se ID > 0...
- if (currModBlock.Id > 0)
- {
- // update oggetto thermoParamList...
- if (ThermoModuleList.ContainsKey(currModBlock.Id))
- {
- ThermoModuleList[currModBlock.Id].EstimatedDelay = currModBlock.EstimDelay;
- ThermoModuleList[currModBlock.Id].EstimatedDuration = currModBlock.EstimDuration;
- ThermoModuleList[currModBlock.Id].PrecedingId = PrecId;
+ PlcModBlockRT currModBlock = new PlcModBlockRT(memArray.Skip(i * packSize).Take(packSize).ToArray());
+ // solo se ID > 0...
+ if (currModBlock.Id > 0)
+ {
+ // update oggetto thermoParamList...
+ if (ThermoModuleList.ContainsKey(currModBlock.Id))
+ {
+ try
+ {
+ ThermoModuleList[currModBlock.Id].Visible = currModBlock.Visible;
+ ThermoModuleList[currModBlock.Id].Running = currModBlock.Running;
+ ThermoModuleList[currModBlock.Id].HasError = currModBlock.HasError;
+ ThermoModuleList[currModBlock.Id].Terminated = currModBlock.Terminated;
+ ThermoModuleList[currModBlock.Id].ActualDuration = currModBlock.ActualDuration;
+ ThermoModuleList[currModBlock.Id].ActualDelay = currModBlock.ActualDelay;
+ }
+ catch
+ { }
+ }
+ else
+ {
+ try
+ {
+ ThermoModuleList.Add(currModBlock.Id, new ThermoModels.ModuleBlock()
+ {
+ Id = currModBlock.Id,
+ ActualDuration = currModBlock.ActualDuration,
+ ActualDelay = currModBlock.ActualDelay,
+ Visible = currModBlock.Visible,
+ Running = currModBlock.Running,
+ HasError = currModBlock.HasError,
+ Terminated = currModBlock.Terminated
+ });
+ }
+ catch
+ { }
+ }
+ }
+ else
+ {
+ libraryError = S7_PLC_WRONG_DATA;
+ }
+ }
}
else
{
- ThermoModuleList.Add(currModBlock.Id, new ThermoModels.ModuleBlock()
- {
- Id = currModBlock.Id,
- EstimatedDelay = currModBlock.EstimDelay,
- EstimatedDuration = currModBlock.EstimDuration,
- PrecedingId = PrecId
- });
+ libraryError = S7_PLC_EMPTY_READ;
}
- }
- else
- {
- libraryError = S7_PLC_WRONG_DATA;
- }
}
- }
- else
- {
- libraryError = S7_PLC_EMPTY_READ;
- }
- }
- ///
- /// Oggetto Modulo Blocco RT da PLC
- ///
- protected class PlcModBlockRT
- {
- public short Id { get; set; } = 0;
- public int ActualDuration { get; set; } = 0;
- public int ActualDelay { get; set; } = 0;
- private ushort Stato { get; set; } = 0;
- public bool Visible { get; set; }
- public bool Running { get; set; }
- public bool HasError { get; set; }
- public bool Terminated { get; set; } = false;
- ///
- /// Deserializzazione da byte ad oggetto ParamRT
- ///
- ///
- public PlcModBlockRT(byte[] rawData)
- {
- // converto i dati da byte grezzi ai 3 componenti...
- Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
- ActualDuration = S7.Net.Types.DInt.FromByteArray(rawData.Skip(2).Take(4).ToArray());
- ActualDelay = S7.Net.Types.DInt.FromByteArray(rawData.Skip(6).Take(4).ToArray());
- // sono in realtà BIT STRUC --> reverse!
- Stato = S7.Net.Types.Word.FromByteArray(rawData.Skip(10).Take(2).Reverse().ToArray());
- // calcolo bit...
- Visible = (Stato & 1) == 1;
- Running = (Stato & 2) == 2;
- HasError = (Stato & 4) == 4;
- Terminated = (Stato & 8) == 8;
- }
- ///
- /// Converte un singolo item in un array di byte per scrittura su PLC S7
- ///
- ///
- public byte[] convertToByte()
- {
- // convero stato dai bit...
- Stato = 0;
- Stato += (ushort)(Visible ? 1 : 0);
- Stato += (ushort)(Running ? 2 : 0);
- Stato += (ushort)(HasError ? 4 : 0);
- Stato += (ushort)(Terminated ? 8 : 0);
- byte[] answ = new byte[12];
- Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ActualDuration), 0, answ, 2, 4);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ActualDelay), 0, answ, 6, 4);
- Buffer.BlockCopy(S7.Net.Types.Word.ToByteArray(Stato), 0, answ, 10, 1);
- return answ;
- }
- }
- ///
- /// Oggetto Modulo Blocco da PLC
- ///
- protected class PlcModBlock
- {
- public short Id { get; set; } = 0;
- public int EstimDuration { get; set; } = 0;
- public int EstimDelay { get; set; } = 0;
- public short PrevId_01 { get; set; } = 0;
- public short PrevId_02 { get; set; } = 0;
- public short PrevId_03 { get; set; } = 0;
- ///
- /// Deserializzazione da byte ad oggetto Param
- ///
- ///
- public PlcModBlock(byte[] rawData)
- {
- // converto i dati da byte grezzi ai 3 componenti...
- Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
- EstimDuration = S7.Net.Types.DInt.FromByteArray(rawData.Skip(2).Take(4).ToArray());
- EstimDelay = S7.Net.Types.DInt.FromByteArray(rawData.Skip(6).Take(4).ToArray());
- PrevId_01 = S7.Net.Types.Int.FromByteArray(rawData.Skip(12).Take(2).ToArray());
- PrevId_02 = S7.Net.Types.Int.FromByteArray(rawData.Skip(14).Take(2).ToArray());
- PrevId_03 = S7.Net.Types.Int.FromByteArray(rawData.Skip(16).Take(2).ToArray());
- }
- ///
- /// Converte un singolo item in un array di byte per scrittura su PLC S7
- ///
- ///
- public byte[] convertToByte()
- {
- byte[] answ = new byte[18];
- Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(EstimDuration), 0, answ, 2, 4);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(EstimDelay), 0, answ, 6, 4);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(PrevId_01), 0, answ, 12, 2);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(PrevId_02), 0, answ, 14, 2);
- Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(PrevId_03), 0, answ, 16, 2);
- return answ;
- }
- }
-
- ///
- /// Refresh Canali Riscaldi: SetPoint Termocamera
- ///
- private void refreshRiscSetpointTermoCam()
- {
- // FIXME TODO ???? da dove prendere info?
- }
- ///
- /// Refresh Canali Riscaldi: SetPoint HMI
- ///
- private void refreshRiscSetpointHMI()
- {
- // leggo DB514 x area Ich
- List currMem = new List();
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
-
- // copio! controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < RISC_CHP_DATA.Size; i++)
+ ///
+ /// Refresh ModuleBlock
+ ///
+ protected void refreshMemModBlockParameter()
{
- // cerco id + 1 (su memoria è base 0)
- if (ThermoWarmChannels.ContainsKey(i + 1))
- {
- try
+ List currMem = new List();
+ int packSize = 18;
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, MODULE_DATA.MemType, MODULE_DATA.Address, MODULE_DATA.SubAddress, 0, MODULE_DATA.Size, ref currMem);
+
+
+ // controllo SE ho dati...
+ if (currMem.Count > 0)
{
- ThermoWarmChannels[i + 1].SetpointHMI = memArray[i];
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < MODULE_DATA.Size / packSize; i++)
+ {
+ PlcModBlock currModBlock = new PlcModBlock(memArray.Skip(i * packSize).Take(packSize).ToArray());
+ // calcolo lista PrecId
+ List PrecId = new List();
+ PrecId.Add(currModBlock.PrevId_01);
+ PrecId.Add(currModBlock.PrevId_02);
+ PrecId.Add(currModBlock.PrevId_03);
+ // solo se ID > 0...
+ if (currModBlock.Id > 0)
+ {
+ // update oggetto thermoParamList...
+ if (ThermoModuleList.ContainsKey(currModBlock.Id))
+ {
+ ThermoModuleList[currModBlock.Id].EstimatedDelay = currModBlock.EstimDelay;
+ ThermoModuleList[currModBlock.Id].EstimatedDuration = currModBlock.EstimDuration;
+ ThermoModuleList[currModBlock.Id].PrecedingId = PrecId;
+ }
+ else
+ {
+ ThermoModuleList.Add(currModBlock.Id, new ThermoModels.ModuleBlock()
+ {
+ Id = currModBlock.Id,
+ EstimatedDelay = currModBlock.EstimDelay,
+ EstimatedDuration = currModBlock.EstimDuration,
+ PrecedingId = PrecId
+ });
+ }
+ }
+ else
+ {
+ libraryError = S7_PLC_WRONG_DATA;
+ }
+ }
}
- catch
- { }
- }
- else
- {
- ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ else
{
- IdChannel = i + 1,
- SetpointHMI = memArray[i]
- });
- }
- }
- }
- else
- {
- libraryError = S7_PLC_EMPTY_READ;
- }
- }
- ///
- /// Refresh Canali Riscaldi: SetPoint PLC
- ///
- private void refreshRiscSetpointPLC()
- {
- // leggo DB514 x area Ich
- List currMem = new List();
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_PLC_DATA.MemType, RISC_PLC_DATA.Address, RISC_PLC_DATA.SubAddress, 0, RISC_PLC_DATA.Size, ref currMem);
-
- // copio! controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < RISC_PLC_DATA.Size; i++)
- {
- // cerco id + 1 (su memoria è base 0)
- if (ThermoWarmChannels.ContainsKey(i + 1))
- {
- ThermoWarmChannels[i + 1].SetpointPLC = memArray[i];
- }
- else
- {
- ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
- {
- IdChannel = i + 1,
- SetpointPLC = memArray[i]
- });
- }
- }
- }
- }
- ///
- /// Refresh Canali Riscaldi: actual current PLC
- ///
- private void refreshRiscActCurr()
- {
- // leggo DB514 x area Ich
- List currMem = new List();
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_ICH_DATA.MemType, RISC_ICH_DATA.Address, RISC_ICH_DATA.SubAddress, 0, RISC_ICH_DATA.Size, ref currMem);
-
- // copio! controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- double currVal = 0;
- for (int i = 0; i < RISC_ICH_DATA.Size / 4; i++)
- {
- currVal = S7.Net.Types.Double.FromByteArray(memArray.Skip(4 * i).Take(4).ToArray());
- // cerco id + 1 (su memoria è base 0)
- if (ThermoWarmChannels.ContainsKey(i + 1))
- {
- ThermoWarmChannels[i + 1].CurrAct = currVal;
- }
- else
- {
- try
- {
- ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
- {
- IdChannel = i + 1,
- CurrAct = currVal
- });
+ libraryError = S7_PLC_EMPTY_READ;
}
- catch
- { }
- }
}
- }
- }
- ///
- /// Refresh Canali Riscaldi: Percentuale Attuale
- ///
- private void refreshRiscPerc()
- {
- // leggo DB514 x area OVp
- List currMem = new List();
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_OVP_DATA.MemType, RISC_OVP_DATA.Address, RISC_OVP_DATA.SubAddress, 0, RISC_OVP_DATA.Size, ref currMem);
-
- // copio! controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < RISC_OVP_DATA.Size; i++)
+ ///
+ /// Oggetto Modulo Blocco RT da PLC
+ ///
+ protected class PlcModBlockRT
{
- // cerco id + 1 (su memoria è base 0)
- if (ThermoWarmChannels.ContainsKey(i + 1))
- {
- ThermoWarmChannels[i + 1].PercAct = memArray[i];
- }
- else
- {
- ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ public short Id { get; set; } = 0;
+ public int ActualDuration { get; set; } = 0;
+ public int ActualDelay { get; set; } = 0;
+ private ushort Stato { get; set; } = 0;
+ public bool Visible { get; set; }
+ public bool Running { get; set; }
+ public bool HasError { get; set; }
+ public bool Terminated { get; set; } = false;
+ ///
+ /// Deserializzazione da byte ad oggetto ParamRT
+ ///
+ ///
+ public PlcModBlockRT(byte[] rawData)
{
- IdChannel = i + 1,
- PercAct = memArray[i]
- });
- }
+ // converto i dati da byte grezzi ai 3 componenti...
+ Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
+ ActualDuration = S7.Net.Types.DInt.FromByteArray(rawData.Skip(2).Take(4).ToArray());
+ ActualDelay = S7.Net.Types.DInt.FromByteArray(rawData.Skip(6).Take(4).ToArray());
+ // sono in realtà BIT STRUC --> reverse!
+ Stato = S7.Net.Types.Word.FromByteArray(rawData.Skip(10).Take(2).Reverse().ToArray());
+ // calcolo bit...
+ Visible = (Stato & 1) == 1;
+ Running = (Stato & 2) == 2;
+ HasError = (Stato & 4) == 4;
+ Terminated = (Stato & 8) == 8;
+ }
+ ///
+ /// Converte un singolo item in un array di byte per scrittura su PLC S7
+ ///
+ ///
+ public byte[] convertToByte()
+ {
+ // convero stato dai bit...
+ Stato = 0;
+ Stato += (ushort)(Visible ? 1 : 0);
+ Stato += (ushort)(Running ? 2 : 0);
+ Stato += (ushort)(HasError ? 4 : 0);
+ Stato += (ushort)(Terminated ? 8 : 0);
+ byte[] answ = new byte[12];
+ Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ActualDuration), 0, answ, 2, 4);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(ActualDelay), 0, answ, 6, 4);
+ Buffer.BlockCopy(S7.Net.Types.Word.ToByteArray(Stato), 0, answ, 10, 1);
+ return answ;
+ }
}
- }
- }
- ///
- /// Refresh Canali Riscaldi: Status
- ///
- private void refreshRiscStatus()
- {
- // leggo DB514 x area ESP
- List currMem = new List();
-
- // leggo da PLC a array di byte di appoggio...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_ESP_DATA.MemType, RISC_ESP_DATA.Address, RISC_ESP_DATA.SubAddress, 0, RISC_ESP_DATA.Size, ref currMem);
-
- // copio! controllo SE ho dati...
- if (currMem.Count > 0)
- {
- // converto a blocchi di 8 byte...
- byte[] memArray = currMem.ToArray();
- for (int i = 0; i < RISC_ESP_DATA.Size; i++)
+ ///
+ /// Oggetto Modulo Blocco da PLC
+ ///
+ protected class PlcModBlock
{
- // cerco id + 1 (su memoria è base 0)
- if (ThermoWarmChannels.ContainsKey(i + 1))
- {
- ThermoWarmChannels[i + 1].ChStatus = memArray[i];
- }
- else
- {
- ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ public short Id { get; set; } = 0;
+ public int EstimDuration { get; set; } = 0;
+ public int EstimDelay { get; set; } = 0;
+ public short PrevId_01 { get; set; } = 0;
+ public short PrevId_02 { get; set; } = 0;
+ public short PrevId_03 { get; set; } = 0;
+ ///
+ /// Deserializzazione da byte ad oggetto Param
+ ///
+ ///
+ public PlcModBlock(byte[] rawData)
{
- IdChannel = i + 1,
- ChStatus = memArray[i]
- });
- }
+ // converto i dati da byte grezzi ai 3 componenti...
+ Id = S7.Net.Types.Int.FromByteArray(rawData.Skip(0).Take(2).ToArray());
+ EstimDuration = S7.Net.Types.DInt.FromByteArray(rawData.Skip(2).Take(4).ToArray());
+ EstimDelay = S7.Net.Types.DInt.FromByteArray(rawData.Skip(6).Take(4).ToArray());
+ PrevId_01 = S7.Net.Types.Int.FromByteArray(rawData.Skip(12).Take(2).ToArray());
+ PrevId_02 = S7.Net.Types.Int.FromByteArray(rawData.Skip(14).Take(2).ToArray());
+ PrevId_03 = S7.Net.Types.Int.FromByteArray(rawData.Skip(16).Take(2).ToArray());
+ }
+ ///
+ /// Converte un singolo item in un array di byte per scrittura su PLC S7
+ ///
+ ///
+ public byte[] convertToByte()
+ {
+ byte[] answ = new byte[18];
+ Buffer.BlockCopy(S7.Net.Types.Int.ToByteArray(Id), 0, answ, 0, 2);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(EstimDuration), 0, answ, 2, 4);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(EstimDelay), 0, answ, 6, 4);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(PrevId_01), 0, answ, 12, 2);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(PrevId_02), 0, answ, 14, 2);
+ Buffer.BlockCopy(S7.Net.Types.DInt.ToByteArray(PrevId_03), 0, answ, 16, 2);
+ return answ;
+ }
}
- }
- }
- ///
- /// Write Warmers channels load data
- ///
- ///
- ///
- public override CmsError PLC_WWarmerChSetpHmi(Dictionary newData)
- {
- // memory area
- byte[] newMem = new byte[newData.Count];
- List currMem = new List();
+ ///
+ /// Refresh Canali Riscaldi: SetPoint Termocamera
+ ///
+ private void refreshRiscSetpointTermoCam()
+ {
+ // FIXME TODO ???? da dove prendere info?
+ }
+ ///
+ /// Refresh Canali Riscaldi: SetPoint HMI
+ ///
+ private void refreshRiscSetpointHMI()
+ {
+ // leggo DB514 x area Ich
+ List currMem = new List();
- // read actual data on memory...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
- newMem = currMem.ToArray();
+ // copio! controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < RISC_CHP_DATA.Size; i++)
+ {
+ // cerco id + 1 (su memoria è base 0)
+ if (ThermoWarmChannels.ContainsKey(i + 1))
+ {
+ try
+ {
+ ThermoWarmChannels[i + 1].SetpointHMI = memArray[i];
+ }
+ catch
+ { }
+ }
+ else
+ {
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ {
+ IdChannel = i + 1,
+ SetpointHMI = memArray[i]
+ });
+ }
+ }
+ }
+ else
+ {
+ libraryError = S7_PLC_EMPTY_READ;
+ }
+ }
+ ///
+ /// Refresh Canali Riscaldi: SetPoint PLC
+ ///
+ private void refreshRiscSetpointPLC()
+ {
+ // leggo DB514 x area Ich
+ List currMem = new List();
- // update only given data...
- foreach (var item in newData)
- {
- newMem[item.Key - 1] = (byte)item.Value;
- }
- // return as list...
- currMem = newMem.ToList();
- // scrivo sul PLC array di byte...
- libraryError = MEM_RWByteList(W, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_PLC_DATA.MemType, RISC_PLC_DATA.Address, RISC_PLC_DATA.SubAddress, 0, RISC_PLC_DATA.Size, ref currMem);
- return NO_ERROR;
- }
- ///
- /// Write Warmers channels termocam data
- ///
- ///
- ///
- public override CmsError PLC_WWarmerChSetpTCam(Dictionary newData)
- {
- // FIXME TODO serve nuova area termocamera
+ // copio! controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < RISC_PLC_DATA.Size; i++)
+ {
+ // cerco id + 1 (su memoria è base 0)
+ if (ThermoWarmChannels.ContainsKey(i + 1))
+ {
+ ThermoWarmChannels[i + 1].SetpointPLC = memArray[i];
+ }
+ else
+ {
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ {
+ IdChannel = i + 1,
+ SetpointPLC = memArray[i]
+ });
+ }
+ }
+ }
+ }
+ ///
+ /// Refresh Canali Riscaldi: actual current PLC
+ ///
+ private void refreshRiscActCurr()
+ {
+ // leggo DB514 x area Ich
+ List currMem = new List();
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_ICH_DATA.MemType, RISC_ICH_DATA.Address, RISC_ICH_DATA.SubAddress, 0, RISC_ICH_DATA.Size, ref currMem);
+
+ // copio! controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ double currVal = 0;
+ for (int i = 0; i < RISC_ICH_DATA.Size / 4; i++)
+ {
+ currVal = S7.Net.Types.Double.FromByteArray(memArray.Skip(4 * i).Take(4).ToArray());
+ // cerco id + 1 (su memoria è base 0)
+ if (ThermoWarmChannels.ContainsKey(i + 1))
+ {
+ ThermoWarmChannels[i + 1].CurrAct = currVal;
+ }
+ else
+ {
+ try
+ {
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ {
+ IdChannel = i + 1,
+ CurrAct = currVal
+ });
+ }
+ catch
+ { }
+ }
+ }
+ }
+ }
+ ///
+ /// Refresh Canali Riscaldi: Percentuale Attuale
+ ///
+ private void refreshRiscPerc()
+ {
+ // leggo DB514 x area OVp
+ List currMem = new List();
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_OVP_DATA.MemType, RISC_OVP_DATA.Address, RISC_OVP_DATA.SubAddress, 0, RISC_OVP_DATA.Size, ref currMem);
+
+ // copio! controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < RISC_OVP_DATA.Size; i++)
+ {
+ // cerco id + 1 (su memoria è base 0)
+ if (ThermoWarmChannels.ContainsKey(i + 1))
+ {
+ ThermoWarmChannels[i + 1].PercAct = memArray[i];
+ }
+ else
+ {
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ {
+ IdChannel = i + 1,
+ PercAct = memArray[i]
+ });
+ }
+ }
+ }
+ }
+ ///
+ /// Refresh Canali Riscaldi: Status
+ ///
+ private void refreshRiscStatus()
+ {
+ // leggo DB514 x area ESP
+ List currMem = new List();
+
+ // leggo da PLC a array di byte di appoggio...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_ESP_DATA.MemType, RISC_ESP_DATA.Address, RISC_ESP_DATA.SubAddress, 0, RISC_ESP_DATA.Size, ref currMem);
+
+ // copio! controllo SE ho dati...
+ if (currMem.Count > 0)
+ {
+ // converto a blocchi di 8 byte...
+ byte[] memArray = currMem.ToArray();
+ for (int i = 0; i < RISC_ESP_DATA.Size; i++)
+ {
+ // cerco id + 1 (su memoria è base 0)
+ if (ThermoWarmChannels.ContainsKey(i + 1))
+ {
+ ThermoWarmChannels[i + 1].ChStatus = memArray[i];
+ }
+ else
+ {
+ ThermoWarmChannels.Add(i + 1, new ThermoModels.WarmerChannel()
+ {
+ IdChannel = i + 1,
+ ChStatus = memArray[i]
+ });
+ }
+ }
+ }
+ }
+
+ ///
+ /// Write Warmers channels load data
+ ///
+ ///
+ ///
+ public override CmsError PLC_WWarmerChSetpHmi(Dictionary newData)
+ {
+ // memory area
+ byte[] newMem = new byte[newData.Count];
+ List currMem = new List();
+
+ // read actual data on memory...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ newMem = currMem.ToArray();
+
+ // update only given data...
+ foreach (var item in newData)
+ {
+ newMem[item.Key - 1] = (byte)item.Value;
+ }
+ // return as list...
+ currMem = newMem.ToList();
+ // scrivo sul PLC array di byte...
+ libraryError = MEM_RWByteList(W, 0, RISC_CHP_DATA.MemType, RISC_CHP_DATA.Address, RISC_CHP_DATA.SubAddress, 0, RISC_CHP_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
+
+ return NO_ERROR;
+ }
+ ///
+ /// Write Warmers channels termocam data
+ ///
+ ///
+ ///
+ public override CmsError PLC_WWarmerChSetpTCam(Dictionary newData)
+ {
+ // FIXME TODO serve nuova area termocamera
#if false
// memory area
byte[] newMem = new byte[newData.Count];
@@ -3174,176 +3216,176 @@ namespace CMS_CORE_Library.S7Net
return libraryError;
#endif
- return NO_ERROR;
- }
- ///
- /// Set current Warmers Channels reflector's data
- ///
- ///
- ///
- public override CmsError PLC_WWarmerConfRefl(Dictionary newData)
- {
- // memory area
- byte[] newMem = new byte[newData.Count];
- List currMem = new List();
+ return NO_ERROR;
+ }
+ ///
+ /// Set current Warmers Channels reflector's data
+ ///
+ ///
+ ///
+ public override CmsError PLC_WWarmerConfRefl(Dictionary newData)
+ {
+ // memory area
+ byte[] newMem = new byte[newData.Count];
+ List currMem = new List();
- // read actual data on memory...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_CFI_DATA.MemType, RISC_CFI_DATA.Address, RISC_CFI_DATA.SubAddress, 0, RISC_CFI_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ // read actual data on memory...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_CFI_DATA.MemType, RISC_CFI_DATA.Address, RISC_CFI_DATA.SubAddress, 0, RISC_CFI_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
- newMem = currMem.ToArray();
+ newMem = currMem.ToArray();
- // update only given data...
- foreach (var item in newData)
- {
- // algoritmo: valore = (val + 1) % 8, ovvero riflettore 0, 8, 16 --> 1, riflettore 1, 9, 17 --> 2
- newMem[item.Key - 1] = (byte)((item.Value + 1) % 8);
- }
- // return as list...
- currMem = newMem.ToList();
- // scrivo sul PLC array di byte...
- libraryError = MEM_RWByteList(W, 0, RISC_CFI_DATA.MemType, RISC_CFI_DATA.Address, RISC_CFI_DATA.SubAddress, 0, RISC_CFI_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ // update only given data...
+ foreach (var item in newData)
+ {
+ // algoritmo: valore = (val + 1) % 8, ovvero riflettore 0, 8, 16 --> 1, riflettore 1, 9, 17 --> 2
+ newMem[item.Key - 1] = (byte)((item.Value + 1) % 8);
+ }
+ // return as list...
+ currMem = newMem.ToList();
+ // scrivo sul PLC array di byte...
+ libraryError = MEM_RWByteList(W, 0, RISC_CFI_DATA.MemType, RISC_CFI_DATA.Address, RISC_CFI_DATA.SubAddress, 0, RISC_CFI_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
- return NO_ERROR;
- }
- ///
- /// Get current Warmers VUMin data
- ///
- ///
- ///
- public override CmsError PLC_RWarmerConfVUMin(ref ushort VUmin)
- {
- // leggo da 513.0 --> default 210
- VUmin = 230;
- List currMem = new List();
+ return NO_ERROR;
+ }
+ ///
+ /// Get current Warmers VUMin data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RWarmerConfVUMin(ref ushort VUmin)
+ {
+ // leggo da 513.0 --> default 210
+ VUmin = 230;
+ List currMem = new List();
- // read actual data on memory...
- CmsError libraryError = MEM_RWWord(R, 0, RISC_VU_MIN.MemType, RISC_VU_MIN.Address, RISC_VU_MIN.SubAddress, ref VUmin);
- if (libraryError.IsError())
- return libraryError;
+ // read actual data on memory...
+ CmsError libraryError = MEM_RWWord(R, 0, RISC_VU_MIN.MemType, RISC_VU_MIN.Address, RISC_VU_MIN.SubAddress, ref VUmin);
+ if (libraryError.IsError())
+ return libraryError;
- return NO_ERROR;
- }
- ///
- /// Set current Warmers Channels min current data
- ///
- ///
- ///
- public override CmsError PLC_WWarmerConfMinCurr(Dictionary newData)
- {
- // memory area
- List ListValue = new List();
+ return NO_ERROR;
+ }
+ ///
+ /// Set current Warmers Channels min current data
+ ///
+ ///
+ ///
+ public override CmsError PLC_WWarmerConfMinCurr(Dictionary newData)
+ {
+ // memory area
+ List ListValue = new List();
- // read actual data on memory...
- CmsError libraryError = MEM_RWDoubleList(R, 0, RISC_ICH_MIN_DATA.MemType, RISC_ICH_MIN_DATA.Address, RISC_ICH_MIN_DATA.SubAddress, RISC_ICH_MIN_DATA.Size, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
+ // read actual data on memory...
+ CmsError libraryError = MEM_RWDoubleList(R, 0, RISC_ICH_MIN_DATA.MemType, RISC_ICH_MIN_DATA.Address, RISC_ICH_MIN_DATA.SubAddress, RISC_ICH_MIN_DATA.Size, ref ListValue);
+ if (libraryError.IsError())
+ return libraryError;
- var newMem = ListValue.ToArray();
+ var newMem = ListValue.ToArray();
- // update only given data...
- foreach (var item in newData)
- {
- // 2020.07.21 fix perché channes 1 based, memory 0 based
- newMem[item.Key - 1] = item.Value;
- }
- // return as list...
- ListValue = newMem.ToList();
- // scrivo sul PLC array di byte...
- libraryError = MEM_RWDoubleList(W, 0, RISC_ICH_MIN_DATA.MemType, RISC_ICH_MIN_DATA.Address, RISC_ICH_MIN_DATA.SubAddress, RISC_ICH_MIN_DATA.Size, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
+ // update only given data...
+ foreach (var item in newData)
+ {
+ // 2020.07.21 fix perché channes 1 based, memory 0 based
+ newMem[item.Key - 1] = item.Value;
+ }
+ // return as list...
+ ListValue = newMem.ToList();
+ // scrivo sul PLC array di byte...
+ libraryError = MEM_RWDoubleList(W, 0, RISC_ICH_MIN_DATA.MemType, RISC_ICH_MIN_DATA.Address, RISC_ICH_MIN_DATA.SubAddress, RISC_ICH_MIN_DATA.Size, ref ListValue);
+ if (libraryError.IsError())
+ return libraryError;
- return NO_ERROR;
- }
- ///
- /// Set current Warmers Channels reflector's data
- ///
- ///
- ///
- public override CmsError PLC_WWarmerConfBoardEnabl(Dictionary newData)
- {
- // memory area
- byte[] newMem = new byte[newData.Count];
- List currMem = new List();
+ return NO_ERROR;
+ }
+ ///
+ /// Set current Warmers Channels reflector's data
+ ///
+ ///
+ ///
+ public override CmsError PLC_WWarmerConfBoardEnabl(Dictionary newData)
+ {
+ // memory area
+ byte[] newMem = new byte[newData.Count];
+ List currMem = new List();
- // read actual data on memory...
- CmsError libraryError = MEM_RWByteList(R, 0, RISC_OCC_DATA.MemType, RISC_OCC_DATA.Address, RISC_OCC_DATA.SubAddress, 0, RISC_OCC_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ // read actual data on memory...
+ CmsError libraryError = MEM_RWByteList(R, 0, RISC_OCC_DATA.MemType, RISC_OCC_DATA.Address, RISC_OCC_DATA.SubAddress, 0, RISC_OCC_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
- newMem = currMem.ToArray();
+ newMem = currMem.ToArray();
- // update only given data...
- foreach (var item in newData)
- {
- newMem[item.Key] = (byte)item.Value;
- }
- // return as list...
- currMem = newMem.ToList();
- // scrivo sul PLC array di byte...
- libraryError = MEM_RWByteList(W, 0, RISC_OCC_DATA.MemType, RISC_OCC_DATA.Address, RISC_OCC_DATA.SubAddress, 0, RISC_OCC_DATA.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ // update only given data...
+ foreach (var item in newData)
+ {
+ newMem[item.Key] = (byte)item.Value;
+ }
+ // return as list...
+ currMem = newMem.ToList();
+ // scrivo sul PLC array di byte...
+ libraryError = MEM_RWByteList(W, 0, RISC_OCC_DATA.MemType, RISC_OCC_DATA.Address, RISC_OCC_DATA.SubAddress, 0, RISC_OCC_DATA.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
- return NO_ERROR;
- }
- ///
- /// Request for mode selection via strobe
- ///
- /// 1: MAN, 2: AUTO, 3: SETUP
- ///
- public override CmsError PLC_WModeSel(int mode)
- {
- // se update --> scrivo strobe comando update...
- if (mode == 1)
- {
- // Call confirm update
- CmsError libraryError = PLC_WStrobe(true, REQ_MODE_ACK, REQ_MODE_STROBE, 6);
- if (libraryError.IsError())
- return libraryError;
- }
- else
- if (mode == 2)
- {
- // Call confirm update
- CmsError libraryError = PLC_WStrobe(true, REQ_MODE_ACK, REQ_MODE_STROBE, 5);
- if (libraryError.IsError())
- return libraryError;
- }
- else
- if (mode == 3)
- {
- // Call confirm update
- CmsError libraryError = PLC_WStrobe(true, REQ_MODE_ACK, REQ_MODE_STROBE, 7);
- if (libraryError.IsError())
- return libraryError;
- }
+ return NO_ERROR;
+ }
+ ///
+ /// Request for mode selection via strobe
+ ///
+ /// 1: MAN, 2: AUTO, 3: SETUP
+ ///
+ public override CmsError PLC_WModeSel(int mode)
+ {
+ // se update --> scrivo strobe comando update...
+ if (mode == 1)
+ {
+ // Call confirm update
+ CmsError libraryError = PLC_WStrobe(true, REQ_MODE_ACK, REQ_MODE_STROBE, 6);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+ else
+ if (mode == 2)
+ {
+ // Call confirm update
+ CmsError libraryError = PLC_WStrobe(true, REQ_MODE_ACK, REQ_MODE_STROBE, 5);
+ if (libraryError.IsError())
+ return libraryError;
+ }
+ else
+ if (mode == 3)
+ {
+ // Call confirm update
+ CmsError libraryError = PLC_WStrobe(true, REQ_MODE_ACK, REQ_MODE_STROBE, 7);
+ if (libraryError.IsError())
+ return libraryError;
+ }
- return NO_ERROR;
- }
+ return NO_ERROR;
+ }
- #endregion
+ #endregion
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
+ ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
- #region PROCESS-AXES (PATH) High-level data
+ #region PROCESS-AXES (PATH) High-level data
- ///
- /// Get current Production Info data
- ///
- ///
- ///
- public override CmsError PLC_RAxesMov(ref ThermoModels.AxisRT currProdInfo)
- {
- List currMem = new List();
- CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
- if (libraryError.IsError())
- return libraryError;
+ ///
+ /// Get current Production Info data
+ ///
+ ///
+ ///
+ public override CmsError PLC_RAxesMov(ref ThermoModels.AxisRT currProdInfo)
+ {
+ List currMem = new List();
+ CmsError libraryError = MEM_RWByteList(R, 0, PROCESS_PROD_INFO.MemType, PROCESS_PROD_INFO.Address, PROCESS_PROD_INFO.SubAddress, 0, PROCESS_PROD_INFO.Size, ref currMem);
+ if (libraryError.IsError())
+ return libraryError;
#if false
// converto!
@@ -3366,1246 +3408,1246 @@ namespace CMS_CORE_Library.S7Net
};
#endif
- return NO_ERROR;
- }
-
- public override CmsError AXES_RInterpPosition(ushort channel, ref Dictionary axes)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_RMachinePosition(ushort channel, ref Dictionary axes)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_RProgrPosition(ushort channel, ref Dictionary axes)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_RFollowingError(ushort channel, ref Dictionary axes)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_RDistanceToGo(ushort channel, ref Dictionary axes)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- private Dictionary AXES_RAxesPos(ushort channel, string positionType)
- {
- Dictionary axes = new Dictionary();
- return axes;
- }
-
- public override CmsError AXES_RAxesNames(ushort channel, ref List axesData)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_RSelectedAxis(ref byte axisId)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_WSelectAxis(byte axisId)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- public override CmsError AXES_ROrigin(int numberOfAxes)
- {
- return FUNCTION_NOT_ALLOWED_ERROR;
- }
-
- #endregion PROCESS-AXES (PATH) High-level data
-
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
-
- #region NC Low-level function: single valiable in memory
-
- //Read-Write a Boolean-Value inside the NC.
- public override CmsError MEM_RWBoolean(bool bWrite, bool fixEndian, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, int MemBit, ref bool Value)
- {
- //Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
-
- //Check if the Bit Number is Correct
- libraryError = CheckBitRange(MemBit);
- if (libraryError.IsError())
- return libraryError;
-
- byte bValue = 0;
- ushort pow = (ushort)Math.Pow(2, MemBit);
-
- //Read the Byte where is the bit
- libraryError = MEM_RWByte(R, fixEndian, Process, MemType, MemTable, MemIndex, 0, ref bValue);
- if (libraryError.IsError())
- return libraryError;
-
- //If i have to Write -> Write the Bit
- if (bWrite)
- {
- if (Value)
- bValue = (byte)(bValue | (1 << MemBit));
- else
- bValue = (byte)(bValue & ~(1 << MemBit));
-
- libraryError = MEM_RWByte(W, fixEndian, Process, MemType, MemTable, MemIndex, 0, ref bValue);
- if (libraryError.IsError())
- return libraryError;
- }
- //If i have to read -> Read the Bit
- else
- {
- Value = (bValue & pow) == pow;
- }
-
- return NO_ERROR;
- }
-
- ///
- /// Read-Write a SINGLE Byte inside the NC. In writing-mode the field "Number" is not required
- ///
- /// R/W mode
- /// fix endianness
- ///
- ///
- ///
- ///
- ///
- ///
- ///
- public override CmsError MEM_RWByte(bool bWrite, bool fixEndian, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, int MemByte, ref byte Value)
- {
- //Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
-
- if (MemType != MEMORY_TYPE.Siemens_DB)
- {
- return INCORRECT_PARAMETERS_ERROR;
- }
-
- libraryError = null;
-
- // attenzione endianness! inverte byte se richiesto...
- int fixIndex = MemIndex;
- if (fixEndian)
- {
- fixIndex = MemIndex % 2 == 0 ? MemIndex + 1 : MemIndex - 1;
- }
-
- // vere operazioni R/W
- if (bWrite)
- {
- // try/catch
- try
- {
- byte[] DB_Byte = new byte[1];
- DB_Byte[0] = Value;
- currPLC.WriteBytes(DataType.DataBlock, MemTable, fixIndex, DB_Byte);
- }
- catch
- {
- return S7_PLC_WRITE_ERROR_BYTE;
- }
- }
- else
- {
- try
- {
- var memByteRead = currPLC.ReadBytes(DataType.DataBlock, MemTable, fixIndex, 1);
- Value = memByteRead[0];
- }
- catch
- {
- return S7_PLC_READ_ERROR_BYTE;
- }
- }
-
- return NO_ERROR;
- }
-
- //Write a Word-Value inside the NC. In writing-mode the field "Number" is not required
- public override CmsError MEM_RWWord(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, ref ushort Value)
- {
- List ListValue = new List() { Value };
-
- //uses the List method with one-element list
- CmsError libraryError = MEM_RWWordList(bWrite, Process, MemType, MemTable, MemIndex, 2, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
- if (ListValue.Count > 0)
- Value = ListValue.First();
-
- return NO_ERROR;
- }
-
- public override CmsError MEM_RWShort(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, ref short Value)
- {
- List ListValue = new List() { Value };
-
- //uses the List method with one-element list
- CmsError libraryError = MEM_RWShortList(bWrite, Process, MemType, MemTable, MemIndex, 1, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
-
- Value = ListValue.First();
-
- return NO_ERROR;
- }
-
- //Write a Word-Value inside the NC. In writing-mode the field "Number" is not required
- public override CmsError MEM_RWDWord(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, ref uint Value)
- {
- List ListValue = new List() { Value };
-
- //uses the List method with one-element list
- CmsError libraryError = MEM_RWDWordList(bWrite, Process, MemType, MemTable, MemIndex, 1, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
-
- Value = ListValue.First();
-
- return NO_ERROR;
- }
-
- public override CmsError MEM_RWDouble(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, ref double Value)
- {
- List ListValue = new List() { Value };
-
- //uses the List method with one-element list
- CmsError libraryError = MEM_RWDoubleList(bWrite, Process, MemType, MemTable, MemIndex, 4, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
-
- Value = ListValue.First();
-
- return NO_ERROR;
- }
-
- //Write a Int-Value inside the NC. In writing-mode the field "Number" is not required
- public override CmsError MEM_RWInteger(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, ref int Value)
- {
- List ListValue = new List() { Value };
-
- // uses the List method with one-element list, reading int32 (4byte) data...
- CmsError libraryError = MEM_RWIntegerList(bWrite, Process, MemType, MemTable, MemIndex, 1, ref ListValue);
- if (libraryError.IsError())
- return libraryError;
- if (ListValue.Count > 0)
- {
- Value = ListValue.First();
- }
-
- return NO_ERROR;
- }
-
-
- #endregion NC Low-level function: single valiable in memory
-
- ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
-
- #region Low level methods
-
- public override CmsError MEM_RWByteList(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, int MemByteStart, int Number, ref List Values)
- {
- //Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
-
- if (MemType != MEMORY_TYPE.Siemens_DB)
- {
- return INCORRECT_PARAMETERS_ERROR;
- }
-
- libraryError = null;
-
- if (bWrite)
- {
- //Prevent some exceptions
- if (Values.Count == 0)
- return NO_ERROR;
- // try/catch
- try
- {
- currPLC.WriteBytes(DataType.DataBlock, MemTable, MemIndex, Values.ToArray());
- }
- catch
- {
- return S7_PLC_WRITE_ERROR_LST_BYTE;
- }
- }
- else
- {
- // Prevent some exceptions
- if (Number == 0)
- return NO_ERROR;
- Values.Clear();
- try
- {
- byte[] memByteRead = currPLC.ReadBytes(DataType.DataBlock, MemTable, MemIndex, Number);
- Values = memByteRead.ToList();
- }
- catch
- {
- return S7_PLC_READ_ERROR_LST_BYTE;
- }
- }
-
- return NO_ERROR;
- }
-
- public override CmsError MEM_RWWordList(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, int Number, ref List Values)
- {
- ////Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
-
-
- if (MemType != MEMORY_TYPE.Siemens_DB)
- {
- return INCORRECT_PARAMETERS_ERROR;
- }
-
-
- libraryError = null;
-
- if (bWrite)
- {
- //Prevent some exceptions
- if (Values.Count == 0)
- return NO_ERROR;
-
- byte[] singleItem = new byte[2];
- List memByteList = new List();
-
- foreach (var Item in Values)
- {
- singleItem = S7.Net.Types.Word.ToByteArray(Item);
- memByteList.AddRange(singleItem);
- }
- try
- {
- currPLC.WriteBytes(DataType.DataBlock, MemTable, MemIndex, memByteList.ToArray());
- }
- catch
- {
- return S7_PLC_WRITE_ERROR_LST_WORD;
- }
- }
- else
- {
- // Prevent some exceptions
- if (Number == 0)
- return NO_ERROR;
-
- Values.Clear();
- byte[] memByteRead;
- try
- {
- memByteRead = currPLC.ReadBytes(DataType.DataBlock, MemTable, MemIndex, Number);
- // converto a word!
- ushort shortVal = 0;
- for (int i = 0; i < memByteRead.Length / 2; i++)
- {
- shortVal = S7.Net.Types.Word.FromByteArray(memByteRead.Skip(2 * i).Take(2).ToArray());
- Values.Add(shortVal);
- }
- }
- catch
- {
- return S7_PLC_READ_ERROR_LST_WORD;
- }
- }
-
- return NO_ERROR;
- }
-
- public override CmsError MEM_RWShortList(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, int Number, ref List Values)
- {
- //Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
-
- if (MemType != MEMORY_TYPE.Siemens_DB)
- {
- return INCORRECT_PARAMETERS_ERROR;
- }
-
-
- libraryError = null;
-
- if (bWrite)
- {
- //Prevent some exceptions
- if (Values.Count == 0)
- return NO_ERROR;
-
- byte[] singleItem = new byte[2];
- List memByteList = new List();
-
- foreach (var Item in Values)
- {
- singleItem = S7.Net.Types.Int.ToByteArray(Item);
- memByteList.AddRange(singleItem);
- }
- try
- {
- currPLC.WriteBytes(DataType.DataBlock, MemTable, MemIndex, memByteList.ToArray());
- }
- catch
- {
- return S7_PLC_WRITE_ERROR_LST_SHORT;
- }
- }
- else
- {
- // Prevent some exceptions
- if (Number == 0)
- return NO_ERROR;
-
- Values.Clear();
- try
- {
- byte[] memByteRead = currPLC.ReadBytes(DataType.DataBlock, MemTable, MemIndex, Number);
- // converto a word!
- short shortVal = 0;
- for (int i = 0; i < memByteRead.Length / 2; i++)
- {
- shortVal = S7.Net.Types.Int.FromByteArray(memByteRead.Skip(2 * i).Take(2).ToArray());
- Values.Add(shortVal);
- }
- }
- catch
- {
- return S7_PLC_READ_ERROR_LST_SHORT;
- }
- }
-
- return NO_ERROR;
- }
-
- public override CmsError MEM_RWDWordList(bool bWrite, int Process, MEMORY_TYPE MemType, int MemTable, int MemIndex, int Number, ref List Values)
- {
- //Check if the NC is Connected
- CmsError libraryError = CheckConnection();
- if (libraryError.IsError())
- return libraryError;
-
- if (MemType != MEMORY_TYPE.Siemens_DB)
- {
- return INCORRECT_PARAMETERS_ERROR;
- }
-
- libraryError = null;
-
- if (bWrite)
- {
- //Prevent some exceptions
- if (Values.Count == 0)
- return NO_ERROR;
-
- byte[] singleItem = new byte[4];
- List memByteList = new List();
-
- foreach (var Item in Values)
- {
- singleItem = S7.Net.Types.DWord.ToByteArray(Item);
- memByteList.AddRange(singleItem);
+ return NO_ERROR;
}