diff --git a/MTC_Adapter/SCMA/setupTgt.bat b/MTC_Adapter/SCMA/setupTgt.bat index 2f9cd22..cb27122 100644 --- a/MTC_Adapter/SCMA/setupTgt.bat +++ b/MTC_Adapter/SCMA/setupTgt.bat @@ -5,6 +5,7 @@ REM INIZIO eliminando i files che COMUNQUE devo copiare x target... if %1 == "Release" goto Release if %1 == "Debug" goto Debug +if %1 == "CMS-ESA" goto CMS if %1 == "CMS-FANUC" goto CMS if %1 == "CMS-OSAI" goto CMS if %1 == "CMS-SIEMENS" goto CMS @@ -15,9 +16,9 @@ echo Release: nulla da copiare goto END :Debug -echo Debug: copia file ini x simulazione ESA +echo Debug: copia file ini x simulazione ESA x CMS... del %2"DATA\CONF\EsaKvara.ini" -copy %2"Resources\SCM\EsaKvara_SIM.ini" %2"DATA\CONF\EsaKvara.ini" +copy %2"Resources\CMS\EsaKvara_SIM.ini" %2"DATA\CONF\EsaKvara.ini" goto END :CMS @@ -33,9 +34,10 @@ REM del /F /Q %2"DATA\CONF\*.*" copy %2"Resources\CMS\CMS.ico" %2"Resources\Scma.ico" copy %2"Resources\CMS\AlarmListEmpty.map" %2"DATA\CONF\AlarmListCNC.map" REM ora verifico tipo controllo esatto... +if %1 == "CMS-ESA" goto ESACMS if %1 == "CMS-FANUC" goto FANUC -if %1 == "CMS-SIEMENS" goto SIEMENS if %1 == "CMS-OSAI" goto OSAI +if %1 == "CMS-SIEMENS" goto SIEMENS :SCM echo SCM: copio files SCM - Rimini @@ -59,7 +61,39 @@ copy %2"Resources\SCM\IOT_DWordList.map" %2"DATA\CONF\IOT_DWordList.map" copy %2"Resources\SCM\IOT_StringList.map" %2"DATA\CONF\IOT_StringList.map" goto END +:ESACMS +REM TUTTO da verificare +echo CMS: copio files ESA +del %2"Resources\Scma.ico" +del %2"DATA\CONF\Adapter_ItemList.xml" +del %2"DATA\CONF\AlarmList.map" +REM del %2"DATA\CONF\EsaKvara.ini" +del %2"DATA\CONF\IOT_ByteList.map" +del %2"DATA\CONF\IOT_WordList.map" +del %2"DATA\CONF\IOT_DWordList.map" +del %2"DATA\CONF\IOT_StringList.map" +REM del /F /Q %2"DATA\CONF\*.*" +copy %2"Resources\SCM\SCM.ico" %2"Resources\Scma.ico" +copy %2"Resources\SCM\SCM_ESA.xml" %2"DATA\CONF\Adapter_ItemList.xml" +copy %2"Resources\SCM\AlarmListEsaGv.map" %2"DATA\CONF\AlarmList.map" +copy %2"Resources\SCM\AlarmListEsaGvCNC.map" %2"DATA\CONF\AlarmListCNC.map" +copy %2"Resources\SCM\EsaKvara_PROD.ini" %2"DATA\CONF\EsaKvara.ini" +copy %2"Resources\SCM\IOT_ByteList.map" %2"DATA\CONF\IOT_ByteList.map" +copy %2"Resources\SCM\IOT_WordList.map" %2"DATA\CONF\IOT_WordList.map" +copy %2"Resources\SCM\IOT_DWordList.map" %2"DATA\CONF\IOT_DWordList.map" +copy %2"Resources\SCM\IOT_StringList.map" %2"DATA\CONF\IOT_StringList.map" + + +copy %2"Resources\CMS\FANUC.xml" %2"DATA\CONF\Adapter_ItemList.xml" +copy %2"Resources\CMS\AlarmListFANUC.map" %2"DATA\CONF\AlarmList.map" +copy %2"Resources\CMS\AnalogDataFANUC.map" %2"DATA\CONF\AnalogData.map" +copy %2"Resources\CMS\CounterListFANUC.map" %2"DATA\CONF\CounterList.map" +copy %2"Resources\CMS\StatusListFANUC.map" %2"DATA\CONF\StatusList.map" + +goto END + :FANUC +echo CMS: copio files FANUC copy %2"Resources\CMS\FANUC.xml" %2"DATA\CONF\Adapter_ItemList.xml" copy %2"Resources\CMS\AlarmListFANUC.map" %2"DATA\CONF\AlarmList.map" copy %2"Resources\CMS\AnalogDataFANUC.map" %2"DATA\CONF\AnalogData.map" @@ -68,6 +102,7 @@ copy %2"Resources\CMS\StatusListFANUC.map" %2"DATA\CONF\StatusList.map" goto END :SIEMENS +echo CMS: copio files SIEMENS copy %2"Resources\CMS\SIEMENS.xml" %2"DATA\CONF\Adapter_ItemList.xml" copy %2"Resources\CMS\AlarmListSIEMENS.map" %2"DATA\CONF\AlarmList.map" copy %2"Resources\CMS\AnalogDataSIEMENS.map" %2"DATA\CONF\AnalogData.map" @@ -76,6 +111,7 @@ copy %2"Resources\CMS\StatusListSIEMENS.map" %2"DATA\CONF\StatusList.map" goto END :OSAI +echo CMS: copio files OSAI copy %2"Resources\CMS\OSAI.xml" %2"DATA\CONF\Adapter_ItemList.xml" copy %2"Resources\CMS\AlarmListOSAI.map" %2"DATA\CONF\AlarmList.map" copy %2"Resources\CMS\AnalogDataOSAI.map" %2"DATA\CONF\AnalogData.map"