Files
Mapo-IOB-WIN/IOB-WIN-NEXT/DATA/CONF/VL27.ini
T
Samuele Locatelli fffdd2e568 EgwProxy.FTP:
- Aggiunto test x sync folder FTP local/remote
2024-10-04 15:14:10 +02:00

74 lines
1.1 KiB
INI

;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
[MACHINE]
; VALVITAL 2024
VENDOR=FFG
MODEL=CROSSFLEX A1600
[CNC]
; FANUC!
IP=192.168.1.12
PORT=9000
GETPRGNAME=true
[SERVER]
MPIP=192.168.214.4
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
; Green 11.4 | Red: Y11.7 | Yellow: Y11.6 (bianco, eventualmente in lampeggio) | Emerg: X8.4 |
;BIT0=CONN
BIT1=Y11.4
BIT2=PZCOUNT.PAR.6711
BIT3=Y11.7
BIT4=Y11.6
BIT5=X8.4
AREAD_START=0
AREAD_SIZE=9999
AREAG_SIZE=48
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD|BIT
PZCOUNT_MODE=STD.PAR.6711
PZGTOT_MODE=STD.PAR.6712
;PZREQ_MODE=STD.PAR.6713
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
;gestione invio pezzi in blocco
ENABLE_SEND_PZC_BLOCK=TRUE
MIN_SEND_PZC_BLOCK=0
MAX_SEND_PZC_BLOCK=100
[BRANCH]
NAME=master