;Configurazione IOB-WIN
|
|
[IOB]
|
|
CNCTYPE=FANUC
|
|
|
|
[MACHINE]
|
|
; VALVITAL 2024
|
|
VENDOR=FFG
|
|
MODEL=CROSSFLEX A1600
|
|
|
|
[CNC]
|
|
; FANUC!
|
|
IP=192.168.214.100
|
|
PORT=9000
|
|
GETPRGNAME=true
|
|
|
|
[SERVER]
|
|
MPIP=192.168.214.4
|
|
MPURL=/MP/IO
|
|
CMDBASE=/IOB/input/
|
|
CMDFLOG=/IOB/flog/
|
|
CMDALIVE=/IOB
|
|
CMDENABLED=/IOB/enabled/
|
|
CMDADV1=?valore=
|
|
CMDREBO=/sendReboot.aspx?idxMacchina=
|
|
|
|
[MEMORY]
|
|
; Green 11.4 | Red: Y11.7 | Yellow: Y11.6 (bianco, eventualmente in lampeggio) | Emerg: X8.4 (negata)|
|
|
;BIT0=CONN
|
|
BIT1=Y11.4
|
|
BIT2=PZCOUNT.PAR.6711
|
|
BIT3=Y11.7
|
|
BIT4=Y11.6
|
|
BIT5=!X8.4
|
|
AREAD_START=0
|
|
AREAD_SIZE=9999
|
|
AREAG_SIZE=48
|
|
AREAR_START=0
|
|
AREAR_SIZE=64
|
|
AREAX_START=0
|
|
AREAX_SIZE=64
|
|
AREAY_START=0
|
|
AREAY_SIZE=64
|
|
PAR_START=6711
|
|
PAR_SIZE=3
|
|
|
|
[BLINK]
|
|
;MAX_COUNTER_BLINK = 30
|
|
MAX_COUNTER_BLINK = 15
|
|
;bit0 = 0
|
|
;bit1 = 0
|
|
;bit2 = 1
|
|
;bit3 = 1
|
|
;bit4 = 1
|
|
;bit5 = 0
|
|
;bit6 = 0
|
|
;bit7 = 0
|
|
BLINK_FILT=0
|
|
;BLINK_FILT=28
|
|
|
|
[OPTPAR]
|
|
;PZCOUNT_MODE=STD|BIT
|
|
;PZCOUNT_MODE=STD.MACRO.930
|
|
;PZGTOT_MODE=STD.MACRO.929
|
|
PZCOUNT_MODE=STD.MACRO.929
|
|
PZGTOT_MODE=STD.PAR.6712
|
|
PZREQ_MODE=STD.MACRO.964
|
|
ENABLE_PZ_REQ=TRUE
|
|
ENABLE_PZ_RESET=TRUE
|
|
ENABLE_PZ_RESET_stopSetup=TRUE
|
|
;gestione invio pezzi in blocco
|
|
ENABLE_SEND_PZC_BLOCK=TRUE
|
|
MIN_SEND_PZC_BLOCK=0
|
|
MAX_SEND_PZC_BLOCK=100
|
|
; conf cablata set Art/Commessa
|
|
SET_NUM_ART=STD.MACRO.966
|
|
SET_NUM_COM=STD.MACRO.965
|
|
;indica se il numero articolo sia semplicemente il trim dei caratteri alfabetici (chiama comunque server...)
|
|
NUM_ART_CHR_TRIM=TRUE
|
|
; conf parametri memoria READ/WRITE
|
|
PARAM_CONF=VL27.json
|
|
DISABLE_SEND_WDST=TRUE
|
|
|
|
[BRANCH]
|
|
NAME=master |