diff --git a/IOB-MAN/App.config b/IOB-MAN/App.config
index 1416f02c..02dc44ed 100644
--- a/IOB-MAN/App.config
+++ b/IOB-MAN/App.config
@@ -5,7 +5,8 @@
-
+
+
+
\ No newline at end of file
diff --git a/IOB-MAN/IOB-MAN.csproj b/IOB-MAN/IOB-MAN.csproj
index 1ea31674..7f92fa24 100644
--- a/IOB-MAN/IOB-MAN.csproj
+++ b/IOB-MAN/IOB-MAN.csproj
@@ -32,9 +32,16 @@
4
+
+ ..\packages\NLog.4.6.8\lib\net45\NLog.dll
+
+
+
+
+
@@ -68,6 +75,16 @@
True
Resources.resx
+
+ Always
+
+
+ PreserveNewest
+
+
+ Designer
+
+
SettingsSingleFileGenerator
Settings.Designer.cs
diff --git a/IOB-MAN/IOBManPanel.cs b/IOB-MAN/IOBManPanel.cs
index 8c312569..58e97ecf 100644
--- a/IOB-MAN/IOBManPanel.cs
+++ b/IOB-MAN/IOBManPanel.cs
@@ -11,7 +11,7 @@ namespace IOB_MAN
///
/// Elenco ARGS (uno per child da avviare)
///
- public List IobManList = new List();
+ public List ArgsList = new List();
///
/// Binding source degli elementi gestiti..
///
@@ -29,6 +29,7 @@ namespace IOB_MAN
private void myInit()
{
+ utils.lgInfo("Starting App");
// gestione eventi binding source
ElencoIOB.AddingNew += ElencoIOB_AddingNew;
ElencoIOB.ListChanged += ElencoIOB_ListChanged;
@@ -40,25 +41,28 @@ namespace IOB_MAN
{
TargetExe = string.Format(@"{0}\Test.bat", Application.StartupPath);
}
- string ArgsList = utils.CRS("ArgsList");
- if (string.IsNullOrEmpty(ArgsList))
+ utils.lgInfo($"Target exe: {TargetExe}");
+ string ArgsString = utils.CRS("ArgsList");
+ utils.lgInfo($"Args found: {ArgsString}");
+ if (string.IsNullOrEmpty(ArgsString))
{
var rand = new Random();
- // FAKE!! ne creo rand (5-15) di default...
+ // ne creo rand (5-15) di default...
for (int i = 0; i < rand.Next(5, 15); i++)
{
- IobManList.Add("127.0.0.1");
+ ArgsList.Add("127.0.0.1");
}
}
else
{
- var elenco = ArgsList.Split(',');
+ var elenco = ArgsString.Split(',');
foreach (var item in elenco)
{
- IobManList.Add(item);
+ ArgsList.Add(item);
}
}
MainTimer.Start();
+ utils.lgInfo("Timer started");
}
private void ElencoIOB_ListChanged(object sender, System.ComponentModel.ListChangedEventArgs e)
@@ -95,7 +99,7 @@ namespace IOB_MAN
{
//Process childProc = new Process();
ProcessStartInfo psi = null;
- foreach (var item in IobManList)
+ foreach (var item in ArgsList)
{
// da testare x aprire chiudere risorsa...
psi = new ProcessStartInfo
@@ -110,12 +114,14 @@ namespace IOB_MAN
// accodo nuovo IOB...
iobAdapt newIob = new iobAdapt();
DateTime adesso = DateTime.Now;
- newIob.CodIOB = p.Id.ToString();
+ newIob.CodIOB = item;
newIob.startTime = adesso;
newIob.pID = p.Id;
newIob.isRunning = true;
// aggiungo a datasource
ElencoIOB.Add(newIob);
+
+ utils.lgInfo($"Avviato child process per {item} | pid: {p.Id}");
}
diff --git a/IOB-MAN/NLog.config b/IOB-MAN/NLog.config
new file mode 100644
index 00000000..93055638
--- /dev/null
+++ b/IOB-MAN/NLog.config
@@ -0,0 +1,83 @@
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
diff --git a/IOB-MAN/NLog.xsd b/IOB-MAN/NLog.xsd
new file mode 100644
index 00000000..16d888c8
--- /dev/null
+++ b/IOB-MAN/NLog.xsd
@@ -0,0 +1,3556 @@
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Watch config file for changes and reload automatically.
+
+
+
+
+ Print internal NLog messages to the console. Default value is: false
+
+
+
+
+ Print internal NLog messages to the console error output. Default value is: false
+
+
+
+
+ Write internal NLog messages to the specified file.
+
+
+
+
+ Log level threshold for internal log messages. Default value is: Info.
+
+
+
+
+ Global log level threshold for application log messages. Messages below this level won't be logged.
+
+
+
+
+ Throw an exception when there is an internal error. Default value is: false. Not recommend to set to true in production!
+
+
+
+
+ Throw an exception when there is a configuration error. If not set, determined by throwExceptions.
+
+
+
+
+ Gets or sets a value indicating whether Variables should be kept on configuration reload. Default value is: false.
+
+
+
+
+ Write internal NLog messages to the System.Diagnostics.Trace. Default value is: false.
+
+
+
+
+ Write timestamps for internal NLog messages. Default value is: true.
+
+
+
+
+ Use InvariantCulture as default culture instead of CurrentCulture. Default value is: false.
+
+
+
+
+ Perform message template parsing and formatting of LogEvent messages (true = Always, false = Never, empty = Auto Detect). Default value is: empty.
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Make all targets within this section asynchronous (creates additional threads but the calling thread isn't blocked by any target writes).
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Prefix for targets/layout renderers/filters/conditions loaded from this assembly.
+
+
+
+
+ Load NLog extensions from the specified file (*.dll)
+
+
+
+
+ Load NLog extensions from the specified assembly. Assembly name should be fully qualified.
+
+
+
+
+
+
+
+
+
+ Name of the logger. May include wildcard characters ('*' or '?').
+
+
+
+
+ Comma separated list of levels that this rule matches.
+
+
+
+
+ Minimum level that this rule matches.
+
+
+
+
+ Maximum level that this rule matches.
+
+
+
+
+ Level that this rule matches.
+
+
+
+
+ Comma separated list of target names.
+
+
+
+
+ Ignore further rules if this one matches.
+
+
+
+
+ Rule identifier to allow rule lookup with Configuration.FindRuleByName and Configuration.RemoveRuleByName.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Default action if none of the filters match.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the file to be included. You could use * wildcard. The name is relative to the name of the current config file.
+
+
+
+
+ Ignore any errors in the include file.
+
+
+
+
+
+
+
+ Variable value. Note, the 'value' attribute has precedence over this one.
+
+
+
+
+
+ Variable name.
+
+
+
+
+ Variable value.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Number of log events that should be processed in a batch by the lazy writer thread.
+
+
+
+
+ Whether to use the locking queue, instead of a lock-free concurrent queue The locking queue is less concurrent when many logger threads, but reduces memory allocation
+
+
+
+
+ Limit of full s to write before yielding into Performance is better when writing many small batches, than writing a single large batch
+
+
+
+
+ Action to be taken when the lazy writer thread request queue count exceeds the set limit.
+
+
+
+
+ Limit on the number of requests in the lazy writer thread request queue.
+
+
+
+
+ Time in milliseconds to sleep between batches. (1 or less means trigger on new activity)
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Delay the flush until the LogEvent has been confirmed as written
+
+
+
+
+ Condition expression. Log events who meet this condition will cause a flush on the wrapped target.
+
+
+
+
+ Name of the target.
+
+
+
+
+ Only flush when LogEvent matches condition. Ignore explicit-flush, config-reload-flush and shutdown-flush
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Number of log events to be buffered.
+
+
+
+
+ Timeout (in milliseconds) after which the contents of buffer will be flushed if there's no write in the specified period of time. Use -1 to disable timed flushes.
+
+
+
+
+ Action to take if the buffer overflows.
+
+
+
+
+ Indicates whether to use sliding timeout.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Encoding to be used.
+
+
+
+
+ Instance of that is used to format log messages.
+
+
+
+
+ End of line value if a newline is appended at the end of log message .
+
+
+
+
+ Maximum message size in bytes.
+
+
+
+
+ Indicates whether to append newline at the end of log message.
+
+
+
+
+ Network address.
+
+
+
+
+ Size of the connection cache (number of connections which are kept alive).
+
+
+
+
+ Indicates whether to keep connection open whenever possible.
+
+
+
+
+ Maximum current connections. 0 = no maximum.
+
+
+
+
+ Action that should be taken if the will be more connections than .
+
+
+
+
+ Action that should be taken if the message is larger than maxMessageSize.
+
+
+
+
+ Get or set the SSL/TLS protocols. Default no SSL/TLS is used. Currently only implemented for TCP.
+
+
+
+
+ Maximum queue size.
+
+
+
+
+ The number of seconds a connection will remain idle before the first keep-alive probe is sent
+
+
+
+
+ NDLC item separator.
+
+
+
+
+ Indicates whether to include source info (file name and line number) in the information sent over the network.
+
+
+
+
+ Renderer for log4j:event logger-xml-attribute (Default ${logger})
+
+
+
+
+ Indicates whether to include NLog-specific extensions to log4j schema.
+
+
+
+
+ Indicates whether to include contents of the stack.
+
+
+
+
+ Indicates whether to include stack contents.
+
+
+
+
+ Indicates whether to include dictionary contents.
+
+
+
+
+ Indicates whether to include dictionary contents.
+
+
+
+
+ Indicates whether to include call site (class and method name) in the information sent over the network.
+
+
+
+
+ Option to include all properties from the log events
+
+
+
+
+ AppInfo field. By default it's the friendly name of the current AppDomain.
+
+
+
+
+ NDC item separator.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Layout that should be use to calculate the value for the parameter.
+
+
+
+
+ Viewer parameter name.
+
+
+
+
+ Whether an attribute with empty value should be included in the output
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Text to be rendered.
+
+
+
+
+ Header.
+
+
+
+
+ Footer.
+
+
+
+
+ Indicates whether to auto-check if the console is available. - Disables console writing if Environment.UserInteractive = False (Windows Service) - Disables console writing if Console Standard Input is not available (Non-Console-App)
+
+
+
+
+ Enables output using ANSI Color Codes
+
+
+
+
+ The encoding for writing messages to the .
+
+
+
+
+ Indicates whether the error stream (stderr) should be used instead of the output stream (stdout).
+
+
+
+
+ Indicates whether to auto-check if the console has been redirected to file - Disables coloring logic when System.Console.IsOutputRedirected = true
+
+
+
+
+ Indicates whether to use default row highlighting rules.
+
+
+
+
+ Indicates whether to auto-flush after
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Condition that must be met in order to set the specified foreground and background color.
+
+
+
+
+ Background color.
+
+
+
+
+ Foreground color.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Compile the ? This can improve the performance, but at the costs of more memory usage. If false, the Regex Cache is used.
+
+
+
+
+ Indicates whether to ignore case when comparing texts.
+
+
+
+
+ Regular expression to be matched. You must specify either text or regex.
+
+
+
+
+ Text to be matched. You must specify either text or regex.
+
+
+
+
+ Indicates whether to match whole words only.
+
+
+
+
+ Background color.
+
+
+
+
+ Foreground color.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Text to be rendered.
+
+
+
+
+ Header.
+
+
+
+
+ Footer.
+
+
+
+
+ Indicates whether to auto-check if the console is available - Disables console writing if Environment.UserInteractive = False (Windows Service) - Disables console writing if Console Standard Input is not available (Non-Console-App)
+
+
+
+
+ The encoding for writing messages to the .
+
+
+
+
+ Indicates whether to send the log messages to the standard error instead of the standard output.
+
+
+
+
+ Indicates whether to auto-flush after
+
+
+
+
+ Whether to enable batch writing using char[]-buffers, instead of using
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Obsolete - value will be ignored! The logging code always runs outside of transaction. Gets or sets a value indicating whether to use database transactions. Some data providers require this.
+
+
+
+
+ Database user name. If the ConnectionString is not provided this value will be used to construct the "User ID=" part of the connection string.
+
+
+
+
+ Name of the database provider.
+
+
+
+
+ Database password. If the ConnectionString is not provided this value will be used to construct the "Password=" part of the connection string.
+
+
+
+
+ Indicates whether to keep the database connection open between the log events.
+
+
+
+
+ Database name. If the ConnectionString is not provided this value will be used to construct the "Database=" part of the connection string.
+
+
+
+
+ Name of the connection string (as specified in <connectionStrings> configuration section.
+
+
+
+
+ Connection string. When provided, it overrides the values specified in DBHost, DBUserName, DBPassword, DBDatabase.
+
+
+
+
+ Database host name. If the ConnectionString is not provided this value will be used to construct the "Server=" part of the connection string.
+
+
+
+
+ Connection string using for installation and uninstallation. If not provided, regular ConnectionString is being used.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+ Text of the SQL command to be run on each log level.
+
+
+
+
+ Type of the SQL command to be run on each log level.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Type of the command.
+
+
+
+
+ Connection string to run the command against. If not provided, connection string from the target is used.
+
+
+
+
+ Indicates whether to ignore failures.
+
+
+
+
+ Command text.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Database parameter name.
+
+
+
+
+ Layout that should be use to calculate the value for the parameter.
+
+
+
+
+ Database parameter DbType.
+
+
+
+
+ Database parameter size.
+
+
+
+
+ Database parameter precision.
+
+
+
+
+ Database parameter scale.
+
+
+
+
+ Type of the parameter.
+
+
+
+
+ Convert format of the database parameter value .
+
+
+
+
+ Culture used for parsing parameter string-value for type-conversion
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Text to be rendered.
+
+
+
+
+ Header.
+
+
+
+
+ Footer.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Layout that renders event Category.
+
+
+
+
+ Optional entry type. When not set, or when not convertible to then determined by
+
+
+
+
+ Layout that renders event ID.
+
+
+
+
+ Name of the Event Log to write to. This can be System, Application or any user-defined name.
+
+
+
+
+ Name of the machine on which Event Log service is running.
+
+
+
+
+ Maximum Event log size in kilobytes.
+
+
+
+
+ Message length limit to write to the Event Log.
+
+
+
+
+ Value to be used as the event Source.
+
+
+
+
+ Action to take if the message is larger than the option.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Indicates whether to return to the first target after any successful write.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Text to be rendered.
+
+
+
+
+ Header.
+
+
+
+
+ Footer.
+
+
+
+
+ File encoding.
+
+
+
+
+ Line ending mode.
+
+
+
+
+ Indicates whether to compress archive files into the zip archive format.
+
+
+
+
+ Way file archives are numbered.
+
+
+
+
+ Name of the file to be used for an archive.
+
+
+
+
+ Is the an absolute or relative path?
+
+
+
+
+ Indicates whether to automatically archive log files every time the specified time passes.
+
+
+
+
+ Size in bytes above which log files will be automatically archived. Warning: combining this with isn't supported. We cannot create multiple archive files, if they should have the same name. Choose:
+
+
+
+
+ Maximum number of archive files that should be kept.
+
+
+
+
+ Indicates whether the footer should be written only when the file is archived.
+
+
+
+
+ Maximum number of log file names that should be stored as existing.
+
+
+
+
+ Is the an absolute or relative path?
+
+
+
+
+ Gets or set a value indicating whether a managed file stream is forced, instead of using the native implementation.
+
+
+
+
+ Indicates whether file creation calls should be synchronized by a system global mutex.
+
+
+
+
+ Indicates whether to replace file contents on each write instead of appending log message at the end.
+
+
+
+
+ Indicates whether to write BOM (byte order mark) in created files
+
+
+
+
+ Indicates whether to enable log file(s) to be deleted.
+
+
+
+
+ Name of the file to write to.
+
+
+
+
+ Value specifying the date format to use when archiving files.
+
+
+
+
+ Indicates whether to archive old log file on startup.
+
+
+
+
+ Cleanup invalid values in a filename, e.g. slashes in a filename. If set to true, this can impact the performance of massive writes. If set to false, nothing gets written when the filename is wrong.
+
+
+
+
+ Indicates whether to create directories if they do not exist.
+
+
+
+
+ Indicates whether to delete old log file on startup.
+
+
+
+
+ File attributes (Windows only).
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+ Indicates whether concurrent writes to the log file by multiple processes on different network hosts.
+
+
+
+
+ Maximum number of seconds that files are kept open. If this number is negative the files are not automatically closed after a period of inactivity.
+
+
+
+
+ Number of files to be kept open. Setting this to a higher value may improve performance in a situation where a single File target is writing to many files (such as splitting by level or by logger).
+
+
+
+
+ Indicates whether to keep log file open instead of opening and closing it on each logging event.
+
+
+
+
+ Whether or not this target should just discard all data that its asked to write. Mostly used for when testing NLog Stack except final write
+
+
+
+
+ Indicates whether concurrent writes to the log file by multiple processes on the same host.
+
+
+
+
+ Number of times the write is appended on the file before NLog discards the log message.
+
+
+
+
+ Delay in milliseconds to wait before attempting to write to the file again.
+
+
+
+
+ Log file buffer size in bytes.
+
+
+
+
+ Maximum number of seconds before open files are flushed. If this number is negative or zero the files are not flushed by timer.
+
+
+
+
+ Indicates whether to automatically flush the file buffers after each log message.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Condition expression. Log events who meet this condition will be forwarded to the wrapped target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Windows domain name to change context to.
+
+
+
+
+ Required impersonation level.
+
+
+
+
+ Type of the logon provider.
+
+
+
+
+ Logon Type.
+
+
+
+
+ User account password.
+
+
+
+
+ Indicates whether to revert to the credentials of the process instead of impersonating another user.
+
+
+
+
+ Username to change context to.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Interval in which messages will be written up to the number of messages.
+
+
+
+
+ Maximum allowed number of messages written per .
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Endpoint address.
+
+
+
+
+ Name of the endpoint configuration in WCF configuration file.
+
+
+
+
+ Indicates whether to use a WCF service contract that is one way (fire and forget) or two way (request-reply)
+
+
+
+
+ Client ID.
+
+
+
+
+ Indicates whether to include per-event properties in the payload sent to the server.
+
+
+
+
+ Indicates whether to use binary message encoding.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Layout that should be use to calculate the value for the parameter.
+
+
+
+
+ Name of the parameter.
+
+
+
+
+ Type of the parameter.
+
+
+
+
+ Type of the parameter. Obsolete alias for
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Text to be rendered.
+
+
+
+
+ Header.
+
+
+
+
+ Footer.
+
+
+
+
+ Indicates whether NewLine characters in the body should be replaced with tags.
+
+
+
+
+ Priority used for sending mails.
+
+
+
+
+ Encoding to be used for sending e-mail.
+
+
+
+
+ BCC email addresses separated by semicolons (e.g. john@domain.com;jane@domain.com).
+
+
+
+
+ CC email addresses separated by semicolons (e.g. john@domain.com;jane@domain.com).
+
+
+
+
+ Indicates whether to add new lines between log entries.
+
+
+
+
+ Indicates whether to send message as HTML instead of plain text.
+
+
+
+
+ Sender's email address (e.g. joe@domain.com).
+
+
+
+
+ Mail message body (repeated for each log message send in one mail).
+
+
+
+
+ Mail subject.
+
+
+
+
+ Recipients' email addresses separated by semicolons (e.g. john@domain.com;jane@domain.com).
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+ Indicates the SMTP client timeout.
+
+
+
+
+ SMTP Server to be used for sending.
+
+
+
+
+ SMTP Authentication mode.
+
+
+
+
+ Username used to connect to SMTP server (used when SmtpAuthentication is set to "basic").
+
+
+
+
+ Password used to authenticate against SMTP server (used when SmtpAuthentication is set to "basic").
+
+
+
+
+ Indicates whether SSL (secure sockets layer) should be used when communicating with SMTP server.
+
+
+
+
+ Port number that SMTP Server is listening on.
+
+
+
+
+ Indicates whether the default Settings from System.Net.MailSettings should be used.
+
+
+
+
+ Folder where applications save mail messages to be processed by the local SMTP server.
+
+
+
+
+ Specifies how outgoing email messages will be handled.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Max number of items to have in memory
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Class name.
+
+
+
+
+ Method name. The method must be public and static. Use the AssemblyQualifiedName , https://msdn.microsoft.com/en-us/library/system.type.assemblyqualifiedname(v=vs.110).aspx e.g.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Encoding to be used.
+
+
+
+
+ End of line value if a newline is appended at the end of log message .
+
+
+
+
+ Maximum message size in bytes.
+
+
+
+
+ Indicates whether to append newline at the end of log message.
+
+
+
+
+ Network address.
+
+
+
+
+ Size of the connection cache (number of connections which are kept alive).
+
+
+
+
+ Indicates whether to keep connection open whenever possible.
+
+
+
+
+ Maximum current connections. 0 = no maximum.
+
+
+
+
+ Maximum queue size.
+
+
+
+
+ Action that should be taken if the will be more connections than .
+
+
+
+
+ Action that should be taken if the message is larger than maxMessageSize.
+
+
+
+
+ Get or set the SSL/TLS protocols. Default no SSL/TLS is used. Currently only implemented for TCP.
+
+
+
+
+ The number of seconds a connection will remain idle before the first keep-alive probe is sent
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Encoding to be used.
+
+
+
+
+ Instance of that is used to format log messages.
+
+
+
+
+ End of line value if a newline is appended at the end of log message .
+
+
+
+
+ Maximum message size in bytes.
+
+
+
+
+ Indicates whether to append newline at the end of log message.
+
+
+
+
+ Network address.
+
+
+
+
+ Size of the connection cache (number of connections which are kept alive).
+
+
+
+
+ Indicates whether to keep connection open whenever possible.
+
+
+
+
+ Maximum current connections. 0 = no maximum.
+
+
+
+
+ Action that should be taken if the will be more connections than .
+
+
+
+
+ Action that should be taken if the message is larger than maxMessageSize.
+
+
+
+
+ Get or set the SSL/TLS protocols. Default no SSL/TLS is used. Currently only implemented for TCP.
+
+
+
+
+ Maximum queue size.
+
+
+
+
+ The number of seconds a connection will remain idle before the first keep-alive probe is sent
+
+
+
+
+ NDLC item separator.
+
+
+
+
+ Indicates whether to include source info (file name and line number) in the information sent over the network.
+
+
+
+
+ Renderer for log4j:event logger-xml-attribute (Default ${logger})
+
+
+
+
+ Indicates whether to include NLog-specific extensions to log4j schema.
+
+
+
+
+ Indicates whether to include contents of the stack.
+
+
+
+
+ Indicates whether to include stack contents.
+
+
+
+
+ Indicates whether to include dictionary contents.
+
+
+
+
+ Indicates whether to include dictionary contents.
+
+
+
+
+ Indicates whether to include call site (class and method name) in the information sent over the network.
+
+
+
+
+ Option to include all properties from the log events
+
+
+
+
+ AppInfo field. By default it's the friendly name of the current AppDomain.
+
+
+
+
+ NDC item separator.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Indicates whether to perform layout calculation.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Indicates whether performance counter should be automatically created.
+
+
+
+
+ Name of the performance counter category.
+
+
+
+
+ Counter help text.
+
+
+
+
+ Name of the performance counter.
+
+
+
+
+ Performance counter type.
+
+
+
+
+ The value by which to increment the counter.
+
+
+
+
+ Performance counter instance name.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Default filter to be applied when no specific rule matches.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+ Condition to be tested.
+
+
+
+
+ Resulting filter to be applied when the condition matches.
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+ Number of times to repeat each log message.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+ Number of retries that should be attempted on the wrapped target in case of a failure.
+
+
+
+
+ Time to wait between retries in milliseconds.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Layout used to format log messages.
+
+
+
+
+ Always use independent of
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Name of the target.
+
+
+
+
+ Target supports reuse of internal buffers, and doesn't have to constantly allocate new buffers Required for legacy NLog-targets, that expects buffers to remain stable after Write-method exit
+
+
+
+
+ Should we include the BOM (Byte-order-mark) for UTF? Influences the property. This will only work for UTF-8.
+
+
+
+
+ Web service method name. Only used with Soap.
+
+
+
+
+ Web service namespace. Only used with Soap.
+
+
+
+
+ Protocol to be used when calling web service.
+
+
+
+
+ Custom proxy address, include port separated by a colon
+
+
+
+
+ Encoding.
+
+
+
+
+ Web service URL.
+
+
+
+
+ Value whether escaping be done according to the old NLog style (Very non-standard)
+
+
+
+
+ Value whether escaping be done according to Rfc3986 (Supports Internationalized Resource Identifiers - IRIs)
+
+
+
+
+ Indicates whether to pre-authenticate the HttpWebRequest (Requires 'Authorization' in parameters)
+
+
+
+
+ Name of the root XML element, if POST of XML document chosen. If so, this property must not be null. (see and ).
+
+
+
+
+ (optional) root namespace of the XML document, if POST of XML document chosen. (see and ).
+
+
+
+
+ Proxy configuration when calling web service
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Footer layout.
+
+
+
+
+ Header layout.
+
+
+
+
+ Body layout (can be repeated multiple times).
+
+
+
+
+ Custom column delimiter value (valid when ColumnDelimiter is set to 'Custom').
+
+
+
+
+ Column delimiter.
+
+
+
+
+ Quote Character.
+
+
+
+
+ Quoting mode.
+
+
+
+
+ Indicates whether CVS should include header.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Layout of the column.
+
+
+
+
+ Name of the column.
+
+
+
+
+ Override of Quoting mode
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ List of property names to exclude when is true
+
+
+
+
+ Option to include all properties from the log event (as JSON)
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ How far should the JSON serializer follow object references before backing off
+
+
+
+
+ Option to render the empty object value {}
+
+
+
+
+ Option to suppress the extra spaces in the output json
+
+
+
+
+ Should forward slashes be escaped? If true, / will be converted to \/
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Layout that will be rendered as the attribute's value.
+
+
+
+
+ Name of the attribute.
+
+
+
+
+ Determines whether or not this attribute will be Json encoded.
+
+
+
+
+ Indicates whether to escape non-ascii characters
+
+
+
+
+ Whether an attribute with empty value should be included in the output
+
+
+
+
+ Should forward slashes be escaped? If true, / will be converted to \/
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Footer layout.
+
+
+
+
+ Header layout.
+
+
+
+
+ Body layout (can be repeated multiple times).
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Option to include all properties from the log events
+
+
+
+
+ Indicates whether to include call site (class and method name) in the information sent over the network.
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ Indicates whether to include contents of the stack.
+
+
+
+
+ Indicates whether to include contents of the stack.
+
+
+
+
+ Indicates whether to include source info (file name and line number) in the information sent over the network.
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Layout text.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ List of property names to exclude when is true
+
+
+
+
+ Option to include all properties from the log event (as XML)
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ How far should the XML serializer follow object references before backing off
+
+
+
+
+ XML element name to use for rendering IList-collections items
+
+
+
+
+ XML attribute name to use when rendering property-key When null (or empty) then key-attribute is not included
+
+
+
+
+ XML element name to use when rendering properties
+
+
+
+
+ XML attribute name to use when rendering property-value When null (or empty) then value-attribute is not included and value is formatted as XML-element-value
+
+
+
+
+ Name of the root XML element
+
+
+
+
+ Value inside the root XML element
+
+
+
+
+ Whether a ElementValue with empty value should be included in the output
+
+
+
+
+ Auto indent and create new lines
+
+
+
+
+ Determines whether or not this attribute will be Xml encoded.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Layout that will be rendered as the attribute's value.
+
+
+
+
+ Name of the attribute.
+
+
+
+
+ Determines whether or not this attribute will be Xml encoded.
+
+
+
+
+ Whether an attribute with empty value should be included in the output
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Determines whether or not this attribute will be Xml encoded.
+
+
+
+
+ Name of the element
+
+
+
+
+ Value inside the element
+
+
+
+
+ Whether a ElementValue with empty value should be included in the output
+
+
+
+
+ Auto indent and create new lines
+
+
+
+
+ List of property names to exclude when is true
+
+
+
+
+ Option to include all properties from the log event (as XML)
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ Indicates whether to include contents of the dictionary.
+
+
+
+
+ How far should the XML serializer follow object references before backing off
+
+
+
+
+ XML element name to use for rendering IList-collections items
+
+
+
+
+ XML attribute name to use when rendering property-key When null (or empty) then key-attribute is not included
+
+
+
+
+ XML element name to use when rendering properties
+
+
+
+
+ XML attribute name to use when rendering property-value When null (or empty) then value-attribute is not included and value is formatted as XML-element-value
+
+
+
+
+
+
+
+
+
+
+
+
+ Action to be taken when filter matches.
+
+
+
+
+ Condition expression.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Action to be taken when filter matches.
+
+
+
+
+ Indicates whether to ignore case when comparing strings.
+
+
+
+
+ Layout to be used to filter log messages.
+
+
+
+
+ Substring to be matched.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Action to be taken when filter matches.
+
+
+
+
+ String to compare the layout to.
+
+
+
+
+ Indicates whether to ignore case when comparing strings.
+
+
+
+
+ Layout to be used to filter log messages.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Action to be taken when filter matches.
+
+
+
+
+ Indicates whether to ignore case when comparing strings.
+
+
+
+
+ Layout to be used to filter log messages.
+
+
+
+
+ Substring to be matched.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Action to be taken when filter matches.
+
+
+
+
+ String to compare the layout to.
+
+
+
+
+ Indicates whether to ignore case when comparing strings.
+
+
+
+
+ Layout to be used to filter log messages.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Action to be taken when filter matches.
+
+
+
+
+ Default number of unique filter values to expect, will automatically increase if needed
+
+
+
+
+ Applies the configured action to the initial logevent that starts the timeout period. Used to configure that it should ignore all events until timeout.
+
+
+
+
+ Layout to be used to filter log messages.
+
+
+
+
+ Max number of unique filter values to expect simultaneously
+
+
+
+
+ Max length of filter values, will truncate if above limit
+
+
+
+
+ How long before a filter expires, and logging is accepted again
+
+
+
+
+ Default buffer size for the internal buffers
+
+
+
+
+ Reuse internal buffers, and doesn't have to constantly allocate new buffers
+
+
+
+
+ Append FilterCount to the when an event is no longer filtered
+
+
+
+
+ Insert FilterCount value into when an event is no longer filtered
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
\ No newline at end of file
diff --git a/IOB-MAN/logs/.placeholder b/IOB-MAN/logs/.placeholder
new file mode 100644
index 00000000..5f282702
--- /dev/null
+++ b/IOB-MAN/logs/.placeholder
@@ -0,0 +1 @@
+
\ No newline at end of file
diff --git a/IOB-MAN/packages.config b/IOB-MAN/packages.config
new file mode 100644
index 00000000..44be8695
--- /dev/null
+++ b/IOB-MAN/packages.config
@@ -0,0 +1,6 @@
+
+
+
+
+
+
\ No newline at end of file
diff --git a/IOB-MAN/utils.cs b/IOB-MAN/utils.cs
index 81a8af52..3b9c0046 100644
--- a/IOB-MAN/utils.cs
+++ b/IOB-MAN/utils.cs
@@ -1,4 +1,5 @@
+using NLog;
using System;
using System.Collections.Generic;
using System.Configuration;
@@ -8,6 +9,33 @@ namespace IOB_MAN
{
public class utils
{
+ #region logging
+
+ ///
+ /// Classe logger
+ ///
+ public static Logger lg = LogManager.GetCurrentClassLogger();
+ ///
+ /// Effettua logging INFO corretto impostanto anche la variabile IOB prima di scrivere...
+ ///
+ ///
+ public static void lgInfo(string txt2log)
+ {
+ lg.Factory.Configuration.Variables["codApp"] = "IOB-MAN";
+ lg.Info(txt2log);
+ }
+ ///
+ /// Effettua logging ERROR corretto impostanto anche la variabile IOB prima di scrivere...
+ ///
+ ///
+ public static void lgError(string txt2log)
+ {
+ lg.Factory.Configuration.Variables["codApp"] = "IOB-MAN";
+ lg.Error(txt2log);
+ }
+
+ #endregion
+
///
/// Helper formattazione durata human readable
///
diff --git a/Jenkinsfile b/Jenkinsfile
index 53b27653..3df230c4 100644
--- a/Jenkinsfile
+++ b/Jenkinsfile
@@ -16,9 +16,9 @@ pipeline {
/* calcolo numero versione... diverso x branch MASTER/DEVELOP */
script {
- withEnv(['NEXT_BUILD_NUMBER=611']) {
- // env.versionNumber = VersionNumber(versionNumberString : '2.7.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true)
- env.versionNumber = VersionNumber(versionNumberString : '2.7.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true, overrideBuildsAllTime: '${NEXT_BUILD_NUMBER}')
+ withEnv(['NEXT_BUILD_NUMBER=613']) {
+ // env.versionNumber = VersionNumber(versionNumberString : '3.0.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true)
+ env.versionNumber = VersionNumber(versionNumberString : '3.0.${BUILD_DATE_FORMATTED, "yyMM"}.${BUILDS_ALL_TIME}', projectStartDate : '2006-01-01', skipFailedBuilds: true, overrideBuildsAllTime: '${NEXT_BUILD_NUMBER}')
env.APP_NAME = 'MAPO-IOB-WIN'
}
}