INI

;Configurazione IOB-WIN
[IOB]
CNCTYPE=FANUC
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=DMG MORI Gildemeister
MODEL=SPRINT-32-5
[CNC]
; DMG MORI (IOT ENABLED)
IP=192.168.0.12
PORT=19000
;PORT=8193
GETPRGNAME=true
[SERVER]
MPIP=http://192.168.1.7
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
;schema elettrico (203 pg):
;1) le lampade e i colori (pag 7 di 203, Y1.0 --> Y1.3)
;2) modo auto (6 di 203, X7.2)
;3) porte (19 di 203, X8.6)
;4) allarme (61 di 203, X10.5) e guasto (61 di 203, X10.3 / X10.4)
;
;lista segnali (12 pg)
;5a) emergenza ch1 (spero vada bene) --> pag 3 di 12, X8.4
;5b) emergenza ch1 --> pg 8 di 12, Y7.0
;6) prog in RUN Y5.0 (pag 6 di 12)
[MEMORY]
AREAG_SIZE=48
AREAR_SIZE=0
AREAX_SIZE=8
AREAY_SIZE=16
; Red: Y1.1 | Yellow: Y1.2 | Green Y1.3 | All DoorsClosed: Y4.0 (X5.1) | ..........WrkZone Y8.7 | PZ richiesti: D.7960.DW - PZ prodotti: D.7964.DW
;BIT0=CONN
BIT1=Y1.3
BIT2=PZCOUNT.D.7964.DW
BIT3=Y1.1
BIT4=Y1.2
AREAD_START=0
AREAD_SIZE=9999
AREAR_START=0
AREAR_SIZE=64
AREAX_START=0
AREAX_SIZE=64
AREAY_START=0
AREAY_SIZE=64
PAR_START=6711
PAR_SIZE=3
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1990 --> 7960, 1991 --> 7964)
PZCOUNT_MODE=STD.D.7964.DW
;PZ_CAD_MADDR=???; cad
;PZ_REQ_MADDR=1990; pz richiesti (DW)
;PZ_DONE_MADDR=1991; pz fatti (DW)
;PZ_GTOT_MADDR=???; pz tot macchina
ENABLE_PZ_RESET=TRUE
ENABLE_PZ_RESET_stopSetup=TRUE
[BRANCH]
NAME=develop