diff --git a/MTC_Adapter/MTC_Adapter/AdapterFanuc.cs b/MTC_Adapter/MTC_Adapter/AdapterFanuc.cs
index 0bded35..55825b7 100644
--- a/MTC_Adapter/MTC_Adapter/AdapterFanuc.cs
+++ b/MTC_Adapter/MTC_Adapter/AdapterFanuc.cs
@@ -80,13 +80,15 @@ namespace MTC_Adapter
///
///
public AdapterFanuc(MainForm caller, AdapterConf adpConf) : base(caller, adpConf)
- {
+ {
+ // รจ littel endian (NON serve conversione)
+ hasBigEndian = false;
+
lg.Info("Start init Adapter FANUC all'IP {0}", utils.CRS("ipPLC"));
parentForm.commPlcActive = true;
Runtime.CreateNC(CNC.NcType.FANUC, utils.CRS("ipPLC"));
parentForm.commPlcActive = false;
-
// inizializzo posizioni assi...
prevPosAxis = new double[adpConf.nAxis];
prevDirAxis = new int[adpConf.nAxis];
diff --git a/MTC_Adapter/MTC_Adapter/DATA/CONF/Adapter_ItemList.xml b/MTC_Adapter/MTC_Adapter/DATA/CONF/Adapter_ItemList.xml
index 66f2df4..9bf8da6 100644
--- a/MTC_Adapter/MTC_Adapter/DATA/CONF/Adapter_ItemList.xml
+++ b/MTC_Adapter/MTC_Adapter/DATA/CONF/Adapter_ItemList.xml
@@ -1,8 +1,8 @@
1
- ADAPTER_SIEMENS
- SIEMENS
+ ADAPTER_FANUC
+ FANUC
0
0
0
@@ -83,10 +83,6 @@
Path_01
-
- Path_02
-
-
@@ -173,135 +169,5 @@
-
- Axis_07
-
-
- Axis_07_Type
- LINEAR
-
-
- Axis_07_Grp
- 00
-
-
-
-
- Axis_08
-
-
- Axis_08_Type
- LINEAR
-
-
- Axis_08_Grp
- 00
-
-
-
-
- Axis_09
-
-
- Axis_09_Type
- LINEAR
-
-
- Axis_09_Grp
- 00
-
-
-
-
- Axis_10
-
-
- Axis_10_Type
- LINEAR
-
-
- Axis_10_Grp
- 00
-
-
-
-
- Axis_11
-
-
- Axis_11_Type
- LINEAR
-
-
- Axis_11_Grp
- 00
-
-
-
-
- Axis_12
-
-
- Axis_12_Type
- LINEAR
-
-
- Axis_12_Grp
- 00
-
-
-
-
- Axis_13
-
-
- Axis_13_Type
- ROTARY
-
-
- Axis_13_Grp
- 00
-
-
-
-
- Axis_14
-
-
- Axis_14_Type
- ROTARY
-
-
- Axis_14_Grp
- 00
-
-
-
-
- Axis_15
-
-
- Axis_15_Type
- LINEAR
-
-
- Axis_15_Grp
- 00
-
-
-
-
- Axis_16
-
-
- Axis_16_Type
- LINEAR
-
-
- Axis_16_Grp
- 00
-
-
-
\ No newline at end of file
diff --git a/MTC_Adapter/MTC_Adapter/DATA/CONF/AlarmList.map b/MTC_Adapter/MTC_Adapter/DATA/CONF/AlarmList.map
index 6698345..c799ba6 100644
--- a/MTC_Adapter/MTC_Adapter/DATA/CONF/AlarmList.map
+++ b/MTC_Adapter/MTC_Adapter/DATA/CONF/AlarmList.map
@@ -377,7 +377,7 @@
000376|PLC|FAULT|[COD 002107] - 530 PULSANTIERA ESTERNA ABILITATA
000377|PLC|FAULT|[COD 002108] - 504 CAMBIO UTENSILE INTERROTTO
000378|PLC|FAULT|[COD 002109] - 363 MONTANTE CENTRALE ALTO
-000379|PLC|FAULT|[COD 002110] - =--- PREALLARME TERMICO TORQUE A
+000379|PLC|FAULT|[COD 002110] - --- PREALLARME TERMICO TORQUE A
000380|PLC|FAULT|[COD 002111] - 498 CARICO MASSIMO SUL MANDRINO SUPERATO SOGLIA S1
000381|PLC|FAULT|[COD 002112] - --- PREALLARME TERMICO TORQUE C
000382|PLC|FAULT|[COD 002113] - 432 UTENSILE NON SGANCIATO
@@ -431,7 +431,7 @@
000430|PLC|FAULT|[COD 002161] - 289 ATTREZZAGGIO CAMBIO UTENSILE 2 IN CORSO
000431|PLC|FAULT|[COD 002162] - 584 PORTA DI SICUREZZA MAGAZZINO DISCO 2 NON CHIUSA
000432|PLC|FAULT|[COD 002163] - 514 PROTEZIONE MAGAZZINO DISCO 2 NON IN POSIZIONE
-000433|PLC|FAULT|[COD 002164] -
+000433|PLC|FAULT|[COD 002164] - ...
000434|PLC|FAULT|[COD 002165] - 550 GRUPPO DI FORATURA NON IN POSIZIONE
000435|PLC|FAULT|[COD 002166] - ...
000436|PLC|FAULT|[COD 002167] - ...