From 0fff7dff2b949bca9558c62e7bd96468a0dd7ece Mon Sep 17 00:00:00 2001 From: Dario Sassi Date: Thu, 25 Feb 2021 17:45:12 +0000 Subject: [PATCH] DataBeam : - corretto riconoscimento warnings per tipo scarico (100,101 e 102). --- Process.lua | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Process.lua b/Process.lua index b588058..d9b7f05 100644 --- a/Process.lua +++ b/Process.lua @@ -241,7 +241,7 @@ local function MyProcessFeatures() sOutput = sOutput .. string.format( '[%d,%d] %s\n', Stats[i].CutId, Stats[i].TaskId, Stats[i].Msg) elseif Stats[i].Err < 0 then -- se segnalazione scarico pezzo standard, incompleto o a caduta - if Stats[i].Err == -101 or Stats[i].Err == -102 or Stats[i].Err == -103 then + if Stats[i].Err == -100 or Stats[i].Err == -101 or Stats[i].Err == -102 then -- non faccio niente else nWarnCnt = nWarnCnt + 1