From 6f71dac8b1efc22bbcc7fe594b72558b6b54c4e9 Mon Sep 17 00:00:00 2001 From: "Samuele E. Locatelli" Date: Fri, 25 Sep 2020 14:47:42 +0200 Subject: [PATCH] Fix conf in prod x Valvital --- IOB-WIN/DATA/CONF/VL20.ini | 8 +-- IOB-WIN/DATA/CONF/VL20.json | 2 +- IOB-WIN/DATA/CONF/VL21.ini | 5 +- IOB-WIN/DATA/CONF/VL22.ini | 3 +- IOB-WIN/DATA/CONF/VL22.json | 108 ++++++++++++++++++------------------ IOB-WIN/DATA/CONF/VL23.ini | 4 +- IOB-WIN/DATA/CONF/VL24.ini | 3 +- IOB-WIN/DATA/CONF/VL24.json | 2 +- IOB-WIN/DATA/CONF/VL25.ini | 4 +- IOB-WIN/DATA/CONF/VL25.json | 6 +- IOB-WIN/DATA/CONF/VL26.ini | 9 +-- 11 files changed, 77 insertions(+), 77 deletions(-) diff --git a/IOB-WIN/DATA/CONF/VL20.ini b/IOB-WIN/DATA/CONF/VL20.ini index 24d1bf29..910ef2b2 100644 --- a/IOB-WIN/DATA/CONF/VL20.ini +++ b/IOB-WIN/DATA/CONF/VL20.ini @@ -1,6 +1,6 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] -;Macchina preriscaldo barre per Valvital +;Macchina tempra induzione officina Valvital CNCTYPE=SIEMENS_SAET PING_MS_TIMEOUT=500 @@ -52,13 +52,13 @@ BLINK_FILT=0 ;BLINK_FILT=28 [OPTPAR] -;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice +;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice PZCOUNT_MODE=STD.DB1275.DBDW4 DISABLE_PZCOUNT=FALSE ENABLE_SEND_PZC_BLOCK=TRUE MIN_SEND_PZC_BLOCK=0 MAX_SEND_PZC_BLOCK=100 -;GESTIONE DATI DYN +; GEST DATI DYN ENABLE_DYN_DATA=TRUE FORCE_DYN_DATA=TRUE diff --git a/IOB-WIN/DATA/CONF/VL20.json b/IOB-WIN/DATA/CONF/VL20.json index 32b44e07..d7b01aa7 100644 --- a/IOB-WIN/DATA/CONF/VL20.json +++ b/IOB-WIN/DATA/CONF/VL20.json @@ -20,7 +20,7 @@ "name": "setPzComm", "description": "Qty", "memAddr": "DB1275.DBB144", - "tipoMem": "Int", + "tipoMem": "DInt", "index": 144, "size": 4 } diff --git a/IOB-WIN/DATA/CONF/VL21.ini b/IOB-WIN/DATA/CONF/VL21.ini index f89acd01..7212ed8e 100644 --- a/IOB-WIN/DATA/CONF/VL21.ini +++ b/IOB-WIN/DATA/CONF/VL21.ini @@ -1,4 +1,4 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] ;Macchina DENTATRICE per Valvital CNCTYPE=SIEMENS_COMUR @@ -53,12 +53,13 @@ BLINK_FILT=0 [OPTPAR] ;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice +; attenzione memoria sempre base BYTE (1604 DW --> 6416...) PZCOUNT_MODE=SPEC.DB111.DBDW24 DISABLE_PZCOUNT=FALSE ENABLE_SEND_PZC_BLOCK=TRUE MIN_SEND_PZC_BLOCK=0 MAX_SEND_PZC_BLOCK=100 -;GESTIONE DATI DYN +; GEST DATI DYN ENABLE_DYN_DATA=TRUE FORCE_DYN_DATA=TRUE diff --git a/IOB-WIN/DATA/CONF/VL22.ini b/IOB-WIN/DATA/CONF/VL22.ini index 91342b21..567d968e 100644 --- a/IOB-WIN/DATA/CONF/VL22.ini +++ b/IOB-WIN/DATA/CONF/VL22.ini @@ -1,4 +1,4 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] ;Macchina preriscaldo barre per Valvital CNCTYPE=SIEMENS_LASCO @@ -59,7 +59,6 @@ BLINK_FILT=0 [OPTPAR] NO_PING=false ;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice -; attenzione memoria sempre base BYTE (1604 DW --> 6416...) PZCOUNT_MODE=STD.DB1001.DBDW2 DISABLE_PZCOUNT=FALSE ENABLE_SEND_PZC_BLOCK=TRUE diff --git a/IOB-WIN/DATA/CONF/VL22.json b/IOB-WIN/DATA/CONF/VL22.json index ee83f328..b20eb79f 100644 --- a/IOB-WIN/DATA/CONF/VL22.json +++ b/IOB-WIN/DATA/CONF/VL22.json @@ -26,59 +26,59 @@ } }, "mMapRead": { - "RamPosition": { - "name": "RamPosition", - "tipoMem": "Int", - "index": 18, - "size": 2, - "func": "MAX", - "period": 60, - "factor": 10 - }, - "LowerEjectorPosition": { - "name": "LowerEjectorPosition", - "tipoMem": "Int", - "index": 20, - "size": 2, - "func": "MAX", - "period": 60, - "factor": 10 - }, - "UpperTool": { - "name": "UpperTool", - "tipoMem": "Int", - "index": 22, - "size": 2, - "func": "MAX", - "period": 60, - "factor": 10 - }, - "TempMainMotorU": { - "name": "TempMainMotorU", - "tipoMem": "Int", - "index": 24, - "size": 2, - "func": "MAX", - "period": 60, - "factor": 1 - }, - "TempMainMotorV": { - "name": "TempMainMotorV", - "tipoMem": "Int", - "index": 26, - "size": 2, - "func": "MAX", - "period": 60, - "factor": 1 - }, - "TempMainMotorW": { - "name": "TempMainMotorW", - "tipoMem": "Int", - "index": 28, - "size": 2, - "func": "MAX", - "period": 60, - "factor": 1 - } + //"RamPosition": { + // "name": "RamPosition", + // "tipoMem": "Int", + // "index": 18, + // "size": 2, + // "func": "MAX", + // "period": 60, + // "factor": 10 + //}, + //"LowerEjectorPosition": { + // "name": "LowerEjectorPosition", + // "tipoMem": "Int", + // "index": 20, + // "size": 2, + // "func": "MAX", + // "period": 60, + // "factor": 10 + //}, + //"UpperTool": { + // "name": "UpperTool", + // "tipoMem": "Int", + // "index": 22, + // "size": 2, + // "func": "MAX", + // "period": 60, + // "factor": 10 + //}, + //"TempMainMotorU": { + // "name": "TempMainMotorU", + // "tipoMem": "Int", + // "index": 24, + // "size": 2, + // "func": "MAX", + // "period": 60, + // "factor": 1 + //}, + //"TempMainMotorV": { + // "name": "TempMainMotorV", + // "tipoMem": "Int", + // "index": 26, + // "size": 2, + // "func": "MAX", + // "period": 60, + // "factor": 1 + //}, + //"TempMainMotorW": { + // "name": "TempMainMotorW", + // "tipoMem": "Int", + // "index": 28, + // "size": 2, + // "func": "MAX", + // "period": 60, + // "factor": 1 + //} } } \ No newline at end of file diff --git a/IOB-WIN/DATA/CONF/VL23.ini b/IOB-WIN/DATA/CONF/VL23.ini index 063323e1..2d6dd4c8 100644 --- a/IOB-WIN/DATA/CONF/VL23.ini +++ b/IOB-WIN/DATA/CONF/VL23.ini @@ -1,4 +1,4 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] ;Macchina preriscaldo barre per Valvital CNCTYPE=SIEMENS_PRESSOIL_CEI @@ -51,9 +51,7 @@ BLINK_FILT=0 ;BLINK_FILT=28 [OPTPAR] -;NO_PING=true ;PZCOUNT_MODE=STD.[PAR/MEM].info|BIT.indice -; attenzione memoria sempre base BYTE (1604 DW --> 6416...) PZCOUNT_MODE=STD.DB64.DBDW2 DISABLE_PZCOUNT=FALSE ENABLE_SEND_PZC_BLOCK=TRUE diff --git a/IOB-WIN/DATA/CONF/VL24.ini b/IOB-WIN/DATA/CONF/VL24.ini index 7db7e67d..337c7c4c 100644 --- a/IOB-WIN/DATA/CONF/VL24.ini +++ b/IOB-WIN/DATA/CONF/VL24.ini @@ -1,4 +1,4 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] ;Macchina preriscaldo barre per Valvital CNCTYPE=SIEMENS_SAET @@ -62,6 +62,7 @@ MAX_SEND_PZC_BLOCK=100 ENABLE_DYN_DATA=TRUE FORCE_DYN_DATA=TRUE +NEW_DYN_DATA=TRUE ; conf parametri memoria READ/WRITE PARAM_CONF=VL24.json diff --git a/IOB-WIN/DATA/CONF/VL24.json b/IOB-WIN/DATA/CONF/VL24.json index d66edb6d..ce58f22e 100644 --- a/IOB-WIN/DATA/CONF/VL24.json +++ b/IOB-WIN/DATA/CONF/VL24.json @@ -20,7 +20,7 @@ "name": "setPzComm", "description": "Qty", "memAddr": "DB1275.DBB144", - "tipoMem": "Int", + "tipoMem": "DInt", "index": 52, "size": 4 } diff --git a/IOB-WIN/DATA/CONF/VL25.ini b/IOB-WIN/DATA/CONF/VL25.ini index 4b13983e..741964a6 100644 --- a/IOB-WIN/DATA/CONF/VL25.ini +++ b/IOB-WIN/DATA/CONF/VL25.ini @@ -1,4 +1,4 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] ;Macchina preriscaldo barre per Valvital CNCTYPE=SIEMENS_INGENIA @@ -28,7 +28,7 @@ CMDREBO=/sendReboot.aspx?idxMacchina= ADDR_READ=DB700.DBB0 ADDR_WRITE=DB01.DBB0 SIZE_READ=44 -SIZE_WRITE=68 +SIZE_WRITE=48 [BLINK] diff --git a/IOB-WIN/DATA/CONF/VL25.json b/IOB-WIN/DATA/CONF/VL25.json index 27601b0b..12177afa 100644 --- a/IOB-WIN/DATA/CONF/VL25.json +++ b/IOB-WIN/DATA/CONF/VL25.json @@ -70,9 +70,9 @@ "period": 60, "factor": 1 }, - "ContaScartiCollaudo": { - "name": "ContaScartiCollaudo", - "description": "Contapezzi SCARTO per Collaudo", + "ContaScartiPressoil": { + "name": "ContaScartiPressoil", + "description": "Contapezzi SCARTO PRESSOIL", "memAddr": "DB700.DBB40", "tipoMem": "DInt", "index": 40, diff --git a/IOB-WIN/DATA/CONF/VL26.ini b/IOB-WIN/DATA/CONF/VL26.ini index e1044ea0..cb88fd54 100644 --- a/IOB-WIN/DATA/CONF/VL26.ini +++ b/IOB-WIN/DATA/CONF/VL26.ini @@ -1,4 +1,4 @@ -;Configurazione IOB-WIN +;Configurazione IOB-WIN [IOB] ;Macchina taglio barre per Valvital CNCTYPE=SIEMENS_SIMEC @@ -10,9 +10,9 @@ MODEL=180 [CNC] IP=192.168.219.15 -CPUTYPE=S71500 +CPUTYPE=S7300 RACK=0 -SLOT=1 +SLOT=0 [SERVER] MPIP=http://192.168.214.4 @@ -52,10 +52,11 @@ DISABLE_PZCOUNT=FALSE ENABLE_SEND_PZC_BLOCK=TRUE MIN_SEND_PZC_BLOCK=0 MAX_SEND_PZC_BLOCK=100 -;GESTIONE DATI DYN +; GEST DATI DYN ENABLE_DYN_DATA=TRUE FORCE_DYN_DATA=TRUE + ; conf parametri memoria READ/WRITE PARAM_CONF=VL26.json