Compare commits
1 Commits
| Author | SHA1 | Date | |
|---|---|---|---|
| 87ebd3a20d |
+6
-4
@@ -32,8 +32,8 @@
|
|||||||
require( 'EmtGenerator')
|
require( 'EmtGenerator')
|
||||||
EgtEnableDebug( false)
|
EgtEnableDebug( false)
|
||||||
|
|
||||||
PP_VER = '3.1f1'
|
PP_VER = '3.1f2'
|
||||||
PP_NVER = '3.1.6.1'
|
PP_NVER = '3.1.6.2'
|
||||||
MIN_MACH_VER = '2.5k1'
|
MIN_MACH_VER = '2.5k1'
|
||||||
MACH_NAME = EgtGetCurrMachineName()
|
MACH_NAME = EgtGetCurrMachineName()
|
||||||
|
|
||||||
@@ -163,7 +163,8 @@ if EgtExistsFile( sData) then
|
|||||||
end
|
end
|
||||||
if Machine.Offsets.X1_POS then MinX1 = -Machine.Offsets.X1_POS end
|
if Machine.Offsets.X1_POS then MinX1 = -Machine.Offsets.X1_POS end
|
||||||
if Machine.Offsets.X1_NEG then MaxX1 = -Machine.Offsets.X1_NEG end
|
if Machine.Offsets.X1_NEG then MaxX1 = -Machine.Offsets.X1_NEG end
|
||||||
if Machine.Offsets.PARK_X1 then ParkX1 = -Machine.Offsets.PARK_X1 end
|
if Machine.Offsets.PARK_X1POS then ParkFrnX1 = -Machine.Offsets.PARK_X1POS end
|
||||||
|
if Machine.Offsets.PARK_X1NEG then ParkX1 = -Machine.Offsets.PARK_X1NEG end
|
||||||
if Machine.Offsets.Z1_NEG then MinZ1 = Machine.Offsets.Z1_NEG end
|
if Machine.Offsets.Z1_NEG then MinZ1 = Machine.Offsets.Z1_NEG end
|
||||||
if Machine.Offsets.Z1_POS then MaxZ1 = min( MaxZ1, Machine.Offsets.Z1_POS) end
|
if Machine.Offsets.Z1_POS then MaxZ1 = min( MaxZ1, Machine.Offsets.Z1_POS) end
|
||||||
if Machine.Offsets.PARK_Z1 then ParkZ1 = Machine.Offsets.PARK_Z1 end
|
if Machine.Offsets.PARK_Z1 then ParkZ1 = Machine.Offsets.PARK_Z1 end
|
||||||
@@ -220,13 +221,14 @@ if EgtExistsFile( sData) then
|
|||||||
-- aggiustamenti
|
-- aggiustamenti
|
||||||
MinY1 = MinV1 + MinDeltaYV
|
MinY1 = MinV1 + MinDeltaYV
|
||||||
MaxY1 = MaxMchY1
|
MaxY1 = MaxMchY1
|
||||||
ParkV1 = MaxV1
|
ParkV1 = MaxV1
|
||||||
ParkY1 = ParkV1 + MinDeltaYV
|
ParkY1 = ParkV1 + MinDeltaYV
|
||||||
MinY2 = MinMchY2
|
MinY2 = MinMchY2
|
||||||
MaxY2 = MaxV2 - MinDeltaYV
|
MaxY2 = MaxV2 - MinDeltaYV
|
||||||
ParkV2 = MinV2
|
ParkV2 = MinV2
|
||||||
ParkY2 = ParkV2 - MinDeltaYV
|
ParkY2 = ParkV2 - MinDeltaYV
|
||||||
ParkX1 = min( ParkX1, MaxX1)
|
ParkX1 = min( ParkX1, MaxX1)
|
||||||
|
ParkFrnX1 = max( ParkFrnX1, MinX1)
|
||||||
ParkCSawZ1 = min( ParkCSawZ1, MaxZ1)
|
ParkCSawZ1 = min( ParkCSawZ1, MaxZ1)
|
||||||
ParkCSaw0Z1 = min( ParkCSaw0Z1, MaxZ1)
|
ParkCSaw0Z1 = min( ParkCSaw0Z1, MaxZ1)
|
||||||
Mortiser = ( Mortiser and not Progress)
|
Mortiser = ( Mortiser and not Progress)
|
||||||
|
|||||||
Reference in New Issue