;Configurazione IOB-WIN
[IOB]
;Macchina preriscaldo barre per Valvital
CNCTYPE=SIEMENS_LASCO
PING_MS_TIMEOUT=500
[MACHINE]
VENDOR=LASCP
MODEL=PRESSA_3150
[CNC]
;REAL PLC: OK!!!
IP=192.168.10.30
; PN/PN Coupler
;IP=192.168.214.22
CPUTYPE=S71500
RACK=0
SLOT=0
;CPUTYPE=S7300
;RACK=0
;SLOT=2
[SERVER]
MPIP=http://192.168.214.4
MPURL=/MP/IO
CMDBASE=/IOB/input/
CMDFLOG=/IOB/flog/
CMDALIVE=/IOB
CMDENABLED=/IOB/enabled/
CMDADV1=?valore=
CMDREBO=/sendReboot.aspx?idxMacchina=
[MEMORY]
ADDR_READ=DB1001.DBB0
ADDR_WRITE=DB1002.DBB0
SIZE_READ=60
SIZE_WRITE=60
;BIT0=CONN
;BIT1=DB60.DBB1
;BIT2=PZCOUNT.STD.DB700.DBW22
;BIT3=DB60.DBB3
;BIT4=DB60.DBB4
[BLINK]
;MAX_COUNTER_BLINK = 30
MAX_COUNTER_BLINK = 15
;bit0 = 0
;bit1 = 0
;bit2 = 1
;bit3 = 1
;bit4 = 1
;bit5 = 0
;bit6 = 0
;bit7 = 0
BLINK_FILT=0
;BLINK_FILT=28
[OPTPAR]
NO_PING=false
;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice
; attenzione memoria sempre base BYTE (1604 DW --> 6416...)
PZCOUNT_MODE=STD.DB1001.DBDW2
DISABLE_PZCOUNT=TRUE
ENABLE_DYN_DATA=TRUE
FORCE_DYN_DATA=TRUE
TSVC_RamPosition=MAX:5
TSVC_LowerEjectorPosition=MAX:5
TSVC_UpperTool=MAX:5
TSVC_TempMainMotorU=MAX:5
TSVC_TempMainMotorV=MAX:5
TSVC_TempMainMotorW=MAX:5
TSVC_TempSpindleNut=MAX:5
TSVC_TempMotoModule=MAX:5
TSVC_TempOilCirculation=MAX:5
TSVC_TempHydraulicUnit=MAX:5
TSVC_PressHydraulicPump=MAX:5
TSVC_PressHydraulicAccumulator=MAX:5
TSVC_PressCounterforceOil=MAX:5
TSVC_PressCounterforceGas=MAX:5
TSVC_ForcePressureActual=MAX:5
TSVC_ForceOnBushing=MAX:5
[BRANCH]
NAME=master